Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “THALLIUM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Scintillator Efficiency Study with MeV X-Rays

We have investigated scintillator efficiency for MeV radiographic imaging. This paper discusses the modeled detection efficiency and measured brightness of a number of scintillator materials. An optical imaging camera records images of scintillator emission excited by a pulsed x-ray machine. The efficiency of various thicknesses of monolithic LYSO:Ce (cerium-doped lutetium yttrium orthosilicate) are being studied to understand brightness and resolution trade-offs compared with a range of micro-columnar CsI:Tl (thallium-doped cesium iodide) scintillator screens. The micro-columnar scintillator structure apparently provides an optical gain mechanism that results in brighter signals from thinner samples. The trade-offs for brightness versus resolution in monolithic scintillators is straightforward. For higher-energy x-rays, thicker materials generally produce brighter signal due to x-ray absorption and the optical emission properties of the material. However, as scintillator thickness is increased, detector blur begins to dominate imaging system resolution due to the volume image generated in the scintillator thickness and the depth of field of the imaging system. We employ a telecentric optical relay lens to image the scintillator onto a recording CCD camera. The telecentric lens helps provide sharp focus through thicker-volume emitting scintillators. Stray light from scintillator emission can also affect the image scene contrast. We have applied an optical light scatter model to the imaging system to minimize scatter sources and maximize scene contrasts.

scintillator, radiography, CCD camera, hard x-ray,↗

Antimony-based anode on aluminum current collector

An electrochemical battery is provided with an aluminum anode current collector and an antimony (Sb)-based electrochemically active material overlying the aluminum current collector. The Sb-based electrochemically active material may be pure antimony, Sb with other metal elements, or Sb with non-metal elements. For example, the Sb-based electrochemically active material may be one of the following: Sb binary or ternary alloys of sodium, silicon, tin, germanium, bismuth, selenium, tellurium, thallium, aluminum, gold, cadmium, mercury, cesium, gallium, titanium, lead, carbon, and combinations thereof. The aluminum current collector may additionally include a material such as magnesium, iron, nickel, titanium, and combinations thereof. In one aspect, the anode further composed of a coating interposed between the aluminum current collector and the Sb-based electrochemically active material. This coating may be a non-corrodible metal or a carbonaceous material. The cathode is may be composed of a number of different active materials including sodium-based Prussian Blue analogs.

