Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

TechEdSat 7, 10, 13, 15: Exo-brake Experiments on the ISS, First Virgin Orbit, and First Firefly-Alpha Test Flights

The TechEdSat flight series (TES-n), developed by the Nano Orbital Workshop (NOW) group at NASA Ames, has been studying cube satellite re-entry technologies with a focus on Exo-Brake drag device research. An exo-atmospheric braking device, the Exo-Brake uses the tenuous upper atmosphere acting in a free molecular flow regime to enable controllable adjustment of the drag profile of the host spacecraft, currently enabling rapid disposal of small spacecraft after mission conclusion, and eventual targeted de-orbit to a desired entry point at the Von Karman line, or approximately 100km in altitude. The TES-7 mission, flown on the first successful Virgin Orbit flight January 17, 2021, was injected into a 500km, 61-degree inclination orbit, with an expected orbital lifetime of approximately ten years. After successful deployment of a unique hydrogen gas-cell inflation design ‘disposal’-type Mylar Exo-Brake intended to rapidly de-orbit the spacecraft, the maximum expected orbital lifetime of the TES-7 spacecraft was successfully reduced from ten years to 1.3 years, an 87% reduction in orbit lifetime via a passive, fuel-less system. The subsequent TES-13 mission utilized a new, less complex ‘disposal’-type Exo-Brake design made from collapsible rigid struts rather than inflated struts to reduce the engineering, construction, and safety complexities introduced by the prior hydrogen gas inflation design. The rigid strut Exo-Brake design is stowed via rotational compression and deploys using only stored spring energy once released via electronic actuator. This new rotation compression storage design has become the new Exo-Brake design standard used on TES missions thanks to its simplicity. Following on the success of this new Exo-Brake design demonstrated by TES-13, the design was further refined to enabled active manipulation of the Exo-Brake effective drag area though a winch-like system. Both the TES-10 and TES-15 spacecraft were equipped with geometrically similar Exo-Brake devices capable of such active drag modulation, with the intent of studying the operational impact of having such devices on cube satellite missions. To increase the survival time of the Exo-Brake at low altitudes and thus gain more experiment time and better guidance capability, TES-15 was equipped with a modulated Exo-Brake constructed from 3M™ Nextel™ 440 ceramic oxide fiber, the same fabric material used in the Space Shuttle TPS system, rather than Mylar. After launching on Alpha Flight 2 October 1st, 2022, Firefly’s first successful launch, TES-15 met the same modulation restrictions as TES-10, with modulation prohibited above 200km to avoid possible collision with other spacecraft. In this case, a low deployment orbit caused an extremely short mission life, which, coupled with delayed spacecraft identification, exacerbated collision concerns and caused performance data of the high-temperature Exo-Brake design to be inconclusive. As such, the Nano Orbital Workshop has taken a new approach of only conducting modulated Exo-Brake research on missions deploying below ISS altitude to avoid collision avoidance restrictions, and is working to improve spacecraft identification and location reporting techniques to increase experiment durations. Upcoming TES mission will therefore use one of two classes of Exo-Brake depending on their target altitude, as to be described in the submission.

Marcus Murbach↗

The Potential Role of Concentrating Solar Power within the Context of DOE's 2030 Solar Cost Targets

To continue the momentum for cost reduction in solar technologies, DOE recently established 2030 cost targets for that would make solar one of the lowest-cost sources of new electricity in the United States. The potential impacts of achieving the 2030 cost targets for solar photovoltaics (PV) were recently explored in a related publication, which found significant potential for solar PV deployment and generation, particularly when coupled with low-cost storage. Building on this previous report, the present analysis evaluates the potential impacts of simultaneously achieving the 2030 cost targets for both PV and concentrating solar power with thermal energy storage (CSP-TES) systems in the contiguous United States, with a detailed evaluation of the role that CSP-TES plays in realizing those impacts. The evolution of the contiguous U.S. electricity system is evaluated with NREL's Renewable Energy Deployment System (ReEDS) model, which has been specifically designed to represent the time and locational value of renewable generation technologies in the U.S. power system. This analysis suggests achievement of the SunShot cost targets for CSP-TES might lead to dramatic growth in CSP-TES capacity, with accelerated deployment after the 2030 target is achieved. Based on our representation of the 2030 cost targets in ReEDS, economically-competitive CSP-TES could primarily be deployed in a dispatch able, high-capacity factor configuration, which allows it to provide valuable services to the power sector and results in a generation profile for CSP-TES that is complementary to that of variable PV. Aggressive cost reductions for CSP-TES could also make such a configuration economically competitive across the contiguous United States, which is a a result that warrants additional analysis in terms of potential siting, permitting, regulatory, and construction challenges in these new regions and markets. The modeled capacity expansion of both CSP-TES and PV in our scenarios that achieve the 2030 cost targets requires most growth in transmission capacity at a pace that is consistent with historical buildout rates, and could result in reduced electricity prices and power system costs, water usage, and air emissions. Finally, sensitivity analysis suggests that the cumulative capacity and geographic extent of CSP-TES deployment in our low-cost solar scenarios is highly sensitive to the post-2030 cost reductions for CSP-TES and future price of natural gas, and that significant competition exists among renewable energy and energy storage technologies, assuming aggressive cost reductions for each. For example, significant competition between CSP-TES and PV with battery storage indicates the similar role that these systems play in capacity planning and grid operations, as well as the fact that low-cost battery storage would help improve the capacity value of low-cost PV into the future.

