Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Superconducting RF”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

FERMILAB CRYOMODULE TEST STAND RF INTERLOCK SYSTEM

An interlock system has been designed for the Fermilab Cryo-module Test Stand (CMTS), a test bed for the cryo- modules to be used in the upcoming Linac Coherent Light Source 2 (LCLS-II) project at SLAC. The interlock system features 8 independent subsystems, one per superconducting RF cavity and solid state amplifier (SSA) pair. Each system monitors several devices to detect fault conditions such as arcing in the waveguides or quenching of the SRF system. Additionally each system can detect fault conditions by monitoring the RF power seen at the cavity coupler through a directional coupler. In the event of a fault condition, each system is capable of removing RF signal to the amplifier (via a fast RF switch) as well as turning off the SSA. Additionally, each input signal is available for re- mote viewing and recording via a Fermilab designed digitizer board and MVME 5500 processor.

43 PARTICLE ACCELERATORS↗

Nb3Sn SRF Cavities for Nuclear Physics Applications

Nuclear physics experiments rely increasingly on accelerators, which employ superconducting RF (SRF) technology. CEBAF, SNS, FRIB, ESS, among others exploit the low surface resistance of SRF cavities to efficiently accelerate particle beams towards experimental targets. Niobium is the cavity material of choice for all current or planned SRF accelerators, but it has been long recognized that other superconductors with high superconducting transition temperatures have the potential to surpass niobium for SRF applications. Among the alternatives, Nb3Sn coated cavities are the most advanced on the path to practical applications: Nb3Sn coatings on R&D cavities have Tc consistently close the optimal 18 K, very low RF surface resistances, and very recently were shown to reach above Hc1 without anomalous RF surface resistance increase. In my talk I will discuss the prospects of Nb3Sn SRF cavities and the research efforts to realize Nb3Sn coatings on practical multi-cell accelerating structures.

Eremeev, Grigory↗

Advances in Multi-Physics Modeling for Parallel Finite Element Code Suite ACE3P

SLAC developed ACE3P code suite is a comprehensive set of parallel finite-element codes for multi-physics modeling of particle accelerators. Running on massively parallel computer platforms for high fidelity and high accuracy simulation, ACE3P enables rapid virtual prototyping of accelerator and RF component design, optimization and analysis. Furthermore, recent advances of ACE3P have been focused on the implementation of advanced numerical algorithms, enhancement of multi-physics capabilities, and improvement of code performance on state-of-the-art high performance computing (HPC) platforms for large-scale RF modeling in accelerator applications and beyond. In this paper, we will present a nonlinear electromagnetic (EM) eigensolver for damping calculation of resonant modes for cavities coupled with waveguides, the thermal solver for accurate evaluation of heat loads in superconducting RF (SRF) cavity power coupler, the elastic solver for investigation of SRF cavity cryomodule (CM) bowing due to thermal effect, the frequency domain mechanical solver for studying SRF cavity mechanical oscillation modes, the particle tracking code for dark current simulation in SRF CM using a hybrid MPI+OpenMP parallel programing model, the time domain solver for high fidelity modeling of EM wave propagation for medical device in human body.

97 MATHEMATICS AND COMPUTING↗

Final Technical Report on STTR Project DE-FG02-04ER86191 Hydrogen Cryostat for Muon Beam Cooling

The project was to develop cryostat designs that could be used for muon beam cooling channels where hydrogen would circulate through refrigerators and the beam-cooling channel to simultaneously refrigerate 1) high-temperature-superconductor (HTS) magnet coils, 2) cold copper RF cavities, and 3) the hydrogen that is heated by the muon beam. In an application where a large amount of hydrogen is naturally present because it is the optimum ionization cooling material, it was reasonable to explore its use with HTS magnets and cold, but not superconducting, RF cavities. In this project we developed computer programs for simulations and analysis and conducted experimental programs to examine the parameters and technological limitations of the materials and designs of Helical Cooling Channel (HCC) components (magnet conductor, RF cavities, absorber windows, heat transport, energy absorber, and refrigerant).The project showed that although a hydrogen cryostat is not the optimum solution for muon ionization cooling channels, the studies of the cooling channel components that define the cryostat requirements led to fundamental advances. In particular, two new lines of promising development were opened up, regarding very high field HTS magnets and the HS concept, that have led to new proposals and funded projects.