25 ENERGY STORAGE↗

The Beam Dump eXperiment

Hadronic matter makes about 14% of the known universe. The remaining 86% is Dark Matter (DM). Since it does not interact with the ordinary matter via electromagnetic force, DM is not visible and, to date, it escaped detection. The search for Dark Matter (DM) is one of the hottest topic in modern physics. Despite the increasing number of astrophysical and cosmological observations proving the existence, so far no particle physics experiment has detected DM yet. Up to now, most of the experimental efforts have been focused on the so called WIMP (Weakly Interacting Massive Particle) paradigm, which predicts heavy DM (10 GeV-10 TeV mass range) interacting with Standard Model (SM) particles via the weak force mediators (W or Z bosons). More recently, due to the lack of clear evidence of WIMPs, other models of DM gained the interest of the physics community. These models consider Light DM particles (LDM), in MeV-GeV mass range. Among LDM theories, the Dark Photon theory predicts the existence of a Dark Sector interacting with SM particles via a new massive vector boson (Dark Photon, Heavy Photon or A0), mediator of a new force. This scenario, despite being theoretically well motivated, is remarkably experimentally unexplored. The Beam Dump eXperiment (BDX), is an approved experiment at Jefferson Lab (JLab), aiming to discover the DM predicted witihn the Dark Photon theory. The experiment uses the CEBAF (Continuous Electron Beam Accelerator Facility) 11 GeV electron beam, impinging on the JLab Hall-A beam-dump, to produce a beam of DM particles, detected by a ~ 1 m3 detector made of thallium doped cesium iodide (CsI(Tl)) crystals located ~ 20 m downstream. In order to achieve excellent background rejection, the experimental setup includes active vetos and passive shielding surrounding CsI(Tl) crystals. Given the weakness of the DM-SM interaction, the scattering of a DM particle in the BDX detector is a rare event. Therefore, the characterization of the expected background is a critical aspect of the experiment. Both cosmogenic and penetrating SM particles produced by the beam interaction in the dump contribute to the background of the experiment. While the cosmogenic contribution can be measured during the experiment when the beam is off, beam-related background can only be estimated via Monte Carlo (MC) simulations. Therefore, a careful assessment of possible systematics introduced by the MC is needed. The beam-correlated background characterization was made by measuring the muon flux produced by the interaction of the CEBAF beam with Hall-A dump in a dedicated experimental campaign in spring 2018 [1]. The comparison to the ?ux predicted by MC allowed us to validate the BDX simulation framework. The reach of BDX, i.e. the region that the experiment can probe in the LDM theory parameter space, depends critically on the background rejection capability and signal detection effciency. For this reason, the detector setup was fine-tuned through a dedicated study. The response to LDM and background events was evaluated for different setups and selection cuts. As a result of this procedure, the configuration resulting in the best sensitivity was selected [2]. The reach calculation was performed taking into account the different LDM production mechanisms, including the contribution of secondary particles produced in the beam-dump. In particular, the effect of the secondary positrons annihilation was found to be extremely significant. In the majority of the sensitivity studies, this contribution is neglected, but recent results [3] [4] demonstrated that this process significantly enhances the sensitivity of lepton beam-dump experiments. Currently, the BDX collaboration is focused on the deployment and operation of a small detector, called BDX-MINI, built to perform a preliminary physics measurement searching for LDM at JLab. This test will pave the way to the realization of the full BDX experiment. The measurement is currently ongoing but results are expected by the end of this year. During my PhD I was involved in all aspects of the BDX experiment: design, simulation, prototyping and data analysis. The main results of my work are reported in this thesis. This manuscript is organized as follows: the first Chapter provides an introduction to the theory of LDM, with particular attention to the Dark Photon paradigm; the second Chapter illustrates the BDX experimental setup, the LDM production and detection mechanisms and the expected backgrounds; Chapter 3 and 4 describe, respectively, the BDX-HODO measurement, with a detailed description of the simulations, and the BDX experimental setup and analysis cuts optimization. Chapter 5 reports about BDXMINI detector characterization, calibration and sensitivity estimate. Finally, Chapter 6 describes in detail the calculation of the secondary positron annihilation contribution to the sensitivity of BDX and other electron-beam thick-target experiment.

Marsicano, Luca↗

AMS / BARC Joint Survey Addendum Technical Report

This report details the data analysis results from data collected during the September-October 2019 joint survey series between the Department of Energy (DOE) National Nuclear Security Administration (NNSA) Aerial Measuring System (AMS) asset, and the Government of India’s Department of Atomic Energy (DAE) Bhabha Atomic Research Centre (BARC). This joint survey series took place at the Nevada National Security Site (NNSS), areas of public land in Southern Nevada, and at the DOE Office of Legacy Management (LM) Large Area Calibration Pads (LACP) at the Grand Junction Regional Airport in Grand Junction, CO. The data detailed in this report were gathered at the LACP. More details regarding the setup of these surveys and personnel involvement can be found in the AMS / BARC Joint Survey Summary Report. The data from the LACP collected by AMS are consistent with past data collection campaigns at the LACP. The AMS Bell 412 (B412) helicopter, equipped with both the standard AMS thallium-doped sodium iodide (NaI(Tl)) 2"x4"x16" 12-detector system and a subset of the BARC Aerial Gamma Spectroscopy System (AGSS) consisting of two independent 3"x3"cylindrical NaI(Tl) detectors, measured each of the five calibration pads for a minimum of 10 minutes. After the helicopter measurements, a pressurized ion chamber (PIC) was used to directly measure radiation exposure rates on each of the pads for a period 5 minutes. The geophysical calibration procedure published by the International Atomic Energy Agency (IAEA) (Erdi-Krausz et al. 2003) was used to determine the spectral stripping sensitivity matrix for naturally occurring radiological material (NORM). The sensitivity matrix is consistent with the AMS long term average. Additionally, the PIC data was used to calibrate the AMS system for exposure rate. The results of the exposure rate analysis are also consistent with AMS long-term averages.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quantity of 135I Released from the AGR 5/6/7 Experiment

