Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TOMOGRAPHY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

X-ray Computed Tomography of Irradiated and Unirradiated AGR-3/4 Compacts

X-ray Computed Tomography (XCT) has been utilized to image and characterize compacts from the combined third and fourth irradiation of the Advanced Gas Reactor (AGR) Program, AGR-3/4, fuel. The experiment contained tristructural isotropic (TRISO)-coated fuel particles as well as designed-to-fail (DTF) fuel particles. Two irradiated compacts, representing the lower and higher range of AGR-3/4 burnup (4.85% and 14.92% fissions per initial heavy metal atom FIMA) were examined. These represent the first known highly irradiated TRISO fuel compacts to be examined via X-ray CT. Additionally, two unirradiated compacts from the same production batch as the examined irradiation compacts were also imaged for a baseline comparison. As XCT of irradiated TRISO compacts is not a commonly implemented characterization technique, a significant portion of the report focuses on developed methodology and imaging conditions. A specialized sample shielding device was developed and fabricated specifically to limit received dose to staff during sample preparation for XCT and to minimize excess gamma radiation dose to sensitive electronic components with the utilized X-ray system. Significant penetration through the uranium oxycarbide fuel kernels by significantly hardening the X-ray beam with specialized proprietary filters acquired from Carl Zeiss NTS Ltd. The filter utilized resulted in an average X ray photon energy of ~110 keV which approaches uranium’s K-edge (~115 keV), maximizing penetration for a microfocus X-ray source. The gamma-radiation emitted from the irradiated AGR-3/4 TRISO compacts, has the same properties and mechanisms for interaction with matter as X-rays, thus the detection of gamma-radiation by the utilized X-ray detectors was initially a concern. However, although ?-rays did produce an observable signal on the X-ray detector, its contribution to the overall imaging results appeared negligible upon 3D reconstruction. The neglibile impact on the resulting 3D reconstructed volumes were likely the result of: (1) a significantly lower detection efficiency for ?-rays relative to X-rays; (2) An X-ray flux at the detector several orders of magnitude higher than that of the impinging ?-rays from the irradiated compacts. These results suggest that irradiated compacts with significantly higher radiation fields can be examined in the future if an acceptable route for sample handling and preparation can be determined. Additionally, the 3D imaging results of XCT can provide a valuable means of assessing compacts. While in many ways complimentary to traditional post irradiation examination techniques such as optical ceramography, XCT can provide additional insight into compact features traditionally difficult to discern directly from cross-sectional imaging alone. Preliminary analyses on kernel size, morphology (aspect ratio and sphericity), and kernel orientation were presented. Sphericity, a simple morphological shape descriptor, was utilized to screen for kernel extrusions within the high burnup compact. The number of kernel extrusions identified via XCT represented an approximate two-fold increase from the quantity of extruded particles observed (via optical ceramography) in adjacent compacts from the same irradiation capsule. While numerical analysis of the compact datasets was highly preliminary, initial results show promise for providing complimentary metrics to current AGR-3/4 PIE and potentially additional insight into the processes driving TRISO fuel degradation during reactor operation. Additional analyses to be performed at a later date include a more detailed examination of kernel size, kernel sphericity (and observed kernel extrusions), and sphericity. Given all particles can be observed in a single data volume possible correlation of spatial position with observed kernel features will also be made at a later date.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ultrasonic Testing (UT) and Computed Tomography (CT) Comparative Scanning of Proposed Additive Manufacturing Reference Standard

This report presents qualitative results of ultrasonic full matrix capture/total focusing method (FMC/TFM) scanning of two series of blocks, additively manufactured by powder bed fusion, containing a variety of internal features and structures that would not be achievable by conventional manufacturing techniques. The purpose of the first series of additively manufactured (AM) blocks was to explore the possibility of building calibration blocks for FMC/TFM ultrasonic testing (UT). It was confirmed that AM is a suitable candidate for generation of unusual and novel reflector forms, such as rotating slots, purposely embedded voids, and tapering holes, and that FMC/TFM was very capable of characterizing them. The intended use of the second series of AM blocks was as UT reference blocks to characterize the AM process quality or the interrogating UT technique. The larger block in this series was scanned from multiple faces, using multiple UT methods (conventional UT and FMC/TFM) and X-ray computed tomography for comparative purposes. The performance of each method was quantified by a metric corresponding to the detection limit of each feature, and the quantitative results are discussed.

