Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Testing and Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Development of a Dynamic Lidar Uncertainty Framework

As wind turbine sizes increase and wind energy expands to more complex and remote sites, remote-sensing devices such as lidars are expected to play a key role in wind resource assessment and power performance testing. The switch to remote-sensing devices represents a paradigm shift in the way the wind industry typically obtains and interprets measurement data for wind energy. For example, the measurement techniques and sources of uncertainty for a remote-sensing device are vastly different from those associated with a cup anemometer on a meteorological tower. Current IEC standards for quantifying remote sensing device uncertainty for power performance testing consider uncertainty due to mounting, calibration, and classification of the remote sensing device, among other parameters. Values of the uncertainty are typically given as a function of the mean wind speed measured by a reference device and are generally fixed, leading to climatic uncertainty values that apply to the entire measurement campaign. However, real-world experience and a consideration of the fundamentals of the measurement process have shown that lidar performance is highly dependent on atmospheric conditions, such as wind shear, turbulence, and aerosol content. At present, these conditions are not directly incorporated into the estimated uncertainty of a lidar device. In this presentation, we describe the development of a new dynamic lidar uncertainty framework that adapts to current flow conditions and more accurately represents the actual uncertainty inherent in lidar measurements under different conditions. In this new framework, sources of uncertainty are identified for estimation of the line-of-sight wind speed and reconstruction of the three-dimensional wind field. These sources are then related to physical processes caused by the atmosphere and lidar operating conditions. The framework is applied to lidar data from a field measurement site to assess the ability of the framework to predict errors in lidar-measured wind speed. The results show how uncertainty varies over time and can be used to help select data with different levels of uncertainty for different applications, for example, low uncertainty data for power performance testing versus all data for plant performance monitoring.

17 WIND ENERGY↗

SU-E-J-35: Clinical Performance Evaluation of a Phase II Proton CT Scanner

Purpose: To develop the methodology to evaluate the clinical performance of a Phase II Proton CT scanner Methods: Range errors on the order of 3%-5% constitute a major uncertainty in current charged particle treatment planning based on Hounsfield Unit (HU)-relative stopping power (RSP) calibration curves. Within our proton CT collaboration, we previously developed and built a Phase I proton CT scanner that provided a sensitive area of 9 cm (axial) × 18 cm (in-plane). This scanner served to get initial experience with this new treatment planning tool and to incorporate lessons learned into the next generation design. A Phase II scanner was recently completed and is now undergoing initial performance testing. It will increase the proton acquisition rate and provide a larger detection area of 9 cm x 36 cm. We are now designing a comprehensive evaluation program to test the image quality, imaging dose, and range uncertainty associated with this scanner. The testing will be performed along the lines of AAPM TG 66. Results: In our discussion of the evaluation protocol we identified the following priorities. The image quality of proton CT images, in particular spatial resolution and low-density contrast discrimination, will be evaluated with the Catphan600 phantom. Initial testing showed that the Catphan uniformity phantom did not provide sufficient uniformity; it was thus replaced by a cylindrical water phantom. The imaging dose will be tested with a Catphan dose module, and compared to a typical cone beam CT dose for comparable image quality. Lastly, we developed a dedicated dosimetry range phantom based on the CIRS pediatric head phantom HN715. Conclusion: A formal evaluation of proton CT as a new tool for proton treatment planning is an important task. The availability of the new Phase II proton CT scanner will allow us to perform this task. This research is supported by the National Institute of Biomedical Imaging and Bioengineering of the NIH under award number R01EB013118. The content is solely the responsibility of the authors and does not necessarily represent the official views of the NIH.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scalability of high-performance PDE solvers

Performance tests and analyses are critical to effective high-performance computing software development and are central components in the design and implementation of computational algorithms for achieving faster simulations on existing and future computing architectures for large-scale application problems. In this article, we explore performance and space-time trade-offs for important compute-intensive kernels of large-scale numerical solvers for partial differential equations (PDEs) that govern a wide range of physical applications. We consider a sequence of PDE-motivated bake-off problems designed to establish best practices for efficient high-order simulations across a variety of codes and platforms. We measure peak performance (degrees of freedom per second) on a fixed number of nodes and identify effective code optimization strategies for each architecture. In addition to peak performance, we identify the minimum time to solution at 80% parallel efficiency. The performance analysis is based on spectral and p-type finite elements but is equally applicable to a broad spectrum of numerical PDE discretizations, including finite difference, finite volume, and h-type finite elements.

