Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TIME MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Fast data-driven spectrometer with direct measurement of time and frequency for multiple single photons

We present a single-photon-sensitive spectrometer based on a linear array of 512 single-photon avalanche diode detectors with 0.04 nm spectral and 40 ps temporal resolutions. We employ a fast data-driven operation that allows direct measurement of time and frequency for simultaneous single photons, time- and frequency-stamping each single-photon detection. Our results combine excellent temporal and spectral resolution. This work opens numerous applications in quantum photonics, especially when both spectral and temporal properties of single photons can be exploited.

79 ASTRONOMY AND ASTROPHYSICS↗

Time-resolved single-photon detection module based on silicon photomultiplier: A novel building block for time-correlated measurement systems

We present the design and preliminary characterization of the first detection module based on Silicon Photomultiplier (SiPM) tailored for single-photon timing applications. The aim of this work is to demonstrate, thanks to the design of a suitable module, the possibility to easily exploit SiPM in many applications as an interesting detector featuring large active area, similarly to photomultipliers tubes, but keeping the advantages of solid state detectors (high quantum efficiency, low cost, compactness, robustness, low bias voltage, and insensitiveness to magnetic field). The module integrates a cooled SiPM with a total photosensitive area of 1 mm{sup 2} together with the suitable avalanche signal read-out circuit, the signal conditioning, the biasing electronics, and a Peltier cooler driver for thermal stabilization. It is able to extract the single-photon timing information with resolution better than 100 ps full-width at half maximum. We verified the effective stabilization in response to external thermal perturbations, thus proving the complete insensitivity of the module to environment temperature variations, which represents a fundamental parameter to profitably use the instrument for real-field applications. We also characterized the single-photon timing resolution, the background noise due to both primary dark count generation and afterpulsing, the single-photon detection efficiency, and the instrument response function shape. The proposed module can become a reliable and cost-effective building block for time-correlated single-photon counting instruments in applications requiring high collection capability of isotropic light and detection efficiency (e.g., fluorescence decay measurements or time-domain diffuse optics systems).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Shock tube ignition delay times and methane time-histories measurements during excess CO 2 diluted oxy-methane combustion

The combustion of methane in air results in large amounts of CO 2 and NO X emissions. In order to reduce the NO X emissions, one possible solution is the oxy-methane combustion with large CO 2 dilution so that the combustion products can be reduced mainly to CO 2 and H 2 O. However, there are very few studies on the chemical kinetics of oxy-methane combustion in a CO 2 diluted environment. In this study, methane time-histories, CH* emission profiles, and pressure time-histories measurements were conducted behind reflected shock waves to gain insight into the effects of CO 2 dilution of the gas mixtures on the ignition of methane. The measurements were carried out for mixtures of CH 4 , CO 2 and O 2 in argon bath gas at temperatures of 1577–2144 K, pressures of 0.53–4.4 atm, equivalence ratios (Φ) of 0.5, 1, and 2, and CO 2 mole fractions (X CO2 ) of 0, 30, and 60%. The laser absorption measurements were conducted using a continuous wave distributed feedback interband cascade laser (DFB ICL) centered at 3403.4 nm. The results showed the decrease of activation energy and the increase of ignition delay time as the amount of CO 2 dilution was increased. However, the changes were minor and within the experimental uncertainties of the measurements. Also, the results were compared to the predictions of two different natural gas mechanisms: GRI 3.0 and AramcoMech 1.3 mechanisms. In general the predictions were reasonable when compared to the experimental data; however, there were discrepancies at some conditions. Three different influences of CO 2 addition to the argon bath gas in regards to chemistry, collision efficiencies, and heat capacities were examined. In addition, the present study included experimentally obtained correlations for absorption cross sections of methane for its P(8) line in the v3 band in argon bath gas with and without carbon-dioxide dilutions at temperatures between 1200 < T < 2000 K and pressures between 0.7 < P < 1.2 atm.

42 ENGINEERING↗

Ignition delay time and CO time-history measurements in a shock tube during high performance jet fuel surrogate combustion

The chemical kinetics of diisobutylene, a proposed biofuel, has been studied behind reflected shock waves near 10 atm over a temperature range of 1186 – 1414 K. A stoichiometric mixture consisting of 0.15% diisobutylene was used to investigate ignition behavior and speciation during oxidation experiments performed in a shock tube. Time resolved measurements of carbon monoxide were measured behind reflected shock waves with a continuous wave quantum cascade laser centered at a frequency of 2046.20 cm^-1 using a fixed-wavelength spectroscopy scheme.