36 MATERIALS SCIENCE↗

Integrating Electrical Resistivity Tomography with Vadose Zone Characterization - 20246

The environmental management mission at the U.S. Department of Energy Hanford Site includes addressing subsurface contaminants that are present in the vadose zone because of historical waste discharges. Characterization is needed to support evaluation of whether contaminants at specific disposal sites will migrate to and contaminate the groundwater in the future. Drilling of boreholes and analysis of retrieved sediment samples is a standard approach to evaluating contaminant distribution in the vadose zone for the types of inorganic and radionuclide contaminants at the Hanford Site. However, borehole sampling has limitations for understanding the volumetric distribution of contaminants. The Hanford Site is now applying electrical resistivity tomography to characterize the path and volumetric extent of contaminant migration in the vadose zone. This information aids selection of appropriate locations for obtaining borehole samples and provides three-dimensional contaminant distribution information for incorporation into conceptual site models and to help configure fate and transport models. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impacts of Biomass Feedstock Pre-Processing on Heat and Mass Transfer During Pyrolysis Using X-Ray Computed Tomography and Multiscale Modeling

Knowledge of the transport properties of biomass particles such as porosity, tortuosity, and permeability is paramount for high-fidelity modeling of biomass pyrolysis due to the heat and mass transfer limitations imposed by particle microstructure. X-ray computed tomography (XCT) is a non-destructive imaging method that enables full 3D reconstructions of the biomass particle microstructure with high resolution, permitting direct calculation of porosity, tortuosity, and permeability from real particle geometries. In this study, XCT imaging revealed the 3D microstructures of particles and chars from pyrolytic conversion of cylindrically cut or milled/pelletized loblolly pine samples. The porosity, tortuosity, and permeability were calculated directly from the XCT geometries via open-source microstructural analysis tool MATBOX+TauFactor (https://github.com/NREL/MATBOX_Microstructure_analysis_toolbox) and computational fluid dynamics (CFD) simulations using our solver, Mesoflow (https://github.com/NREL/mesoflow). These properties were used in a reactor scale model developed in COMSOL of the single particle reactor at NREL to investigate the impact of feedstock pre-processing on biomass conversion during pyrolysis with rigorous experimental validation.

biomass↗

Enhancing Cluster Identification in Atom Probe Tomography Data Using Transfer Learning

Atom probe tomography (APT) has enabled the direct visualization of solute clusters, providing valuable insights into material structures. This clustering is crucial for understanding the nanoscale composition and behavior of materials, which can significantly influence their mechanical and physical properties. However, the widely used clustering methods in the APT community face challenges such as subjective parametric selection and limited applicability, particularly in dealing with overlapping clusters, nested clusters, and artifacts across different scales, such as precipitates and dislocations. To address these challenges, we present a framework based on density-based cluster analysis that aims to be less dependent on user input, reproducible, and robust.

Density-based clustering↗

Enhancing Cluster Identification in Atom Probe Tomography Data Using Transfer Learning

Atom Probe Tomography (APT) is a powerful technique for visualizing the atomic-scale distribution of solutes in materials, but quantitative cluster analysis of APT datasets remains a challenge due to the need for subjective parameter selection in clustering algorithms. While distance-based and density-based methods such as HDBSCAN are widely used, their performance is highly sensitive to user-defined parameters, which undermines reproducibility and accuracy. This study proposes an image-based, deep learning-aided workflow for automating parameter selection and cluster detection in APT data analysis. By projecting 3D APT point clouds onto 2D planes, we leverage pretrained convolutional neural networks (ConvNeXt-Tiny and ResNet-50) through transfer learning to predict the number of clusters present in synthetic datasets. The output is used to guide K-means clustering and estimate HDBSCAN parameters, specifically minimum cluster size and minimum sample points. This approach reduces reliance on manual parameter tuning, improving consistency and scalability. The methodology demonstrates the feasibility of using image-based deep learning for interpreting complex spatial patterns in APT data, enabling faster and more objective analysis. The complete workflow and code are made publicly available to support reproducibility and future research.