14 SOLAR ENERGY↗

Phenomenon Identification and Ranking Table Analysis for Thermal Energy Storage Technologies Integration with Advanced Nuclear Reactors

This report provides an overview of the Phenomena Identification and Ranking Table (PIRT) analysis of thermal energy storage (TES) systems for possible integration with various types of advanced nuclear power plants (NPPs). Advanced NPPs will potentially need to operate in environments where power generation flexibility is more highly valued than the stability or baseload generation capability for conventional demand curves. TES systems would enable NPPs to respond nimbly to market variability and could also position advanced NPPs to participate differently in restructured markets, thus further enhancing their economic competitiveness. TES systems could also benefit the electric grid by eliminating the need for peaking plants, as well as by improving the economic performance of baseload NPPs. While TES technologies afford a unique opportunity to address many of these challenges, the applicability of these systems is also complicated by the fact that various advanced NPPs are designed differently, each with its own temperature range, size, operating fluids, and operating conditions. Hence, TES systems face significant barriers to investment, as more information on their compatibility and performance metrics is needed to quantify the advantages provided by each, as well as the challenges these technologies might face if coupled with a particular type of advanced NPP. This report explores the possibility of integrating a wide variety of TES technologies with various categories of advanced NPPs, based on their operating characteristics. To help users and developers decide which TES technology is best suited to a particular category of advanced NPPs, this research developed a PIRT of 10 TES systems that could potentially be coupled with advanced NPPs, which themselves are divided into nine categories based on their operating conditions. Each advanced NPP category is evaluated for compatibility with the 10 TES systems by assembling and discussing a database of information concerning 10 engineering questions (defined herein in as figures of merit [FOMs]), such as: technology readiness level (TRL), temperature compatibility, energy density, size, cycle frequency, ramp time, realignment frequency, geographic needs, environmental impact, and interventions. By assembling a database of information concerning the TES technologies’ compatibility with various advanced NPP systems, this study can help developers acquaint themselves with a particular TES technology before choosing to build a new integrated installation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The Impact of Transition-Edge Sensor Design on Internal Thermal Fluctuation Noise and Thermal Conductance

The measured noise in transition-edge sensor (TES) microcalorimeters with a Mo/Au bilayer has been shown to have a significant contribution from internal thermal fluctuation noise (ITFN) between the absorber and the TES. Previous measurements showed the relevant thermal link leading to the noise was the thermal conductance of the TES bilayer, and ITFN has been shown to correlate with the sheet resistance of the TES. As a result, ITFN is particularly significant in devices with a large bilayer sheet resistance. However, because of more favorable transition shapes, such high resistance devices have recently been shown to be preferable under alternating current bias, which is required for the frequency division multiplexed readout baselined for the X-ray Integral Field Unit (X-IFU) instrument on the ATHENA satellite. Therefore, it is important to investigate how else to minimize the ITFN beyond changes to the sheet resistance. In this presentation, we will discuss our investigation of how changes to the TES design can affect ITFN for a fixed sheet resistance. We will present how ITFN is altered by changes to the aspect ratio of the TES, the addition of normal metal banks parallel to the TES current direction, and the size and position of the connections between the absorber and the TES. We will also discuss how these design changes impact the superconducting transition shape, and the thermal conductance from the TES to the thermal bath. These results may provide routes for further improvements of TES performance, and a deeper understanding of the physics of the thermal network in a TES microcalorimeter.

