Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Enhanced Monte Carlo Simulations for Electron Energy Loss Mitigation in Real-Space Nanoimaging of Thick Biological Samples and Microchips

High-resolution imaging using Transmission Electron Microscopy (TEM) is essential for applications such as grain boundary analysis, microchip defect characterization, and biological imaging. However, TEM images are often compromised by electron energy spread and other factors. In TEM mode, where the objective and projector lenses are positioned downstream of the sample, electron–sample interactions cause energy loss, which adversely impacts image quality and resolution. This study introduces a simulation tool to estimate the electron energy loss spectrum (EELS) as a function of sample thickness, covering electron beam energies from 300 keV to 3 MeV. Leveraging recent advances in MeV-TEM/STEM technology, which includes a state-of-the-art electron source with 2-picometer emittance, an energy spread of 3 × 10 -5 , and optimized beam characteristics, we aim to minimize energy spread. By integrating EELS capabilities into the BNL Monte Carlo (MC) simulation code for thicker samples, we evaluate electron beam parameters to mitigate energy spread resulting from electron–sample interactions. Based on our simulations, we propose an experimental procedure for quantitively distinguishing between elastic and inelastic scattering. The findings will guide the selection of optimal beam settings, thereby enhancing resolution for nanoimaging of thick biological samples and microchips.

36 MATERIALS SCIENCE↗

Limitations of Thermal Stability Analysis via In-Situ TEM/Heating Experiments

This work highlights some limitations of thermal stability analysis via in-situ transmission electron microscopy (TEM)-annealing experiments on ultrafine and nanocrystalline materials. We provide two examples, one on nanocrystalline pure copper and one on nanocrystalline HT-9 steel, where in-situ TEM-annealing experiments are compared to bulk material annealing experiments. The in-situ TEM and bulk annealing experiments demonstrated different results on pure copper but similar output in the HT-9 steel. The work entails discussion of the results based on literature theoretical concepts, and expound on the inevitability of comparing in-situ TEM annealing experimental results to bulk annealing when used for material thermal stability assessment.

36 MATERIALS SCIENCE↗

Facile Tensile Testing Platform for In Situ Transmission Electron Microscopy of Nanomaterials

In situ tensile testing using transmission electron microscopy (TEM) is a powerful technique to probe structure-property relationships of materials at the atomic scale. In this work, a facile tensile testing platform for in situ characterization of materials inside a transmission electron microscope is demonstrated. The platform consists of: 1) a commercially available, flexible, electron-transparent substrate (e.g., TEM grid) integrated with a conventional tensile testing holder, and 2) a finite element simulation providing quantification of specimen-applied strain. The flexible substrate (carbon support film of the TEM grid) mitigates strain concentrations usually found in free-standing films and enables in situ straining experiments to be performed on materials that cannot undergo localized thinning or focused ion beam lift-out. The finite element simulation enables direct correlation of holder displacement with sample strain, providing upper and lower bounds of expected strain across the substrate. The tensile testing platform is validated for three disparate material systems: sputtered gold-palladium, few-layer transferred tungsten disulfide, and electrodeposited lithium, by measuring lattice strain from experimentally recorded electron diffraction data. The results show good agreement between experiment and simulation, providing confidence in the ability to transfer strain from holder to sample and relate TEM crystal structural observations with material mechanical properties.

2D materials↗

Atomic‐Resolution Imaging of Halide Perovskites Using Electron Microscopy

Abstract Atomic‐resolution imaging of halide perovskites (HPs) using transmission electron microscopy (TEM) is challenging because of the sensitivity of their structures to the electron beam. In this article, recent achievements in this area are reviewed, covering both all‐inorganic and organic–inorganic hybrid HPs, with an emphasis on the specific imaging conditions that have proven to be effective in avoiding electron beam‐induced structural damage. The discussion focusses on the total electron dose that HPs can bear before being damaged and the effects of different imaging modes, accelerating voltages, and temperatures. The crucial role of a direct‐detection electron‐counting camera in reducing the required electron dose is outlined, which is indispensable for imaging extremely sensitive organic–inorganic hybrid perovskites. In addition to reviewing published works, the results of initial attempts to perform atomic‐resolution elemental mapping for an all‐inorganic HP and image a hybrid HP using scanning TEM are introduced. The preparation of a TEM specimen from macroscopic crystals or devices of HPs, which is very important for practical applications but has not yet received attention, is also discussed. This article aims to provide guidance on the acquisition of atomic‐resolution TEM images of HPs and inspire the development of more imaging technologies for sensitive materials.