09 BIOMASS FUELS↗

Time resolved measurements in a low aspect ratio transonic compressor stage

The time resolved flowfield in a low aspect ratio transonic compressor stage has been studied using a high frequency response sphere probe with a bandpass of D.C. to 20 kHz in a blowdown compressor facility. Averaged over the compressor annulus, the data agree well with those measured with standard pitot type probes on the same stage in a conventional test rig. Not all the spanwise distributions agree, however. These differences are explained as errors in the pitot probe readings due to fluctuations in the flow. The experimental data are compared to the results of a three-dimensional inviscid Euler calculation.

Epstein, A. H.↗

Time-resolved measurements of Cooper-pair radiative recombination in InAs quantum dots

We studied InAs quantum dots (QDs) where electron Cooper pairs penetrate from an adjacent niobium (Nb) superconductor with the proximity effect. With time-resolved luminescence measurements at the wavelength around 1550 nm, we observed luminescence enhancement and reduction of luminescence decay time constants at temperature below the superconducting critical temperature (T{sub C}) of Nb. On the basis of these measurements, we propose a method to determine the contribution of Cooper-pair recombination in InAs QDs. We show that the luminescence enhancement measured below T{sub C} is well explained with our theory including Cooper-pair recombination.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of time dependent CP asymmetry parameters in B0 meson decays to omegaKs, etaprimeKz, and pi0Ks

The authors present measurements of the time-dependent CP-violation parameters S and C in the decays B{sup 0} {yields} {omega}K{sub S}{sup 0}, B{sup 0} {yields} {eta}{prime}K{sup 0}, reconstructed as {eta}{prime}K{sub S}{sup 0} and {eta}{prime}K{sub L}{sup 0}, and B{sup 0} {yields} {pi}{sup 0}K{sub S}{sup 0}. The data sample corresponds to the full BABAR dataset of 467 x 10{sup 6} B{bar B} pairs produced at the PEP-II asymmetric-energy e{sup +}e{sup -} collider at the Stanford Linear Accelerator Center. The results are S{sub {omega}K{sub S}{sup 0}} = 0.55{sub -0.29}{sup +0.26} {+-} 0.02, C{sub {omega}K{sub S}{sup 0}} = -0.52{sub -0.20}{sup +0.22} {+-} 0.03, S{sub {eta}{prime}K{sup 0}} = 0.57 {+-} 0.08 {+-} 0.02, C{sub {eta}{prime}K{sup 0}} = -0.08 {+-} 0.06 {+-} 0.02, S{sub {pi}{sup 0}K{sub S}{sup 0}} = 0.55 {+-} 0.20 {+-} 0.03, and C{sub {pi}{sup 0}K{sub S}{sup 0}} = 0.13 {+-} 0.13 {+-} 0.03, where the first errors are statistical and the second systematic. These results are consistent with the previous measurements and the world average of sin2{beta} measured in B{sup 0} {yields} J/{psi}K{sub S}{sup 0}.

43 PARTICLE ACCELERATORS↗

A new large radius imaging plate camera for high-resolution and high-throughput synchrotron x-ray powder diffraction by multiexposure method

A new large radius imaging plate diffraction camera for high-resolution and high-throughput synchrotron x-ray powder diffraction by means of multiple exposures has been developed for an insertion device beamline of SPring-8, Japan. The new imaging plate camera consists of a large radius cylindrical shape imaging plate cassette that is 400 mm in length and 954.9 mm in cylinder radius. The cassette is designed to be mounted on the 2{theta} arm of the diffractometer of BL15XU in SPring-8. One imaging plate covers 24 deg. and several times of exposure changing the 2{theta}-setting angle is necessary to obtain whole powder diffraction data up to a high angle region. One pixel of the imaging plate corresponds to 0.003 deg. in 2{theta} when the readout pixel size is 50 {mu}m squares. Separately collected data are translated to 2{theta}-intensity format and are connected by comparing the peak and background intensity included in the overlapped area. The exposure time is less than 120 s for most samples and the readout time is about 3 min; thus, the total measurement time for one powder diffraction pattern is less than 20 min. The measurement time is the same order as the continuous 2{theta}-scanning method of the third generation synchrotron powder diffractometer. The angular resolution of the new imaging plate camera was evaluated by comparing the full width at half maximum of the 111 reflection of NBS-Si. The observed angular resolution is not so high as a powder diffractometer with a Si or a Ge analyzer monochromator in the third generation synchrotron facility but higher than a powder diffractometer with a Ge analyzer monochromator at a bending magnet beamline of the second generation synchrotron. The Rietveld analysis of NBS-CeO{sub 2} was successfully carried out with the data taken by the new imaging plate camera.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Space-time resolved measurements of spontaneous magnetic fields in laser-produced plasma

