Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Test Data Report”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

A novel framework for increasing research transparency: Exploring the connection between diversity and innovation

A split sample/dual method research protocol is demonstrated to increase transparency while reducing the probability of false discovery. We apply the protocol to examine whether diversity in ownership teams increases or decreases the likelihood of a firm reporting a novel innovation using data from the 2018 United States Census Bureau’s Annual Business Survey. Transparency is increased in three ways: 1) all specification testing and identifying potentially productive models is done in an exploratory subsample that 2) preserves the validity of hypothesis test statistics fromde novoestimation in the holdout confirmatory sample with 3) all findings publicly documented in an earlier registered report and in this journal publication. Bayesian estimation procedures that leverage information from the exploratory stage included in the confirmatory stage estimation replace traditional frequentist null hypothesis significance testing. In addition to increasing statistical power by using information from the full sample, Bayesian methods directly estimate a probability distribution for the magnitude of an effect, allowing much richer inference. Estimated magnitudes of diversity along academic discipline, race, ethnicity, and foreign-born status dimensions are positively associated with innovation. A maximally diverse ownership team on these dimensions would be roughly six times more likely to report new-to-market innovation than a homophilic team.

Science & Technology - Other Topics↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Summary Report)

This summary report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. A companion full report (DOE 2023) provides additional information and discussion of the tested products, test methods, and results. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products had low-pressure mercury (LPM) sources. • One GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product had LED sources. • Five GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five had LPM sources. Product testing covered radiometric and electrical performance for all 13 products as well as photobiological safety evaluation if product documentation included testable claims. Measurement results enable comparison between products and against manufacturer or vendor claims. Testing identified numerous issues related to the accuracy of claimed GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. When claims were testable, they often did not match test results. For example, three LED products that claimed to emit UV-C emitted only UV-A. Product claim issues were more common among consumer-oriented tower products, but all product types exhibited problems with accurate performance claims. The UV-C radiant efficiency (calculated as UV-C output power divided by electrical input power) of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. This study also identified several testing challenges and limitations. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Whereas integrating spheres are used to quickly measure total radiant flux (i.e., output power) and spectral distribution, goniometers are used to measure radiant intensity distribution (from which radiant flux can be calculated). Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. The integrating sphere accommodated just 2 of the 10 UV-C emitting products. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field reflect little to no UV. As a result, the study evaluated only 6 of 13 products in the far field. Electronic files of UV-C intensity data for the other 7 products, which would typically be imported into design software for designing GUV applications, may not be reliable for predicting irradiance at arbitrary far-field distances (IES 2022a; CIE 2020). Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. This CALiPER GUV Round 1 report demonstrates the significant education and training manufacturers and vendors still require to accurately test and report the performance of their GUV products. Further industry standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

42 ENGINEERING↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Full Report)

This report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products had low-pressure mercury (LPM) sources. • One GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product had LED sources. • Five GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five had LPM sources. Product testing covered radiometric and electrical performance for all 13 products as well as photobiological safety evaluation if product documentation included testable claims. Measurement results enable comparison between products and against manufacturer or vendor claims. Testing identified numerous issues related to the accuracy of claimed GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. When claims were testable, they often did not match test results. For example, three LED products that claimed to emit UV-C emitted only UV-A. Product claim issues were more common among consumer-oriented tower products, but all product types exhibited problems with accurate performance claims. The UV-C radiant efficiency (calculated as UV-C output power divided by electrical input power) of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. This study also identified several testing challenges and limitations. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Whereas integrating spheres are used to quickly measure total radiant flux (i.e., output power) and spectral distribution, goniometers are used to measure radiant intensity distribution (from which radiant flux can be calculated). Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. The integrating sphere accommodated just 2 of the 10 UV-C emitting products. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field reflect little to no UV. As a result, the study evaluated only 6 of 13 products in the far field. Electronic files of UV-C intensity data for the other 7 products, which would typically be imported into design software for designing GUV applications, may not be reliable for predicting irradiance at arbitrary far-field distances (IES 2022a; CIE 2020). Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. This CALiPER GUV Round 1 report demonstrates the significant education and training manufacturers and vendors still require to accurately test and report the performance of their GUV products. Further industry standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced Drying Cycle Simulator Thermal Response to Commercial Drying Conditions

