Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TEST FACILITIES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Thermal modeling of the NASA-Ames Research Center Cryogenic Optical Test Facility and a single-arch, fused-natural-quartz mirror

A thermal model of the dewar and optical system of the Cryogenic Optical Test Facility at NASA-Ames Research Center was developed using the computer codes SINDA and MONTE CARLO. The model was based on the geometry, boundary conditions, and physical properties of the test facility and was developed to investigate heat transfer mechanisms and temperatures in the facility and in test mirrors during cryogenic optical tests. A single-arch, fused-natural-quartz mirror was the first mirror whose thermal loads and temperature distributions were modeled. From the temperature distribution, the thermal gradients in the mirror were obtained. The model predicted that a small gradient should exist for the single arch mirror. This was later verified by the measurement of mirror temperatures. The temperatures, predicted by the model at various locations within the dewar, were in relatively good agreement with the measured temperatures. The model is applicable to both steady-state and transient cooldown operations.

Ng, Y. S.↗

Radiation shielding for superconducting RF cavity test facility at A0

The results of Monte Carlo radiation shielding study performed with the MARS15 code for the vertical test facility at the A0 north cave enclosure at Fermilab are presented and discussed. The vertical test facility at the A0 north cave is planned to be used for testing 1.3 GHz single-cell superconducting RF cavities with accelerating length of 0.115 m. The operations will be focused on high accelerating gradients--up to 50 MV/m. In such a case the facility can be a strong radiation source [1]. When performing a radiation shielding design for the facility one has to take into account gammas generated due to interactions of accelerated electrons with cavity walls and surroundings (for example, range of 3.7-MeV electrons in niobium is approximately 3.1 mm while the thickness of the niobium walls of such RF cavities is about 2.8 mm). The electrons are usually the result of contamination in the cavity. The radiation shielding study was performed with the MARS15 Monte Carlo code [2]. A realistic model of the source term has been used that describes spatial, energy and angular distributions of the field-emitted electrons inside the RF cavities. The results of the calculations are normalized using the existing experimental data on measured dose rate in the vicinity of such RF cavities.

43 PARTICLE ACCELERATORS↗

Case study on the novel permitting and authorization of PacWave South, a US grid-connected wave energy test facility: Development, challenges, and insights

Marine energy (i.e., energy from waves, tides, currents, and rivers) in the United States is a nascent industry. In particular, permitting processes—an uncertainty for industry advancement that can be costly and time consuming to navigate—have rarely been tested and used for marine energy. The novelty of the marine energy industry and utilization of open ocean permitting processes that were not originally developed for marine energy have led to extensive efforts to gain consensus amongst state and federal regulatory agencies to authorize marine energy projects. In 2021, Oregon State University successfully completed permitting of a wave energy test facility, called PacWave South, off the coast of Oregon, which is designed to advance wave energy research and development. This article documents the multi-year process that Oregon State University used to receive federal and state authorization for a pre-permitted commercial-scale grid connected facility by detailing the development of the test facility, management of uncertainty and challenges, and key decisions. The PacWave South case study provides insights for the larger marine energy community as the industry advances towards commercialization.

16 TIDAL AND WAVE POWER↗

NASA Lewis Research Center's combustor test facilities and capabilities

NASA Lewis Research Center (LeRC) presently accommodates a total of six combustor test facilities with unique capabilities. The facilities are used to evaluate combustor and afterburner concepts for future engine applications, and also to test the survivability and performance of innovative high temperature materials, new instrumentation, and engine components in a realistic jet engine environment. The facilities provide a variety of test section interfaces and lengths to allow for flametube, sector and component testing. The facilities can accommodate a wide range of operating conditions due to differing capabilities in the following areas: inlet air pressure, temperature, and flow; fuel flow rate, pressure, and fuel storage capacity; maximum combustion zone temperature; cooling water flow rate and pressure; types of exhaust - atmospheric or altitude; air heater supply pressure; and types of air heaters - vitiated or nonvitiated. All of the facilities have provisions for standard gas (emissions) analysis, and a few of the facilities are equipped with specialized gas analysis equipment, smoke and particle size measurement devices, and a variety of laser systems. This report will present some of the unique features of each of the high temperature/high pressure combustor test facilities at NASA LeRC.

