Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Thermal Sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

A 4 K cryogenic probe for use in magnetic resonance force microscopy experiments

The detailed design of a mechanically detected nuclear magnetic resonance probe using the SPAM (Springiness Preservation by Aligning Magnetization) geometry, operating at 4 K, in vacuum, and a several-Tesla magnetic field is described. The probe head is vibration-isolated well enough from the environment by a three-spring suspension system that the cantilever achieves thermal equilibrium with the environment without the aid of eddy current damping. The probe uses an ultra-soft Si cantilever with a Ni sphere attached to its tip, and magnetic resonance is registered as a change in the resonant frequency of the driven cantilever. The RF system uses frequency sweeps for adiabatic rapid passage using a 500 μm diameter RF coil wound around a sapphire rod. The RF coil and optical fiber of the interferometer used to sense the cantilever's position are both located with respect to the cantilever using a Garbini micropositioner, and the sample stage is mounted on an Attocube nanopositioner.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Arctic Clouds Infrared Imaging Field Campaign Report

The Infrared Cloud Imager (ICI), a passive thermal imaging system, was deployed at the North Slope of Alaska site in Barrow, Alaska, from July 2012 to July 2014 for measuring spatial-temporal cloud statistics. Thermal imaging of the sky from the ground provides high radiometric contrast during night and polar winter when visible sensors and downward-viewing thermal sensors experience low contrast. In addition to demonstrating successful operation in the Arctic for an extended period and providing data for Arctic cloud studies, a primary objective of this deployment was to validate novel instrument calibration algorithms that will allow more compact ICI instruments to be deployed without the added expense, weight, size, and operational difficulty of a large-aperture onboard blackbody calibration source. This objective was successfully completed with a comparison of the two-year data set calibrated with and without the onboard blackbody. The two different calibration methods produced daily-average cloud amount data sets with correlation coefficient = 0.99, mean difference = 0.0029 (i.e., 0.29% cloudiness), and a difference standard deviation = 0.054. Finally, the ICI instrument generally detected more thin clouds than reported by other ARM cloud products available as of late 2015.

54 ENVIRONMENTAL SCIENCES↗

Diamond as a solid state micro-fission chamber for thermal neutron detection at the VR-1 research reactor