97 MATHEMATICS AND COMPUTING↗

NEAR CRITICAL POINT TESTING AND PERFORMANCE RESULTS OF A SCO2 COMPRESSOR FOR A 10MWE BRAYTON CYCLE

Development and commercial acceptance of sCO2 Brayton cycles for power generation applications are growing rapidly as they offer performance advantages over other cycles. To maximize the cycle performance, the compressors are designed to operate near the critical point of the working fluid. At the critical point the fluid properties change rapidly with variations in inlet conditions. This makes it challenging to both accurately predict the performance and guarantee the operability of the compressor, as the behavior is affected by these slight variations in inlet conditions. A full scale 1st stage main compressor for a 10MWe-Class recompression Brayton cycle was built and tested to validate performance and operability in this unique operating range. The compressor was tested in a laboratory environment with additional instrumentation, beyond what is required by PTC-10, to minimize the uncertainty in the measured performance. Complete constant speed characteristics were collected at multiple supercritical points, operating at constant inlet conditions for each speed line covering a range of compressor inlet densities from 400 to 600 kg/m3. Variations in the compressor stage efficiency and choke margin were observed, and the overall operability and stability of the compressor in response to changes in operating condition were also monitored. The compressor was shown to have excellent performance that closely matched the original design prediction. The performance at various inlet conditions showed minimal change in isentropic head coefficient at the design flow, but did show some variation in efficiency and choke margin across the map. These changes in performance were observed to be minimal, and did not affect the stable operation of the compressor. The results demonstrate that a commercial scale sCO2 compressor can operate near the critical point and achieve the high levels of performance and stability required for power generation applications.

pelton, rob↗

The PROMETRA program: plane strain tests on fresh and highly irradiated zircaloy-4, ZIRLO and M5 fuel claddings

In the framework of the PROMETRA program, clad hardening constitutive laws (stress-strain curves) have been already implemented in the SCANAIR code. These laws were derived from uniaxial hoop tensile tests performed on narrow machined ring samples. However, they do not reproduce the conditions of strain multi-axiality acting on cladding during a RIA (Reactivity-Initiated Accident) in a PWR. As a consequence, a new specimen called Plane Strain Tensile (PST) similar to the annular sample developed by Pennsylvania State University has been developed at CEA on a wider notched ring. It aims to accurately predict the cladding failure in more prototypical conditions, close to plane strain hoop tension in the middle of the gage section. This paper details the PST tests implementation and results in the framework of the PROMETRA program on fresh and irradiated claddings. The development of this test has led also to the development of a technique to measure local deformations in the gage section of the PST specimen using 2-D Digital Image Correlation (DIC). Tests performed on fresh Zircaloy-4 and on irradiated Zircaloy-4, M5 and ZIRLO specimens are analyzed relying of post-test examinations and finite element simulations. In the case of tests performed on irradiated Zry-4 and ZIRLO at 280 and 350 Celsius degrees, the presence of a hydride rim favors the crack nucleation on the outer surface. In this case, rupture nucleation occurs preferentially in the vicinity of notches. Such tests are not representative of the rupture of a cladding subjected to plane strain loading. Nevertheless, they give a good representation of the initiation of rupture observed during RIA on irradiated cladding, resulting in a hydride damage. Zry-4 specimens tested at 480 Celsius degrees and M5TM at 280 and 350 C. degrees result in a ductile fracture nucleation in the center of the specimen. This rupture is prototypical of a ductile rupture of an irradiated specimen subjected to a plane strain loading. However, the nucleation on inner surface by shear at the mandrel contact is not prototypical of a clad rupture during the PCMI (Pellet Clad Mechanical Interaction) phase of a RIA (membrane stresses in the clad thickness in RIA). An important lesson learned from this experimental approach is that the PST test is a particularly complex test, both in its implementation and interpretation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Improved Creep-­Fatigue Models on Advanced Materials for SFR Applications (Final Report)