A series of four Advanced Reactor Technologies (ART) experiments have been conducted in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL). From 2006 through 2020, these experiments supported the development and qualification of the new U.S. tristructural isotropic (TRISO) particle fuel for Very High Temperature Reactors (VHTR). Each Advanced Gas Reactor (AGR) experiment consisted of multiple fueled capsules, each plumbed for independent temperature control using a mix of helium and neon gases. The gas leaving a capsule was routed to individual Fission Product Monitor (FPM) detectors. For intact fuel particles, the TRISO particle coatings provide a substantial barrier to fission product release. However, particles with failed coatings, whether because of a minute percentage of initially defective particles, those which fail during irradiation, or those designed to fail (DTF) particles, can release fission products to the flowing gas stream. Because reactive fission product elements like iodine and cesium quickly deposit on cooler capsule components and piping structures as the effluent gas leaves the reactor core, only the noble fission gas isotopes of Kr and Xe tend to reach FPM detectors. The FPM system utilizes High Purity Germanium (HPGe) detectors coupled with a thallium activated sodium iodide NaI(Tl) scintillator. The HPGe detector provides individual isotopic information, while the NaI(Tl) scintillator is used as a gross count rate meter. During irradiation, the 135mXe concentration reaching the FPM detectors is from both direct fission and by decay of the accumulated 135I. About 2.5 hours after irradiation (ten 15.3 minute 135mXe half lives) the directly produced 135mXe has decayed and only the longer lived 135I remains as a source. Decay systematics dictate that 135mXe will be in secular equilibrium with its 135I parent, such that its production rate very nearly equals the decay rate of the parent, and its concentration in the flowing gas stream will appear to decay with the parent half life. This equilibrium condition enables the determination of the amount of 135I released from the fuel particles by measurement of the 135mXe at the FPM following reactor shutdown. In this paper, the 135I released will be reported.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Tl+-based and mixed halide A3B2X9-type scintillators

Inorganic halides (e.g., inorganic halide scintillators) of the general formula A3B2X9, including inorganic halides comprising thallium monovalent cations and/or combinations of different halides, are described. Radiation detectors including the inorganic halide scintillators and methods of using the detectors to detect high energy radiation are also described. In some cases, the scintillators can include a gadolinium cation, a boron cation, a lithium cation, a chloride ion, or combinations thereof and the scintillator can be used to detect neutrons.

Rutstrom, Daniel↗

A Case Study Correlating Innovative Gamma Ray Scanning Detection Systems Data to Surface Soil Gamma Spectrometry Results - 13580