Diamond exhibits a combination of properties which makes it attractive for neutron detection in hostile conditions. In the particular case of detection in a nuclear reactor, it is resilient to radiation, exhibits a natural low sensitivity to gamma rays, and its small size (as compared with that of gas ionisation chambers) enables fluency monitoring with a high position resolution. We report here on the use of synthetic CVD diamond as a solid state micro-fission chamber with U-235 converting material for in-core thermal neutron monitoring. Two types of thin diamond detectors were developed for this application. The first type of detector is fabricated using thin diamond membrane obtained by etching low-cost commercially available single crystal CVD intrinsic diamond, so called 'optical grade' material. Starting from a few hundred of micrometre thick samples, the sample is sliced with a laser and then plasma etched down to a few tenths of micrometre. Here we report the result obtained with a 17 μm thick device. The detection surface of this detector is equal to 1 mm{sup 2}. Detectors with surfaces up to 1 cm{sup 2} can be fabricated with this technique. The second type of detector is fabricated by growing successively two thin films of diamond, by the microwave enhanced chemical vapour deposition technique, on HPHT single crystal diamond. A first, a film of boron doped (p+) single crystal diamond, a few microns thick, is deposited. Then a second film of intrinsic diamond with a thickness of a few tens of microns is deposited. This results in a P doped, Intrinsic, Metal structure (PIM) structure in which the intrinsic volume id the active part of the detector. Here we report the results obtained with a 20 μm thick intrinsic whose detection surface is equal to 0.5 mm{sup 2}, with the possibility to enlarge the surface of the detector up to 1 cm{sup 2}. These two types of detector were tested at the VR-1 research reactor at the Czech Technical University in Prague. The Training Reactor VR-1 is a pool type (light water) reactor based on UO{sub 2} low enriched uranium. It has a nominal power of 1 kW, and can be operated for a short period up to 5 kW. The arrangement of the reactor pool reactor facilitates access to the core, setting and removal of various experimental samples and detectors, and safe and easy handling of fuel assemblies. The reactor is equipped with two horizontal channels (radial and tangential) and 10 vertical channels, of varying diameters, which can be loaded into various core positions, and one pneumatic transfer system. It is also equipped with several specifically designed educational instrumentation systems that can be used to supply complementary measurements and characterization around the reactor. The reactor is operated by the Department of Nuclear Reactors of the Faculty of Nuclear Sciences and Physical Engineering of the Czech Technical University in Prague. The two detectors were placed in-core through one of the vertical insertion channel. They were coupled to remote placed (5 m BNC cable) classical nuclear charge sensitive electronics. Detection properties of both sensors, including: pulse height spectra of U-235 fission fragments (response linearity with neutron flux, count rate, gamma background, were evaluated varying the power of the reactor from 0.005 W to 500 W. The evolution of the counting rate of the thinned optical grade detector as a function of counting rate of a gas ionization chamber used currently for reactor monitoring shows the very good linearity of the detector over the 5 decades. Similar results were obtained with the PIM detector. Additionally fast transient current signals of the detectors were recorded on a digital storage oscilloscope (DSO) using broad-band amplifier and with a simple bias-T, showing potential use of such sensors for neutron counting with no need of an amplification stage, since non-amplified signals from fission fragments exceeded 4 mV in amplitude. Therefore, one can think of simple neutron counting system by feeding diamond detectors signals directly to the low threshold discriminators. The results obtained on the VR1 will be described and discussed in detail in the paper and associated presentation. The results demonstrate that diamond micro-fission chambers can be used for in-core neutron monitoring, where robust, simple and compact devices are required.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

CdSe/ZnS quantum dot fluorescence spectra shape-based thermometry via neural network reconstruction

As a system of interest gets small, due to the influence of the sensor mass and heat leaks through the sensor contacts, thermal characterization by means of contact temperature measurements becomes cumbersome. Non-contact temperature measurement offers a suitable alternative, provided a reliable relationship between the temperature and the detected signal is available. In this work, exploiting the temperature dependence of their fluorescence spectrum, the use of quantum dots as thermomarkers on the surface of a fiber of interest is demonstrated. The performance is assessed of a series of neural networks that use different spectral shape characteristics as inputs (peak-based—peak intensity, peak wavelength; shape-based—integrated intensity, their ratio, full-width half maximum, peak normalized intensity at certain wavelengths, and summation of intensity over several spectral bands) and that yield at their output the fiber temperature in the optically probed area on a spider silk fiber. Starting from neural networks trained on fluorescence spectra acquired in steady state temperature conditions, numerical simulations are performed to assess the quality of the reconstruction of dynamical temperature changes that are photothermally induced by illuminating the fiber with periodically intensity-modulated light. Comparison of the five neural networks investigated to multiple types of curve fits showed that using neural networks trained on a combination of the spectral characteristics improves the accuracy over use of a single independent input, with the greatest accuracy observed for inputs that included both intensity-based measurements (peak intensity) and shape-based measurements (normalized intensity at multiple wavelengths), with an ultimate accuracy of 0.29 K via numerical simulation based on experimental observations. The implications are that quantum dots can be used as a more stable and accurate fluorescence thermometer for solid materials and that use of neural networks for temperature reconstruction improves the accuracy of the measurement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Trimethylamine sensing properties of graphene quantum Dots/α-Fe{sub 2}O{sub 3} composites