This report provides an update on the materials performance criteria and methodology relevant to sodium-cooled fast reactors (SFRs). The report is the second deliverable (Level 2) in FY11 (M2A11AN040303) under the work package A-11AN040303 “Materials Performance Criteria and Methodology” as part of the Advanced Structural Materials Program for the Advanced Reactor Concepts. The overall objective of the Materials Performance Criteria and Methodology work project is to evaluate the key requirements for the ASME Code qualification and the Nuclear Regulatory Commission (NRC) approval of advanced structural materials in support of the design and performance of sodium-cooled fast reactors. Advanced materials are a critical element in the development of fast reactor technologies. Enhanced materials performance not only improves safety margins and provides design flexibility, but also is essential for the economics of future advanced fast reactors. Qualification and licensing of advanced materials are prominent needs for the development and implementation of advanced fast reactor technologies. Nuclear structural component designs in the U.S. comply with the ASME Boiler and Pressure Vessel (B&PV) Code Section III (Rules for Construction of Nuclear Facility Components), and the NRC grants licensing. As the SFRs will operate at higher temperatures than the current light water reactors (LWRs), the design of elevated-temperature components must comply with ASME Section III Subsection NH (Class 1 Components in Elevated Temperature Service). A number of technical issues relevant to materials performance criteria and high temperature design methodology in the SFR were identified and presented in earlier reports. A viable approach to resolve these issues and the R&D priority were also recommended. The development of mechanistically based creep-fatigue interaction models for life prediction and reliable data extrapolation was chosen to be the central focus in near-term efforts. Our current focus is on the creep-fatigue damage issue in high-strength ferritic/martensitic steels such as mod.9Cr-1Mo (G91) and NF616 (G92) steels. The current ASME creep-fatigue design rule puts severe limits of fatigue and creep loads for G91 steel, the lead structural material for fast reactors. High-strength ferritic/martensitic steels behave fundamentally differently from austenitic stainless steels, for which the current ASME creep-fatigue design rules were developed. The unique deformation and damage characteristics in G91 steel, e.g. cyclic softening, degradation of creep and rupture strength during cyclic service, demands a new creep-fatigue design procedure that explicitly accounts for the material’s unique creep-fatigue behavior. G92 steel, a variant of G91 steel, is the lead candidate in the Advanced Alloy Development program. There is currently no creep-fatigue design rule available for this advanced alloy. To support the predictive model development and resolve the over-conservative issue with the ASME design rule for G91 steel, we recovered stress relaxation data from thirteen creep-fatigue tests conducted in the late 1980s and early 1990s at Oak Ridge National Laboratory, and conducted extensive data analysis in FY10. Based on this database and available literature data, we have developed a Cyclic Softening Model and a Stress Relaxation Model specifically applied to G91 steel. The Cyclic Softening Model describes the cyclic stress variation as a function of cycle number during creep-fatigue loading, and well captures the cyclic softening effect in G91 steel. The Stress Relaxation Model predicts the stress relaxation curve during the hold time of cyclic loading, and its dependence on the cyclic softening effect of G91 steel. Two creep-fatigue test systems have been set up to conduct model-oriented creep-fatigue experiments. Results from three creep-fatigue experiments on Heat 30176 of G91 steel are presented in the report: (1) a test performed at 550°C with total strain amplitude of 0.25% and a hold time of 60 s applied at peak strains in both tension and compression, (2) a test performed at 400°C with total strain amplitude of 0.5% and a tension and compression hold time of 60 s, and (3) a test performed at 20°C with total strain amplitude of 0.5% and a tension and compression hold time of 60 s. Three different test temperatures were chosen for two primary reasons: to determine the transition temperature of creep-fatigue interaction from a plasticity-dominated process to a creep-dominated process; to develop unified creep-fatigue models applicable for a wide range of temperatures. With the detailed information obtained in the creep-fatigue experiments, we have further refined the Cyclic Softening Model and Stress Relaxation Model. The Cyclic Softening Model and Stress Relaxation Model were incorporated into the Bilinear Creep-Fatigue Damage Model, forming a powerful framework for the life prediction by an improved creep-fatigue evaluation methodology. The cyclic softening and consecutive stress relaxation responses in G91 steel can be considered for each cycle of the entire cyclic process in the model calculation. The creep-fatigue damage in G91 steel was evaluated using the improved Bilinear Creep-Fatigue Damage Model without any safety margins. It was found that due to the significant cyclic softening in G91 steel, the unit creep damage in each cycle decreased continuously with increasing number of cycles. This continuous change in creep damage with cycling has significant implication in the evaluation of the total creep-fatigue damage. The total creep damage can be one order of magnitude lower when the unit creep damage at half-life was used in the evaluation in comparison with the calculations using the unit creep damage at cycle 10. An important conclusion was that the accurate assessment of the creep-fatigue damage in G91 steel must consider the history of cycling. This analysis provides a more realistic assessment of creep-fatigue damage and identifies critical factors that must be considered in the development of future advanced models for high-strength ferritic/martensitic alloys. An accelerated creep-fatigue testing methodology is proposed for the design of model-oriented experiments to guide and validate model developments. Future work will focus on creep-fatigue experiments of both G91 and G92 steels, and development of creep-fatigue models applicable to advanced ferritic/martensitic alloys. The Cyclic Softening Model and Stress Relaxation Model will be improved by incorporating microstructural parameters of dislocation density, subgrain structure, and second-phase particles. Collaborative modeling of combined Cyclic Softening Model, Stress Relaxation Model, and Interactive Damage Rate Model will be pursued for life prediction under creep-fatigue loading with extended hold time. Accelerated, well-controlled creep-fatigue tests will be conducted to provide high-quality experimental data to refine key material parameters and validate models.