HydroGeoLogic (HGL), Inc. completed a United States Environmental Protection Agency (USEPA) study to characterize radiological contamination at a site near Canoga Park, California. The characterized area contained 470 acres including the site of a prototype commercial nuclear reactor and other nuclear design, testing, and support operations from the 1950's until 1988 [1]. The site history included radiological releases during operation followed by D and D activities. The characterization was conducted under an accelerated schedule and the results will support the project remediation. The project has a rigorous cleanup to background agenda and does not allow for comparison to risk-based guidelines. To target soil sample locations, multiple lines of evidence were evaluated including a gamma radiation survey, geophysical surveys, historical site assessment, aerial photographs, and former worker interviews. Due to the time since production and decay, the primary gamma emitting radionuclide remaining is cesium-137 (Cs-137). The gamma ray survey covered diverse, rugged terrain using custom designed sodium iodide thallium-activated (NaI(Tl)) scintillation detection systems. The survey goals included attaining 100% ground surface coverage and detecting gamma radiation as sensitively as possible. The effectiveness of innovative gamma ray detection systems was tested by correlating field Cs-137 static count ratios to Cs-137 laboratory gamma spectrometry results. As a case study, the area encompassing the former location of the first nuclear power station in the U. S. was scanned, and second by second global positioning system (GPS)-linked gamma spectral data were evaluated by examining total count rate and nuclide-specific regions of interest. To compensate for Compton scattering from higher energy naturally occurring radionuclides (U-238, Th-232 and their progeny, and K-40), count rate ratios of anthropogenic nuclide-specific regions of interest to the total count rate were calculated. From the scanning data, locations with observed Cs-137 ratios exceeding six standard deviations above the mean ratio were mapped in high resolution [2]. Field teams returned to those locations to collect static count measurements using the same detection systems. Soil surface samples were collected at 30 locations and analyzed for Cs-137. An exponential correlation was identified between Cs-137 concentrations in surface soil and field-scanned Cs-137 ratios. The data indicate field minimum detectable concentration (MDC) of Cs-137 at 0.02 Bq/g (0.5 pCi/g) or lower depending on contaminant distribution in soil. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Developing High-Energy Laser-Driven Bremsstrahlung Radiation Sources for Imaging and Analysis of Nuclear Waste Packages - 17300

Radiographic imaging of small scale simulated nuclear waste packages (a 28 mm uranium penny encapsulated in grout) was achieved using a single pulse exposure from an x-ray source driven by a high-power laser. The high-energy laser pulse was generated at the Vulcan laser facility, which focused the photon burst onto a tantalum target foil in order to produce a bright burst of highly penetrating x-rays (with energy >500 keV) from a source size less than 0.5 mm. The sample was imaged using BAS-TR and BAS-SR image plates alongside a Thallium doped Caesium Iodide scintillator-based detector coupled to CCD chips for rapid image acquisition. The penny was resolved to sub-mm accuracy over a 30 cm{sup 2} scan area from a single shot. In addition, on a parallel beamline, neutron generation (of 10{sup 7}-10{sup 9} neutrons per steradian per pulse) was achieved, thereby demonstrating the potential application for criticality testing of waste packages. The principle concern regarding intermediate level waste (ILW) containers is the internal volumetric expansion due to the formation of corrosion products. Therefore, simulated waste samples with hydride corrosion have been formed and characterised in order to emulate this phenomenon. In addition, samples containing controlled isotopic ratios have been formed. This next generation of simulated waste samples have been produced in preparation for a second phase of analysis at the Vulcan laser facility to quantify the identification ability of radiographic imaging and characterisation accuracy of neutronics measurements. This feasibility study successfully demonstrated non-destructive radiography of encapsulated, high density, nuclear material and this paper details the next phase of technological development. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of Computed Tomography Techniques for Material Identification in Low Level and Intermediate Level Waste - 16648