The purpose of this report is to document updates on testing of the apparatus built to simulate commercial drying procedures for spent nuclear fuel at the Nuclear Energy Work Complex at Sandia National Laboratories. Validation of the extent of water removal in a dry spent nuclear fuel storage system based on drying procedures used at nuclear power plants is needed to close existing technical gaps. Operational conditions leading to incomplete drying may have potential impacts on the fuel, cladding, and other components in the system during subsequent storage and disposal. A general lack of data suitable for model validation of commercial nuclear canister drying processes necessitates well-designed investigations of drying process efficacy and water retention that incorporate relevant physics and well-controlled boundary conditions. This report documents testing updates for the Advanced Drying Cycle Simulator (ADCS). This apparatus was built to simulate commercial drying procedures and quantify the amount of residual water remaining in a pressurized water reactor (PWR) fuel assembly after drying. The ADCS was constructed with a prototypic 17×17 PWR fuel skeleton and waterproof heater rods to simulate decay heat. These waterproof heaters are the next generation design to heater rods developed and tested at Sandia National Laboratories in FY20. This report describes preliminary testing of the ADCS through measurement and analysis of the thermal response of the system to a subset of commercial drying conditions that exclude the introduction of water, namely simulated decay heats and pressures relevant to commercial drying. This test series, referred to as a “dry” test series in this report, spans three uniform waterproof heater rod powers (representing spent fuel decay heats), four helium fill pressures, and six vacuum levels. This test series was conducted to cover the range of expected ADCS testing conditions for upcoming “wet” testing, where water will be introduced and a simulated commercial drying cycle will be performed. The dry test conditions were derived from the commercial drying conditions seen in the High Burnup Demonstration and the vacuum drying conditions chosen for a smaller scale Dashpot Drying Apparatus tested at Sandia National Laboratories in FY22. For a given uniform power and pressure/vacuum level, the ADCS was operated at constant power and pressure and allowed to reach steady state conditions. The thermal data obtained from these tests were analyzed, and the results can inform computational models built to simulate commercial drying processes by providing baseline thermal data prior to the introduction of water. Following the preliminary dry tests, a test plan for the ADCS will be developed to implement a drying procedure that begins with the introduction of water to the system and is based on measurements from the drying process used for the High Burnup Demonstration Project. While applying power to the simulated fuel rods, this procedure is expected to consist of filling the ADCS vessel with water, draining the water with applied pressure and multiple helium blowdowns, evacuating additional water with a vacuum drying sequence at successively lower pressures, and backfilling the vessel with helium. Additional investigations are expected to feature failed fuel rod simulators with engineered cladding defects and guide tubes with obstructed dashpots to challenge the drying system with multiple water retention sites. The data from these investigations is expected to inform the efficacy of commercial drying operations through the quantification of residual water in a prototypic-length dry storage canister.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Assessment of ORIGEN Reactor Library Development for Pebble-Bed Reactors Based on the PBMR-400 Benchmark

This report provides an evaluation of present SCALE capabilities for modeling depletion of pebble-bed reactor systems, using the PBMR-400 benchmark as a test case. A specific aim of this work is to understand the system characteristics required to generate production-quality reactor data libraries for rapid depletion calculations with ORIGEN. This report includes a discussion of present SCALE capabilities for modeling doubly heterogeneous fuels, prior SCALE work modeling pebble bed–type reactors, and a detailed neutronic analysis of the PBMR-400 core for both fresh and equilibrium-composition core conditions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermal Hydraulic Experimental Test Article - Report of THETA Commissioning for METL Testing

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA has been installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2 and Figure 3. Since the FY20 THETA status report, [1], further water shakedown testing was performed, some final welding modifications were performed, all system components were sanitized, dry assembled, and commissioned before installing into METL test vessel #4. The THETA submersible electromagnetic flowmeter was welded closed to hermetically seal internal components from sodium followed by a helium leak check for the final time

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Radiometric Testing of Germicidal UV Products, Round 2: Upper-Room Luminaires (CALiPER Report)

This report analyzes the independently tested performance of eight germicidal ultraviolet (GUV) upper-room luminaires marketed for use in occupied spaces and purchased between March and June 2023. Three of the luminaires used UV-emitting LEDs, and the remaining five luminaires used low-pressure mercury (LPM) lamps. Product testing covered radiometric and electrical performance for each luminaire. Initial performance was measured for all eight products, and four were additionally measured after 100 h and 500 h of operation. Measured performance was compared against manufacturer or vendor claims. Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. As with the CALiPER GUV Round 1 report, this CALiPER GUV Round 2 report demonstrates that manufacturers and vendors need significant education and training to accurately test and report the performance of their GUV products. Further development of industry consensus standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Initial Alloy 709 constitutive models for use with the ASME design by inelastic analysis and EPP+SMT design methods