Bianco, Jean↗

Cryogenic and safety design of the future high field cable test facility at Fermilab

The HFVMTF (High Field Vertical Magnet Test Facility) is a new experimental facility under development at Fermi National Accelerator Laboratory (FNAL) to test large superconducting magnets (up to 20 tons weight and 1.3 m diameter) in a double bath superfluid helium cryostat (1.9 K and 1.2 bar). Coupled with a superconducting dipole magnet fabricated by Lawrence Berkeley National Laboratory (LBNL), this facility will be able to test future high-temperature superconductor (HTS) cables under a background magnetic field of 15 T for fusion magnets. This paper describes the design of the cryostat and its 1.4-meter diameter lambda plate, as well as the different components for a safe operation of the facility, even during critical events such a magnet quench or a vacuum breaking situation. The project is funded by US DOE Offices of Science, High Energy Physics (HEP), and Fusion Energy Sciences (FES).

43 PARTICLE ACCELERATORS↗

Testing Facility Uncertainty Analyses for RBCC Systems Testing

The Rocket Based Combined Cycle (RBCC) engine is expected to evolve based upon past combined-cycle propulsion test experience/data and new extensive test data. Currently, it is envisioned that a portion of the component and system testing will be pursued at NASA Stennis Space Center (SSC). To realize the greatest benefit of the test data, uncertainty analyses are being performed on the relevant RBCC components and systems to be tested at NASA SSC to ascertain the needed measurement requirements. These studies pertain to the existing E-Complex test stands as well as a new facility, E-4. This paper describes the approach used in the studies and gives examples to demonstrate the approach and the usefulness of the results. Future work will greatly increase the reliability of the test data while minimizing costs by focusing expenditures in the proper areas that are critical to program success and not allowing resources to be wasted in areas that are not significant relative to overall program goals.

Hudson, Susan T.↗

ALLOY SELECTION AND C-276 CODE DESIGN VALUE EXTENSION FOR ADVANCED MOLTEN SALT TECHNOLOGY TEST FACILITIES EXPERIMENTATION

Molten halide salts are being considered as working fluids for nuclear and concentrated solar power applications. High temperature molten fluoride and chloride salts are known to preferentially attack and deplete Cr in alloys, which leads to the use of high-Ni lower-Cr alloys in test facilities for advanced Molten Salt Technology. Alloys 600 and C-276 are two commercially available Ni alloys that have moderate Cr contents and are qualified to the maximum temperature of 649°C and 677°C (1,200°F and 1,251°F), respectively, in the Boiler and Pressure Vessel Code. Both alloys have good corrosion resistance to acids, are resistant to stress-corrosion cracking, and have long track records of use in the chemical industry. Comparatively, Alloy C-276 has a similar Cr content but much higher allowable stresses for temperatures greater than 600°C (1,112°F). Therefore, it has been considered as a structural material for test facilities that require operations at 700°C (1,292°F) or greater to develop high-temperature Molten Salt Technology. To meet the requirements, the current code design values were extended based on some experimental data. Analysis showed that above current Codified maximum temperature, strength of the alloy is mainly controlled by creep rupture life under the average stress, although the Sc creep rate criterion is close to the Favg.Savg rupture criterion. This paper presents the intended test facilities and the design requirements, alloy selection considerations, literature review, data analysis, and proposed allowable stress extension based on some creep test data for C-276 at temperatures greater than 677°C (1,251°F). Further research activities are also briefly mentioned.

Ren, Weiju↗

Evaluation of the Netherlands' International Test Facility for Smart Grids

The Netherlands Enterprise Agency (Rijksdienst voor Ondernemend Nederland, or RVO) engaged the U.S. National Renewable Energy Laboratory (NREL) for two primary purposes: to evaluate the International Test Facility for Smart Grids (ITF) sponsored by RVO and to learn best practices for integrated test facilities from NREL's Energy Systems Integration Facility (ESIF). This report covers the ITF evaluation and is largely based on a one-week visit to the Netherlands in November 2014.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Lead Coolant Test Facility Systems Design, Thermal Hydraulic Analysis and Cost Estimate