43 PARTICLE ACCELERATORS↗

Benchmark of Different Electromagnetic Codes for the High Frequency Calculation

In this paper, we present benchmarking results for highclass 3D electromagnetic (EM) codes in designing RF cavities today. These codes include Omega3P [1], VORPAL [2], CST Microwave Studio [3], Ansoft HFSS [4], and ANSYS [5]. Two spherical cavities are selected as the benchmark models. We have compared not only the accuracy of resonant frequencies, but also that of surface EM fields, which are critical for superconducting RF cavities. By removing degenerated modes, we calculate all the resonant modes up to 10 GHz with similar mesh densities, so that the geometry approximation and field interpolation error related to the wavelength can be observed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Beam-Dynamics Analysis of Long-Range Wakefield Effects on the SCRF Cavities at the Fast Facility

Long-range wakefields in superconducting RF (SCRF) cavities create complicated effects on beam dynamics in SCRF-based FEL beamlines. The driving bunch excites effectively an infinite number of structure modes (including HOMs) which oscillate within the SCRF cavity. Couplers with loads are used to damp the HOMs. However, these HOMs can persist for long periods of time in superconducting structures, which leads to long-range wakefields. Clear understanding of the long-range wakefield effects is a critical element for risk mitigation of future SCRF accelerators such as XFEL at DESY, LCLS-II XFEL, and MaRIE XFEL. We are currently developing numerical tools for simulating long-range wakefields in SCRF accelerators and plan to experimentally verify the tools by measuring these wakefields at the Fermilab Accelerator Science and Technology (FAST) facility. This paper previews the experimental conditions at the FAST 50 MeV beamline based on the simulation results.

43 PARTICLE ACCELERATORS↗

Higher-order-mode absorbers for energy recovery linac cryomodules at Brookhaven National Laboratory

Several future accelerator projects at Brookhaven for the Relativistic Heavy Ion Collider (RHIC) are based on energy recovery linacs (ERLs) with high-charge high-current electron beams. Their stable operation mandates effective higher-order-mode (HOM) damping. The development of HOM dampers for these projects is pursued actively at this laboratory. Strong HOM damping was experimentally demonstrated both at room and at superconducting (SC) temperatures in a prototype research and development (R&D) five-cell niobium superconducting rf (SRF) cavity with ferrite dampers. Two room-temperature mock-up five-cell copper cavities were used to study various damper configurations with emphasis on capacitive antenna dampers. An innovative type of ferrite damper over a ceramic break for an R&D SRF electron gun also was developed. For future SRF linacs longer cryomodules comprised of multiple superconducting cavities with reasonably short intercavity transitions are planned. In such a configuration, the dampers, located closer to the cavities, will be at cryogenic temperatures; this will impose additional constraints and complications. This paper presents the results of simulations and measurements of several damper configurations.

43 PARTICLE ACCELERATORS↗

Coupled Bunch Instability from JLEIC Crab Cavity Higher Order Modes

Particle bunches traveling in a ring can excite wakefields inside any radio-frequency (rf) element present. These electromagnetic modes can resonate long enough and interact with subsequent passing bunches. A coherent oscillation between bunches can quickly become an instability and needs to be addressed. The Jefferson Lab Electron-Ion Collider (JLEIC) has a large 50 mrad crossing angle and thus relies on bunch crabbing to achieve high luminosity. Bunch crabbing is done with compact superconducting rf dipole cavities. We study coupled bunch oscillations driven by the higher order modes (HOM) of multi-cell rf dipole (rfd) crab cavities under study for JLEIC, we calculate the instability growth time assuming a symmetric beam frequency spectrum, identify the HOM driving the instability and discuss mitigation measures.

Sosa Guitron, Salvador I.↗

A YBCO RF-SQUID magnetometer and its applications

An applicable RF-superconducting quantum interference detector (SQUID) magnetometer was made using a bulk sintered yttrium barium copper oxide (YBCO). The temperature range of the magnetometer is 77 to 300 K and the field range 0 to 0.1T. At 77 K, the equivalent flux noise of the SQUID is 5 x 10 to minus 4 power theta sub o/square root of Hz at the frequency range of 20 to 200 Hz. The experiments show that the SQUID noise at low-frequency end is mainly from 1/f noise. A coil test shows that the magnetic moment sensitivity delta m is 10 to the minus 6th power emu. The RF-SQUID is shielded in a YBCO cylinder with a shielding ability B sub in/B sub ex of about 10 to the minus 6th power when external dc magnetic field is about a few Oe. The magnetometer is successfully used in characterizing superconducting thin films.

Luwei, Zhou↗

Beam dynamics simulations of the NML photoinjector at Fermilab

Fermilab is currently constructing a superconducting RF (SRF) test linear accelerator at the New Muon Lab (NML). Besides testing SRF accelerating modules for ILC and Project-X, NML will also eventually support a variety of advanced accelerator R&D experiments. The NML incorporates a 40 MeV photoinjector capable of providing electron bunches with variable parameters. The photoinjector is based on the 1+1/2 cell DESY-type gun followed by two superconducting cavities. It also includes a magnetic bunch compressor, a round-to-flat beam transformer and a low-energy experimental area for beam physics experiments and beam diagnostics R&D. In this paper, we explore, via beam dynamics simulations, the performance of the photoinjector for different operating scenarios.