Li, Meimei↗

Fenestration System Performance Research, Testing, and Evaluation

The US DOE was and is instrumental to NFRC's beginning and its continued success. The 2005 to 2009 funding enables NFRC to continue expanding and create new, improved ratings procedures. Research funded by the US DOE enables increased fenestration energy rating accuracy. International harmonization efforts supported by the US DOE allow the US to be the global leader in fenestration energy ratings. Many other governments are working with the NFRC to share its experience and knowledge toward development of their own national fenestration rating process similar to the NFRC's. The broad and diverse membership composition of NFRC allows anyone with a fenestration interest to come forward with an idea or improvement to the entire fenestration community for consideration. The NFRC looks forward to the next several years of growth while remaining the nation's resource for fair, accurate, and credible fenestration product energy ratings. NFRC continues to improve its rating system by considering new research, methodologies, and expanding to include new fenestration products. Currently, NFRC is working towards attachment energy ratings. Attachments are blinds, shades, awnings, and overhangs. Attachments may enable a building to achieve significant energy savings. An NFRC rating will enable fair competition, a basis for code references, and a new ENERGY STAR product category. NFRC also is developing rating methods to consider non specular glazing such as fritted glass. Commercial applications frequently use fritted glazing, but no rating method exists. NFRC is testing new software that may enable this new rating and contribute further to energy conservation. Around the world, many nations are seeking new energy conservation methods and NFRC is poised to harmonize its rating system assisting these nations to better manage and conserve energy in buildings by using NFRC rated and labeled fenestration products. As this report has shown, much more work needs to be done to continues research to improve existing ratings and develop new ones. NFRC needs to continue the work it has begun in several nations to implement the NFRC rating system that has been introduced. Many nations are eager to accept the expertise NFRC can offer to achieve energy conservation goals. NFRC looks forward to a continues partnership with the US Department of Energy to cooperatively achieve both.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2007 Nissan Altima-2351 Hybrid Electric Vehicle Battery Test Results

The U.S. Department of Energy's (DOE) Advanced Vehicle Testing Activity (AVTA) conducts several different types of tests on hybrid electric vehicles (HEVs), including testing the HEV batteries when both the vehicles and batteries are new, and at the conclusion of 160,000 miles of on-road accelerated testing. This report documents the battery testing performed and the battery testing results for the 2007 Nissan Altima HEV, number 2351 (VIN 1N4CL21E87C172351). The battery testing was performed by the Electric Transportation Engineering Corporation (eTec). The Idaho National Laboratory and eTec conduct the AVTA for DOE’s Vehicle Technologies Program.

