Liquid propulsion systems
Bladder and expulsion devices for spacecraft liquid propulsion systems - pinhole leak test fixture, heat sterilization of ethylene propylene with hydrazine, and metal diaphragms
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Bladder and expulsion devices for spacecraft liquid propulsion systems - pinhole leak test fixture, heat sterilization of ethylene propylene with hydrazine, and metal diaphragms
Shaft misalignment effect on accuracy of precision digital shaft angle encoders, using test fixture and optical methods
A silver-ion bactericidal monitor is considered for the Space Shuttle Potable Water System. Potentiometric measurement using an ion-selective electrode is concluded to be the most feasible of available techniques. Four commercially available electrodes and a specially designed, solid-state, silver-sulfide electrode were evaluated for their response characteristics and suitability for space use. The configuration of the solid-state electrode with its Nernstian response of 10 to 10,000 ppb silver shows promise for use in space. A pressurized double-junction reference electrode with a quartz-fiber junction and a replaceable bellows electrolyte reservoir was designed verification-tested, and paired with a solid-state silver-sulfide electrode in a test fixture.
A closed pore ceramic foam insulation material (CPI) has been developed that offers possibilities for use as a reusable external heat shield for the NASA manned space shuttle. The outstanding characteristics of CPI are: (1) negligible water absorption due to a noninterconnecting network of cells; (2) high emittance at room and elevated temperature; (3) ability to survive at least 10 simulated reentry cycles to 1500 K using radiant heat lamps to simulate the reentry heat fluxes; (4) ability to survive, with no change in properties or appearance, at least 10 simulated plasma arc jet cycles to 1500 K (with the exception of some stress cracks induced either by the unduly severe nature of the initial arc splash heating pulse or by improper mechanical holding of the specimen in the test fixture); (5) strength (flexure); and (6) a low thermal conductivity throughout the temperature range of interest for the space shuttle.
Spring clip retainer may prove more convenient than clamps or wingnut and stud combination when holding two small parts together in test fixtures and other applications where parts must be frequently moved or changed.
A variable conductance heat pipe (VCHP) with feedback control was fabricated with a reservoir-condenser volume ratio of 10 and an axially grooved action section. Tests of the heat transport capability were greater than or equal to the analytical predictions for the no gas case. When gas was added, the pipe performance degraded by 18% at zero tilt as was expected. The placement of the reservoir heater and the test fixture cooling fins are believed to have caused a superheated vapor condition in the reservoir. Erroneously high reservoir temperature indications resulted from this condition. The observed temperature gradients in the reservoir lend support to this theory. The net result was higher than predicted reservoir temperatures. Also, significant increases in minimum heat load resulted for controller set point temperatures higher than 0 C. At 30 C, control within the tolerance band was maintained, but high reservoir heater power was required. Analyses showed that control is not possible for reasonably low reservoir heater power. This is supported by the observation of a significant reservoir heat leak through the condenser.
Documents are presented outlining the conditions and requirements of the test program. The Appendixes are as follows: appendix A -- Electron Simulation Radiation Test Specification for Voyager Electronic Parts and Devices, appendix B -- Electronic Piece-Part Testing Program for Voyager, appendix C -- Test Procedure for Radiation Screening of Voyager Piece Parts, appendix D -- Boeing In Situ Test Fixture, and appendix E -- Irradiate - Anneal (IRAN) Screening Documents.
High efficiency solar cells required for the low cost modules was developed. The production tooling for the manufacture of the cells and modules was designed. The tooling consisted of: (1) back contact soldering machine; (2) vacuum pickup; (3) antireflective coating tooling; and (4) test fixture.
A graphite epoxy shear panel with bonded on J stiffeners was investigated. The panel, loaded to buckling in a picture frame shear test is described. Two finite element models, each of which included the doubler material bonded to the panel skin under the stiffeners and at the panel edges, were used to make a stress analysis of the panel. The shear load distributions in the panel from two commonly used boundary conditions, applied shear load and applied displacement, were compared with the results from one of the finite element models that included the picture frame test fixture.
An experimental study is described in which a quartz tube, hollow cathode was operated in a test fixture allowing the simultaneous measurement of internal cathode pressure, insert temperature profiles, and the emission currents from various cathode components as a function of discharge current and propellant (mercury) mass flow rate for a number of different cathode orifice diameters. Results show that the insert temperature profile is essentially independent of orifice diameter but depends strongly on internal cathode pressure and emission current. The product of internal cathode pressure and insert diameter is shown to be important in determining the emission location and the minimum keeper voltage.