Song, Kepeng↗

Investigations of Polymethacrylate Tribochemical Films Using X-Ray Spectroscopy and Optical Profilometry

This study investigates the elemental composition and surface morphology of solid tribochemical films formed on steel surfaces. The reversible addition-fragmentation chain transfer (RAFT) method was used to synthesize nine different metal-free polymers, which were blended into commercial base oils. The polymers were either homopolymers of dodecyl methacrylate and ethylhexyl methacrylate or were co-polymers of these monomers with six polar monomers. After tribological testing at 100 degrees C using the ball-on-flat geometry, the resulting tribochemical films were imaged using scanning electron microscopy (SEM) and optical microscopy. The resulting tribochemical films have thicknesses around 50-100 nm. Two of the films corresponding to small (P1-imidazole-containing copolymer) and large (P3-less polar homopolymer) wear were cross-sectioned using focused ion beam (FIB) and analyzed for elemental composition using energy-dispersive X-Ray (EDX) mapping. Oxygen and nitrogen enrichment was observed, consistent with the relative chemical composition of the precursor polymers. Transmission electron microscopy (TEM) evidence suggests that at the worn surface, some organic elements penetrate or are mixed into the steel substrate giving an interlocking appearance. The two samples examined with TEM showed that P1 tribofilm is diffused or mixed with the steel substrate more so than P3, suggesting a stronger affinity and contact during tribofilm formation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Using Multiple Geophysical Methods to Refine a Stratigraphic Conceptual Site Model at a Nuclear Waste Site

At contaminated sites, there is a critical reliance on conceptual site models of which a key component is the geologic framework model (GFM), which is used to build predictive fate and transport modeling in support of remediation goals. Here, we detail an ongoing study at a nuclear waste site (Hanford Site, Washington, USA) where surface geophysical methods were used to complement existing borehole information and to help site new boreholes to update and refine the GFM. Ground-based electrical resistivity tomography (ERT), time-domain electromagnetics (TEM), and seismic data was acquired on the Hanford Site’s Central Plateau, where the presence of a hydraulically transmissive subsurface feature, or paleochannel, was suspected but uncertain based on contaminant concentrations at sparsely located boreholes. To assess and compare ERT, TEM, and seismic geophysical datasets, co-located data was acquired in an area where the existing GFM was more certain. Surrounding the suspected paleochannel, ERT and seismic refraction tomography showed similar subsurface structures consistent with a channelized feature. While TEM interpretation was limited in the suspected paleochannel area due to a thick resistive top layer and high electromagnetic noise, TEM showed greater utility in a different area where these factors were less prevalent. Based on the results of quasi-3D ERT inversions, we propose updates to the GFM, including identifying a paleochannel. Further, we evaluate the utility of geophysical methods and examine lessons learned that will be used as a basis for continued characterization efforts to support site management decisions and implementation efforts.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The subsurface structure of abraded Al–Zn–Mg–Cu alloy

Surface abrasion has been shown to introduce heavy shear stress and produce a few hundred nanometers thick altered surface layer (ASL) on Al alloys. Such ASLs exhibit microstructural changes at room temperature and different corrosion resistance than the underlying substrate. Here, we report how sample dimensions and temperature affect the deformed subsurface microstructure evolution on an abraded Al–Zn–Mg–Cu alloy using transmission electron microscopy (TEM) and atom probe tomography. The ASL microstructure evolves differently in the bulk sample than in the thin TEM specimen. In the freshly abraded ASL, the original η'/η precipitates and grain boundaries were deformed toward the abrasion direction. After 7-day natural aging of the freshly abraded bulk sample, well-defined subgrains formed locally in the ASL, and unusual Al 2 Cu (θ) and Mg x Zn y phases precipitated at the subgrain boundaries. However, during natural aging of this TEM specimen taken from the abraded and aged bulk samples, much faster changes occurred, including the continued formation of subgrains and θ particles in the entire ASL, and the diffusion of Zn atoms out of Mg x Zn y particles to form a Zn particle. On the other hand, no obvious microstructural changes occurred in the ASL during 3-month natural aging of the TEM specimen immediately taken from the freshly abraded sample. Finally, this work advances the understanding of how Al alloy microstructures respond during and following any shear deformation, and complex and unexpected effects of sample dimensions on the behavior.

