Apparatus Characterizes Transient Voltages in Real Time

The figure shows a prototype of a relatively inexpensive electronic monitoring apparatus that measures and records selected parameters of lightning-induced transient voltages on communication and power cables. The selected parameters, listed below, are those most relevant to the ability of lightning-induced transients to damage electronic equipment. This apparatus bridges a gap between some traditional transient-voltage recorders that record complete waveforms and other traditional transient-voltage recorders that record only peak values: By recording the most relevant parameters and only those parameters this apparatus yields more useful information than does a traditional peak-value (only) recorder while imposing much smaller data-storage and data-transmission burdens than does a traditional complete-waveform recorder. Also, relative to a complete-waveform recorder, this apparatus is more reliable and can be built at lower cost because it contains fewer electronic components. The transients generated by sources other than lightning tend to have frequency components well below 1 MHz. Most commercial transient recorders can detect and record such transients, but cannot respond rapidly enough for recording lightning-induced transient voltage peaks, which can rise from 10 to 90 percent of maximum amplitude in a fraction of a microsecond. Moreover, commercial transient recorders cannot rearm themselves rapidly enough to respond to the multiple transients that occur within milliseconds of each other on some lightning strikes. One transient recorder, designed for Kennedy Space Center earlier [ Fast Transient-Voltage Recorder (KSC- 11991), NASA Tech Briefs, Vol. 23, No. 10, page 6a (October 1999)], is capable of sampling transient voltages at peak values up to 50 V in four channels at a rate of 20 MHz. That recorder contains a trigger circuit that continuously compares the amplitudes of the signals on four channels to a preset triggering threshold. When a trigger signal is received, a volatile memory is filled with data for a total time of 200 ms. After the data are transferred to nonvolatile memory, the recorder rearms itself within 400 ms to enable recording of subsequent transients. Unfortunately, the recorded data must be retrieved through a serial communication link. Depending on the amount of data recorded, the memory can be filled before retrieval is completed. Although large amounts of data are recorded and retrieved, only a small part of the information (the selected parameters) is usually required. The present transient-voltage recorder provides the required information, without incurring the overhead associated with the recording, storage, and retrieval of complete transient-waveform data. In operation, this apparatus processes transient voltage waveforms in real time to extract and record the selected parameters. An analog-to-digital converter that operates at a speed of as much as 100 mega-samples per second is used to sample a transient waveform. A real-time comparator and peak detector are implemented by use of fast field-programmable gate arrays.

Medelius, Pedro↗

Magnetic-Flux-Compensated Voltage Divider

A magnetic-flux-compensated voltage-divider circuit has been proposed for use in measuring the true potential across a component that is exposed to large, rapidly varying electric currents like those produced by lightning strikes. An example of such a component is a lightning arrester, which is typically exposed to currents of the order of tens of kiloamperes, having rise times of the order of hundreds of nanoseconds. Traditional voltage-divider circuits are not designed for magnetic-flux-compensation: They contain uncompensated loops having areas large enough that the transient magnetic fluxes associated with large transient currents induce spurious voltages large enough to distort voltage-divider outputs significantly. A drawing of the proposed circuit was not available at the time of receipt of information for this article. What is known from a summary textual description is that the proposed circuit would contain a total of four voltage dividers: There would be two mixed dividers in parallel with each other and with the component of interest (e.g., a lightning arrester), plus two mixed dividers in parallel with each other and in series with the component of interest in the same plane. The electrical and geometric configuration would provide compensation for induced voltages, including those attributable to asymmetry in the volumetric density of the lightning or other transient current, canceling out the spurious voltages and measuring the true voltage across the component.

Mata, Carlos T.↗

High voltage studies of inverted-geometry ceramic insulators for a 350 kV DC polarized electron gun

Jefferson Lab is constructing a 350 kV direct current high voltage photoemission gun employing a compact inverted-geometry insulator. This photogun will produce polarized electron beams at an injector test facility intended for low energy nuclear physics experiments, and to assist the development of new technology for the Continuous Electron Beam Accelerator Facility. A photogun operating at 350kV bias voltage reduces the complexity of the injector design, by eliminating the need for a graded-beta radio frequency “capture” section employed to boost lower voltage beams to relativistic speed. However, reliable photogun operation at 350 kV necessitates solving serious high voltage problems related to breakdown and field emission. This study focuses on developing effective methods to avoid breakdown at the interface between the insulator and the commercial high voltage cable that connects the photogun to the high voltage power supply. Three types of inverted insulators were tested, in combination with two electrode configurations. Our results indicate that tailoring the conductivity of the insulator material, and/or adding a cathode triple-junction screening electrode, effectively serves to increase the hold-off voltage from 300kV to more than 375kV. In conclusion, electrostatic field maps suggest these configurations serve to produce a more uniform potential gradient across the insulator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Capacitor Voltage Ripple Estimation and Optimal Sizing of Modular Multi-Level Converters for Variable-Speed Drives