33 ADVANCED PROPULSION SYSTEMS↗

25 Mg NMR and Computational Modeling Studies of the Solvation Structures and Molecular Dynamics in Magnesium Based Liquid Electrolytes

There is increasing evidence that the solvation structure of the active components in a liquid electrolyte solution strongly impacts the performance in electrochemical applications. In this work, the nanoscale solvation structures and dynamics of Mg(BH 4 ) 2 and Mg(TFSI) 2 dissolved in diglyme (DGM) at various concentrations and ratios of Mg(BH 4 ) 2 /Mg(TFSI) 2 were investigated using a combination of natural abundance 25 Mg NMR, quantum chemistry calculations of 25 Mg NMR chemical shifts, classical molecular dynamics (MD) calculations, and electrochemical performance tests. By mixing two competing Mg salts, we were able to reduce the strong covalent interactions between Mg 2+ and BH 4 – anions. A small increase is observed in the coordination number of Mg-TFSI and a significant increase in the interaction of Mg 2+ ions with glymes. Through a combination of NMR, DFT and MD simulations, various stable species around 1 nm in size were detected in the mixed salt solution, which play key roles in the enhanced electrochemical performance of the mixed electrolyte. It is established that for the neat Mg(TFSI) 2 in DGM electrolyte at dilute concentrations the TFSI - is fully dissociated from Mg 2+ . At higher concentrations, Mg 2+ and TFSI - are only partially dissociated as contact ion pairs are formed. In contrast, at 0.01 M Mg(BH 4 ) 2 (saturated concentration) in DGM, the first solvation shell of a Mg 2+ ion contains two BH 4 - anions and one DGM molecule, while the second solvation shell consists of five to six DGM molecules. An exchange mechanism between the solvation structures in the combined electrolyte containing both Mg(BH 4 ) 2 and Mg(TFSI) 2 in DGM was found to result in the observation of a single 25 Mg NMR peak. This exchange is responsible for an increase in uncoordinated anions, as well as improved stability and ionic conductivity as compared to single anion solution. Solvent molecule rearrangement and direct Mg-ion exchange between the basic solvation structures are hypothesized as likely reasons for the exchange. We elucidate that the solvent rearrangement is energetically much more favorable than direct Mg-ion hopping and is thus suggested as the dominant exchange mechanism.

Magnesium battery, electrolytes, Mg(BH4)2, Mg(TFSI↗

Outdoor Test Bed Performance of a Power Line Sensor Using a Real-Time Event Simulator

This report summarizes the design and application of an outdoor power line sensor testbed (OPLST) with a real-time simulator and power meter to compare a potential transformer (PT) and current transformer (CT) versus an advanced line-post sensor. The OPLST was created to validate advanced medium-voltage (20/34.5 kV) outdoor power line sensors used in electrical distribution systems. Electrical utilities have installed metering and relay-protection transformers like PTs and CTs for several decades. The PTs/CTs are iron core measurement transformers based on the electromagnetic induction principle and provide reliable data in normal grid operation. However, new outdoor power line sensors (OPLS) using other technologies like voltage divider, Rogowski coil and optical principles have become available and may have favorable performance and costs compared to PTs/CTs. Therefore, the importance of testing these technologies with the PT/CT, to compare the measured phase voltage/current at different power grid scenarios is crucial to understand the performance of these new OPLS. For this study a G&W Electric Model CVS-36-O power line sensor was chosen as the OPLS to test with voltage/current signals. An OPAL-RT Technologies Model OP4510 real-time simulator and Schweitzer Engineering Laboratories Model SEL-735 power meter were installed with the 20/34.5 kV OPLST to compare the measured transient events collected from an advanced OPLS and the PT/CT. This system is installed at the Distributed Energy Communications and Control (DECC) lab, Oak Ridge National Laboratory (ORNL). The simulator generated different power grid scenarios (electrical faults, capacitor bank operation, service restoration, etc.), and its analog-output signals were connected to the voltage/current amplifiers that feed the 20/34.5 kV aerial cable loop through the PT/CT devices. Additional PT/CT devices were also wired with the medium voltage aerial cable loop to measure the phase current/voltage signals and server as references. After each test, common format for transient data exchange (COMTRADE) files were collected from the SEL-735 power meter and used to compare the performance of the OPLS with the PT/CT. The behavior of analog signals, harmonic components, total harmonic distortion and crest factors were assessed and found favorable for the G&W sensor as compared to the reference PT/CT.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Impact of Refrigerant Charge, Air Flow and Expansion Devices on the Measured Performance of an Air-Source Heat Pump Part I