This report details a preliminary inelastic constitutive model describing the behavior of Alloy 709. This model will serve two purposes: (1) integration into Nonmandatory Appendix HBB-Z of the ASME Boiler & Pressure Vessel Code Section III, Division 5 and (2) extrapolating cyclic test data to difficult to measure conditions for formulating improved creep-fatigue design methods. For both applications, the model must accurately capture the material behavior across a wide range of temperatures and a variety of test conditions, both monotonic and cyclic. For this purpose we adopt a universal model form under consideration to standardize the description of high temperature constitutive models in the ASME Code. This report briefly restates that model form and how we calibrate the model against the test data, summarizes the test database, and validates the final, trained model by comparison to the experimental tests.

36 MATERIALS SCIENCE↗

FY23 Update: Aerosol Sampling for the Canister Deposition Field Demonstration

This report describes the results of preliminary testing of aerosol monitoring equipment that will be used to continuously monitor the aerosol source term for the multi-year Canister Deposition Field Demonstration (CDFD). These data are required inputs for the development and validation of models for the deposition of dust and potentially corrosive salts on the surface of spent nuclear fuel (SNF) dry storage canisters. Surface salt loads correlate with the extent of corrosion damage on a metal surface, and potentially to the likelihood and timing of initiation of stress corrosion cracks. Aerosols will be monitored at the CDFD site using three instruments. A Dekati ® ELPI+ cascade impactor will be used for real-time monitoring of aerosol particle sizes. It will also collect dust in 14 size bins on impactor targets that can be chemically analyzed to determine the soluble salts present as a function of particle size. However, this instrument can only measure dried aerosols, with a diameter of <10 µm. The second instrument is a Topas laser particle size spectrometer, which provides real-time monitoring of aerosol particle sizes up to ~40 µm in size. It monitors both the ambient (potentially deliquesced) aerosol particle size distributions required for the dust deposition models and the distributions of the equivalent dried particles, allowing correlation with the Dekati ® data. However, it does not discriminate between inert dust particles and salt aerosols, and it does not retain samples of the different particle sizes for later analysis. The third instrument that will monitor aerosols at the CDFD site is a Clean Air Status and Trends Network (CASTNET) tower, which uses a multiple canister system to collect weekly samples for analysis to total suspended aerosol particle compositions and atmospheric gas concentrations. This status report describes work in FY23 to develop the capabilities for using these tools. In two training exercises, the cascade impactor and laser particle sizer were deployed in two different testing environments, one indoor and one outdoor. For the cascade impactor, the tests provided opportunities for the operators to familiarize themselves with impactor substrate preparation, and post-test sample removal and analysis. For the laser particle sizer, the tests were used to evaluate different instrument parameters, to determine the most appropriate settings for capturing transient events. Data and samples were collected for weeks to months for each test, and the results are presented here. In addition to the preliminary testing, contracts were developed with WSP Analytical Labs for sample preparation and analysis of the cascade impactor samples. The impactor tower from outdoor test was delivered to WSP and used to train the staff there in disassembly, sample extraction, sample analysis, and tower reassembly with new target substrates. These are tasks that WSP will be performing routinely for the CDFD project. The CASTNET system cannot be purchased or tested until an actual site has been selected for the CDFD test. Work for this FY has been restricted to preparation of contracts for purchasing the CASTNET tower, and for sample analysis, once the tower is in operation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Community-Driven Methods for Open and Reproducible Software Tools for Analyzing Datasets from Atom Probe Microscopy

Atom probe tomography, and related methods, probe the three-dimensional architecture of a material. The software tools that microscopists use, and how these tools are connected into workflows, makes a substantial contribution to the accuracy and precision of such a material characterization experiment. Typically, we adapt methods from other communities like mathematics, data science, computational geometry, artificial intelligence, or scientific computing. We also realize that improving on research data management is a challenge when it comes to align with the FAIR data stewardship principles. Faced with this global challenge, we are convinced that collaborating is useful. Here, we report the results and challenges with an inter-laboratory call for developing test cases for several types of atom probe software tools. The results support why defining detailed recipes of software workflows and sharing these recipes is necessary and rewarding: Open source tools and (meta)data exchange can help to make our day-to-day data processing tasks become more efficient, the training of new users and knowledge transfer become easier, and assist us with automated quantification of uncertainties to gain access to substantiated results.

