Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VASCULAR DISEASES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Transluminal Angioplasty of Peroneal Artery Branches in Diabetics: Initial Technical Experience

The present study aimed to report the technical feasibility of percutaneous transluminal angioplasty (PTA) of obstructed or insufficient collateral branches (anterior and posterior perforating branches) from distal peroneal to foot arteries in diabetic patients with chronic critical limb ischemia (CLI) and chronic noncrossable occlusion of the anterior and posterior tibial arteries. Twenty-four diabetic CLI patients (age, 67 {+-} 8 years; 87% males) undergoing collateral PTA were included. Baseline clinical angiographic and follow-up data were retrospectively reviewed. Collateral PTA was associated with a concomitant PTA of other sites in 21 (83%) cases. In 15 cases the treated collateral linked the peroneal with the plantaris communis; in 9 cases, the peroneal with the dorsalis pedis. Angiographic results of collateral PTA were good in 13 cases (<30% residual stenosis), whereas the result was considered moderate (30%-49% residual stenosis) in the remaining cases. Neither perforation nor acute occlusion of the treated collaterals or other relevant complications were observed. Mean follow-up was 32 {+-} 17 months. Major amputation was necessary for two (8.3%) patients. Cumulative limb salvage rates at 2 and 4 years were 96% and 87%, respectively. In conclusion, this initial experience shows that PTA of the collateral branches from distal peroneal to foot arteries is a feasible technique. Future studies are required to define the clinical role of this novel approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Acute Liver Failure After a Late TIPSS Revision

We report a rare case of late transjugular intrahepatic portosystemic stent shunt (TIPSS) occlusion due to progressive stent protrusion into the periportal liver parenchyma, which was a result of delayed liver shrinkage 2 years after TIPSS. The initial TIPSS procedure had been carried out in a 52-year-old man as a bridge for liver transplantation because of post-alcoholic liver cirrhosis. We describe the applied TIPSS recanalization and revision technique. Immediately after TIPSS revision acute liver failure developed, which required emergency liver transplantation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Modified Metallic Coil Embolization Technique for Pulmonary Arteriovenous Malformations Using Coil Anchors and Occlusion Balloon Catheters

Purpose. To evaluate the feasibility and efficacy of a modified metallic coil embolization technique for pulmonary arteriovenous malformations (PAVMs) using coil anchors and occlusion balloon catheters. Methods. Five consecutive female patients with 6 PAVMs were included in the present study. One of the 6 PAVMs was of the complex type with four feeding arteries. An occlusion balloon catheter was inserted into the feeding artery as close to the venous sac as possible. The coil anchor, which was a simple W-shaped bent stainless steel wire with two markers at each end, was deployed prior to embolization to prevent the systemic migration of embolic materials. Then, metallic coils were deployed around the coil anchors under inflow stoppage using the inflated occlusion balloon catheter. In the complex-type PAVM, the main feeder was occluded by this technique and the other three small feeders were embolized with metallic coils only. Results. In all 5 cases, occlusion balloon catheters could be inserted into the feeding arteries just proximal to the venous sacs, coil anchors were easily deployed, and complete occlusion was achieved without any migration of metallic coils or paradoxical embolism during the procedure. Conclusions. The modified metallic coil embolization technique with coil anchors and occlusion balloon catheters was feasible and considered to be useful in preventing procedure-related complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transcatheter Coil Embolization of Splenic Artery Aneurysm

The purpose of this study was to evaluate clinical results and technical problems of transcatheter coil embolization for splenic artery aneurysm. Subjects were 16 patients (8 men, 8 women; age range, 40-80 years) who underwent transcatheter embolization for splenic artery aneurysm (14 true aneurysms, 2 false aneurysms) at one of our hospitals during the period January 1997 through July 2005. Two aneurysms (12.5%) were diagnosed at the time of rupture. Multiple splenic aneurysms were found in seven patients. Aneurysms were classified by site as proximal (or strictly ostial) (n = 3), middle (n = 3), or hilar (n = 10). The indication for transcatheter arterial embolization was a false or true aneurysm 20 mm in diameter. Embolic materials were fibered coils and interlocking detachable coils. Embolization was performed by the isolation technique, the packing technique, or both. Technically, all aneurysms were devascularized without severe complications. Embolized aneurysms were 6-40 mm in diameter (mean, 25 mm). Overall, the primary technical success rate was 88% (14 of 16 patients). In the remaining 2 patients (12.5%), partial recanalization occurred, and re-embolization was performed. The secondary technical success rate was 100%. Seven (44%) of the 16 study patients suffered partial splenic infarction. Intrasplenic branching originating from the aneurysm was observed in five patients. We conclude that transcatheter coil embolization should be the initial treatment of choice for splenic artery aneurysm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Is the Use of Fullerene in Photodynamic Therapy Effective for Atherosclerosis?