Graphene quantum dots (GQDs) were prepared by pyrolysis of citric acid. The sizes of the as-prepared GQDs were in the range of 2–4 nm. The GQDs/α-Fe{sub 2}O{sub 3} composites were prepared by loading GQDs with α-Fe{sub 2}O{sub 3} via a one-step facile hydrothermal method. The GQDs/α-Fe{sub 2}O{sub 3} composites were characterized by XRD, TGA, FTIR, Raman, SEM and TEM, respectively. The sensor devices were fabricated using the GQDs/α-Fe{sub 2}O{sub 3} composites as sensing materials. The effect of the amount of GQDs in the composites on the gas-sensing responses of the materials and the gas-sensing selectivity was investigated. The experimental results revealed that the sensor based on GQDs/α-Fe{sub 2}O{sub 3} (S-15) composite exhibited high sensitivity and good selectivity to TMA vapor. The responses of the sensor based on GQDs/α-Fe{sub 2}O{sub 3} (S-15) composite to 1000 ppm and 0.01 ppm TMA vapor attained 1033.0 and 1.9 at 270 °C, respectively. The response time and recovery time for 0.01 ppm TMA vapor were only 6 s and 4 s, respectively. - Graphical abstract: (1) The sizes of the GQDs are in the range of 2–5 nm; (2) The responses of the sensor based on GQDs/α-Fe{sub 2}O{sub 3} (S-15) composite to 0.01, 0.1, 1, 10, 100 and 1000 ppm TMA vapor at 270 °C are 1.9, 2.9, 5.5, 15.4, 293.0 and 1033.0, respectively, and the detection limit can reach 0.01 ppm.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Heat flux sensor calibration using noninteger system identification: Theory, experiment, and error analysis

This paper concerns the improvement of the calibration technique of null point calorimeters generally used in high enthalpy plasma flows. Based on the linearity assumption, this technique leads to calculate the impulse response that relates the heat flux at the tip of the sensor according to the temperature at the embedded thermocouple close to the heated surface. The noninteger system identification (NISI) procedure is applied. The NISI technique had been well described in previous study. The present work focuses on the accuracy of the identified system in terms of absorbed heat flux during the calibration experiment and of the estimated parameters in the model. The impulse response is thus calculated along with its associated standard deviation. Furthermore, this response is compared with that of the one-dimensional semi-infinite medium, which is classically used in practical applications. The asymptotic behavior of the identified system at the short times is analyzed for a better understanding of the noninteger identified system. Finally, the technique was applied to a new sensor geometry that has been developed particularly for high enthalpy plasma flows and it is shown that the method can be applied to any geometry suitable for a certain test configuration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectroscopic determination of thermal impulse in sub-second heating events using lanthanide-doped oxide precursors and phenomenological modeling

Using a mixture of crystalline-Ho:ZrO{sub 2}, precursor-Dy:Y{sub 2}O{sub 3}, and precursor-Eu:ZrO{sub 2} nanoparticles we develop thermal impulse sensors capable of measuring equivalent isothermal temperatures and durations during a heating event, with response times of <100 ms, and a temperature range of at least 673 K to 1173 K. In order to determine the temperature and duration from the sensors after the heating event we measure the sensors' fluorescence spectrum, which is then compared with lab based calibration data. By using two precursor materials with different reaction kinetics we are able to extract both temperature and duration. Based on blind sample testing we find that the sensors and calculation method are accurate for measuring temperature and duration, but currently suffer a lack of precision due to difficulties in producing homogeneously heated samples.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Developing a robust sensor for infrared imaging bolometers

A new type of large area sensor for infrared imaging bolometers has been developed. It replaces the thin and fragile free-standing metal foils, which typically have been used, with a multi-layer coated sapphire (or diamond) substrate. Sapphire is transparent to mid-infrared wavelengths, is robust against transients, and can be thick enough to even be the vacuum window. The primary radiation absorber is still a thin deposited metal layer, but now it is partially insulated from the supporting sapphire substrate by a black (carbon-based) layer, which also acts as a blackbody remitter. Test results indicate 6× more noise equivalent power density (estimated NEPD = 23 W/m 2 at 5 ms camera exposure time, foil temperature decay time 60 ms) for a 2 μm gold-coated sapphire disk compared to estimated NEP = 4 W/m 2 at 1.8 ms exposure time, with foil decay time 420 ms, for a nominal 2.5 μm thick platinum-free-standing foil.