Measures required to assure long term safe storage of Low-level and intermediate-level short-lived (LIL/SL) waste generated by the nuclear-power industry in France include the characterization of the waste and identification of materials within the waste. Digital Radiography (DR) techniques using x-ray at energies in the 6 MeV range have been shown to be effective for validation of the integrity of the concrete containers, and it was considered that the use of this technique together with the addition of Computed Tomography (CT) techniques could effectively identify materials within the waste. This paper describes the initial evaluation of two DR imaging techniques and two CT techniques using x-ray energy spectra up to 9 MeV to inspect a surrogate waste package, which comprised an outer concrete cylindrical container of 1400 mm diameter with 148 mm wall thickness, and an overall volume of 2 meters cubed, within which a 200 liter drum containing representative heterogeneous inactive waste, was placed in the center and the annulus between the 200 liter drum and the outer cylindrical package was filled with cement grout. The surrogate waste within the 200 liter drum comprised three separate layers of high density, medium density and low density mixed materials. The equipment used was a linear accelerator producing high energy spectra at either 6 MeV or 9 MeV and a high-precision CT manipulator with X, Y, Z and rotation motions, which were common to all techniques investigated. Two different digital detectors were used in the DR and CT performance evaluations, a Digital Detector Array (DDA) comprising a columnar Thallium-doped Cesium-Iodide scintillator screen in intimate contact with a 2 k by 2 k array of amorphous silicon detectors, 200 μm x 200 μm in area, and a Linear Diode Array (LDA) comprising a line of Cadmium-Tungstate columns, 1 cm thick and 400 μm x 400 μm in area. The work comprised evaluations of linear accelerator spectra and the attenuation effects of the waste container and contents, image acquisition performance of each detector, and CT techniques using area detector and linear detector. The results presented in this paper include mathematical evaluation of the two CT techniques, and analysis of measurement data, digital images, CT reconstruction images, and estimated material densities. The data was compared with recorded details and photographs of the actual configuration of materials within the surrogate waste. The Digital Detector Array can generate CT inspection volumes with considerable resolution and detail for the low-density and medium-density sections of the surrogate waste, however, the high-density sections were not imaged with sufficient detail and the images contained a large number of artifacts mainly due to the detectors lack of high energy photon stopping power. Materials identification with the Digital Detector Array, while possible for certain materials, for materials in the steel to plastic density range the attenuation values of the voxels in the reconstruction are too similar and difficult to resolve from the artifacts present. The Linear Diode Array can generate CT inspection volumes of regions of interest of the low-density and medium-density sections with considerable resolution and contrast, and potentially acceptable levels of resolution and contrast of the high-density section of the waste. While a few artifacts were present in the reconstructions, the majority are not due to the fundamental properties of the detector and are considered to be correctable. Materials identification with the LDA inspection data appear to be viable, with steel, copper, and higher-density metals being readily be distinguished from other materials on the basis of voxel value. Future work is needed to obtain a better definition of optimum spatial resolution and inspection speed, and to develop a system of 'calibration rods' which would consist of a series of 50 mm diameter cylinders of 7 materials; Plastic, Teflon, Concrete, Aluminum, Copper, Tungsten and Lead. The cylinders will be distributed at a certain radius in the surrogate waste and will be used as reference points in the evaluation and demonstration of the contrastive performance for the low, medium and high-density cases. The ability to identify the materials within a sealed waste container, by nondestructive examination, enables the verification of waste acceptance criteria without the need to open the waste containers. This eliminates the need for complex and expensive equipment to open and remotely handle the intermediate level waste, avoids potential hazards and risk of personnel dose uptake, and does not increase the volume of waste caused by repackaging of materials after examination and the decontamination or disposal of equipment used.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Nanocomposite scintillator, detector, and method

A compact includes a mixture of a solid binder and at least one nanopowder phosphor chosen from yttrium oxide, yttrium tantalate, barium fluoride, cesium fluoride, bismuth germanate, zinc gallate, calcium magnesium pyrosilicate, calcium molybdate, calcium chlorovanadate, barium titanium pyrophosphate, a metal tungstate, a cerium doped nanophosphor, a bismuth doped nanophosphor, a lead doped nanophosphor, a thallium doped sodium iodide, a doped cesium iodide, a rare earth doped pyrosilicate, or a lanthanide halide. The compact can be used in a radiation detector for detecting ionizing radiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Heavy-ion versus {sup 3}He/{sup 4}He fusion-fission reactions: Angular momentum dependence of dissipation in nuclear fission