This article deals with the sizing of submodule capacitors for modular multilevel converters (MMCs) used for variable speed drives for medium voltage and high voltage electric machines. Variable speed drives are required to run over a wide frequency range from zero to a few hundred Hz or even over 1 kHz. Under low frequency operation (<30 Hz), a large current ripple flowing through the MMC submodule capacitors will cause significant capacitor voltage fluctuation. This article proposes an optimal submodule capacitor selection method based on the common-mode voltage injection. The proposed sizing model includes two functions: 1) accurately estimating the capacitor voltage ripple based on the drive system parameters; and 2) identifying the minimum capacitance of the submodule capacitors based on the allowed maximum capacitor voltage fluctuations. Simulation and experimental results show that the error between the actual and estimated values of the voltage fluctuation is within 3% using the proposed model.

42 ENGINEERING↗

PMU-Based Monitoring and Mitigation of Delayed Voltage Recovery Using Admittances

This project analyzes the delayed voltage recovery phenomenon by simplifying the Western Electricity Coordinating Council (WECC) composite load model using the load admittance and the thermal relay dynamics. From this analysis, a closed form expression approximating the recovery time is derived and the key load parameters impacting the behavior of voltage recovery are identified. A monitoring scheme based on the measured load admittance is then proposed to detect the onset of stalling, even in the presence of voltage oscillations, and estimate the duration of the delayed voltage recovery. A mitigation scheme utilizing smart thermostats and offline learning is also derived to ensure that the voltage recovers to the pre-contingency voltage within a specified time. Both the monitoring and mitigation schemes only need local measurements at a substation making them promising for online applications. Results for the monitoring and mitigation schemes are described in detail for the IEEE 162 bus system validating the various assumptions used for the analysis and establishing the connection between the delayed voltage recovery phenomenon and load admittance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analytic Neural Network Gaussian Process Enabled Chance-Constrained Voltage Regulation for Active Distribution Systems with PVs, Batteries and EVs

This paper proposes an analytic neural network Gaussian process (NNGP)-based chance-constrained real-time voltage regulation method for active distribution systems with photovoltaics (PVs), batteries, and electric vehicles (EVs). NNGP can utilize historical measurement data to achieve real-time probabilistic node voltage estimation through Bayesian inference. Then, NNGP is fully analytically embedded into the optimal power flow model to perform voltage regulation and adapt to various topological changes. The uncertainties of voltage estimations are easily considered via the chance constraint, and it has been shown that the adoption of this chance constraint can significantly improve the reliability of voltage regulation under various scenarios. The comparison results with other methods, carried out on a real 759-node distribution system located in western Colorado, U.S., show that the proposed method can achieve accurate voltage estimation across different topologies and reliably perform voltage regulation considering PVs, batteries, and EVs.

active distribution systems↗

PWM for Simultaneous Minimization of Switching Losses and CM Voltage in Current Source Inverters

This article proposes a new pulsewidth modulation (PWM) scheme that reduces common-mode (CM) voltage and switching losses simultaneously in CSI. The proposed PWM [i.e., reduced voltages PWM (RVM)] reduces CM voltages and switching losses by selecting the optimal zero current vector and PWM sequence based on the CSI output voltage conditions. This article also proves the proposed RVM achieves both objectives (i.e., reduced CM voltage and switching losses) simultaneously for all CSI operating conditions without compromising the other objective. The proposed RVM inherently achieves zero-voltage switching (ZVS) conditions during the zero current vector transitions, further reducing the switching losses. Experimental results demonstrate significant reductions in CM voltage, reaching up to approximately 95%, accompanied by an increase of up to about 5.5% in CSI efficiency across a wide operating range compared to alternative PWM methods, confirming the predicted advantages of the proposed RVM.