Density-based clustering↗

Advanced Interactive 3D Visualization Tool for Customizable Analyses of Tomography Datasets in Material Science

Current methods for visualizing and analyzing 3D tomography datasets in materials science often lack the interactivity and depth required for detailed structural insights. This limitation restricts a researchers' ability to accurately interpret complex data, which is critical for advancing material innovations and understanding structural properties. To address this issue, we have developed a novel, web-based interactive 3D visualization and analysis tool from the Trame framework that offers customizable features to enhance data interpretability. The tool allows users to adjust parameters such as visible range, slice planes, data rotation, and layering, providing a more detailed and dynamic view of complex structures. Its user-friendly web interface increases the accessibility and ease of use for both novice and experienced researchers, to visualize large volumetric datasets. The tool supports a diverse range of data formats, making it versatile for various research applications. Unique capabilities include real-time data manipulation, automated feature detection, context-sensitive feedback, and real-time volume calculations and distributions per sliced region or layer, alongside the ability to quickly generate high-quality screenshots and videos for presentations and reports. These advancements offer a comprehensive solution for enhanced 3D data exploration, significantly improving the analysis process and communication of results in materials science.

36 - MATERIALS SCIENCE↗

Tau Positron Emission Tomography for Predicting Dementia in Individuals With Mild Cognitive Impairment

An accurate prognosis is especially pertinent in mild cognitive impairment (MCI), when individuals experience considerable uncertainty about future progression. To evaluate the prognostic value of tau positron emission tomography (PET) to predict clinical progression from MCI to dementia. This was a multicenter cohort study with external validation and a mean (SD) follow-up of 2.0 (1.1) years. Data were collected from centers in South Korea, Sweden, the US, and Switzerland from June 2014 to January 2024. Participant data were retrospectively collected and inclusion criteria were a baseline clinical diagnosis of MCI; longitudinal clinical follow-up; a Mini-Mental State Examination (MMSE) score greater than 22; and available tau PET, amyloid-β (Aβ) PET, and magnetic resonance imaging (MRI) scan less than 1 year from diagnosis. A total of 448 eligible individuals with MCI were included (331 in the discovery cohort and 117 in the validation cohort). None of these participants were excluded over the course of the study. Exposures included Tau PET, Aβ PET, and MRI. Positive results on tau PET (temporal meta–region of interest), Aβ PET (global; expressed in the standardized metric Centiloids), and MRI (Alzheimer disease [AD] signature region) was assessed using quantitative thresholds and visual reads. Clinical progression from MCI to all-cause dementia (regardless of suspected etiology) or to AD dementia (AD as suspected etiology) served as the primary outcomes. The primary analyses were receiver operating characteristics. In the discovery cohort, the mean (SD) age was 70.9 (8.5) years, 191 (58%) were male, the mean (SD) MMSE score was 27.1 (1.9), and 110 individuals with MCI (33%) converted to dementia (71 to AD dementia). Only the model with tau PET predicted all-cause dementia (area under the receiver operating characteristic curve [AUC], 0.75; 95% CI, 0.70-0.80) better than a base model including age, sex, education, and MMSE score (AUC, 0.71; 95% CI, 0.65-0.77; P = .02), while the models assessing the other neuroimaging markers did not improve prediction. In the validation cohort, tau PET replicated in predicting all-cause dementia. Compared to the base model (AUC, 0.75; 95% CI, 0.69-0.82), prediction of AD dementia in the discovery cohort was significantly improved by including tau PET (AUC, 0.84; 95% CI, 0.79-0.89; P < .001), tau PET visual read (AUC, 0.83; 95% CI, 0.78-0.88; P = .001), and Aβ PET Centiloids (AUC, 0.83; 95% CI, 0.78-0.88; P = .03). In the validation cohort, only the tau PET and the tau PET visual reads replicated in predicting AD dementia. In this study, tau-PET showed the best performance as a stand-alone marker to predict progression to dementia among individuals with MCI. This suggests that, for prognostic purposes in MCI, a tau PET scan may be the best currently available neuroimaging marker.