36 MATERIALS SCIENCE↗

Ultra-Fast Electron Microscopic Imaging of Single Molecules With a Direct Electron Detection Camera and Noise Reduction

Time-resolved imaging of molecules and materials made of light elements is an emerging field of transmission electron microscopy (TEM), and the recent development of direct electron detection cameras, capable of taking as many as 1,600 fps, has potentially broadened the scope of the time-resolved TEM imaging in chemistry and nanotechnology. However, such a high frame rate reduces electron dose per frame, lowers the signal-to-noise ratio (SNR), and renders the molecular images practically invisible. Here, we examined image noise reduction to take the best advantage of fast cameras and concluded that the Chambolle total variation denoising algorithm is the method of choice, as illustrated for imaging of a molecule in the 1D hollow space of a carbon nanotube with ~1 ms time resolution. Through the systematic comparison of the performance of multiple denoising algorithms, we found that the Chambolle algorithm improves the SNR by more than an order of magnitude when applied to TEM images taken at a low electron dose as required for imaging at around 1,000 fps. Open-source code and a standalone application to apply Chambolle denoising to TEM images and video frames are available for download.

47 OTHER INSTRUMENTATION↗

Deep Learning Segmentation of Complex Features in Atomic-Resolution Phase-Contrast Transmission Electron Microscopy Images

Phase-contrast transmission electron microscopy (TEM) is a powerful tool for imaging the local atomic structure of materials. TEM has been used heavily in studies of defect structures of two-dimensional materials such as monolayer graphene due to its high dose efficiency. However, phase-contrast imaging can produce complex nonlinear contrast, even for weakly scattering samples. It is, therefore, difficult to develop fully automated analysis routines for phase-contrast TEM studies using conventional image processing tools. For automated analysis of large sample regions of graphene, one of the key problems is segmentation between the structure of interest and unwanted structures such as surface contaminant layers. In this study, we compare the performance of a conventional Bragg filtering method with a deep learning routine based on the U-Net architecture. We show that the deep learning method is more general, simpler to apply in practice, and produces more accurate and robust results than the conventional algorithm. We provide easily adaptable source code for all results in this paper and discuss potential applications for deep learning in fully automated TEM image analysis.

47 OTHER INSTRUMENTATION↗

Shape Dependence of Pressure-Induced Phase Transition in CdS Semiconductor Nanocrystals

Understanding structural stability and phase transformation of nanoparticles under high pressure is of great scientific interest, as it is one of the crucial factors for design, synthesis, and application of materials. Even though high-pressure research on nanomaterials has been widely conducted, their shape-dependent phase transition behavior still remains unclear. Examples of phase transitions of CdS nanoparticles are very limited, despite the fact that it is one of the most studied wide band gap semiconductors. Here we have employed in-situ synchrotron wide-angle X-ray scattering (WAXS) and transmission electron microscopy (TEM) to investigate the high-pressure behaviors of CdS nanoparticles as a function of particle shapes. We observed that CdS nanoparticles transform from wurtzite to rocksalt phase at elevated pressure in comparison to their bulk counterpart. Phase transitions also vary with particle shape—rod-shaped particles show a partially reversible phase transition and the onset of the structural phase transition pressure decreases with decreasing surface-to-volume ratios, while spherical particles undergo irreversible phase transition with relatively low phase transition pressure. Additionally, TEM images of spherical particles exhibited sintering-induced morphology change after high-pressure compression. Calculations of the bulk modulus reveals that spheres are more compressible than rods in the wurtzite phase. These results indicate that the shape of the particle plays an important role in determining their high-pressure properties. Our study provides important insights into understanding of the phase-structure-property relationship, guiding future design and synthesis of nanoparticles for promising applications.

36 MATERIALS SCIENCE↗

Insights into the Structure and Dynamics of Metal–Organic Frameworks via Transmission Electron Microscopy

Metal–organic frameworks (MOFs) are hybrid materials composed of metal ions and organic linkers featuring high porosity, crystallinity, and chemical tunability at multiple length scales. Here, a recent advancement in transmission electron microscopy (TEM) and its direct application to MOF structure–property relationships have changed how we consider rational MOF design and development. Herein, we provide a perspective on TEM studies of MOFs and highlight the utilization of state-of-the-art TEM technologies to explore dynamic MOF processes and host–guest interactions. Additionally, we provide thoughts on what the future holds for TEM in the study of MOFs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Elucidating the Role of Halides and Iron during Radiolysis-Driven Oxidative Etching of Gold Nanocrystals Using Liquid Cell Transmission Electron Microscopy and Pulse Radiolysis