36 MATERIALS SCIENCE↗

AGR Program TRISO Fuel Topical Report Dialog

AGR Program Overview and Current Activities Fission Product Transport Data Short-Lived Fission Product Release Fuel Performance Margin Data Oxidation Testing Data

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Advanced Material Studies for High Intensity Proton Production Targets and Windows

The titanium alloy Ti6Al4V is widely used in accelerator facilities as beam windows, which are exposed to high cycle compressive stress waves from intense pulsed proton beams. Such materials interacting with the beam are subject to various forms of radiation damage, which can adversely affect their endurance limit. However, no fatigue data is currently available for high energy proton irradiated titanium alloy. Due to limitations in proton irradiation facilities, only miniature flat samples can be used for irradiation. To address this issue, we have developed a custom-made bend fatigue tester at Fermilab specifically for testing proton irradiated titanium alloy. In this presentation, we report on the fatigue test results obtained from this custom-fatigue tester using a non-ASTM standard specimen design. We plan to validate these sparse fatigue data with ASTM standard samples using standard fatigue samples. Furthermore, we have modified another commercial bend fatigue tester to accommodate miniature samples, and discuss some inherent deficiencies of the commercial fatigue tester to test miniature samples. To overcome this issue, a new fixture design is presented, which enables satisfactory fatigue testing on miniature samples over long periods. Finally, we present an upgrade to the custom-fatigue tester, featuring this new fixture design.

43 PARTICLE ACCELERATORS↗

Advanced Material Studies for High Intensity Proton Production Targets and Windows

The titanium alloy Ti6Al4V is widely used in accelerator facilities as beam windows, which are exposed to high cycle compressive stress waves from intense pulsed proton beams. Such materials interacting with the beam are subject to various forms of radiation damage, which can adversely affect their endurance limit. However, no fatigue data is currently available for high energy proton irradiated titanium alloy. Due to limitations in proton irradiation facilities, only miniature flat samples can be used for irradiation. To address this issue, we have developed a custom-made bend fatigue tester at Fermilab specifically for testing proton irradiated titanium alloy. In this presentation, we report on the fatigue test results obtained from this custom-fatigue tester using a non-ASTM standard specimen design. We plan to validate these sparse fatigue data with ASTM standard samples using standard fatigue samples. Furthermore, we have modified another commercial bend fatigue tester to accommodate miniature samples, and discuss some inherent deficiencies of the commercial fatigue tester to test miniature samples. To overcome this issue, a new fixture design is presented, which enables satisfactory fatigue testing on miniature samples over long periods. Finally, we present an upgrade to the custom-fatigue tester, featuring this new fixture design.

43 PARTICLE ACCELERATORS↗

Autoignition of cyclohexane at low-to-intermediate temperatures: Rapid compression machine experiments and improved comprehensive chemical kinetic model

Cycloalkanes are an important class of hydrocarbons found in conventional and alternative transportation fuels. Being one of the simplest practical cycloalkanes, cyclohexane is often used as a surrogate in studies to understand the oxidation, ignition, and sooting characteristics of cycloalkanes more broadly. Although cyclohexane has been extensively studied, very limited datasets for cyclohexane oxidation at low-to-intermediate temperatures are available in the literature. Moreover, the literature autoignition data from rapid compression machines (RCMs) did not provide information on volume histories or experimental heat transfer characteristics which can significantly impact model predictions, thereby hindering the detailed validation of chemical kinetic models. It has also been observed that the cyclohexane kinetic models developed so far are not able to predict the literature data across a wide range of operating and mixture conditions. Hence, further studies are recommended to understand and improve model predictions for cyclohexane oxidation. In this study, RCM experiments were conducted using cyclohexane/air mixtures at varying compressed pressures (P C =15, 20, and 30 bar), equivalence ratios (ϕ=0.5, 1.0, and 2.0), and compressed temperatures (T C =670–960 K). The current RCM results of cyclohexane were found to complement well with the literature data, with the first-stage IDTs at high pressures and volume histories at all test conditions being first reported for better development and validation of chemical kinetic models. Additionally, a detailed chemical kinetic model for the cyclohexane oxidation has been developed and validated using both newly acquired experimental IDTs in this study and literature experimental studies (IDTs in RCMs and STs, species profiles in jet-stirred reactors, and laminar burning velocities). Unlike literature models, the proposed model was observed to provide an overall better prediction for experimental results over a wide range of conditions. Chemical kinetic analysis of the developed model was further conducted to identify the reaction pathways controlling the autoignition of cyclohexane.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Upgrading biocrude oil into sustainable aviation fuel using zeolite-supported iron-molybdenum carbide nanocatalysts