This paper describes extensive tests performed on a 3-ton R-22 split heat pump in heating mode. The tests contain 150 steady-state performance tests, 18 cyclic tests and 18 defrost tests. During the testing work, the refrigerant charge level was varied from 70 % to 130% relative to the nominal value; the outdoor temperature was altered by three levels at 17 F (-8.3 C), 35 F (1.7 C) and 47 F (8.3 C); indoor air flow rates ranged from 60% to 150% of the rated air flow rate; and the expansion device was switched from a fixed-orifice to a thermal expansion value. Detailed performance data from the extensive steady state cyclic and defrost testing performed were presented and compared.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Long-term stability of the Leksell Gamma Knife{sup ®} Perfexion™ patient positioning system (PPS)

Purpose: To assess the long-term mechanical stability and accuracy of the patient positioning system (PPS) of the Leksell Gamma Knife{sup ®} Perfexion™ (LGK PFX). Methods: The mechanical stability of the PPS of the LGK PFX was evaluated using measurements obtained between September 2007 and June 2011. Three methods were employed to measure the deviation of the coincidence of the radiological focus point (RFP) and the PPS calibration center point (CCP). In the first method, the onsite diode test tool with single diode detector was used together with the 4 mm collimator on a daily basis. In the second method, a service diode test tool with three diode detectors was used biannually at the time of the routine preventive maintenance. The test performed with the service diode test tool measured the deviations for all three collimators 4, 8, and 16 mm and also for three different positions of the PPS. The third method employed the conventional film pin-prick method. This test was performed annually for the 4 mm collimator at the time of the routine annual QA. To estimate the effect of the patient weight on the performance of the PPS, the focus precision tests were also conducted with varying weights on the PPS using a set of lead bricks. Results: The average deviations measured from the 641 daily focus precision tests were 0.1 ± 0.1, 0.0 ± 0.0, and 0.0 ± 0.0 mm, respectively, for the 4 mm collimator in the X (left/right of the patient), Y (anterior/posterior of the patient), and Z (superior/inferior of the patient) directions. The average of the total radial deviations as measured during ten semiannual measurements with the service diode test tool were 0.070 ± 0.029, 0.060 ± 0.022, and 0.103 ± 0.028 mm, respectively for the central, long, and short diodes for the 4 mm collimator. Similarly, the average total radial deviations measured during the semiannual measurements for the 4, 8, and 16 mm collimators and using the central diode were 0.070 ± 0.029, 0.097 ± 0.025, 0.159 ± 0.028 mm, respectively. The average values of the deviations as obtained from the five annual film pin-prick tests for the 4 mm collimator were 0.10 ± 0.06, 0.06 ± 0.09, and 0.03 ± 0.03 mm for the X, Y, Z stereotactic directions, respectively. Only a minor change was observed in the total radial deviations of the PPS as a function of the simulated patient weight up to 202 kg on the PPS. Conclusions: Excellent long-term mechanical stability and high accuracy was observed for the PPS of the LGK PFX. No PPS recalibration or any adjustment in the PPS was needed during the monitored period of time. Similarly, the weight on the PPS did not cause any significant disturbance in the performance of the PPS for up to 202 kg simulated patient weight.

61 RADIATION PROTECTION AND DOSIMETRY↗

Statistical Performance Analysis on Approximately 320 Perovskite Single- and Two-Junction Solar Cells and Modules from >30 Global Sources

As perovskite photovoltaics (PV) advance from the laboratory to commercial prototypes, their accurate and reliable performance testing is becoming increasingly important. The well documented dynamic response of perovskite solar cells to an external applied voltage has led to the development of steady-state performance measurement methods; however, these methods have not been widely adopted by the perovskite PV community. A key reason for this is that steady-state measurement methods take tens of minutes to complete, as opposed to conventional "fast" current-voltage (I-V) measurements usually lasting a few seconds. Fast I-Vs arise from a snapshot, almost always not a steady-state condition of the device; however, given their widespread use, the question arises: how do performance parameters of perovskite PV compare when measured with fast I-V and with a steady-state method? We compile results from ca. 320 perovskite PV cells and modules, including single junction, and two-terminal perovskite-perovskite and perovskite-Si tandems, and show that fast I-Vs can provide a useful measure of the open-circuit voltage of the devices, while the short-circuit current and the overall efficiency can be widely misestimated. We discuss implications of these findings on performance testing protocols and propose possible options for fast and accurate testing of perovskite PV.

asymptotic↗

An automatic input/output test experience of FPGA-based logic controller with I/O stimulator - 282