59 BASIC BIOLOGICAL SCIENCES↗

Multihead Attention U‐Net for Magnetic Particle Imaging–Computed Tomography Image Segmentation

Magnetic particle imaging (MPI) is an emerging noninvasive molecular imaging modality with high sensitivity and specificity, exceptional linear quantitative ability, and potential for successful applications in clinical settings. Computed tomography (CT) is typically combined with the MPI image to obtain more anatomical information. Herein, a deep learning‐based approach for MPI‐CT image segmentation is presented. The dataset utilized in training the proposed deep learning model is obtained from a transgenic mouse model of breast cancer following administration of indocyanine green (ICG)‐conjugated superparamagnetic iron oxide nanoworms (NWs‐ICG) as the tracer. The NWs‐ICG particles progressively accumulate in tumors due to the enhanced permeability and retention (EPR) effect. The proposed deep learning model exploits the advantages of the multihead attention mechanism and the U‐Net model to perform segmentation on the MPI‐CT images, showing superb results. In addition, the model is characterized with a different number of attention heads to explore the optimal number for our custom MPI‐CT dataset.

Juhong, Aniwat↗

Harmonizing tau positron emission tomography in Alzheimer's disease: The CenTauR scale and the joint propagation model

Abstract INTRODUCTION Tau‐positron emission tomography (PET) outcome data of patients with Alzheimer's disease (AD) cannot currently be meaningfully compared or combined when different tracers are used due to differences in tracer properties, instrumentation, and methods of analysis. METHODS Using head‐to‐head data from five cohorts with tau PET radiotracers designed to target tau deposition in AD, we tested a joint propagation model (JPM) to harmonize quantification (units termed “CenTauR” [CTR]). JPM is a statistical model that simultaneously models the relationships between head‐to‐head and anchor point data. JPM was compared to a linear regression approach analogous to the one used in the amyloid PET Centiloid scale. RESULTS A strong linear relationship was observed between CTR values across brain regions. Using the JPM approach, CTR estimates were similar to, but more accurate than, those derived using the linear regression approach. DISCUSSION Preliminary findings using the JPM support the development and adoption of a universal scale for tau‐PET quantification. Highlights Tested a novel joint propagation model (JPM) to harmonize quantification of tau PET. Units of common scale are termed “CenTauRs”. Tested a Centiloid‐like linear regression approach. Using five cohorts with head‐to‐head tau PET, JPM outperformed linearregressionbased approach. Strong linear relationship was observed between CenTauRs values across brain regions.

Neurosciences & Neurology↗

Positron emission tomography harmonization in the Alzheimer's Disease Neuroimaging Initiative: A scalable and rigorous approach to multisite amyloid and tau quantification

Abstract INTRODUCTION A key goal of the Alzheimer's Disease NeuroImaging Initiative (ADNI) positron emission tomography (PET) Core is to harmonize quantification of β‐amyloid (Aβ) and tau PET image data across multiple scanners and tracers. METHODS We developed an analysis pipeline (Berkeley PET Imaging Pipeline, B‐PIP) for ADNI Aβ and tau PET images and applied it to PET data from other multisite studies. Steps include image pre‐processing, refacing, magnetic resonance imaging (MRI)/PET co‐registration, visual quality control (QC), quantification of tracer uptake, and standardization of Aβ and tau standardized uptake value ratios (SUVrs) across tracers. RESULTS Measurements from 10,105 cross‐sectional and longitudinal Aβ and tau PET scans acquired in several studies between 2010 and 2024 can be processed, harmonized, and directly merged across tracers and cohorts. DISCUSSION The B‐PIP developed in ADNI is a scalable image harmonization approach used in several observational studies and clinical trials that facilitates rigorous Aβ and tau PET quantification and data sharing. Highlights Quantitative results from ADNI Aβ and tau PET data are generated using a rigorous, scalable image processing pipeline This pipeline has been applied to PET data from several other large, multisite studies and trials Quantitative outcomes are harmonizable across studies and are shared with the scientific community