The purpose of this study was to evaluate Fullerene as a therapeutic photosensitizer in the treatment of atherosclerosis. An atherosclerotic experimental rabbit model was prepared by causing intimal injury to bilateral external iliac arteries using balloon expansion. In four atherosclerotic rabbits and one normal rabbit, polyethylene glycol-modified Fullerene (Fullerene-PEG) was infused into the left external iliac artery and illuminated by light emitting diode (LED), while the right external iliac artery was only illuminated by LED. Two weeks later, the histological findings for each iliac artery were evaluated quantitatively and comparisons were made among atherosclerotic Fullerene+LED artery (n = 4), atherosclerotic light artery (n = 4), normal Fullerene+LED artery (n = 1), and normal light artery (n = 1). An additional two atherosclerotic rabbits were studied by fluorescence microscopy, after Fullerene-PEG-Cy5 complex infusion into the left external iliac artery, for evaluation of Fullerene-PEG incorporated within the atherosclerotic lesions. The degree of atherosclerosis in the atherosclerotic Fullerene+LED artery was significantly (p < 0.05) more severe than that in the atherosclerotic LED artery. No pathological change was observed in normal Fullerene+LED and LED arteries. In addition, strong accumulation of Fullerene-PEG-Cy5 complex within the plaque of the left iliac artery of the two rabbits was demonstrated, in contrast to no accumulation in the right iliac artery. We conclude that infusion of a high concentration of Fullerene-PEG followed by photo-illumination resulted not in a suppression of atherosclerosis but in a progression of atherosclerosis in experimental rabbit models. However, this intervention showed no adverse effects on the normal iliac artery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Need for Anticoagulation Following Inferior Vena Cava Filter Placement: Systematic Review

Purpose. To perform a systemic review to determine the effect of anticoagulation on the rates of venous thromboembolism (pulmonary embolus, deep venous thrombosis, inferior vena cava (IVC) filter thrombosis) following placement of an IVC filter. Methods. A comprehensive computerized literature search was performed to identify relevant articles. Data were abstracted by two reviewers. Studies were included if it could be determined whether or not subjects received anticoagulation following filter placement, and if follow-up data were presented. A meta-analysis of patients from all included studies was performed. A total of 14 articles were included in the final analysis, but the data from only nine articles could be used in the meta-analysis; five studies were excluded because they did not present raw data which could be analyzed in the meta-analysis. A total of 1,369 subjects were included in the final meta-analysis. Results. The summary odds ratio for the effect of anticoagulation on venous thromboembolism rates following filter deployment was 0.639 (95% CI 0.351 to 1.159, p = 0.141). There was significant heterogeneity in the results from different studies [Q statistic of 15.95 (p = 0.043)]. Following the meta-analysis, there was a trend toward decreased venous thromboembolism rates in patients with post-filter anticoagulation (12.3% vs. 15.8%), but the result failed to reach statistical significance. Conclusion. Inferior vena cava filters can be placed in patients who cannot receive concomitant anticoagulation without placing them at significantly higher risk of development of venous thromboembolism.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Aneurysm Sac Pressure Measurement with Minimally Invasive Implantable Pressure Sensors: An Alternative to Current Surveillance Regimes after EVAR?

Current protocols for surveillance after endovascular repair (EVAR) of abdominal aortic aneurysms are mostly based on costly and time-consuming imaging procedures and aim to detect adverse events such as graft migration, endoleaks or aneurysm sac enlargement. These imaging procedures are either associated with radiation exposure to the patients or may be harmful to the patient due to the use of iodine- or gadolinium-containing contrast agents. Furthermore the advantages of EVAR in the short term might be negated by the necessity for endograft surveillance over years. Thus, alternative modalities for follow-up are being investigated. One of these technologies provides pressure information directly from the aneurysm sac. This noninvasive, telemetric pressure sensing was tested in vitro as well as in first clinical trials and was able to identify successful aneurysm exclusion after EVAR. The telemetric pressure sensors showed a promising efficacy and accuracy in detecting type I and type III endoleaks and will help to clarify the clinical relevance of type II endoleaks. This article provides an overview of the in vitro sensors investigated as well as the first clinical trials and the sensors' potential to change the current endograft surveillance regimes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Coil Protruding into the Common Femoral Vein Following Pelvic Venous Embolization