Graphene liquid cell transmission electron microscopy (TEM) has enabled the observation of a variety of nanoscale transformations. Yet understanding the chemistry of the liquid cell solution and its impact on the observed transformations remains an important step toward translating insights from liquid cell TEM to benchtop chemistry. Gold nanocrystal etching can be used as a model system to probe the reactivity of the solution. FeCl 3 has been widely used to promote gold oxidation in bulk and liquid cell TEM studies, but the roles of the halide and iron species have not been fully elucidated. In this work, we observed the etching trajectories of gold nanocrystals in different iron halide solutions. We observed an increase in gold nanocrystal etch rate going from Cl - - to Br - - to I - -containing solutions. Furthermore, this is consistent with a mechanism in which the dominant role of halides is as complexation agents for oxidized gold species. Additionally, the mechanism through which FeCl 3 induces etching in liquid cell TEM remains unclear. Ground-state bleaching of the Fe(III) absorption band observed through pulse radiolysis indicates that iron may react with Cl 2 · - radicals to form an oxidized transient species under irradiation. Complete active space self-consistent field (CASSCF) calculations indicate that the FeCl 3 complex is oxidized to an Fe species with an OH radical ligand. Together our data indicate that an oxidized Fe species may be the active oxidant, while halides modulate the etch rate by tuning the reduction potential of gold nanocrystals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Charges on a suspended silicon nitride membrane under a high-energy electron beam

Thin silicon nitride (SiN x ) membranes are widely used in gas and liquid phase transmission electron microscopy (TEM) and as phase plates to enhance imaging contrast. SiN x contains trap sites for both positive and negative charges, which can be manipulated by high-energy electron irradiation, external potential biasing, or light exposure. Charge accumulation on the membrane can significantly affect in situ TEM processes, including chemical and electrochemical reactions, nanoparticle dynamics, and catalytic activity, or introduce unwanted phase shifts when used as a phase plate. Here, in this study, charge accumulation on suspended SiN x membranes was investigated using off-axis electron holography combined with model-free charge analysis, supported by custom finite element analysis (FEA) simulations. An average residual positive charge density of approximately 2.8 × 10 −4 C m −2 was measured. Localized and stable regions of both positive and negative charges were identified on the membrane. The global positive and localized positive/negative charges give rise to strong electric fields and electroosmotic slip velocities at the membrane surface, which are sufficient to induce non-Brownian particle behavior and directional fluid flow, offering a physical explanation for previously observed anomalies in particle dynamics, nucleation, and growth during gas and liquid phase TEM experiments. These results provide a benchmark for understanding charge behavior at SiNx interfaces in gas and liquid phase TEM. Furthermore, the FEA simulations establish a framework for future investigations into charge distribution, electrostatic potentials, and electrical double layers at solid–liquid interfaces, particularly in complex geometries and chemically dynamic environments.

Suspended silicon↗

Deformation of Néel-type skyrmions revealed by Lorentz transmission electron microscopy

Néel-type magnetic skyrmions in multilayers are promising candidates for ultra-low power spintronic devices. To image the Néel-type skyrmions using Lorentz transmission electron microscopy (L-TEM), the samples must be tilted. Thus, the external magnetic field consists of both in-plane and out-of-plane components. To date, it is still not well known on the effect of the in-plane magnetic field on the L-TEM images, leading to ambiguities in retrieving the structure of Néel-type skyrmions. Here, Néel-type skyrmions in three [Pt/Co/Ta]$_{20}$ multilayer samples, with the easy magnetization axis being tuned from the out-of-plane to the in-plane direction by increasing the Co thickness from 1.8 to 2.2 nm, are imaged. When using a smaller defocus value (-2 mm) and a higher magnification (×9100) of L-TEM, a surprising dark-bright-dark-bright double contrasted pattern, instead of the previously reported dark-bright contrasted pattern, is observed. The additional dark-bright contrasted pattern becomes more evident for thicker Co layer samples in which the magnetization axis tilts more toward the in-plane direction. Further analysis, via a combination of magnetic force microscopy experiments, micromagnetic simulations, and micromagnetic analysis to Lorentz TEM simulation, shows that the additional dark-bright features originate from the deformation of the Néel-type skyrmions within an in-plane magnetic field.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of fluorite-structured ferroelectrics using transmission electron microscopy: Techniques, challenges, and recent advances

Fluorite-structured ferroelectrics, such as hafnium oxide and its alloyed variants, are key candidates for next-generation memory devices. Yet, fundamental questions about switching mechanisms, domain dynamics, and phase evolution remain open. Transmission electron microscopy (TEM) provides unique capabilities to address these challenges by simultaneously resolving the positions of anions and cations, chemical variations, and structural transformations. Recent advances—including in situ heating, electron beam-induced switching, electron energy loss spectroscopy, and differential phase contrast imaging—have revealed critical insights into phase transitions, potential switching pathways, and oxygen vacancy behavior. However, experimental barriers such as TEM sample-preparation-induced artifacts, high coercive fields, and imaging constraints persist, especially for polycrystalline films. By offering a focused overview of current TEM developments in fluorite ferroelectrics, this work outlines how TEM contributes to understanding key phenomena and proposes a roadmap for future studies.