Nicholas A Wakeham↗

High-Fidelity and High-Performance Computational Simulations for Rapid Design Optimization of Sulfur Thermal Energy Storage

Industrial process heating (IPH) accounts for approximately 70% of US manufacturing energy use and is primarily produced by fossil fuel combustion. Approximately 1500 TWht (approximately 60%) of IPH demand is in the temperature range of 100-300. Industrial applications in this temperature range include drying, hydrothermal processing, thermal enhanced oil recovery, food and beverage, bioethanol production, etc. Cost-effective thermal energy storage (TES) that increases the utilization of waste and renewable heat (solar, geothermal, etc.) could provide significant energy savings and reliable heat sources, decrease emissions, and increase US manufacturing competitiveness through reductions in fuel consumption. TES development has historically been dominated by technologies suitable for deployment with concentrating solar power (CSP). State-of-the-art thermal storage deployed commercially with power tower CSP plants uses a 60%/40% NaNO3/KNO3 molten salt and operates between temperatures of approximately 280 degrees Celsius and 570 degrees Celsius using a two-tank configuration. However, these nitrate salts are unsuitable for operation outside of this temperature range due to a high freezing point of approximately 220 degrees Celsius, and limits on high-temperature salt stability and corrosion resistance of containment alloys. Other materials being investigated for TES include those based on: (1) sensible energy storage (various molten salt compositions, inert solid particles, rocks or pebble beds, sulfur, water, concrete, graphite, etc.), (2) latent energy storage in materials that undergo solid-liquid phase change at relevant temperatures (organic materials for low-temperature applications, inorganic salts and/or metals for high-temperature applications), or (3) thermochemical energy storage (hydrides, hydroxides, carbonates, metal oxides, etc.). The application temperature and challenges pertaining to storage material and/or containment cost, energy density, long-term thermal and cyclic stability, and charge/discharge heat transfer effectiveness drive material selection for a given IPH or electricity generation application. Sulfur is a cheap commodity at $80/ton compared to $1100 - 1300/ton for conventional salts. When using a metric of storage cost per kWh, sulfur costs around 2-3 $/kWh. Previous sulfur TES development focused on high temperature (>600 degrees) concentrated solar power applications with sulfur encapsulated in pipes and flow of gaseous HTF (air) in the shell side. However, for lower-temperature IPH applications in the range of approximately 100-300 degrees Celsius Element 16 adopted a compact and scalable TES design with molten sulfur in the shell and HTF pipes submerged in the molten sulfur bath. The low-cost molten sulfur TES for dispatchable IPH has deployment potential for broad applications. The spatial and temporal evolution of the HTF and sulfur temperature is critical to the TES system performance, and thus detailed modeling can improve understanding of the performance and facilitate design improvements. Using high performance computing and computational fluid dynamics (CFD) a low-cost molten sulfur thermal energy storage (TES) system for industrial process heating (IPH) applications was developed. The unique challenges in CFD modeling of sulfur TES are the sharp property changes of sulfur relevant to the working temperatures. Above 159, liquid sulfur undergoes polymerization, and the viscosity of sulfur rapidly increases by several orders of magnitude between 159 degrees Celsius and 188 degrees Celsius, followed by a decrease in viscosity beyond 188 degrees Celsius due to thermal bound dissociation. In addition, various concentrations of H2S impurities can also modify sulfur viscosity. This numerical challenge is especially relevant to transient simulation of the sulfur TES charging and discharging processes as the extreme property variations limit the applicability of traditional heat transfer correlations. Transient CFD simulations including the temperature-dependent sulfur properties and geometric complexity of the TES design were used to predict the effect of natural convection during charging and discharging on the heat transfer process, sulfur temperature uniformity, charge/discharge rates, and performance of the storage devices. The CFD model was validated with experimental results for a full charge and discharge cycle. The work will show 3D and 2D simulation comparisons aimed to facilitate rapid design iterations and a machine learning based design optimization approach.

CFD↗

Integration of a thermoelectric subcooler with an air‑source heat pump to enhance heating capacity and dehumidification

This study presents an innovative configuration of a thermoelectric subcooler (TES) integrated with an air-source heat pump (ASHP). The TES is installed in the liquid line, where it absorbs heat from the refrigerant. On its hot side, it discharges heat to the return air in heating mode or to the supply air in cooling mode, enabling year-round operation. The ASHP–TES system was evaluated under various conditions to reduce supplemental heating needs and improve dehumidification. Experimental heating tests revealed that activating the TES increased the heating capacity by 12%–20%. However, this occurred with a 7.6%–10% reduction in heating coefficient of performance (COP). In cooling mode, TES operation significantly improved moisture removal. The TES reduced the sensible heat ratio (SHR) and enhanced dehumidification, removing 20%–50% more moisture than a conventional system when meeting the same sensible load. The TES can be turned off to use the refrigerant subcooler for reheat supply air or turned on to substantially boost dehumidification. When meeting the same latent load, the ASHP–TES system achieved up to 33% energy savings compared with a conventional ASHP using resistance heating. Relative to a conventional ASHP paired with a whole-house dehumidifier, the ASHP–TES system provided up to 20% energy savings. These findings underscore the potential of TES integration to improve latent load control and enhance overall energy efficiency in hybrid ASHP systems, especially in cold and humid climates.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Mapping thermal energy storage technologies with advanced nuclear reactors