43 PARTICLE ACCELERATORS↗

A Wire Position Monitor System for the 1.3 FHZ Tesla-Style Cryomodule at the Fermilab New-Muon-Lab Accelerator

The first cryomodule for the beam test facility at the Fermilab New-Muon-Lab building is currently under RF commissioning. Among other diagnostics systems, the transverse position of the helium gas return pipe with the connected 1.3 GHz SRF accelerating cavities is measured along the {approx}15 m long module using a stretched-wire position monitoring system. An overview of the wire position monitor system technology is given, along with preliminary results taken at the initial module cooldown, and during further testing. As the measurement system offers a high resolution, we also discuss options for use as a vibration detector. An electron beam test facility, based on superconducting RF (SRF) TESLA-style cryomodules is currently under construction at the Fermilab New-Muon-Lab (NML) building. The first, so-called type III+, cryomodule (CM-1), equipped with eight 1.3 GHz nine-cell accelerating cavities was recently cooled down to 2 K, and is currently under RF conditioning. The transverse alignment of the cavity string within the cryomodule is crucial for minimizing transverse kick and beam break-up effects, generated by the high-order dipole modes of misaligned accelerating structures. An optimum alignment can only be guaranteed during the assembly of the cavity string, i.e. at room temperatures. The final position of the cavities after cooldown is uncontrollable, and therefore unknown. A wire position monitoring system (WPM) can help to understand the transverse motion of the cavities during cooldown, their final location and the long term position stability after cryo-temperatures are settled, as well as the position reproducibility for several cold-warm cycles. It also may serve as vibration sensor, as the wire acts as a high-Q resonant detector for mechanical vibrations in the low-audio frequency range. The WPM system consists out of a stretched-wire position detection system, provided with help of INFN-Milano and DESY Hamburg, and RF generation and read-out electronics, developed at Fermilab.

43 PARTICLE ACCELERATORS↗

High resolution and fast scanning squid based non-destructive inspection system of niobium sheets for SRF cavities

Applications in high energy physics accelerators and other fields require the use of thousands of superconducting RF (SRF) cavities that are made of high purity Nb material and the purity of niobium is critical for these cavities to reach the highest accelerating fields. Tantalum is the most prolific of metal inclusions, which can cause thermal breakdown and prevent the cavities from reaching their theoretical performance limits of 45-50 MV/m, and DOE Labs are searching for a technology that could detect small impurities in superconducting Nb sheets reaching the highest possible accelerating fields. The proposed innovative SQUID-based Nondestructive system can scan Niobium sheets used in the manufacturing of SRF cavities with both high speed and high resolution. A highly sensitive SQUID system with a gradiometer probe, non-magnetic dewar, data acquisition system, and a scanning system will be developed for fast detection of impurities in planar Nb sheets. In phase I, we will modify our existing SQUID-based eddy current system to detect 100 micron size Ta defects and a great effort will focus on achieving fast scanning of a large number of niobium sheets in a shorter time and with reasonable resolution. An older system operated by moving the sample 1 mm, stopping and waiting for 1-2 seconds, then activating a measurement by the SQUID after the short settle time is modified. A preliminary designed and implemented a SQUID scanning system that is fast and is capable of scanning a 30 cm x 30 cm Nb sheet in 15 minutes by continuously moving the table at speeds up to 10 mm/s while activating the SQUID at 1mm interval is modified and reached the Phase I goal of 100mm resolution. We have successfully demonstrated the feasibility that a fast speed SQUID scanner without sacrificing the resolution of detection can be done, and a data acquisition and analysis system is also preliminary developed. The SQUID based scanner will help reach the highest accelerating field in SRF cavities that will provide a considerable cost reduction for new accelerators and for upgrades of existing accelerators. This will be realized either by reducing the length required for the SRF cavities or by the installation of higher gradient cavities for energy upgrades in the same space. The SQUID based scanner will also be used for the detection of defects on the surface, inside the bulk or at the back side of metallic sheets in other industries.

43 PARTICLE ACCELERATORS↗

Design Construction and Test Results of a HTS Solenoid For Energy Recovery Linac

An innovative feature of the proposed Energy Recovery Linac (ERL) is the use of a solenoid made with High Temperature Superconductor (HTS) with the Superconducting RF cavity. The use of HTS allows solenoid to be placed in close proximity to the cavity and thus provides early focusing of the electron beam. In addition, cryogenic testing at {approx}77 K is simpler and cheaper than 4 K testing. This paper will present the design, construction and test results of this HTS solenoid. The HTS solenoid in the proposed ERL will be situated in the transition region between the superconducting cavity at {approx}4 K and the cryostat at the room temperature. Solenoid inside the cryogenic structure provides an early focusing and hence low emittance beam. The temperature in the transition region will be too high for a conventional low temperature superconductor and resistive heat load from copper coils will be too high on cryogenic system. HTS coils also allow much higher current density and significant reduction in size as compared to copper coils. Hence HTS solenoid provide a unique and technically superior solution. The use of a HTS solenoid with superconducting cavity offers a unique option as it can be placed in a cold to warm transition region to provide early focussing without using additional space. Construction and test results so far are very encouraging for its use in the ERL project.