The Idaho National Laboratory prepared a preliminary technical and functional requirements (T&FR), thermal hydraulic design and cost estimate for a lead coolant test facility. The purpose of this small scale facility is to simulate lead coolant fast reactor (LFR) coolant flow in an open lattice geometry core using seven electrical rods and liquid lead or lead-bismuth eutectic coolant. Based on review of current world lead or lead-bismuth test facilities and research needs listed in the Generation IV Roadmap, five broad areas of requirements were identified as listed: (1) Develop and Demonstrate Feasibility of Submerged Heat Exchanger; (2) Develop and Demonstrate Open-lattice Flow in Electrically Heated Core; (3) Develop and Demonstrate Chemistry Control; (4) Demonstrate Safe Operation; and (5) Provision for Future Testing. This paper discusses the preliminary design of systems, thermal hydraulic analysis, and simplified cost estimate. The facility thermal hydraulic design is based on the maximum simulated core power using seven electrical heater rods of 420 kW; average linear heat generation rate of 300 W/cm. The core inlet temperature for liquid lead or Pb/Bi eutectic is 4200 C. The design includes approximately seventy-five data measurements such as pressure, temperature, and flow rates. The preliminary estimated cost of construction of the facility is $3.7M (in 2006 $). It is also estimated that the facility will require two years to be constructed and ready for operation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Comparative study with two reduced test facilities for air-cooled RCCS scaling law

Korea Atomic Energy Research Institute (KAERI) and Argonne National Laboratory (ANL) conducted steady-state tests at constant heat flux conditions to investigate the scale effect on heat removal behavior of the air-cooled Reactor Cavity Cooling System (RCCS). Two differently scaled-down test facilities were used in this study, KAERI’s ¼ scale with 4.0-m cavity height, and ANL’s ½ scale with 6.8-m cavity height. Two scaling laws were proposed to simulate the radiation across the cavity and the buoyancy-driven duct flow in the riser, respectively. The test matrix for KAERI and ANL test facilities focused on the scaling effect of the heated riser length with constant heat flux at the PMR200 RCCS design. The test results showed that mixed convection in the riser duct is an important factor for accurately extrapolating the thermo-fluid behavior in the prototype from the test results in the scale-down facilities. The system analysis code, GAMMA+, with improved heat transfer models predicted fairly well the air-cooled RCCS test data from two facilities. GAMMA+ analysis results showed that the predicted radiation fractions on the heated plate in the scale-down test conditions were larger than those on the reactor vessel in the prototype. The scaling law for air-cooled RCCS was improved by considering the mixed convection in the riser duct and the same radiation fraction on the heated plate. The mixed convection effect was calculated by the height ratio. The same radiation fraction provided a conservative extrapolation from the scale-down test results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Benchmark Specification for Select Experiments Conducted at the University of Wisconsin-Madison Thermal Stratification Test Facility

The Department of Energy (DOE)-Nuclear Energy University Programs (NEUP) supported the creation and operation of the Thermal Stratification Test Facility (TSTF) at the University of Wisconsin Madison (UWM) as part of a larger effort to understand thermal stratification behavior in liquid-metal-cooled reactors. The TSTF was designed to simulate transients in a reactor plenum that are known to cause thermal stratification. High-reliability and high-resolution measurements of the flow and temperature were collected for use as experimental benchmarks to support validation efforts for computational models. The results of these tests contribute to the greater understanding of thermal stratification behavior of liquid sodium under various configurations and operating conditions. The six TSTF tests selected for benchmarking are a set of forced circulation tests at a fixed flow rate with different Upper Internal Structure (UIS) configurations in the test section (no UIS, solid UIS, and a UIS with flow area of 4, 8, 12, and 100%). This report provides a complete description of the benchmark problems, including all key test facility details, descriptions of each test condition, and measured data for comparison with modeled results.

