Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VIDEO TAPES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

VICAR image processing system guide to system use

The functional characteristics and operating requirements of the VICAR (Video Image Communication and Retrieval) system are described. An introduction to the system describes the functional characteristics and the basic theory of operation. A brief description of the data flow as well as tape and disk formats is also presented. A formal presentation of the control statement formats is given along with a guide to usage of the system. The guide provides a step-by-step reference to the creation of a VICAR control card deck. Simple examples are employed to illustrate the various options and the system response thereto.

Seidman, J. B.↗

Photometric Calibration of Consumer Video Cameras

Equipment and techniques have been developed to implement a method of photometric calibration of consumer video cameras for imaging of objects that are sufficiently narrow or sufficiently distant to be optically equivalent to point or line sources. Heretofore, it has been difficult to calibrate consumer video cameras, especially in cases of image saturation, because they exhibit nonlinear responses with dynamic ranges much smaller than those of scientific-grade video cameras. The present method not only takes this difficulty in stride but also makes it possible to extend effective dynamic ranges to several powers of ten beyond saturation levels. The method will likely be primarily useful in astronomical photometry. There are also potential commercial applications in medical and industrial imaging of point or line sources in the presence of saturation.This development was prompted by the need to measure brightnesses of debris in amateur video images of the breakup of the Space Shuttle Columbia. The purpose of these measurements is to use the brightness values to estimate relative masses of debris objects. In most of the images, the brightness of the main body of Columbia was found to exceed the dynamic ranges of the cameras. A similar problem arose a few years ago in the analysis of video images of Leonid meteors. The present method is a refined version of the calibration method developed to solve the Leonid calibration problem. In this method, one performs an endto- end calibration of the entire imaging system, including not only the imaging optics and imaging photodetector array but also analog tape recording and playback equipment (if used) and any frame grabber or other analog-to-digital converter (if used). To automatically incorporate the effects of nonlinearity and any other distortions into the calibration, the calibration images are processed in precisely the same manner as are the images of meteors, space-shuttle debris, or other objects that one seeks to analyze. The light source used to generate the calibration images is an artificial variable star comprising a Newtonian collimator illuminated by a light source modulated by a rotating variable neutral- density filter. This source acts as a point source, the brightness of which varies at a known rate. A video camera to be calibrated is aimed at this source. Fixed neutral-density filters are inserted in or removed from the light path as needed to make the video image of the source appear to fluctuate between dark and saturated bright. The resulting video-image data are analyzed by use of custom software that determines the integrated signal in each video frame and determines the system response curve (measured output signal versus input brightness). These determinations constitute the calibration, which is thereafter used in automatic, frame-by-frame processing of the data from the video images to be analyzed.

Suggs, Robert↗

Photogrammetric evaluation of Mariner 9 photography

Some attempts to produce, with an AP/C analytical plotter, stereo models using Mariner 9 pictures are reported. The first attempt using geometrically uncorrected mission test video system (MTVS) imagery failed; the second, using corrected reduced data record (RDR) pictures also failed, probably because they were reconstructed through a vidicon display which introduces additional distortion. By using images obtained from RDR tape data through the Optronics Photowrite device, models were successfully obtained.

Wu, S. S. C.↗

STS-74 Mission Highlights Resource Tape

The flight crew of the STS-74 Space Shuttle Orbiter Atlantis Cmdr. Ken Cameron, Pilot Jim Halsell, and Mission Specialists Chris Hadfield, Jerry Ross, and William McArthur present an overview of their flight mission, whose primary objective is the rendezvous and space docking with the Russian Mir Space Station. Video film footage includes the following: prelaunch and launch activities; shuttle launch; in-orbit rendezvous; installation of the Russian-made docking module; in-orbit docking between Mir and the orbiter; general crew activities; transfer of supplies, equipment, and a crystal growth experiment to Mir; data collection from Mir thruster firings; undocking maneuvers and a Mir fly around; pre-return checkout of flight systems; and the reentry and landing of the orbiter. Earth views include horizon sunsets, atmospheric boundary layers, and a variety of geographical location footage (New Orleans; Atlanta; James Bay, Canada; Poland; Turkey; Mt. Pinatubo, Philippines; Salt Lake City, Utah; and Colorado).