This paper describes an automatic testing approach instead of a traditional manual test for an FPGA-based Logic Controller (FLC). It mainly describes an automatic testing of FLC using an I/O stimulator with the initiated manual action. The FLC was developed by Doosan Heavy Industry and KAERI in S. Korea. We also developed a test-bed like I/O stimulator for a burning test based on the operational scenario. Signal sources from the I/O stimulator contain an analog input, an analog output, a digital input and a digital output, a programmable power supply, an RS232C serial interface, and a dual port Ethernet interface. LabVIEW Programming was used for the automatic testing. The FLC consists of a general processor module (FPM-01), a complex processor module (FPM-02), analog input modules (FAI-01), analog output modules (FAO-01), digital input modules (FDI-01), digital output modules (FDO-01), a data link module (FDL-01), and a network module (FNW-01). Among these, in this paper, automatic digital I/O testing and automatic analog I/O testing are described. In addition, for the accuracy of the automatic testing, two graphic recorders are used. One is the output results of general processor based testing, and the other is the output results of complex processor based testing. These are different company products. Redundancy recording was found in the test results. The test results were synchronized internally with the existing I/O stimulator and externally with two graphic recorders. Calibrations of all of the equipment were made before the system testing. Before the testing started, a test plan and the test procedure were set up in advance, and we performed test scenario-based automatic functional testing for the FLC as the qualification process. It can be several executed depending on the scenario and conditional parameters of the test. For validation of the accuracy and reliability in our automated test, manual testing was also performed. Manual tests were conducted in two ways. The first one was a manual test using Fluke 754 and Fluke 715. The other one was using embedded manual features of the I/O stimulator. By performing the automatic input and output testing using the I/O stimulator, the time and expense of FLC testing can be reduced significantly compared with a conventional manual test. We rechecked the automatic test results using Fluke754 manually. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantifying Stove Emissions Related to Different Use Patterns for the Silver mini (Small Turkish) Space Heating Stove

Air pollution levels in Ulaanbaatar, Mongolia’s capital, are among the highest in the world. A primary source of this pollution is emissions from traditional coal - burning space heating stoves used in the Ger (tent) regions around Ulaanbaatar. Significant investment has been made to replace traditional heating stoves with improved low - emission high-efficiency stoves. Testing performed to support selection of replacement stoves or for optimizing performance may not be representative of true field performance of the improved stoves. Field observations and lab measurements indicate that performance is impacted , often adversely, by how stoves are actually being used in the field. The objective of this project is to identify factors that influence stove emissions under typical field operating conditions and to quantify the impact of these factors. A highly - instrumented stove testing facility was constructed to allow for rapid and precise adjustment of factors influencing stove performance. Tests were performed using one of the improved stove models currently available in Ulaanbaatar. Complete burn cycles were conducted with Nailakh coal from the Ulaanbaatar region using various startup parameters, refueling conditions , and fuel characteristics . Measurements were collected simultaneously from undiluted chimney gas, diluted gas drawn directly from the chimney and plume gas collected from a dilution tunnel above the chimney. CO, CO 2 , O 2 , temperature, pressure, and particulate matter (PM) were measured . We found that both refueling events and coal characteristics strongly influenced PM emissions and stove performance. Start-up and refueling events lead to increased PM emissions with more than 98% of PM mass emitted during the 20% of the burn where coal ignition occurs. CO emissions are distributed more evenly over the burn cycle, peaking both during ignition and late in the burn cycle . We anticipate these results being useful for quantifying public health outcomes related to the distribution of improved stoves and to identify opportunities for improving and sustaining performance of the new stoves .

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Geomechanical Testing of Bayou Choctaw 102B Core for SPR Analysis