42 ENGINEERING↗

Coordinated Voltage Regulator Control in Systems with High-level Penetration of Distributed Energy Resources

Voltage Control is one of the fundamental operational requirements for power systems, which can become very challenging in presence of distributed energy resources (DERs). This paper presents a novel method for inclusion of voltage regulators (VRs) in a distributed voltage control framework for distribution networks. The goal is to coordinate and optimize the operation of voltage regulators. Of special interest are networks with high penetration of distributed energy resources, PVs in particular, which exhibit overvoltage problems. To that end, we have adopted a dynamic VR model from the literature and applied the proposed coordinated control method on a modified IEEE 123 test system with very high penetration of PVs. Over Voltage Severity Index (OVSI) and Cumulative Voltage Variation Index (CVVI) have been defined and used in the algorithm to control the regulation steps of VRs. The developed method is compared against the base case with no control and the results show its effectiveness in coordinated VR control.

Cumulative Voltage Variation Index (CVVI)↗

A look into the voltage plateau signal for detection and quantification of lithium plating in lithium-ion cells

Voltage plateau during relaxation or discharge after charging is a distinct signal associated with stripping of deposited Li metal and hence a feasible tool for online detection of Li plating in Li-ion batteries. In this report we present a physics-based model with incorporation of Li plating and stripping to gain a fundamental understanding of the voltage plateau behavior. Specifically, we focus on the internal cell characteristics when voltage plateau occurs and on key factors affecting the shape and duration of voltage plateau. Furthermore, the validity of using the duration of voltage plateau for estimating Li plating amount is assessed. It is found that the duration of voltage plateau depends on the rate of Li stripping, while the stripping rate is restricted by the capability of Li+ intercalation into graphite. Parameters like intercalation kinetics, solid-state diffusivity of graphite and cell temperature can substantially influence the voltage curves even with the same amount of Li plating. Further, we report an interesting phenomenon that during Li stripping one part of anode near the separator has net oxidation current (local stripping rate > intercalation rate), providing Li+ ions and electrons to the other part of anode near the foil which has net reduction current.

25 ENERGY STORAGE↗

Organic thin-film transistors with a bottom bilayer gate dielectric having a low operating voltage and high operational stability

This study reports on p-channel bottom-gate organic thin-film transistors (OTFT) that achieve low-voltage operation with a thin bilayer gate dielectric of CYTOP/HfO 2 that also leads to high operational stability. A bottom-gate geometry allows the thickness of the gate dielectric to be reduced to 17 nm, thereby increasing the gate dielectric capacitance density to a value of up to 258 nF/cm 2 . All OTFTs yielded threshold voltages (V TH ) lower than -1 V, thereby providing minimum operating voltage (gate to source voltage ~ V TH ) of -1 V with field-effect mobility values in the range from 0.3 to 0.8 cm 2 /Vs and subthreshold swing values below 100 mV/dec. Operational stability during DC bias stress was found similar to that measured in devices with a top-gate geometry, with about 1% of drain current change after 6 h. Here, using a double-stretched exponential function, the operational stability characteristics were modeled. It was found that by increasing the metal oxide layer thickness, the threshold voltage can shift toward positive values under DC stress tests. For CYTOP layer thicknesses above 15 nm, a thicker CYTOP layer was found to shift the threshold voltage in the opposite direction toward negative values. Furthermore, these p-channel bottom-gate organic transistor with a bilayer gate dielectric of CYTOP/HfO 2 combine high mobility, high operational stability, and lower voltage operation of -1 V compared to top-gate OTFTs.

36 MATERIALS SCIENCE↗

Accurate Prediction of Voltage of Battery Electrode Materials Using Attention-Based Graph Neural Networks

Performing first-principles calculations to discover electrodes’ properties in the large chemical space is a challenging task. While machine learning (ML) has been applied to effectively accelerate those discoveries, most of the applied methods ignore the materials’ spatial information and only use predefined features: based only on chemical compositions. Here, we propose two attention-based graph convolutional neural network techniques to learn the average voltage of electrodes. Our proposed methods, which combine both atomic composition and atomic coordinates in 3D-space, improve the accuracy in voltage prediction significantly when compared to composition-based ML models. The first model directly learns the chemical reaction of electrodes and metal ions to predict their average voltage, whereas the second model combines electrodes’ ML predicted formation energy (E form ) to compute their average voltage. Our E form -based model demonstrates improved accuracy in transferability from our subset of learned Li ions to Na ions. Moreover, we predicted the theoretical voltage of 10 Na x MPO 4 F (M = Ti, Cr, Fe, Cu, Mn, Co, and Ni) fluorophosphate battery frameworks, which are unavailable in the Material Project database. It could be shown that we can expect average voltages higher than 3.1 V from those Na battery frameworks except from the NaTiPO 4 F and TiPO 4 F pair of electrodes, which offer an average voltage of 1.32 V.