Advanced nuclear power plants (NPPs) will potentially need to operate in environments where power generation flexibility is more highly valued than the stability or baseload generation capability for conventional demand curves. Thermal energy storage (TES) systems would enable NPPs to respond nimbly to market variability and could also position advanced NPPs to participate differently in restructured markets, thus further enhancing their economic competitiveness. TES systems could also benefit the electric grid by eliminating the need for peaking plants, as well as by improving the economic performance of baseload NPPs. While TES technologies afford a unique opportunity to address many of these challenges, the applicability of these systems is also complicated by the fact that various advanced NPPs are designed differently, each with its own temperature range, size, operating fluids, and operating conditions. Hence, TES systems face significant barriers to investment, as more information on their compatibility and performance metrics is needed to quantify the advantages provided by each, as well as the challenges these technologies might face if coupled with a particular type of advanced NPP. This study explores the possibility of integrating a wide variety of TES technologies with various categories of advanced NPPs, based on their operating characteristics. To help decision makers, users and developers decide which TES technology is best suited to a particular category of advanced NPPs, this research present a Phenomena Identification and Ranking Table (PIRT) analysis of 10 TES systems that could potentially be coupled with advanced NPPs, which themselves are divided into nine categories based on their operating conditions. Then, each advanced NPP category is evaluated for compatibility with the 10 TES systems by assembling and discussing a database of information concerning 10 engineering questions, defined herein in as figures of merit (FOMs), such as: technology readiness level (TRL), temperature compatibility, energy density, size, cycle frequency, ramp time, realignment frequency, geographic needs, environmental impact, and interventions. By assembling a database of information concerning the TES technologies' compatibility with various advanced NPP systems, this study can help developers acquaint themselves with a particular TES technology before choosing to build a new integrated installation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Novel thermal energy storage component: Development, performance, and phase transition diagnosis

Thermal energy storage (TES) using phase change materials (PCMs) is a promising technology for capturing and storing excess thermal energy for later use. However, challenges such as poor heat transfer efficiency and a lack of modular, scalable designs have limited widespread adoption of TES in real-world applications. This study developed and evaluated modular brick-type and blade-type TES prototypes featuring an aluminum housing, an embedded serpentine coil for active or passive thermal exchange, and a cost-effective metal mesh to enhance PCM thermal conductivity. The blade-type TES achieved notable geometric efficiency, with a thickness-to-length ratio of 0.03 and a thickness-to-width ratio of 0.08, enabling highly compact and modular thermal storage suitable for space-constrained applications. The paper presents a detailed evaluation of the TES prototypes’ performance. The comparative analysis indicated that the TES prototypes provide a highly cost-effective, thermally optimized alternative for compact energy storage and load shifting. A novel diagnostic technique was also introduced: using a portable endoscope to capture real-time visualizations of PCM phase transitions inside the TES. This method provides critical insights into internal heat transfer mechanisms, identifies potential issues, and offers valuable support for optimizing the TES design and developing the control algorithm. Overall, the modular brick-type and blade-type TES designs demonstrated in this work provide a scalable, efficient, and economically viable solution for advancing TES across residential, commercial, and industrial sectors. The designs’ compact structure, enhanced thermal performance, and integrated diagnostic capabilities make them strong candidates for future deployment in energy-efficient systems.