Pelvic venous embolization is performed for pelvic congestion syndrome and prior to lower limb varicose vein surgery in females with associated pelvic venous insufficiency. The procedure is analogous to varicocele embolization in males, although refluxing internal iliac vein tributaries may also be embolized. We report a case of inadvertent coil placement in the common femoral vein while embolizing the obturator vein, during pelvic vein embolization for recurrent lower limb varicose veins. There were no clinical consequences and the coil was left in situ. We advise caution when embolizing internal iliac vein tributaries where there is clinically significant communication with veins of the lower limb.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long-Term Follow-up After Embolization of Pulmonary Arteriovenous Malformations with Detachable Silicone Balloons

Long-term follow-up results after embolization of 13 pulmonary arteriovenous malformations in 10 patients by use of 14 detachable silicone balloons are given. Patients were followed for a mean of 99 months (range, 63-123 months) with chest x-rays and for a mean of 62 months (range, 3-101 months) with pulmonary angiography. Fifty-four percent of the balloons were deflated at latest radiographic chest film follow-up, but at pulmonary angiographic follow-up all embolized malformations were without flow irrespective of whether or not the balloons were visible. Detachable silicone balloons are not available anymore, but use of these balloons for embolization of pulmonary arteriovenous malformations has been shown to be a safe and precise method, with immediate occlusion of the feeding artery and with long-lasting occlusion, even though many balloons deflate with time, leaving a fibrotic scar replacing the pulmonary arteriovenous malformation. No case of recanalization has been discovered, and these results seem to justify a reduced number of controls of these balloon-embolized malformations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Is Internal Iliac Artery Embolization Essential Prior to Endovascular Repair of Aortoiliac Aneurysms?

Patients who undergo endovascular repair of aorto-iliac aneurysms (EVAR) require internal iliac artery (IIA) embolization (IIAE) to prevent type II endoleaks after extending the endografts into the external iliac artery. However, IIAE may not be possible in some patients due to technical factors or adverse anatomy. The aim of this study was to assess retrospectively whether patients with aorto-iliac aneurysms who fail IIAE have an increase in type II endoleak after EVAR compared with similar patients who undergo successful embolization. We retrospectively analyzed the records of 148 patients who underwent EVAR from December 1997 to June 2005. Sixty-one patients had aorto-iliac aneurysms which required IIAE before EVAR. Fifty patients had successful IIAE and 11 patients had unsuccessful IIAE prior to EVAR. The clinical and imaging follow-up was reviewed before and after EVAR. The endoleak rate of the embolized group was compared with that of the group in whom embolization failed. After a mean follow-up of 19.7 months in the study group and 25 months in the control group, there were no statistically significant differences in outcome measures between the two groups. Specifically, there were no type II endoleaks related to the IIA in patients where IIAE had failed. We conclude that failure to embolize the IIA prior to EVAR should not necessarily preclude patients from treatment. In patients where there is difficulty in achieving coil embolization, it is recommended that EVAR should proceed, as clinical sequelae are unlikely.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pulmonary Artery Access Embolization in Patients with Massive Hemoptysis in Whom Bronchial and/or Nonbronchial Systemic Artery Embolization Is Contraindicated

The objective of this paper is to present an alternative therapeutic approach for the treatment of patients with massive hemoptysis in whom bronchial and/or nonbronchial systemic arterial embolization is not possible. We describe a percutaneous procedure for pulmonary segmental artery embolization. Between May 2000 and July 2006, 27 adult patients with hemoptysis underwent percutaneous treatment at our department; 20 of 27 patients were embolized via bronchial and or nonbronchial systemic arteries and 7 patients were embolized via pulmonary artery. Femoral arterial access for systemic artery catheterization and femoral vein access for pulmonary arterial catheterization were used. Gelfoam particles and coils were used for embolization. In this study, we report on three cases of massive hemoptysis from a systemic arterial source in whom bronchial and/or nonbronchial arteries embolization was not possible. Percutaneous embolization via the pulmonary artery access was successful in all three patients. In conclusion, embolization via pulmonary artery is presented as an alternative approach for the management of hemoptysis in patients in whom bronchial arterial embolization is not possible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Drug-Loaded Microspheres for the Treatment of Liver Cancer: Review of Current Results