36 MATERIALS SCIENCE↗

Gyrokinetic simulations of core turbulence and thermal transport in the high-β P discharge on EAST

The properties of core turbulence and thermal transport are investigated for EAST high-β P (β P ~ 3.1) plasmas with dominant electron heating (Te/Ti > 1) via gyrokinetic simulation with the NLT code. Linear simulations identify that the electrostatic η e -driven trapped electron mode (η e -TEM) dominates in the core region (ρ< 0.7) and the ion temperature gradient (ITG) mode dominates in the out region (ρ≥ 0.7), consistent with the linear threshold analysis of micro-instabilities. Sensitivity analysis shows that the normalized electron density gradient (R/L ne ) and ITG (R/L Ti ) are two effective parameters to stabilize TEM instability. Nonlinear simulations are also carried out and compared with the experimental results, which show that the electron thermal internal transport barrier (ITB) in EAST high-β P plasma is determined by the TEM-induced turbulence. A higher zonal flow shearing rate is observed in the ITB region (0.2 < ρ < 0.34), which can regulate energy transport induced by TEM turbulence and facilitate the formation of e-ITB. A plausible positive feedback mechanism to mitigate turbulence transport and improve energy confinement via enhanced ion heating is proposed for future experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

New understanding of inter-ELM pedestal turbulence, transport, and gradient behavior in the DIII-D tokamak

New observations of pedestal localized turbulence in the inter-ELM period of H-mode plasmas in DIII-D show that ion temperature gradient mode scale (ITG-scale) density fluctuation (ñ) increases immediately after each ELM crash and is quickly suppressed during the increase in local E × B shear. This excitation and subsequent suppression of ITG-scale ñ can explain the previously reported anomalous ion heat flux, Qi during the ELM (Viezzer et al 2017 Nucl. Fusion 57 022020). Shorter wavelength trapped electron mode scale (TEM-scale) ñ starts to increase at a critical pedestal temperature gradient (∇Te,ped) and saturates as local E × B shear, ${T}_{\mathrm{i}}^{\mathrm{C}\mathrm{6}+}/{T}_{\mathrm{e}}$ ratio, and ∇Te,ped saturate. This TEM-scale ñ, which has the potential to cause electron (and also ion) heat transport, is consistent with driving an anomalous electron heat flux Qe, where Qe is estimated between ELMs using experimental profiles and power balance. Both ITG- and TEM-scale ñ amplitude variations with background Ti/Te and ∇ne,ped are found to be consistent with theoretical predictions of these measured density fluctuations being ITG and TEM instabilities respectively. Furthermore, these new and unique observations on the nature of turbulence and their potential contributions to electron and ion heat fluxes at different ELM periods (i.e. collapse, recovery, and saturation phases of pedestal gradients) can significantly test and improve our pedestal predictive capabilities for ITER and other future fusion devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Scanning Transmission Electron Microscopy–Atom Probe Tomography Correlative Analysis for the Characterization of Solute-defect Interactions

Atom probe tomography (APT) and (scanning) transmission electron microscopy ((S)TEM) are complementary techniques that provide spatially resolved chemical and structural information at the atomic scale. Here, in this study, we employ two different STEM/APT correlative analysis methods to investigate Cr segregation at dislocation loops in ultra-high purity Fe–Cr alloys. APT needles for the correlative analysis were extracted either from bulk material or from thinned TEM lamellae. STEM analysis was used to determine the Burgers vectors of ion-irradiation-induced dislocation loops, while APT reconstruction of the same region revealed the Cr segregation to these loops. We extended the g•b = 0 invisibility criterion of dislocation loops from TEM mode in a lamella to STEM mode in a needle-shaped specimen. STEM and APT analysis on the same needle provide straightforward correlative analysis, although it is limited by a small observation volume. In contrast, iterative STEM analysis of TEM lamellae, followed by the selective extraction of specific regions of interest for APT analysis, expands the observation area by up to 100 times but requires additional time-consuming steps for APT needle extraction from the lamellae.

47 OTHER INSTRUMENTATION↗