Gao, Zhiming [ORNL] (ORCID:0000000271397995)↗

Design analysis of a particle-based thermal energy storage system for concentrating solar power or grid energy storage

Energy storage is becoming indispensable for expanding renewable energy integration, and it is critical to the future low-carbon energy supply. Large-capacity, grid scale energy storage can support the integration of solar and wind power and support grid resilience with the diminishing capacity of baseload fossil power plants. With the development of thermal energy storage (TES) for concentrating solar power systems, standalone TES for grid integration becomes attractive due to the declining renewable generation cost and an increasing need for energy storage. The standalone TES system introduced in this paper can play a big role in the carbon-free energy future with capacity larger than batteries and cost likely lower than other energy storage methods such as pumped storage hydropower and compressed air energy storage, both of which also have geological limitations. To this end, we describe a TES system that uses stable, inexpensive solid particles as a TES media to provide scalable, low cost energy storage. The particle-based TES has the ability to drive various thermal power cycles including conventional steam-Rankine, air Brayton turbine with combined-cycle ability, or the emerging supercritical carbon dioxide Brayton power cycle. This work describes the containment design method including a concrete silo and an internal-insulation layer for the particle-TES system. The economic analysis shows significantly low storage cost when the particle-TES is integrated with Brayton combined-cycle power generation. The paper shows the design approach of the particle-TES system and its economic potential for bulk energy storage. The advantage of the particle-TES system as a promising bulk energy storage method is its ability to economically support dispatchable renewable grid penetration for larger capacity and longer discharging hours than current battery storage technologies.

25 ENERGY STORAGE↗

Design of Particle-Based Thermal Energy Storage for a Concentrating Solar Power System

Solid particles can operate at higher temperature than current molten salt or oil, and they can be a heat-transfer and storage medium in a concentrating solar power (CSP) system. By using inexpensive solid particles and containment material for thermal energy storage (TES), the particle-TES cost can be significantly lower than other TES methods such as a nitrate-salt system. The particle-TES system can hold hot particles at more than 800 degrees C with high thermal performance. The high particle temperatures increase the temperature difference between the hot and cold particles, and they improve the TES capacity. The particle-based CSP system is able to support high-efficiency power generation, such as the supercritical carbon-dioxide Brayton power cycle, to achieve >50% thermal-electric conversion efficiency. This paper describes a solid particle-TES system that integrates into a CSP plant. The hot particles discharge to a heat exchanger to drive the power cycle. The returning cold particles circulate through a particle receiver to absorb solar heat and charge the TES. This paper shows the design of a particle-TES system including containment silos, foundation, silo insulation, and particle materials. The analysis provides results for four TES capacities and two silo configurations. The design analysis indicates that the system can achieve high thermal efficiency, storage effectiveness (i.e., percentage usage of the hot particles), and exergetic efficiency. An insulation method for the hot silo was considered. The particle-TES system can achieve high performance and low cost, and it holds potential for next-generation CSP technology.

14 SOLAR ENERGY↗

Core Temperature Measurement During Submaximal Exercise: Esophageal, Rectal, and Intestinal Temperatures

The purpose of this study was to determine if intestinal temperature (Tin) might be in acceptable alternative to esophageal (Tes) and rectal temperature (Trec) to assess thermoregulation during supine exercise. We hypothesized that Tin would have values similar to Tes and a response time similar to Trec, but the rate of temperature change across time would not be different between measurement sites. Seven subjects completed a continuous supine protocol of 20 min of rest, 20 min of cycle exercise at 40% peak oxygen consumption (VO2pk), 20 min of cycle exercise at 65% V02pk, and 20 min of recovery. Tes, Trec, and Tin were recorded each min throughout the test. Temperatures were not different after 20 min of rest, but Trec was less than the Tes and Tin at the end of the 40% and 65% VO2pk stages. After 20 min of recovery, Tes was less than either Trec or Tin, which were not different from each other. Time to threshold for increased temperature from rest was greater for Trec than Tes but not different from Tin. Time to reach peak temperature was greater for Tin and Trec than Tes. Similarly, time to a decrease in temperature after exercise was greater for Trec than Tes, but not different from Tin. The rate of temperature change from threshold to the end of the 40% VO2pk stage was not different between measurement sites. However, the rate of change during recovery was more negative for Tes than Tin and Trec, which were different from each other. Measurement of Tin may he an acceptable alternative to Tes and Trec with an understanding of its limitations.

Lee, Stuart M. C.↗

An assessment of existing barriers to market adoption of thermal energy storage in buildings based on interviews with stakeholders