Neurosciences & Neurology↗

Cryogenic Correlative Single‐Particle Photoluminescence Spectroscopy and Electron Tomography for Investigation of Nanomaterials

Abstract Cryogenic single‐particle photoluminescence (PL) spectroscopy has been used with great success to directly observe the heterogeneous photophysical states present in a population of luminescent particles. Cryogenic electron tomography provides complementary nanometer scale structural information to PL spectroscopy, but the two techniques have not been correlated due to technical challenges. Here, we present a method for correlating single‐particle information from these two powerful microscopy modalities. We simultaneously observe PL brightness, emission spectrum, and in‐plane excitation dipole orientation of CdSSe/ZnS quantum dots suspended in vitreous ice. Stable and fluctuating emitters were observed, as well as a surprising splitting of the PL spectrum into two bands with an average energy separation of 80 meV. In some cases, the onset of the splitting corresponded to changes in the in‐plane excitation dipole orientation. These dynamics were assigned to structures of individual quantum dots and the excitation dipoles were visualized in the context of structural features.

Dahlberg, Peter D.↗

Pore-Filling Induced Solid Electrolyte Failure of Ti-Doped Na 3 Zr 2 Si 2 PO 12 Characterized by Operando Synchrotron X-Ray Tomography

Solid-state batteries (SSBs), particularly those utilizing sodium metal, are emerging as a promising technology due to their potential for enhanced safety, higher energy density, and longer cycle life. NASICON (Na superionic conductor) materials, known for their robust crystalline structure and high ionic conductivity, are pivotal in the development of efficient sodium all-solid-state batteries. These materials exhibit high room-temperature ionic conductivity and electrochemical stability, making them ideal for various applications. Research has focused on improving NASICON's ionic conductivity and stability through doping, interface regulation, and composite anode design. Recent advancements include Ti-doped Na 3 Zr 2 Si 2 PO 12 (Ti-NZSP), which demonstrates improved surface stability, higher ionic conductivity, and increased critical current density. However, challenges such as Na dendrite formation and mechanical integrity under operational conditions persist. Advanced imaging techniques like operando synchrotron X-ray tomography have provided insights into failure mechanisms, revealing that pore-filling and dendrite growth are significant issues. Understanding these processes is essential for enhancing the performance and safety of Na-based SSBs. Here, this study underscores the need for continued research to address these challenges and develop reliable, high-performance solid-state electrolytes for future energy storage solutions.

25 ENERGY STORAGE↗

Ability of x‐ray computed tomography to resolve critical flaw size in laser‐based, paste stereolithography ceramic printing of alumina

Abstract Complex alumina parts were printed using vat photopolymerization (VPP), which is a stereolithography‐based additive manufacturing (AM) technique used to shape ceramic preforms, or green parts. The critical flaw size was determined using classical fracture mechanics techniques. The strength and fracture toughness were measured and compared to flaws detected in x‐ray computed tomography (XCT or CT) distributions as well as the fracture surfaces. The strength was lower compared traditionally made alumina, and that is due to layering effects, slurry defects, and printing defects. The critical flaw size from fracture mechanics was 206 µm. XCT has high enough resolution to detect the critical flaw size and much smaller features, where the average flaw size observed in CT scans was around 80–100 µm. The fracture surfaces indicate that flaws causing failure are larger than that of the critical flaw size (∼300 µm), but fracture surfaces do not show definitive features compared to traditionally made ceramics. Since XCT can observe flaws smaller than the critical flaw size, this method can be used as a screening technique.