The first space-time resolved spontaneous magnetic field (SMF) measurements realized on Prague Asterix Laser System are presented. The SMF was generated as a result of single laser beam (1.315 μm) interaction with massive planar targets made of materials with various atomic numbers (plastic and Cu). Measured SMF confirmed azimuthal geometry and their maximum amplitude reached the value of 10 MG at the laser energy of 250 J for both target materials. It was demonstrated that spatial distributions of these fields are associated with the character of the ablative plasma expansion which clearly depends on the target material. To measure the SMF, the Faraday effect was employed causing rotation of the vector of polarization of the linearly polarized diagnostic beam. The rotation angle was determined together with the phase shift using a novel design of a two-channel polaro-interferometer. To obtain sufficiently high temporal resolution, the polaro-interferometer was irradiated by Ti:Sa laser pulse with the wavelength of 808 nm and the pulse duration of 40 fs. The results of measurements were compared with theoretical analysis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time-resolved measurements of double layer evolution in expanding plasma

Observations in steady-state plasmas confirm predictions that formation of a current-free double layer in a plasma expanding into a chamber of larger diameter is accompanied by an increase in ionization upstream of the double layer. The upstream plasma density increases sharply at the same driving frequency at which a double layer appears. For driving frequencies at which no double layer appears, large electrostatic instabilities are observed. Time-resolved measurements in pulsed discharges indicate that the double layer initially forms for all driving frequencies. However, for particularly strong double layers, instabilities appear early in the discharge and the double layer collapses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gamma bang time analysis at OMEGA

Absolute bang time measurements with the gas Cherenkov detector (GCD) and gamma reaction history (GRH) diagnostic have been performed to high precision at the OMEGA laser facility at the University of Rochester with bang time values for the two diagnostics agreeing to within 5 ps on average. X-ray timing measurements of laser-target coupling were used to calibrate a facility-generated laser timing fiducial with rms spreads in the measured coupling times of 9 ps for both GCD and GRH. Increased fusion yields at the National Ignition Facility (NIF) will allow for improved measurement precision with the GRH easily exceeding NIF system design requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Second Harmonic Generation Guided Raman Spectroscopy for Sensitive Detection of Polymorph Transitions

Second harmonic generation (SHG) was integrated with Raman spectroscopy for the analysis of pharmaceutical materials. Particulate formulations of clopidogrel bisulfate were prepared in two crystal forms (Form I and Form II). Image analysis approaches enable automated identification of particles by bright field imaging, followed by classification by SHG. Quantitative SHG microscopy enabled discrimination of crystal form on a per particle basis with 99.95% confidence in a total measurement time of ~10 ms per particle. Complementary measurements by Raman and synchrotron XRD are in excellent agreement with the classifications made by SHG, with measurement times of ~1 min and several seconds per particle, respectively. In conclusion, coupling these capabilities with at-line monitoring may enable real-time feedback for reaction monitoring during pharmaceutical production to favor the more bioavailable but metastable Form I with limits of detection in the ppm regime.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A diagnostic to measure time-resolved atom column density and Doppler temperature in atomic vapors produced by laser ablation

We report on the development of a diagnostic to measure the time-resolved column density and Doppler temperature of atomic vapors produced by laser ablation. The diagnostic is based on the strong frequency dependence of the atomic susceptibility near an electronic transition in the interrogated atomic species. Interference on the face of a fast photodetector between the several frequency components present in a sinusoidally phase-modulated probe beam will produce a time signature uniquely determined by the column density of atoms in the probed atomic state and the Doppler temperature of the atomic vapor. With the extensive, high precision atomic spectroscopy data available in the literature, it is possible to model the vapor and extract the desired parameters through comparison of the model result with the experimental data.

47 OTHER INSTRUMENTATION↗

Time-resolved measurement of electron beam neutralization

An intense relativistic electron beam (IREB) incident on a target generates positive ions by stimulated and thermal desorption of adsorbed gas, and subsequent electron impact ionization. These ions are accelerated upstream by the beam space-charge potential, thereby partially neutralizing the beam. If there is enough neutralization, the repulsive space-charge force can be overcome by the magnetic-pinch force due to the beam current. This so-called ion focusing is responsible for time dependent defocusing of the radiographic source spot. Since a single monolayer of adsorbed gas has a surface density of about 10 15 /cm 2 and is formed in about one second in a one micro-Torr vacuum, there is always enough adsorbed gas to make this a concern in our accelerators. Therefore, time-resolved measurements of the degree of neutralization are valuable for better understanding of this process with an eye to mitigation for improvement of our radiography. Moreover, these measurements would aid quantification of uncertainties due to these effects when using invasive beam diagnostics, such as OTR imaging targets.