A laboratory testing program was developed to examine the short-term mechanical and time-dependent (creep) behavior of salt from the Bayou Choctaw Salt Dome. This report documents the test methodologies, and constitutive properties inferred from tests performed. These are used to extend our understanding of the mechanical behavior of the Bayou Choctaw domal salt and provide a data set for numerical analyses. The resulting information will be used to support numerical analyses of the current state of the Bayou Choctaw Dome as it relates to its crude oil storage function as part of the US Strategic Petroleum Reserve. Core obtained from Drill Hole BC-102B was tested under creep and quasi-static constant mean stress axisymmetric compression, and constant mean stress axisymmetric extension conditions. Creep tests were performed at 100 degrees Fahrenheit, and the axisymmetric tests were performed at ambient temperatures (72-78 degrees Fahrenheit). The testing performed indicates that the dilation criterion is pressure and stress state dependent. It was found that as the mean stress increases, the shear stress required to cause dilation increases. The results for this salt are reasonably consistent with those observed for other domal salts. Also it was observed that tests performed under extensile conditions required consistently lower shear stress to cause dilation for the same mean stress, which is consistent with other domal salts. Young's moduli ranged from 3.95 x 10 6 to 8.51 x 10 6 psi with an average of 6.44 x 10 6 psi, with Poisson's ratios ranging from 0.10 to 0.43 with an average of 0.30. Creep testing indicates that the BC salt is intermediate in creep resistance when compared with other bedded and domal salt steady-state behavior.

58 GEOSCIENCES↗

Preliminary Analysis of the General Performance and Mechanical Behavior of Irradiated FeCrAl Base Alloys and Weldments

The iron-based, iron-chromium-aluminum (FeCrAl) alloys are promising, robust materials for deployment in current and future nuclear power plants. This class of alloys demonstrates excellent performance in a range of environments and conditions, including high-temperature steam (>1000°C). Furthermore, these alloys have the potential to have prolonged survival under loss-of-coolant accident (LOCA) conditions compared to the more traditional cladding materials that are either Zr-based alloys or austenitic steels. However, one of the issues associated with FeCrAl alloys is cracking during welding. The present project investigates the possibility of mitigating welding-induced cracking via alloying and precise structure control of the weldments; in the frame work of the project, several advanced alloys were developed and are being investigated prior to and after neutron irradiation to provide insight into the radiation tolerance and mechanical performance of the weldments. The present report provides preliminary results on the post-irradiation characterization and mechanical tests performed during United States Fiscal Year (FY) 2016. Chapter 1 provides a general introduction, and Chapter 2 describes the alloy compositions, welding procedure, specimen geometry and manufacturing parameters. Also, a brief discussion of the irradiation at the High Flux Isotope Reactor (HFIR) is provided. Chapter 3 is devoted to the analysis of mechanical tests performed at the hot cell facility; tensile curves and mechanical properties are discussed in detail focusing on the irradiation temperature. Limited fractography results are also presented and analyzed. The discussion highlights the limitations of the testing within a hot cell. Chapter 4 underlines the advantages of in-situ testing and discusses the preliminary results obtained with newly developed miniature specimens. Specimens were moved to the Low Activation Materials Development and Analysis (LAMDA) laboratory and prepared for mechanical tests. Tensile tests were conducted at LAMDA using a modern digital image correlation approach allowing for strain distribution analysis. Plastic strain initiation and necking are discussed in detail; a concept of strain rate maps is also introduced and discussed. Follow-on SEM-EBSD and FIBTEM analysis is planned.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Assessment of the 3430 Building Filtered Exhaust Stack Sampling Probe Location

Pacific Northwest National Laboratory performed a demonstration to determine the acceptable location in which to place an air sampling probe for emissions monitoring for radionuclides in the exhaust air discharge from the new 3430 Building Filtered Exhaust Stack. The method was to adopt the results of a previously performed test series for a system of similar configuration, followed by a partial test on the actual system to verify the applicability of previously performed tests. The qualification criteria included 1) a uniform air velocity, 2) an average flow angle that does not deviate from the axis of the duct by more than 20°, 3) a uniform concentration of tracer gases, and 4) a uniform concentration of tracer particles. Section 1 provides background information for the demonstration, and Section 2 describes the test strategy, including the criteria for the applicability of model results and the test matrix. Section 3 describes the flow -angle test and the velocity uniformity test, Section 4 provides the test results, and Section 5 provides the conclusions. Appendix A includes the test data sheets, and Appendix B gives applicable qualification results from the previously tested model stack. The data from the previously tested and similarly designed stack was demonstrated to be applicable to the current design for the 3430 Building Filtered Exhaust Stack. The 3430 stack was tested in both January and May of 2010 to document the results of several changes that were made to the exhaust system after the January tests. The 3430 stack meets the qualification criteria given in the American National Standards Institute/Health Physics Society N13.1 standard. Changes to the system configuration or operations outside of the bounds of this report (e.g., exhaust velocity increases, relocation of sample probe) will require retesting/reevaluation to determine compliancewith the requirements.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