36 MATERIALS SCIENCE↗

Synchrotron‐source micro‐x‐ray computed tomography for examining butterfly eyes

Comparative anatomy is an important tool for investigating evolutionary relationships among species, but the lack of scalable imaging tools and stains for rapidly mapping the microscale anatomies of related species poses a major impediment to using comparative anatomy approaches for identifying evolutionary adaptations. We describe a method using synchrotron source micro-x-ray computed tomography (syn-μXCT) combined with machine learning algorithms for high-throughput imaging of Lepidoptera (i.e., butterfly and moth) eyes. Our pipeline allows for imaging at rates of ~15 min/mm 3 at 600 nm 3 resolution. Image contrast is generated using standard electron microscopy labeling approaches (e.g., osmium tetroxide) that unbiasedly labels all cellular membranes in a species-independent manner thus removing any barrier to imaging any species of interest. To demonstrate the power of the method, we analyzed the 3D morphologies of butterfly crystalline cones, a part of the visual system associated with acuity and sensitivity and found significant variation within six butterfly individuals. Despite this variation, a classic measure of optimization, the ratio of interommatidial angle to resolving power of ommatidia, largely agrees with early work on eye geometry across species. We show that this method can successfully be used to determine compound eye organization and crystalline cone morphology. Our novel pipeline provides for fast, scalable visualization and analysis of eye anatomies that can be applied to any arthropod species, enabling new questions about evolutionary adaptations of compound eyes and beyond.

59 BASIC BIOLOGICAL SCIENCES↗

Recurrent and convolutional neural networks for sequential multispectral optoacoustic tomography ( MSOT ) imaging

Abstract Multispectral optoacoustic tomography (MSOT) is a beneficial technique for diagnosing and analyzing biological samples since it provides meticulous details in anatomy and physiology. However, acquiring high through‐plane resolution volumetric MSOT is time‐consuming. Here, we propose a deep learning model based on hybrid recurrent and convolutional neural networks to generate sequential cross‐sectional images for an MSOT system. This system provides three modalities (MSOT, ultrasound, and optoacoustic imaging of a specific exogenous contrast agent) in a single scan. This study used ICG‐conjugated nanoworms particles (NWs‐ICG) as the contrast agent. Instead of acquiring seven images with a step size of 0.1 mm, we can receive two images with a step size of 0.6 mm as input for the proposed deep learning model. The deep learning model can generate five other images with a step size of 0.1 mm between these two input images meaning we can reduce acquisition time by approximately 71%.

Juhong, Aniwat↗

Physics‐based iterative reconstruction for dual‐source and flying focal spot computed tomography

Purpose For single‐source helical Computed Tomography (CT), both Filtered‐Back Projection (FBP) and statistical iterative reconstruction have been investigated. However, for dual‐source CT with flying focal spot (DS‐FFS CT), a statistical iterative reconstruction that accurately models the scanner geometry and acquisition physics remains unknown to researchers. Therefore, our purpose is to present a novel physics‐based iterative reconstruction method for DS‐FFS CT and assess its image quality. Methods Our algorithm uses precise physics models to reconstruct from the native cone‐beam geometry and interleaved dual‐source helical trajectory of a DS‐FFS CT. To do so, we construct a noise physics model to represent data acquisition noise and a prior image model to represent image noise and texture. In addition, we design forward system models to compute the locations of deflected focal spots, the dimension, and sensitivity of voxels and detector units, as well as the length of intersection between x‐rays and voxels. The forward system models further represent the coordinated movement between the dual sources by computing their x‐ray coverage gaps and overlaps at an arbitrary helical pitch. With the above models, we reconstruct images by an advanced Consensus Equilibrium (CE) numerical method to compute the maximum a posteriori estimate to a joint optimization problem that simultaneously fits all models. Results We compared our reconstruction with Siemens ADMIRE, which is the clinical standard hybrid iterative reconstruction (IR) method for DS‐FFS CT, in terms of spatial resolution, noise profile, and image artifacts through both phantoms and clinical scan datasets. Experiments show that our reconstruction has a higher spatial resolution, with a Task‐Based Modulation Transfer Function (MTF task ) consistently higher than the clinical standard hybrid IR. In addition, our reconstruction shows a reduced magnitude of image undersampling artifacts than the clinical standard. Conclusions By modeling a precise geometry and avoiding data rebinning or interpolation, our physics‐based reconstruction achieves a higher spatial resolution and fewer image artifacts with smaller magnitude than the clinical standard hybrid IR.

Wang, Xiao↗