Source record↗

Autoguidance video sensor for docking

The Automated Rendezvous and Docking system (ARAD) is composed of two parts. The first part is the sensor which consists of a video camera ringed with two wavelengths of laser diode. The second part is a standard Remote Manipulator System (RMS) target used on the Orbiter that has been modified with three circular pieces of retro-reflective tape covered by optical filters which correspond to one of the wavelengths of laser diode. The sensor is on the chase vehicle and the target is on the target vehicle. The ARAD system works by pulsing one wavelength laser diodes and taking a picture. Then the second wavelength laser diodes are pulsed and a second picture is taken. One picture is subtracted from the other and the resultant picture is thresholded. All adjacent pixels above threshold are blobbed together (X and Y centroids calculated). All blob centroids are checked to recognize the target out of noise. Then the three target spots are windowed and tracked. The three target spot centroids are used to evaluate the roll, yaw, pitch, range, azimuth, and elevation. From that a guidance routine can guide the chase vehicle to dock with the target vehicle with the correct orientation.

Book, Michael L.↗

STS-86 Mission Highlights Resource Tape

The flight crew of the STS-86 mission, Cmdr. James D. Wetherbee, Jr., Pilot Michael J. Bloomfield, Mission Specialists Scott E. Parazynski, Jean-Loup Chretien, Vladmir G. Titov, Wendy B. Lawrence and Mike Foale present an overview of their mission, whose primary objective is the rendezvous and space docking with the Russian Space Station Mir. Video film footage includes: prelaunch and launch activities; shuttle launch; in-orbit rendezvous; docking between Mir and the orbiter; general crew activities; transfer of supplies; undocking maneuvers and a Mir fly-around; and the reentry and landing of the orbiter.

Source record↗

Investigation of correlation classification techniques

A two-step classification algorithm for processing multispectral scanner data was developed and tested. The first step is a single pass clustering algorithm that assigns each pixel, based on its spectral signature, to a particular cluster. The output of that step is a cluster tape in which a single integer is associated with each pixel. The cluster tape is used as the input to the second step, where ground truth information is used to classify each cluster using an iterative method of potentials. Once the clusters have been assigned to classes the cluster tape is read pixel-by-pixel and an output tape is produced in which each pixel is assigned to its proper class. In addition to the digital classification programs, a method of using correlation clustering to process multispectral scanner data in real time by means of an interactive color video display is also described.

Haskell, R. E.↗

ISS Squat and Deadlift Kinematics on the Advanced Resistive Exercise Device

Visual assessment of exercise form on the Advanced Resistive Exercise Device (ARED) on orbit is difficult due to the motion of the entire device on its Vibration Isolation System (VIS). The VIS allows for two degrees of device translational motion, and one degree of rotational motion. In order to minimize the forces that the VIS must damp in these planes of motion, the floor of the ARED moves as well during exercise to reduce changes in the center of mass of the system. To help trainers and other exercise personnel better assess squat and deadlift form a tool was developed that removes the VIS motion and creates a stick figure video of the exerciser. Another goal of the study was to determine whether any useful kinematic information could be obtained from just a single camera. Finally, the use of these data may aid in the interpretation of QCT hip structure data in response to ARED exercises performed in-flight. After obtaining informed consent, four International Space Station (ISS) crewmembers participated in this investigation. Exercise was videotaped using a single camera positioned to view the side of the crewmember during exercise on the ARED. One crewmember wore reflective tape on the toe, heel, ankle, knee, hip, and shoulder joints. This technique was not available for the other three crewmembers, so joint locations were assessed and digitized frame-by-frame by lab personnel. A custom Matlab program was used to assign two-dimensional coordinates to the joint locations throughout exercise. A second custom Matlab program was used to scale the data, calculate joint angles, estimate the foot center of pressure (COP), approximate normal and shear loads, and to create the VIS motion-corrected stick figure videos. Kinematics for the squat and deadlift vary considerably for the four crewmembers in this investigation. Some have very shallow knee and hip angles, and others have quite large ranges of motion at these joints. Joint angle analysis showed that crewmembers do not return to a normal upright stance during squat, but remain somewhat bent at the hips. COP excursions were quite large during these exercises covering the entire length of the base of support in most cases. Anterior-posterior shear was very pronounced at the bottom of the squat and deadlift correlating with a COP shift to the toes at this part of the exercise. The stick figure videos showing a feet fixed reference frame have made it visually much easier for exercise personnel and trainers to assess exercise kinematics. Not returning to fully upright, hips extended position during squat exercises could have implications for the amount of load that is transmitted axially along the skeleton. The estimated shear loads observed in these crewmembers, along with a concomitant reduction in normal force, may also affect bone loading. The increased shear is likely due to the surprisingly large deviations in COP. Since the footplate on ARED moves along an arced path, much of the squat and deadlift movement is occurring on a tilted foot surface. This leads to COP movements away from the heel. The combination of observed kinematics and estimated kinetics make squat and deadlift exercises on the ARED distinctly different from their ground-based counterparts. CONCLUSION This investigation showed that some useful exercise information can be obtained at low cost, using a single video camera that is readily available on ISS. Squat and deadlift kinematics on the ISS ARED differ from ground-based ARED exercise. The amount of COP shift during these exercises sometimes approaches the limit of stability leading to modifications in the kinematics. The COP movement and altered kinematics likely reduce the bone loading experienced during these exercises. Further, the stick figure videos may prove to be a useful tool in assisting trainers to identify exercise form and make suggestions for improvements