47 OTHER INSTRUMENTATION↗

Monte Carlo Dropout Uncertainty Quantification of Long Short-Term Memory Autoencoder Anomaly Detection in a Liquid Sodium Cold Trap

Advanced high-temperature fluid reactors, such as sodium-cooled fast reactors (SFRs) and molten salt–cooled reactors (MSCRs), require coolant purification systems to prevent fluid contamination and local freezing that can lead to plugging. Liquid sodium purification can be achieved with a cold trap, where the sodium temperature is reduced to a near-freezing point to precipitate out impurities. Automation of monitoring of the cold trap performance with machine learning algorithms can aid in early detection of incipient anomalies. An efficient approach to loss-of-coolant–type anomaly detection in a cold trap monitored with more than two dozen thermal-hydraulic sensors consists of a long short-term memory (LSTM) autoencoder. This work develops the uncertainty quantification of the LSTM autoencoder performance for cold trap anomaly detection using the Monte Carlo (MC) dropout method. The MC dropout methodology creates a distribution of sister distributions that all slightly differ from each other because of random neurons being turned off for testing. The variances of the sister network distributions are used to make an uncertainty interval. Our analysis shows that the uncertainty in the autoencoder performance is largest near the peak of the anomaly signal. Using the MC dropout method, we investigate the uncertainty in the anomaly detection with missing sensor inputs. This capability allows the reactor operator to evaluate resilience of the anomaly detection system and to make informed decisions about continuity of operation in the event of sensor failure.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Vision Foundation Models in Remote Sensing: A survey

Artificial intelligence (AI) technologies have profoundly transformed the field of remote sensing (RS), revolutionizing data collection, processing, and analysis. Traditionally reliant on manual interpretation and task-specific models, RS research has been significantly enhanced by the advent of foundation models (FMs)—large-scale pretrained AI models capable of performing a wide array of tasks with unprecedented accuracy and efficiency. This article provides a comprehensive survey of FMs in the RS domain. We categorize these models based on their architectures, pretraining datasets, and methodologies. Through detailed performance comparisons, we highlight emerging trends and the significant advancements achieved by those FMs. Additionally, we discuss technical challenges, practical implications, and future research directions, addressing the need for high-quality data, computational resources, and improved model generalization. Our research also finds that pretraining methods, particularly self-supervised learning (SSL) techniques like contrastive learning (CL) and masked autoencoders (MAEs), remarkably enhance the performance and robustness of FMs. This survey aims to serve as a resource for researchers and practitioners by providing a panorama of advances and promising pathways for the continued development and application of FMs in RS.

data models↗

Spincaloritronic Measurements: A Round Robin Comparison of the Longitudinal Spin Seebeck Effect

The rising field of spin caloritronics focuses on the interactions between spin and heat currents in a magnetic material; the observation of the spin Seebeck effect opened the route to this branch of research. This paper reports the results of a round robin test performed by five partners on a single device highlighting the reproducibility problems related to the measurements of the spin Seebeck coefficient, the quantity that describes the strength of the spin Seebeck effect. Here, this work stimulated the search for more reproducible measurement methods through the analysis of the systematic effects.

47 OTHER INSTRUMENTATION↗

Advancing Temperature Monitoring of the Bottom Anode in a Direct Current Electric Arc Furnace Operations with Distributed Optical Fiber Sensors.

The bottom anode in the Direct Current Electric Arc Furnace (DC EAF) is critical for completing the electrical circuit necessary for sustaining the arc within the furnace. For pin-type bottom anodes, monitoring of the temperature of select pins instrumented with thermocouples is performed to track bottom wear in the EAF and inform the operator when the furnace should be removed from service. Furthermore, this work presents the results from a plant trial using distributed temperature monitoring of bottom anode pins in a 165-ton DC EAF over a two-month service period utilizing two optical fiber sensing techniques: fiber Bragg grating (FBG) and Rayleigh backscattering (RBS). The early detection of temperature anomalies along the length of the anode pin through distributed sensing enhances operational safety, providing a robust alternative to traditional thermocouples.