The United States administration recently established a goal of reducing greenhouse gas emissions by half below 2005 levels by 2030 and becoming a carbon-neutral economy by 2050. The transition to renewable energy sources may be significantly aided by energy storage. Energy storage could smooth the delivery of variable or intermittent renewable energy sources such as wind, hydro, and sun by storing excess renewable energy when it’s available and delivering it back when renewable energy production is low. Thermal energy storage (TES) is a way that stores thermal energy by heating or cooling a storage medium, which is then used for space heating and cooling, industrial processes, or power generation purposes later. This TES operation could lessen the demand for electricity in both the winter's and the summer's peak hours of electricity. While there are various studies that focus on the advancements and successes of TES technology, less attention is placed on its market adoption. Therefore, the current study undertakes survey-based interview research to understand the existing market barriers hindering TES application in buildings. A series of interviews were performed in this study with individuals from various backgrounds, ranging from homeowners to market specialists who work for TES manufacturers and utility companies. According to the responses obtained during the interviews, they strongly believe that TES has a high potential to contribute to the nation's grid stability and decarbonization goals, however, there are several barriers that prevent homeowners and heat pump manufacturers from investing in TES applications. The current study divided the responses from various background groups into categories to better understand the current challenges for TES applications in buildings. These responses range from payback concerns from homeowners to the need to develop a new metric to represent the benefits of TES from the heat pump and TES manufacturers. The findings from this study can be used by policymakers, utility companies, and manufacturers to better understand present obstacles and develop strategies to overcome them.

Prem Anand Jayaprabha, Jyothis Anand↗

Influence of Thermal Energy Storage Integration Strategy on System Performance and Refrigerant Charge for Small-Scale R290 Heat Pumps

As small-scale (2.5 – 5 kW) heat pumps across the US increase straining the grid during peak hours, integrated heat pump thermal energy storage (HP-TES) systems can assist by load shifting. However, challenges arise when assembling these systems, as direct refrigerant-phase change material (PCM) heat exchangers (HXs) increase refrigerant charge, and indirect secondary loops degrade HP-TES performance. In this work, direct and indirect HP-TES configurations were sized using commercially available HXs to compare the available load shift time and performance at similar refrigerant charges. For the same indirect 5 kW HP-TES refrigerant charge, directly HP-TES can operate up to 72 and 145 minutes in cooling and heating modes, respectively, using small diameter tubes. Using Modelica, COP increases for direct and indirect HP-TES were 22% and 9%, respectively, given the parasitic losses in the indirect HP-TES. Overall, small-scale direct HP-TES can have comparable refrigerant charges with indirect HP-TES maximizing COP improvements.

25 ENERGY STORAGE↗

Demand reduction and energy saving potential of thermal energy storage integrated heat pumps [Réduction de la demande et potentiel d'économie d'énergie des pompes à chaleur avec stockage d'énergie thermique intégré]

A heat pump (HP) moves heat from a low-temperature source to a high-temperature sink with an input of energy. Often, one temperature body fluctuates with time (e.g., diurnal ambient temperature), causing the HP efficiency to vary. Integrating thermal energy storage (TES) into a HP system adds a third temperature body, enabling the HP to be advantageously coupled to any two: the application, the ambient, or the TES at strategic times. Although TES integration with HPs is an important emerging technology to lower energy consumption and decrease energy demand during critical times, the favorable circumstances for TES integration are poorly understood. Here, this paper establishes the energy reduction and demand reduction potential of TES-integrated HPs with both analytical and numerical HP models. All possible temperature arrangements are considered for HP-TES systems with two fixed temperature bodies (application and TES) and one variable temperature (ambient). Results show that overall energy savings are most attainable when the TES temperature is near the application temperature, whereas a large temperature difference between the TES and the application leads to the most peak demand reduction. The potential for overall energy savings increases as the magnitude of ambient temperature fluctuations increases.

25 ENERGY STORAGE↗

Cost targets to achieve commercially viable thermal storage in buildings

To mitigate the variation in demand on the electric grid, thermal energy storage (TES) is an alternative to electric batteries or installing new peaking power plants. Stakeholders and policy makers across the United States have expressed interests in promoting TES, as demonstrated by the US Department of Energy’s Grid-Interactive Efficient Buildings program and the efforts of various state legislatures. However, the cost value provided by TES are unclear. If reliable cost benefits were determined, stakeholders would have a clearer picture of the financial returns that can be gained from their investment in TES. In this report, EnergyPlus was used to perform whole-building simulations for two residential buildings in Indianapolis and Atlanta. The HVAC system in both buildings were equipped with phase change material TES. The TES tank was charged in off-peak hours and discharged in peak hours to perform load shifting. First, the economic value implied by existing time-of-use (TOU) rates offered by utility companies was analyzed via whole-building simulation. Second, existing demand reduction (DR) incentives sourced from 3 different electrical grid administrators (i.e., California, Texas, and New England region) were surveyed to determine their implied value. Lastly, the economic value implied by different types of deferred peak power plants were reviewed. The full value of TES to the entire society consists of value to the utility, OEMs, facility installers, and other stakeholders. This report focuses on the value to the utility with emphasis on the deferred capital of peak power plant. The value from the deferred capital of peak power plant is manifested to the customer in the form of demand reduction program and Time-of-Use utility rate program. In this report, an initial proxy of the value of TES is made by assuming the deferred capital cost of power plant is the full value to reduce peak demand. Three levels of financial value of TES systems were assessed. Two are currently available to some residential customers: (1) the benefit from TOU pricing alone and (2) the benefit from TOU pricing in combination with DR incentive programs. The third level was computed as the full cost of deferred capital cost of peaking power plants. This represents the potential value that could be gained by the utilities or conceivably be offered to consumers.