Brittle lacquer unveils effects normally visible only by ultrasonic inspection. Laquer coating measures spread of cracking and delamination in graphite/epoxy panels subjected to cyclic compression loads after impact damage. Test specimen is coated with lacquer on side opposite surface at which projectile will be fired. Spalled area shows effect of impact without removing specimen from test fixture.
The ullage compression ignition sensitivity of NOS-365 monopropellant under the pressure condition expected to be found in a medium caliber regenerative liquid propellant gun is evaluated. The results from the rapidly loaded propellant tests performed to date are presented. For this case, the physical state of the propellant is characterized by the presence of turbulence and a finely distributed ullage field. A description of the test fixtures, procedures and results is given. It is argued that the results to date indicate that with relatively simple precautionary measures NOS-365 can be rendered sufficiently immune to the ullage compression ignition mechanism to permit it to be safely used in a regenerative liquid propellant gun.
The development of an electrostatic membrane antenna for large space structure applications is discussed. Problems encountered in fabricating 4.88 m (16 foot) diameter thin film membranes are addressed. The development of a test fixture for evaluating the membranes and the comparison of surface measurement systems are also discussed.
Chain of plates embedded in flexible seal enables it to withstand side loading of 2,300 psi (116MPa) while sealing gap of up to 0.5 inch (13 mm) between cylindrical chamber wall and test fixture. Pressure-actuated seal along inner edge forces seal into contact even though cylinder wall becomes eccentric as cylinder pressure increases. Seal has many industrial applications, particularly where heat or pressure causes distortion of chamber being sealed.
Finite element models were used to study the effects of notch angle variations on the stress state within an Iosipescu shear test speciment. These analytical results were also studied to determine the feasibility of using strain gage rosettes and a modified extensometer to measure shear strains in this test specimen. Analytical results indicate that notch angle variations produced only small differences in simulated shear properties. Both strain gage rosettes and the modified extensometer were shown to be feasible shear strain transducers for the test method. The Iosipoescu shear test fixture was redesigned to incorporate several improvements. These improvements include accommodation of a 50 percent larger specimen for easier measurement of shear train, a clamping mechanism to relax strict tolerances on specimen width, and a self contained alignment tool for use during specimen installation. A set of in-plane and interlaminar shear properties were measured for three graphite fabric/epoxy composites of T300/934 composite material. The three weave patterns were Oxford, 5-harness satin, and 8-harness satin.
A hot-film constant-temperature anemometer (CTA) system was flight-tested and evaluated as a candidate sensor for determining boundary-layer transition on high-performance aircraft. The hot-film gage withstood an extreme flow environment characterized by shock waves and high dynamic pressures, although sensitivity to the local total temperature with the CTA indicated the need for some form of temperature compensation. A temperature-compensation scheme was developed and two CTAs were modified and flight-tested on the F-104/Flight Test Fixture (FTF) facility at a variety of Mach numbers and altitudes, ranging from 0.4 to 1.8 and 5,000 to 40,000 ft respectively.
An experimental and analytical study was conducted of the postbuckling response and failure characteristics of 8-, 16-, and 24-ply unstiffened graphite/epoxy plates under shear loading, including orthotropic, quasi-orthotropic, entirely +, -45 deg ply, and (0/90)s-class plates. Postbuckling stiffness is noted to be influenced by the stacking sequence and by the inplane boundary condition imposed on the test section by a picture frame test fixture. The ratio of failure load to buckling load was higher for specimens that had higher width-to-thickness ratios. It is noted that high displacement gradients may induce transverse shear stresses, and that delamination was the failure mechanism for many of the 8-ply specimens. An adhesive failure between the composite specimen and metal edge reinforcements initiated failure of the 16- and 24-ply specimens.
Significant improvements in engine readiness with reductions in maintenance costs and turn-around times can be achieved with an engine condition monitoring systems (CMS). The CMS provides health status of critical engine components, without disassembly, through monitoring with advanced sensors. Engine failure reports over 35 years were categorized into 20 different modes of failure. Rotor bearings and turbine blades were determined to be the most critical in limiting turbopump life. Measurement technologies were matched to each of the failure modes identified. Three were selected to monitor the rotor bearings and turbine blades: the isotope wear detector and fiberoptic deflectometer (bearings), and the fiberoptic pyrometer (blades). Signal processing algorithms were evaluated for their ability to provide useful health data to maintenance personnel. Design modifications to the Space Shuttle Main Engine (SSME) high pressure turbopumps were developed to incorporate the sensors. Laboratory test fixtures have been designed for monitoring the rotor bearings and turbine blades in simulated turbopump operating conditions.