42 ENGINEERING↗

STEADY STATE MODELING OF THE MINIMUM CRITICAL CORE OF THE TRANSIENT REACTOR TEST FACILITY

With the advent of next generation reactor systems and new fuel designs, the U.S. Department of Energy (DOE) has identified the need for the resumption of transient testing of nuclear fuels. The DOE has decided that the Transient Reactor Test Facility (TREAT) at Idaho National Laboratory (INL) is best suited for future testing. TREAT is a thermal neutron spectrum, air-cooled, nuclear test facility that is designed to test nuclear fuels in transient scenarios. These specific scenarios range from simple temperature transients to full fuel melt accidents. DOE has expressed a desire to develop a simulation capability that will accurately model the experiments before they are irradiated at the facility. It is the aim for this capability to have an emphasis on effective and safe operation while minimizing experimental time and cost. The multi physics platform MOOSE has been selected as the framework for this project. The goals for this work are to identify the fundamental neutronics properties of TREAT and to develop an accurate steady state model for future multiphysics transient simulations. In order to minimize computational cost, the effect of spatial homogenization and angular discretization are investigated. It was found that significant anisotropy is present in TREAT assemblies and to capture this effect, explicit modeling of cooling channels and inter-element gaps is necessary. For this modeling scheme, single element calculations at 293 K gave power distributions with a root mean square difference of 0.076% from those of reference SERPENT calculations. The minimum critical core configuration with identical gap and channel treatment at 293 K resulted in a root mean square, total core, radial power distribution 2.423% different than those of reference SERPENT solutions.

Critical↗

Inlet Acoustic Data from a High Bypass Ratio Turbofan Rotor in an Internal Flow Component Test Facility: Supplemental Data Files

In February 2017, aerodynamic and acoustic testing was completed on a scale-model high bypass ratio turbofan rotor, R4, in an internal flow component test facility. The objective of testing was to determine the aerodynamic and acoustic impact of fan casing treatments designed to reduce noise. The baseline configuration consisted of the R4 rotor with a hardwall fan case. Data are presented for a baseline acoustic run with fan exit instrumentation removed to give a clean acoustic configuration.

Bozak, Richard F.↗

Tracer gas test in Net-Zero Energy Residential Test Facility

The Net-Zero Energy Residential Test Facility (NZERTF) at NIST was built in 2012 to support the development and adoption of cost-effective net-zero energy designs, technologies, and construction methods. It is two-story, and has four bedrooms, three bathrooms, and an open living room, dining room, and kitchen space. The NZERTF also has a basement and attic, both located within the conditioned space because the thermal and air-moisture barriers encompass the basement walls and attic roof. Transfer grilles link the living spaces to these two zones. The central heating and cooling system includes an air-toair heat pump, which delivers air to the basement, first and second floors. The heat pump has a cooling capacity of 7.6 kW and a heating capacity of 7.8 kW. The indoor unit is in the basement and ductwork runs along the basement ceiling. A balanced heat recovery ventilator (HRV) is installed in the basement and has its own dedicated ductwork. The HRV supplies 47 L/s of outdoor air to the house, with supplies on the first floor (in the kitchen/dining area) and in each of the three second-floor bedrooms. Air from the first-floor bathroom and both second-floor bathrooms is returned to the HRV before being exhausted, though the HRV was turned off during the tests. The house also has a range hood exhaust and a clothes dryer exhaust, both of which were turned off for the tests. The temperature of the house was measured and the operation of the space conditioning system, including its recirculating air distribution fan, were controlled by a commercially available thermostat.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design of the cryostat for High Field Vertical Magnet Testing Facility at Fermilab

High Field Vertical Magnet Test Facility (HFVMTF) is a joint project between the Office of High Energy Physics (HEP) and the Office of Fusion Energy Sciences (FES). Its construction is currently under way at Fermi National Accelerator Laboratory (Fermilab). As a part of the project a new double bath superfluid helium cryostat has been designed. The cryostat can accommodate magnets with up to 20 tonne weight and 1.3 m diameter. This paper discusses challenges and solutions for cryostat, lambda plate and heat exchanger design, and presents results of performance analysis.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

RELAP5-3D Input Model for the High Temperature Test Facility

A RELAP5-3D model of the High Temperature Test Facility at Oregon State University has been developed. The model includes the systems, components, and controls needed to perform code assessment calculations using data from the facility. Details of the model are provided. The input was developed for RELAP5-3D Version 4.4.2.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