Food waste is an underdeveloped source for production of sustainable aviation fuel (SAF). Now, there is no certified conversion process of food waste for SAF by American Society for Testing and Materials (ASTM). We report the use of zeolite-supported molybdenum carbide nanocatalysts in upgrading biocrudes, produced from food wastes through HTL, into SAF precursors. Our data show a complete removal of oxygen from the biocrude through hydrodeoxygenation and a higher heating value of 46.5 MJ/kg, which is comparable to that of Jet A (46.1 MJ/kg). The prescreening tests (tier alpha and beta) show the average carbon number of the distillation cut (150° to 230°C) of upgraded fuel is 10.6, close to the value of 11.4 for average conventional jet fuel, and the specifications of properties including surface tension, viscosity, heating value, flash point, and freezing point were found to meet the standards of SAF. The metal carbide nanocatalysts were reusable in upgrading tests, and the activity of deoxygenation was retained.

10 SYNTHETIC FUELS↗

SRF Cavity Instability Detection with Machine Learning at CEBAF

During the operation of CEBAF, one or more unstable superconducting radio-frequency (SRF) cavities often cause beam loss trips while the unstable cavities themselves do not necessarily trip off. Identifying an unstable cavity out of the hundreds of cavities installed at CEBAF is difficult and time-consuming. The present RF controls for the legacy cavities report at only 1 Hz, which is too slow to detect fast transient instabilities. A fast data acquisition system for the legacy SRF cavities is being developed which samples and reports at 5 kHz to allow for detection of transients. A prototype chassis has been installed and tested in CEBAF. An autoencoder based machine learning model is being developed to identify anomalous SRF cavity behavior. The model is presently being trained on the slow (1 Hz) data that is currently available, and a separate model will be developed and trained using the fast (5 kHz) DAQ data once it becomes available. This paper will discuss the present status of the new fast data acquisition system and results of testing the prototype chassis. This paper will also detail the initial performance metrics of the autoencoder model.

Carpenter, A.↗

SRF Cavity Instability Detection with Machine Learning at CEBAF

During the operation of CEBAF, one or more unstable superconducting radio-frequency (SRF) cavities often cause beam loss trips while the unstable cavities themselves do not necessarily trip off. Identifying an unstable cavity out of the hundreds of cavities installed at CEBAF is difficult and time-consuming. The present RF controls for the legacy cavities report at only 1 Hz, which is too slow to detect fast transient instabilities. A fast data acquisition system for the legacy SRF cavities is being developed which samples and reports at 5 kHz to allow for detection of transients. A prototype chassis has been installed and tested in CEBAF. An autoencoder based machine learning model is being developed to identify anomalous SRF cavity behavior. The model is presently being trained on the slow (1 Hz) data that is currently available, and a separate model will be developed and trained using the fast (5 kHz) DAQ data once it becomes available. This paper will discuss the present status of the new fast data acquisition system and results of testing the prototype chassis. This paper will also detail the initial performance metrics of the autoencoder model.

Carpenter, A.↗

Printed Strain Gauges for High Temperature Applications (>300°C)

The real-time understanding of strain and deformation of materials provides prognostic health monitoring of components of current operational reactors and valuable data that shortens the timeline for the development of new nuclear-relevant materials in test reactor experiments. This report discusses the current development and testing of additively manufactured strain gauges. This has potential to improve the sensor design and manufacturing techniques to meet the requirements of the current and advanced nuclear reactors (i.e., in terms of environment conditions, sample geometry, and materials compatibility). The developmental additively manufactured strain gauges are exposed to separate effects testing (i.e., mechanical strain, high temperature) to determine environmental factors that affect the strain gauge. In addition, sensor qualification methodologies are further developed for determining the reliability and robustness at the interface of the AM strain gauge materials.

36 MATERIALS SCIENCE↗