25 ENERGY STORAGE↗

Hierarchical Control Scheme for Improving Transient Voltage Recovery of a DFIG-Based WPP

Modern grid codes require that wind power plants (WPPs) inject reactive power according to the voltage dip at a point of interconnection (POI). This requirement helps to support a POI voltage during a fault. However, if a fault is cleared, the POI and wind turbine generator (WTG) voltages are likely to exceed acceptable levels unless the WPP reduces the injected reactive power quickly. This might deteriorate the stability of a grid by allowing the disconnection of WTGs to avoid any damage. This paper proposes a hierarchical control scheme of a doubly-fed induction generator (DFIG)-based WPP. The proposed scheme aims to improve the reactive power injecting capability during the fault and suppress the overvoltage after the fault clearance. To achieve the former, an adaptive reactive power-to-voltage scheme is implemented in each DFIG controller so that a DFIG with a larger reactive power capability will inject more reactive power. To achieve the latter, a washout filter is used to capture a high frequency component contained in the WPP voltage, which is used to remove the accumulated values in the proportional-integral controllers. Test results indicate that the scheme successfully supports the grid voltage during the fault, and recovers WPP voltages without exceeding the limit after the fault clearance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Statistical and clustering analysis for disturbances: A case study of voltage dips in wind farms

This study proposes and evaluates an alternative statistical methodology to analyze a large number of voltage dips. For a given voltage dip, a set of lengths is first identified to characterize the root mean square (rms) voltage evolution along the disturbance, deduced from partial linearized time intervals and trajectories. Principal component analysis and K-means clustering processes are then applied to identify rms-voltage patterns and propose a reduced number of representative rms-voltage profiles from the linearized trajectories. This reduced group of averaged rms-voltage profiles enables the representation of a large amount of disturbances, which offers a visual and graphical representation of their evolution along the events, aspects that were not previously considered in other contributions. The complete process is evaluated on real voltage dips collected in intense field-measurement campaigns carried out in a wind farm in Spain among different years. The results are included in this paper.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Dominant Influencer of Voltage Fluctuation (DIVF) for Power Distribution System

Variability in power generation at multiple consumer owned renewable energy sources can cause random voltage fluctuations, which may result in voltage violations at multiple nodes in a power distribution system. Traditional methods of voltage control are ineffective to address fast voltage variations. New dynamic methods of voltage control using end user devices can significantly benefit from the knowledge of the dominant influencer of voltage fluctuation (DIVF). This paper introduces information theoretic metrics to identify DIVF for every node in the power distribution system. A node can be DIVF due to its location in the distribution system and its capacity to generate and change its power. Use of traditional power flow algorithms to identify the DIVF is computationally complex which limits their use in real-time applications. In this work, information theoretic indicators of the DIVF are computed analytically in a computationally efficient manner, and their effectiveness to identify the DIVF is tested using the IEEE 69 node test system. From simulations, it is illustrated that differential entropy, Kullback-Leibler distance and Frechet distance are effective indicators of the DIVF and can successfully identify the most influential nodes providing the foundation for intelligent voltage control.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Deep Reinforcement Learning Enabled Physical-Model-Free Two-Timescale Voltage Control Method for Active Distribution Systems

Active distribution networks are being challenged by frequent and rapid voltage violations due to renewable energy integration. Conventional model-based voltage control methods rely on accurate parameters of the distribution networks, which are difficult to achieve in practice. This paper proposes a novel physical-model-free two-timescale voltage control framework for active distribution systems. To achieve fast control of PV inverters, the whole network is first partitioned into several subnetworks using voltage-reactive power sensitivity. Then, the scheduling of PV inverters in the multiple sub-networks is formulated as Markov games and solved by a multi-agent soft actor-critic (MASAC) algorithm, where each subnetwork is modeled as an intelligent agent. All agents are trained in a centralized manner to learn a coordinated strategy while being executed based on only local information for fast response. For the slower time-scale control, OLTCs and switched capacitors are coordinated by a single agent-based SAC algorithm using the global information with considering control behaviors of the inverters. Particularly, the two-level agents are trained concurrently with information exchange according to the reward signal calculated from the data-driven surrogate model. Comparative tests with different benchmark methods on IEEE 33-and 123-bus systems and 342-node low voltage distribution system demonstrate that the proposed method can effectively mitigate the fast voltage violations and achieve systematical coordination of different voltage regulation assets without the knowledge of accurate system model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Voltage Stability Constrained Moving Target Defense Against Net Load Redistribution Attacks