Newby, N.↗

STS-71 Mission Highlights Resources Tape

The flight crew of the STS-71 Space Shuttle Orbiter Atlantis Commander Robert L. Gibson, Pilot Charles J. Precourt, Mission Specialists, Ellen S. Baker, Bonnie J. Dunbar, Gregory J. Harbaugh, and Payload Specialists, Norman E. Thagard, Vladimir Dezhurov, and Gennadiy Strekalov present an overview of their mission. It's primary objective is the first Mir docking with a space shuttle and crew transfer. Video footage includes the following: prelaunch and launch activities; the crew eating breakfast; shuttle launch; on orbit activities; rendezvous with Mir; Shuttle/Mir joint activities; undocking; and the shuttle landing.

Source record↗

Complementary code and digital filtering for detection of weak VHF radar signals from the mesoscale

The SOUSY-VHF-Radar operates at a frequency of 53.5 MHz in a valley in the Harz mountains, Germany, 90 km from Hanover. The radar controller, which is programmed by a 16-bit computer holds 1024 program steps in core and controls, via 8 channels, the whole radar system: in particular the master oscillator, the transmitter, the transmit-receive-switch, the receiver, the analog to digital converter, and the hardware adder. The high-sensitivity receiver has a dynamic range of 70 dB and a video bandwidth of 1 MHz. Phase coding schemes are applied, in particular for investigations at mesospheric heights, in order to carry out measurements with the maximum duty cycle and the maximum height resolution. The computer takes the data from the adder to store it in magnetic tape or disc. The radar controller is programmed by the computer using simple FORTRAN IV statements. After the program has been loaded and the computer has started the radar controller, it runs automatically, stopping at the program end. In case of errors or failures occurring during the radar operation, the radar controller is shut off caused either by a safety circuit or by a power failure circuit or by a parity check system.

Schmidt, G.↗

Delta/Wind Launch with Isolated Cameras from Continuous Recording

The Wind spacecraft represents one of NASA's contributions to the International Solar Terrestrial Program (ISTP), an international effort to quantify the effects of solar energy on the Earth's magnetic field. Wind will provide continuous measurement of the solar wind, particularly charged particles and magnetic field data. The specific objectives of Wind are to: (1) provide complete plasma, energetic particle, and magnetic field input for magnetospheric and ionospheric studies; (2) determine the magnetospheric output to interplanetary space in the upstream region; (3) investigate basic plasma processes occurring in the near-Earth solar wind; and (4) provide baseline ecliptic plane observations to be used in heliospheric studies. This videotape shows the pre-dawn launch of the Wind spacecraft aboard a Delta 7925 on November 1, 1994. After the countdown and launch, the tape shows the activity in the Telemetry Room at Kennedy Space Center, where people are following the progress of the spacecraft. Following the activity in the telemetry room, there are four different replays of the launch from different locations. After showing the replays of the launch, the video returns to the Telemetry Room when an important stage in the launch and flight is achieved.