42 ENGINEERING↗

Automated, Unmanned Detection and Quantification of Fugitive Methane Emissions

Compressor stations used to move natural gas are one of the largest sources of fugitive methane emissions in the midstream sector, accounting for approximately 50% of all fugitive emissions (Zimmerle et al., 2015). This problem is most widespread at reciprocating compressors (Subramanian et al., 2015) where faulty seals are a key contributor to methane emissions (Johnson et al., 2015). As such, there is a significant need for a robust technology that could provide an early indication of an unexpected emission. Equally important, the technology needs to be able to account for biogenic versus anthropogenic sources of methane. One means of indirectly making this determination, is to leverage optical technologies that can autonomously pinpoint the source of such leaks. This presentation discusses recent work funded by the U.S. Department of Energy (DOE) National Energy Technology Laboratory (NETL), focused on the development of an innovative remote sensing technology that can reliably and autonomously detect fugitive methane emissions in near real-time, using computer vision and deep learning. The technology called the Smart Methane Leak Detection (SLED/M) system was initially developed to monitor facilities such as compressor stations in a stationary, pan-tilt-zoom configuration. The system has recently been adapted to monitor facilities from an unmanned aerial system (UAS). The speed and maneuverability of UAS platforms are attractive to leak detection and repair program operators, but introduce several challenges. Many existing methane detection algorithms rely on mostly static backgrounds becoming unusable with motion. In addition, top-down views of fugitive methane emissions present differently in Optical Gas Imagers (OGI) compared to looking across the plume. Our work has focused on overcoming these challenges, enhancing the operators ability to detect methane emissions, and pinpoint their sources. Another recent adaptation to SLED/M is the ability to quantify methane emissions using passive sensors (OGI, thermal camera), environmental conditions, plume modeling, and deep learning. SLED/M advances the state-of-the-art for methane emission detection and quantification by focusing on three key critical criteria for effective methane emission mitigation: (1) autonomy (no need for a human to be in the loop), (2) high reliability (low false alarm rates), and (3) real-time performance. Results from this work will be presented.

03 NATURAL GAS↗

An aneroid pressure sensor for constant-level balloons

The pressure sensor for the Tropical Wind Energy conversion and Reference Level Experiment (TWERLE) is described. Key design features of the sensor are: capacitive coupling, reference at midrange, up-down counting, passive oven, storage at flight pressure and prelaunch calibration. Sensor specifications are given which are based on the production results of 440 units. Drift, as estimated from simulated life tests, is 1 mb per 6 months. The overall weight of the sensor, including thermal package, is 180 g.

Levanon, N.↗

Effects of vegetation canopy structure on remotely sensed canopy temperatures

The effects of vegetation canopy structure on thermal infrared sensor response must be understood before vegetation surface temperatures of canopies with low percent ground cover can be accurately inferred. The response of a sensor is a function of vegetation geometric structure, the vertical surface temperature distribution of the canopy components, and sensor view angle. Large deviations between the nadir sensor effective radiant temperature (ERT) and vegetation ERT for a soybean canopy were observed throughout the growing season. The nadir sensor ERT of a soybean canopy with 35 percent ground cover deviated from the vegetation ERT by as much as 11 C during the mid-day. These deviations were quantitatively explained as a function of canopy structure and soil temperature. Remote sensing techniques which determine the vegetation canopy temperature(s) from the sensor response need to be studied.

Kimes, D. S.↗

Office of Aeronautics and Space Technology preliminary requirements for space science and applications platform studies

Needs and requirements for a free flying space science and applications platform to host groupings of compatible, extended mission experiments in earth orbit are discussed. A payload model which serves to define a typical set of mission requirements in the form of a descriptive data base is presented along with experiment leval and group level data summarizations and flight schedules. The payload descriptions are grouped by technology into the following categories: communications, materials (long term effect upon), materials technology development, power, sensors, and thermal control.

Source record↗