Moving target defense (MTD) using distributed flexible AC transmission system (D-FACTS) devices is a promising defense strategy to detect stealthy false data injection (FDI) attacks against the power system state estimation. However, all existing studies myopically perturb the reactance of D-FACTS lines without considering the system voltage stability. In this paper, we first illustrate voltage instability induced by MTDs in a three-bus system. To address this issue, we further propose a novel MTD framework that explicitly considers system voltage stability by using continuation power flow and voltage stability indices. We mathematically derive the sensitivity matrix of voltage stability index to line impedance, on which an optimization problem for maximizing voltage stability index is formulated. This framework is tested on the IEEE 14-bus and the IEEE 118-bus transmission systems, in which net load redistribution attacks are launched by sophisticated attackers. Here, the simulation results show the effectiveness of the proposed framework in circumventing the voltage instability while maintaining the detection effectiveness of MTD. We conduct case studies with and without the proposed framework under different MTD planning and operational methods. The impacts of the proposed two methods on attack detection effectiveness and system economic metrics are also revealed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Experimental demonstration of voltage-matched two-terminal tandem minimodules

Mechanically stacked tandem solar cells are a potential near-term solution for increasing the efficiency of photovoltaic modules. Practical implementation requires an interconnection approach that maximizes efficiency and minimizes complexity and cost. Connecting the top and bottom cells in a voltage-matched configuration allows two-terminal modules to be fabricated without altering the cell design or processing methods. Here, we experimentally demonstrate two-terminal voltage-matched GaInP 2 / Si minimodules. The two-terminal minimodules performed just as well as four terminal configurations when voltage-matching requirements were met. The magnitude of the efficiency loss experienced by the voltage-matched minimodule when voltage-matched conditions were not met depends on whether the voltage was constrained by the GaInP 2 or Si cells. Monte Carlo simulations also indicate that the two-terminal voltage-matched tandems respond to small cell-to-cell parameter variations in a similar manner as four terminal tandems.

14 SOLAR ENERGY↗

Quantifying Properties for a Mechanistic, Predictive Understanding of Aqueous Impact on Aging of Medium and Low Voltage AC and DC Cabling in Nuclear Power Plants