43 PARTICLE ACCELERATORS↗

Acoustic Tomography of the Atmosphere: A Large-Eddy Simulation Sensitivity Study

Accurate measurement of atmospheric turbulent fluctuations is critical for understanding environmental dynamics and improving models in applications such as wind energy. Advanced remote sensing technologies are essential for capturing instantaneous velocity and temperature fluctuations. Acoustic tomography (AT) offers a promising approach that utilizes sound travel times between an array of transducers to reconstruct turbulence fields. This study presents a systematic evaluation of the time-dependent stochastic inversion (TDSI) algorithm for AT using synthetic travel-time measurements derived from large-eddy simulation (LES) fields under both neutral and convective atmospheric boundary-layer conditions. Unlike prior work that relied on field observations or idealized fields, the LES framework provides a ground-truth atmospheric state, enabling quantitative assessment of TDSI retrieval reliability, sensitivity to travel-time measurement noise, and dependence on covariance model parameters and temporal data integration. A detailed sensitivity analysis was conducted to determine the best-fit model parameters, identify the tolerance thresholds for parameter mismatch, and establish a maximum spatial resolution. The TDSI algorithm successfully reconstructed large-scale velocity and temperature fluctuations with root mean square errors ( RMSE s) below 0.35 m/s and 0.12 K, respectively. Spectral analysis established a maximum spatial resolution of approximately 1.4 m, and reconstructions remained robust for travel-time measurement uncertainties up to 0.002 s. These findings provide critical insights into the operational limits of TDSI and inform future applications of AT for atmospheric turbulence characterization and system design.

17 WIND ENERGY↗

Colliding Laser Pulses for Laser-Plasma Accelerator Injection Control

Decoupling injection from acceleration is a key challenge to achieve compact, reliable, tunable laser-plasma accelerators (LPA). In colliding pulse injection the beat between multiple laser pulses can be used to control energy, energy spread, and emittance of the electron beam by injecting electrons in momentum and phase into the accelerating phase of the wake trailing the driver laser pulse. At LBNL, using automated control of spatiotemporal overlap of laser pulses, two-pulse experiments showed stable operation and reproducibility over hours of operation. Arrival time of the colliding beam was scanned, and the measured timing window and density of optimal operation agree with simulations. The accelerator length was mapped by scanning the collision point.

43 PARTICLE ACCELERATORS↗

Ion-temperature determination with a baffled Langmuir probe

An electrostatic Langmuir probe for real-time measurements of parameters in magnetized plasma is tested in fully ionized, barium, Q-machine plasma. The small-diameter, long-length, tungsten wire sensor, i.e., the probe tip, oriented with its cylindrical axis perpendicular to the magnetic field (B), is partially shielded by ceramic baffles, or masks, that form sensor-access slots between the baffles. Adjusting the azimuthal orientation of the slots, by rotating the probe about its cylindrical axis, changes the fraction of proximity gyro-orbiting electrons, relative to the fraction of proximity gyro-orbiting ions, that can access the recessed sensor along the magnetic field. Thus, the ratio between the electron and ion saturation currents, $I^{sat}_e$ and $I^{sat}_i$, can be adjusted without having affected the probe bias voltage V b . When optimally shielded ($I^{sat}_e/I^{sat}_i$=1), accurate, real-time measurements of space potential Vs can be acquired. When maximally shielded ($I^{sat}_e/I^{sat}_i$ << 1), accurate, real-time measurements of ion temperature T i can be acquired. Subtracting the floating potential V f of an optimally shielded baffled probe from V f of a maximally shielded baffled probe yields T i (and its fluctuation phase) in real time.

47 OTHER INSTRUMENTATION↗

Artifacts in digital coincidence timing

Digital methods are becoming increasingly popular for measuring time differences, and are the de facto standard in PET cameras. These methods usually include a master system clock and a (digital) arrival time estimate for each detector that is obtained by comparing the detector output signal to some reference portion of this clock (such as the rising edge). Time differences between detector signals are then obtained by subtracting the digitized estimates from a detector pair. A number of different methods can be used to generate the digitized arrival time of the detector output, such as sending a discriminator output into a time to digital converter (TDC) or digitizing the waveform and applying a more sophisticated algorithm to extract a timing estimator.All measurement methods are subject to error, and one generally wants to minimize these errors and so optimize the timing resolution. A common method for optimizing timing methods is to measure the coincidence timing resolution between two timing signals whose time difference should be constant (such as detecting gammas from positron annihilation) and selecting the method that minimizes the width of the distribution (i.e. the timing resolution). Unfortunately, a common form of error (a nonlinear transfer function) leads to artifacts that artificially narrow this resolution, which can lead to erroneous selection of the 'optimal' method. In conclusion, the purpose of this note is to demonstrate the origin of this artifact and suggest that caution should be used when optimizing time digitization systems solely on timing resolution minimization.

97 MATHEMATICS AND COMPUTING↗