The stochastic Langevin model is employed to study dissipation properties in fission in the {sup 16}O + {sup 181}Ta {yields}{sup 197}Tl system by analyzing prescission neutron yields measured in this reaction. It has been found that the {sup 197}Tl nuclei undergo fission that is not in accordance with the standard Bohr-Wheeler statistical theory. A detailed comparison with previously published work in which fission excitation functions measured in {sup 3,4}He + {sup 197}Au {yields}{sup 200,201}Tl are shown to be in excellent agreement with the fission width formula predicted by the traditional models of nuclear fission suggests that nuclear dissipation strength may have an angular momentum dependence in addition to the known deformation and temperature dependence. Implications for the basic understanding of the observed abnormal rise in prescission particles at high energy and the need for further experimental confirmations are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Photodisintegration of heavy nuclei in the energy region above the giant dipole resonance

Experimental data on yields of multiparticle photonuclear reactions (involving the emission of up to seven neutrons from the nucleus involved) on {sup 197}Au, {sup 203,205}Tl, and {sup 209}Bi nuclei in the region extending from the giant dipole resonance to an energy of 67.7 MeV are presented. These data are compared with the results of modern theoretical calculations that take into account both the excitation of a giant dipole resonance (GDR) in a nucleus and the photodisintegration of quasideutrons (QD) in it. By and large, experimental data confirm the results of theoretical calculations-that is, only upon taking simultaneously into account both alternative photodisintegration mechanisms (GDR excitation and QD photodisintegration) can one describe these experimental data. The contribution of QD photodisintegration grows with increasing photon energy and neutron multiplicity and becomes dominant for reactions involving the emission of not less than five neutrons from the nucleus being considered. The integrated cross sections for the processes in question were estimated on the basis of simultaneously employing experimental yields of multinucleon photonuclear reactions and the respective cross-section shapes calculated theoretically.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Compositionally controlled metal-insulator transition in Tl{sub 2-x}In{sub x}TeO{sub 6}

Tl{sub 2}TeO{sub 6} and In{sub 2}TeO{sub 6} are both known to crystallize in the Na{sub 2}SiF{sub 6}-type structure. We find Tl{sub 2}TeO{sub 6} is metallic, whereas In{sub 2}TeO{sub 6} is an insulator. We have prepared a complete Tl{sub 2-x}In{sub x}TeO{sub 6} series in a search for a compositionally controlled metal-insulator transition that might be expected if a complete solid solution can be obtained. Unit cell edges and volume vary monotonically with no indication of a miscibility gap. The metal-insulator transition occurs at an x value of about 1.4, which can be rationalized on a percolation model. No superconductivity could be detected down to 5 K. -- Graphical abstract: A complete solid solution between Tl{sub 2}TeO{sub 6} and In{sub 2}TeO{sub 6} is formed. A compositionally controlled metal-insulator transition occurs in Tl{sub 2-x}In{sub x}TeO{sub 6} at an x value of about 1.5. No superconductivity could be detected down to 5 K. Display Omitted Research highlights: {yields} A complete solid solution between Tl{sub 2}TeO{sub 6} and In{sub 2}TeO{sub 6} is formed. {yields} A compositionally controlled metal-insulator transition occurs in Tl{sub 2-x}In{sub x}TeO{sub 6} at an x value of about 1.5, which can be rationalized on a percolation model. {yields} No superconductivity could be detected down to 5 K.

36 MATERIALS SCIENCE↗

Nuclear Data Sheets for A=182

Nuclear spectroscopic information for known nuclides of mass number 182 (Lu,Hf,Ta,W,Re,Os,Ir,Pt,Au,Hg, Tl,Pb) with Z=71 to 82 and N=111 to 100 have been evaluated and presented together with adopted energies and J{pi} of levels in these nuclei. No excited state data are yet available for {sup 182}Lu, while only limited structure information is available for {sup 182}Pb and {sup 182}Tl. Rotational band structures are known for {sup 182}Hg and {sup 182}Au but spin-parity assignments remain largely tentative. The decays of {sup 182}Lu, {sup 182}Hg, {sup 182}Au and {sup 182}Tl are not well established. The {sup 182}Hf isotope is of geophysical and astrophysical interest. This evaluation supersedes previous full evaluations of A=182 published by 1988Fi05 and 1975Sc13, and a selected (mainly high-spin) update of A=182 published by 1995Si04.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear Data Sheets for A = 207