To address the gap in knowledge in understanding degradation in relevant service conditions, this project aimed to develop a mechanistic, predictive model of medium and low voltage cable failure based on the primary environmental degradation parameters of aqueous immersion time, temperature, and the oxidation extent. To do so, we took a two-fold approach toward evaluating degradation as related to the aqueous condition. First, we evaluated the chemical, mechanical, and electrical properties of polymers that comprise the cabling insulation under varied aqueous conditions at different temperatures. Secondly, we evaluated the performance of insulation materials under similar accelerated aging conditions in addition to the dielectric breakdown of the cabling under submersion conditions. Thermal oxidation and immersion of LDPE thin films were done using a Parr vessel and the extent of oxidation was monitored using the carbonyl index from ATR-FTIR spectrum, a ratio quantifying the carbonyl functionality produced on the LDPE film surface. Increasing the temperature, oxidation time, and oxygen pressure increased the water-vapor permeability and the carbonyl content. Thermogravimetric analysis of the films confirmed that there is indeed an initial weight loss of the smaller molecular weight molecules and volatiles. At higher temperatures, there is a secondary mass loss. Up to 70°C, the mass loss curves were similar until 80°C, when the aged films decreased at a much greater rate with respect to increasing temperature. This was seen in the 10, 50, 90% weight loss temperatures. The mechanical properties of sheet PP and HDPE as well as injection molded LDPE, HDPE, HDPP dog bones were plotted with respect to the time spent in the Parr vessel during thermal oxidation. For the sheet PP and HDPE, the UTS and the modulus of elasticity decreased while the elongation increased. The injection-molded LDPE, HDPE, and HDPP dog bones experienced a similar trend where the changes in the properties were within experimental uncertainty. This analysis of LDPE in dry and immersive oxygen-rich environments is an important baseline for future experiments looking at other degradation mechanisms. A predictive aging model for low-density polyethylene insulative cable housings was developed. This model revealed a combination of physical and chemical processes which lead to an increase in permeability and a decrease in strength of the insulator. In creating this predictive model, a gap of knowledge in the literature was revealed in two areas: understanding how the crystallinity of a polymer changes with time and visualizing the predicted pores formed through the insulator which leads to failure. Developing and using an adapted ATR-FTIR method, crystallinity was monitored and compared to bulk crystallinity found via DSC. Inhomogeneity in crystallinity changes were observed but the FTIR method but was found to be less reliable. Pore visualization was found utilizing electrical impedance spectroscopy saturated aged polyethylene films with synthesized citrate-capped gold nanoparticles, and chloroauric acid precursor. results indicate a decreasing impedance of the polyethylene films caused by the transport of ions through the film. SEM imaging was then performed for elemental analysis of the films and counter electrodes for the presence of ions. Chloride and gold ions were detected; however, no nanoparticles were found. This gives an estimated pore size of at least 0.3 nm through the aged film. Cyclic submergence of polyethylene and polypropylene in aqueous solutions of copper sulfate and Harrison’s solution were examined. It was discovered that aging in these mixed conditions and at 90°C did cause a small, yet significant increase to tensile strength for both unaged polyethylene and polypropylene. The PE and PP in cycled and submerged conditions did not have tensile strengths significantly different from dry-aged after 16 weeks. For both solutions, it was determined that capacitance increases with both water tree depth and cable temperature and is relatively independent of changing water tree AR. As for resistance, there is no apparent change between depth percentages of 10 and 80 for both solutions. This is because the water tree has not yet entered the conductor and thus there is no shorting current flowing through the tree yet. Between 80 and 100% water tree depth, it is observed that for both solutions there is a rapid decrease in resistance because the tree is now impacting the conductor shield and allowing shorting current to flow through it. The relationship between resistance and temperature was found to be inversed. As temperature increases, resistance decreases for both water tree solutions with distilled water having the most apparent difference across the range of temperatures simulated. With regards to water tree AR, resistance was found to be relatively independent at depth percentages of 10, 50, and 70, but there was some relationship at 100% depth for both solutions. At this depth, as water tree AR increased, resistance was found to also increase. Through the examination of voltage and electric field distribution plots, it was confirmed for EPR cables that increasing water tree depth leads to increasing distortion. The increase in shorting current at 100% depth for aqueous copper sulfate compared to distilled water was also visualized. Lastly, the relationship between shorting current and temperature for narrow water trees was visualized and validated using the distribution plots. This study has led to a better understanding of the effect of cable temperature, water tree solution, and geometry of the tree region on cable degradation. Furthermore, this study has documented simulation results of water tree degradation in EPR MV cables, which had been previously lacking in information. Future work in this area will add frequency into the mix and examine what effect it has on the rate of cable degradation as a result of water treeing. To compliment the work being carried by UMD on different polymer chemistries, harvested medium voltage (MV) cables were selected for accelerated aging study at ORNL. These medium voltage cables are representative of the vintages and materials that are currently in use at existing nuclear power plants (NPPs). These cables were immersed in water at 90°C and energized for a period of two years at elevated voltage. Partial discharge was measured during this period of time to track potential degradation. Unfortunately, due to the absence of failure, the extent of integration between the UMD techniques and the harvested MV insulation was limited. However, based on the findings and from the UMD research in the previous sections on polyethylene and polypropylene, follow-on characterization for harvested MV cable insulation should focus on sample preparation to take advantage of the UMD techniques to better understand mechanistic degradation in MV cable insulations. This would include: 1.) Utilization of solutions and impedance measurement insulation to track permeability in harvested and accelerated aging insulation samples, 2.) Adaptation of gold nanoparticle synthesis for electrical impedance spectroscopy with supporting SEM characterization to study pore formation in harvested and accelerated aged insulation samples, & 3.) ATR-FTIR crystallinity with multiple temperature dependent harvested MV cable insulation under different air and submerged accelerated aging. In addition, low voltage dielectric spectroscopy and high voltage dissipation factor, tan δ, could be implemented as a condition monitoring tool for harvested MV cable insulation in submerged environments.

24 POWER TRANSMISSION AND DISTRIBUTION↗