Transarterial chemoembolization (TACE) involves the emulsification of a chemotherapeutic agent in a viscous drug carrier, delivered intra-arterially to liver tumor for maximum effect. TACE reduces arterial inflow, diminishes washout of the chemotherapeutic agent, and decreases systemic exposure. Despite evidence of some clinical success with TACE, a new type of microspheres with drug-eluting capabilities may offer a precisely controlled and sustainable release of the chemotherapeutic agent into the tumor bed. In animal trials tumor necrosis (approaching 100%) was greatest at 7 days, with significantly lower plasma concentrations of doxorubicin than in control animals treated with doxorubicin intra-arterially. Clinically, drug-eluting microspheres loaded with doxorubicin, either at 75 mg/m{sup 2} or at a fixed dose of 150 mg, were used recently and no severe disorders of the hepatic function were observed postprocedure, while a substantial reduction of the fetoprotein levels occurred. An interim analysis of the first 15 patients from the Hong Kong group at 3 months showed an objective response rate of 61.54% and 53.84% according to EASL criteria and RECIST criteria, respectively, and a survival rate of 93.3%. In this paper we present how to use microspheres loaded with doxorubicin and review their clinical value and preliminary performance for treatment of unresectable liver cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Efficacy and Safety of the Angioseal Vascular Closure Device Post Antegrade Puncture

In this study, the efficacy and safety of the Angioseal vascular closure device post antegrade puncture of the common femoral artery (CFA) for lower limb vascular interventional procedures are evaluated. A retrospective analysis of the medical records of 60 consecutive patients who were referred for interventional procedures in the superficial femoral artery (SFA) or popliteal artery (popl. art.) was performed. Antegrade puncture was successfully performed in 58 of 60 patients (96.6%). Indications included right SFA angioplasty (n = 35), left SFA angioplasty (n = 17), right popl. art. angioplasty (n = 5), and left popl. art. angioplasty (n = 1). Hemostasis was achieved by, on an intention-to-treat basis, the Angioseal vascular closure device in 46 patients and manual compression in 12 patients. Manual compression was used instead of Angioseal because of severe calcified arterial wall plaques (n = 7), failed deployment of the Angioseal (n = 4), and left SFA dissection (n = 1). There were no major recorded complications in the Angioseal group despite the use of antiplatelet or anticoagulant medications. Twenty-three (50%) of the patients in the Angioseal group were discharged within 24 h. Thirty-seven of the 46 patients who received an Angioseal device had undergone a previous ipsilateral CFA puncture (time range, 2 days to 56 months; mean, 6.2 months). Nine of these patients had undergone ipsilateral Angioseal deployment in the previous 3 months. We conclude that the Angioseal vascular closure device is a safe and efficient means of achieving hemostasis post antegrade puncture.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measurement of Pleural Temperature During Radiofrequency Ablation of Lung Tumors to Investigate Its Relationship to Occurrence of Pneumothorax or Pleural Effusion

The purpose of this study was to investigate the relationship between pleural temperature and pneumothorax or pleural effusion after radiofrequency (RF) ablation of lung tumors. The pleural temperature was measured immediately outside the lung surface nearest to the tumor with a fiber-type thermocouple during 25 ablation procedures for 34 tumors in 22 patients. The procedures were divided into two groups depending on the highest pleural temperature: P-group I and P-group II, with highest pleural temperatures of <40 deg. C and {>=}40 deg. C, respectively. The incidence of pneumothorax or pleural effusion was compared between the groups. Multiple variables were compared between the groups to determine the factors that affect the pleural temperature. The overall incidence of pneumothorax and pleural effusion was 56% (14/25) and 20% (5/25), respectively. Temperature data in five ablation procedures were excluded from the analyses because these were affected by the pneumothorax. P-group I and P-group II comprised 10 procedures and 10 procedures, respectively. The incidence of pleural effusion was significantly higher in P-group II (4/10) than in P-group I (0/10) (p = 0.043). However, the incidence of pneumothorax did not differ significantly (p = 0.50) between P-group I (4/10) and P-group II (5/10). Factors significantly affecting the pleural temperature were distance between the electrode and the pleura (p < 0.001) and length of the lung parenchyma between the electrode and the pleura (p < 0.001). We conclude that higher pleural temperature appeared to be associated with the occurrence of pleural effusion and not with that of pneumothorax.

62 RADIOLOGY AND NUCLEAR MEDICINE↗