25 ENERGY STORAGE↗

A Technical and Economic Assessment of LWR Flexible Operation for Generation and Demand Balancing to Optimize Plant Revenue

With increased penetration of subsidized variable renewable energy (VRE) resources and competition from low natural gas prices, existing light water reactor (LWR) nuclear power plants (NPPs) are struggling to remain economically competitive. This work examines the potential economic competitiveness of various thermal energy storage (TES) technologies when coupled directly or indirectly with a NPP. To highlight their relative economic competitiveness, we contrast several energy storage solutions in stochastic dispatch optimization. We leverage data from recent work analyzing a range of TES technologies with varying capital costs, performance, and technology readiness level (TRL) to establish our case. We explore inserting these technologies into an electricity market with existing nuclear generation and large projected variable renewable energy (VRE) penetration. Although these technologies' projected capital costs may make them unlikely candidates in their current state, this analysis demonstrates a high-fidelity techno-economic analysis of energy storage. Furthermore, as the projected cost of energy storage technologies evolves, this analysis sets a precedent for similar future investigations. One region with projected trends that may be unfavorable for existing nuclear capacity is the New York Independent System Operator (NYISO) market. New York state’s baseload generation has been historically provided by fossil-fired and nuclear assets. However, amid economic pressures from subsidized VREs and low natural gas prices, the state has recently deactivated Indian Point nuclear power plant units 2 and 3. Furthermore, the state plans to meet its zero-emission generation target by 2040 by replacing fossil-fired capacity with significant investments in VRE resources like wind and solar photovoltaic (PV) and battery storage. Increased intermittent resource penetration lowers the baseload power requirement, adding further economic pressure to the state’s three remaining NPPs still in operation. With three NPPs still in operation in New York, this work analyzes potential economic benefits to NPPs on the New York grid when directly or indirectly coupled with various TES technologies. This work requires two modeling steps to analyze the potential economic benefits of various system configurations of the TES directly or indirectly coupled with nuclear. First, this analysis leverages capacity expansion modeling by experts at the Electric Power Research Institute (EPRI). Using their deterministic capacity expansion model, U.S. Regional Economy, Greenhouse Gas, and Energy (US-REGEN), EPRI analysts evaluated the capacity and generation evolution of the New York state energy market under four projection scenarios. These four projection scenarios were developed to represent the potential evolution of the capacity and generation in NYISO from 2015 to 2050 under various economic, technology, and policy constraints. The results from these capacity expansion models are then used as boundary conditions in the second modeling step. The second modeling step uses the Holistic Energy Resource Optimization Network (HERON) for a set of stochastic techno-economic analyses (STEAs) to investigate the potential increase in the economic viability of various configurations of the TES. With no current capacity expansion capabilities, HERON takes the data generated from US-REGEN for 2050 to generate synthetic load, solar, and wind data. Then HERON economically optimizes the capacity and dispatch of the various TES configurations. The potential economic benefit is the differential net present value (NPV) of the TES configurations from the no-TES baseline. As a stochastic techno-economic analysis package, HERON introduces uncertainty into the economic metrics, while US-REGEN trades resolution for reduced computational complexity. Using HERON also allows the modeling of direct thermal coupling, a feature not common in capacity and dispatch models. As expected, with high capital costs, the costs of introducing energy storage for all the technologies considered outweighed the potential economic benefit of this strategy for flexible plant operation. The benefit of this analysis is primarily in demonstrating a workflow that examines innovative solutions to increase NPP revenue via TES coupling. HERON’s stochastic capacity and dispatch optimization process used in this work has proven an effective tool in observing and evaluating the impact of introducing storage technologies in a grid energy system.