Source record↗

Simulation of the Effects of Hard Limiting on Image Quality of Synthetic Aperture Radar

Starting with a magnetic tape of a scene viewed by the Landsat satellite, the radar return of reflectors whose average intensity matched that of the picture elements in the scene has been simulated. The returns were processed in three ways: normally or with no quantization, with a procedure simulation IF hard limiting, and with a procedure simulating video (baseband) hard limiting. For each type of processing an image for a one, two, and four-look system has been developed. It was found that IF limiting is slightly better than video limiting, while both can be reasonable trade-offs of image quality for reduced data rates when the number of looks is four or less. These conclusions are supported by photographs representing the different processing techniques.

Lipes, R. G.↗

Low noise imaging photon counter for astronomy

The characteristics and performance of a Ranicon photon-counting system combined with digital tape recording are described. The most important features are a bialkali photocathode response over 256 X 256 digital pixels, with approximately 100 X 100 resolvable pixels at 50% MTF, a dead time of 16 microsec/count, a maximum recordable count rate of 14,400/sec, and a background of less than 1 count/digital pixel/h. A video cassette recorder serves for the digital recording which retains the temporal sequence of the registered photons. Astronomical applications will include low light level quantitative imaging and speckle imaging.

Mertz, L.↗

Getting the Bigger Picture With Digital Surveillance

Through a Space Act Agreement, Diebold, Inc., acquired the exclusive rights to Glenn Research Center's patented video observation technology, originally designed to accelerate video image analysis for various ongoing and future space applications. Diebold implemented the technology into its AccuTrack digital, color video recorder, a state-of- the-art surveillance product that uses motion detection for around-the- clock monitoring. AccuTrack captures digitally signed images and transaction data in real-time. This process replaces the onerous tasks involved in operating a VCR-based surveillance system, and subsequently eliminates the need for central viewing and tape archiving locations altogether. AccuTrack can monitor an entire bank facility, including four automated teller machines, multiple teller lines, and new account areas, all from one central location.

Source record↗

Digital data processing of ERTS-1 imagery of Delaware Bay

A user-oriented Earth Resources Data Center is in operation at Bendix Aerospace, which a capable of automatically producing classification imagery and thematic maps from ERTS computer compatible tapes. The ERDC is now being used to process ERTS-1 data under a subcontract from the University of Delaware. ERTS coverage of Delaware Bay has been processed to produce classification imagery of water masses in the bay, and a map of all land-water boundaries along the shoreline including wetlands and inland lakes. Imagery, the user's video monitor color display, the data processing facility, and methodology are described.

Conrod, A. C.↗

The 19 mm data recorders similarities and differences

Confusion over the use of non-video 19 mm data recorders is becoming more pronounced as we enter the world of high performance computing. This paper addresses the following: the differences between ID-1, ID-2, MIL-STD-2179 and DD-2; what the proper machine is for various applications; how the machine can be integrated into an environment; and any misconceptions there might be about 19 mm tape recorders. DD-2 and 19 mm instrumentation recorders have missions for which each is well designed. While the differences may appear subtle, understanding the difference between the two is the key to picking the right recorder for a particular application.

Atkinson, Steve↗

FIDO - Video File

Field Integrated Design and Operations (FIDO) rover is a prototype of the Mars Sample Return rovers that will carry the integrated Athena Science Payload to Mars in 2003 and 2005. The purpose of FIDO is to simulate, using Mars analog settings, the complex surface operations that will be necessary to find, characterize, obtain, cache, and return samples to the ascent vehicles on the landers. This videotape shows tests of the FIDO in the Mojave Desert. These tests include drilling through rock and movement of the rover. Also included in this tape are interviews with Dr Raymond Arvidson, the test director for FIDO, and Dr. Eric Baumgartner, Robotics Engineer at the Jet Propulsion Laboratory.

Source record↗

The 19 mm date recorders: Similarities and differences

Confusion over the use of non-video 19 mm data recorders is becoming more pronounced in the world of high performance computing. The following issues are addressed: (1) the difference between ID-1, ID-2, MIL-STD-2179, and DD-2; (2) the proper machine for the necessary application; and (3) integrating the machine into an existing environment. Also, an attempt is made to clear up any misconceptions there might be about 19 mm tape recorders.

Atkinson, Steve↗