Evaluated nuclear structure and decay data for all nuclei within the A=207 mass chain are presented. The experimental data are evaluated and best values for level and gamma-ray energies, quantum numbers, lifetimes, gamma-ray intensities, and other nuclear properties are recommended. Inconsistencies and discrepancies that exist in the literature are noted. This work supersedes the earlier evaluation by M.J. Martin (1993Ma73), published in Nuclear Data Sheets70, 315 (1993).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ultrashort-period lateral composition modulation in TlInGaAsN/TlInP structures

We prepared TlInGaAsN/TlInP quantum well structures using gas source molecular-beam epitaxy and characterized them by means of transmission electron microscopy and scanning transmission electron microscopy. It was found that naturally formed vertical quantum wells, so-called lateral composition modulation (LCM), with a periodicity of {approx}1 nm are formed in TlInGaAsN layers. We discuss their formation process using a simple kinetic Ising model for layer-by-layer growth, and point out that the formation of ultrashort-period LCM is a universal phenomenon in most of epitaxially grown III-V semiconductor alloys.

36 MATERIALS SCIENCE↗

(e, e'p) reaction at true quasielastic kinematics in {sup 16}O, {sup 12}C and {sup 208}Pb at JLab

The reactions {sup 16}O(e,e'p) {sup 15}N, {sup 208}Pb(e,e'p) {sup 207}Tl and {sup 12}C(e,e'p) {sup 11}B were measured in experiments E00-102 and E06-007 performed at JLab (VA, USA) at true quasielastic kinematics (x{sub B} = 1) with constant energy (omega) and momentum (q) transferred over a wide p{sub miss} range. These experiments address several open issues in nuclear structure such as the role of relativity and of long-range correlations in the description of nuclei as well as a possible dependence of the spectroscopic factors on Q{sup 2}. Preliminary experimental results and theoretical predictions from a fully relativistic DWIA model carefully averaged over the experimental acceptances are shown.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ambient Dose Equivalent measured at the Instituto Nacional de Cancerologia Department of Nuclear Medicine

Ambient dose equivalent values were determined in several sites at the Instituto Nacional de Cancerologia, Departmento de Medicina Nuclear, using TLD-100 and TLD-900 thermoluminescent dosemeters. Additionally, ambient dose equivalent was measured at a corridor outside the hospitalization room for patients treated with {sup 137}Cs brachytherapy. Dosemeter calibration was performed at the Instituto Nacional de Investigaciones Nucleares, Laboratorio de Metrologia, to known {sup 137}Cs gamma radiation air kerma. Radionuclides considered for this study are {sup 131}I, {sup 18}F, {sup 67}Ga, {sup 99m}Tc, {sup 111}In, {sup 201}Tl and {sup 137}Cs, with main gamma energies between 93 and 662 keV. Dosemeters were placed during a five month period in the nuclear medicine rooms (containing gamma-cameras), injection corridor, patient waiting areas, PET/CT study room, hot lab, waste storage room and corridors next to the hospitalization rooms for patients treated with {sup 131}I and {sup 137}Cs. High dose values were found at the waste storage room, outside corridor of {sup 137}Cs brachytherapy patients and PET/CT area. Ambient dose equivalent rate obtained for the {sup 137}Cs brachytherapy corridor is equal to (18.51{+-}0.02)x10{sup -3} mSv/h. Sites with minimum doses are the gamma camera rooms, having ambient dose equivalent rates equal to (0.05{+-}0.03)x10{sup -3} mSv/h. Recommendations have been given to the Department authorities so that further actions are taken to reduce doses at high dose sites in order to comply with the ALARA principle (as low as reasonably achievable).

62 RADIOLOGY AND NUCLEAR MEDICINE↗