25 ENERGY STORAGE↗

Quantification of Energy Savings and Demand Reduction for a Heat Pump Integrated with Thermal Energy Storage (Final Report)

To mitigate the variation in demand on the electric grid, thermal energy storage (TES) is an alternative to electric batteries or installing new peaking power plants. Stakeholders and policy makers across the United States have expressed interests in promoting TES, as demonstrated by the US Department of Energy’s Grid-Interactive Efficient Buildings program and the efforts of various state legislatures. However, the cost value provided by TES are unclear. If reliable cost benefits were determined, stakeholders would have a clearer picture of the financial returns that can be gained from their investment in TES. The study in this report is conducted by ORNL with collaboration with Emerson the Helix Innovation Center. In the first part of this report, EnergyPlus was used to perform whole-building simulations for two residential buildings in Indianapolis and Atlanta. The HVAC system in both buildings were equipped with phase change material TES. The TES tank was charged in off-peak hours and discharged in peak hours to perform load shifting. First, the economic value implied by existing time-of-use (TOU) rates offered by utility companies was analyzed via whole-building simulation. Second, existing demand reduction (DR) incentives sourced from 3 different electrical grid administrators (i.e., California, Texas, and New England region) were surveyed to determine their implied value. The study suggests that the traditional value analysis that focuses on ROI for the building owner significantly undervalues TES technology making economic viability difficult. A more comprehensive value analysis that includes peak demand management and deferred capital for peaking power plants shows that TES should be economically viable but here the value is greater for the utility and requires large market penetration and aggregation to fully realize the benefits. Therefore, to facilitate commercialization, new business models are needed that include a broader range of stakeholders and distribute the value of TES proportionally. In the 2 nd part of this project, the benefits of a novel phase change material (PCM) integrated heat pump configuration were evaluated via detailed component based simulation. A one-dimensional PCM heat exchanger model which discretizes the PCM tank and refrigerant tubes into small control volumes is developed. Each control volume can have different PCM temperatures, PCM properties, and heat transfer coefficients. The PCM tank is charged by a wrapped tank condenser and discharged by an internal refrigerant coil. The PCM heat exchanger model is integrated into DOE/ORNL Heat Pump Design Model for heat pump system simulation. To demonstrate the performance of the PCM integrated heat pump, a case study in Chicago was performed. A Time-of-Use utility structure-based control strategy is implemented to schedule the PCM tank charging and discharging mode switching. Compared with a conventional electric heat pump, the PCM integrated heat pump shows superior performance on load shifting and utility cost reduction. As a result, the proposed system demonstrates 24.6% utility saving for cooling application and 25.8% utility saving for heating application.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of a Modular, Crushed-Rock Thermal Energy Storage Pilot Design

The goal of this project, primarily funded by the U.S. Department of Energy, is to design a next-step pilot to advance near-term energy storage integrated with a fossil plant to provide a facility capable of being viable and effective in a market with growing penetration of variable renewable energy (VRE). Thermal energy storage (TES) represents an ideal technology for this purpose. The current effort will complete a feasibility study to prepare for the Phase II pre-front end engineering design (pre-FEED) for implementing a crushed-rock TES system integrated with a natural gas combined cycle (NGCC) plant. The crushed rock storage technology, which is being developed by Brenmiller Energy, is a modular TES system termed bGen™, which can accommodate both thermal and electrical inputs and output steam, hot water, or hot air. For this application, the estimated efficiency is 80% thermal to thermal. The TES technology is being designed to operate on a slipstream from NYPA’s Eugene W. Zeltmann Power Project (Zeltmann) natural gas combined cycle (NGCC) plant. The projected size of the system will be up to 4 MWe with at least 4 hours of storage duration, or 16 MWh-e total. Final sizing is being determined during the ongoing feasibility study. The next-step pilot being designed as part of the current project will represent a 5-fold increase in scale for this TES technology, and will be used to validate the technology’s ability to provide effective and economical energy storage. This pilot would represent the next-to-last demonstration scale before the technology could be commercial ready at GWh-e scales in the 2030 timeframe. This project is expected to design the critical next-step pilot, which will be undertaken in real-world operating conditions to better determine the crushed rock TES technology’s ability to be integrated with an NGCC plant and assess degradation over transient cycling at rates befitting various marketplaces. The crushed-rock TES pilot design is a technically feasible next step in the development of the technology and is built upon years of prior testing and demonstration. The proposed TES technology was developed by Brenmiller over the last 8 years and has been tested in 3 generations of demonstration units at various sites, globally. During this field testing, different characteristics and performance of the technology were validated, including the following key features: energy storage capacity, energy storage charge/discharge rate, energy storage loses, energy storage mechanical testing. This presentation will provide an update on the results of the conceptual design study for the modular crushed-rock TES system, integrated with a NGCC power plant.

03 NATURAL GAS↗