43 PARTICLE ACCELERATORS↗

Exploring the effect of Al2O3 ALD coating on a high gradient ILC single-cell cavity

Encouraged by work at Argonne National Lab, we investigated atomic layer deposition technique (ALD) for high gradient superconducting RF cavities at JLab with an ALD coating system of Old Dominion University located on the JLab site. The goal of this study was to look into the possibility of coating a dielectric layer on top of RF niobium surface at a lower temperature of 120 C as compared to ANL coatings at 200 C to preserve niobium pentoxide on niobium surface. The initial coatings showed complete, but non-uniform coatings of the surface with several areas exhibiting discoloration, which was probably due to the temperature variation across the cavity surface. The initial coating showed a high RF losses, which were improved after discolored areas on the beam tubes were removed with HF rinse of the beam tubes only. The best result was 2 109 low field Q0 and Eacc = 18 MV/m limited by available power.

36 MATERIALS SCIENCE↗

Status and Plans for an SRF Accelerator Test Facility at Fermilab

A superconducting RF accelerator test facility is currently under construction at Fermilab. The accelerator will consist of an electron gun, 40 MeV injector, beam acceleration section consisting of 3 TTF-type or ILC-type cryomodules, and multiple downstream beam lines for testing diagnostics and performing beam experiments. With 3 cryomodules installed this facility will initially be capable of generating an 810 MeV electron beam with ILC beam intensity. The facility can accommodate up to 6 cryomodules for a total beam energy of 1.5 GeV. This facility will be used to test SRF cryomodules under high intensity beam conditions, RF power equipment, instrumentation, and LLRF and controls systems for future SRF accelerators such as the ILC and Project-X. This paper describes the current status and overall plans for this facility.

43 PARTICLE ACCELERATORS↗

Higher order model power calculation of the 56 MHz SRF cavity

A 56 MHz superconducting RF cavity (SRF) is going to be installed in Relativistic Heavy Ion Collider (RHIC) ring for the luminosity upgrade of the RHIC operation. Currently, it is being designed and prototype-tested as an Accelerator Improvement Project (AIP). The 56 MHz SRF cavity will be turned on at store of the RHIC operation. When the beam frequencies overlap or come close to the cavity HOM frequencies, the HOMs are excited in the cavity, which may lead to beam instability. Since the shunt impedance of the superconducting cavity tends to be higher than that of the copper cavity, the voltage developed in the cavity due to the HOM excitation can in principle be large. Therefore, suppressing the HOMs is an important task for the 56 MHz SRF cavity. To pursue the task, understanding the frequencies, Q factors and shunt impedances for the HOMs is prerequisite. Based on the given HOM characteristic, the HOM power can be calculated. The simulation results from the available programs as well as the prototype measurement results are used for the analysis.

43 PARTICLE ACCELERATORS↗

Absorber Materials at Room and Cryogenic Temperatures

We recently reported on investigations of RF absorber materials at cryogenic temperatures conducted at Jefferson Laboratory (JLab). The work was initiated to find a replacement material for the 2 Kelvin low power waveguide Higher Order Mode (HOM) absorbers employed within the original cavity cryomodules of the Continuous Electron Beam Accelerator Facility (CEBAF). This effort eventually led to suitable candidates as reported in this paper. Furthermore, though constrained by small funds for labor and resources, we have analyzed a variety of lossy ceramic materials, several of which could be usable as HOM absorbers for both normal conducting and superconducting RF structures, e.g. as loads in cavity waveguides and beam tubes either at room or cryogenic temperatures and, depending on cooling measures, low to high operational power levels.

43 PARTICLE ACCELERATORS↗

HiPIMS: a New Generation of Film Deposition Techniques for SRF Applications

Over the years, Nb/Cu technology, despite its shortcomings due to the commonly used magnetron sputtering, has positioned itself as an alternative route for the future of accelerator superconducting structures. Avenues for the production of thin films tailored for Superconducting RF (SRF) applications are showing promise with recent developments in ionized PVD coating techniques, i.e. vacuum deposition techniques using energetic ions. Among these techniques, High power impulse magnetron sputtering (HiPIMS) is a promising emerging technique which combines magnetron sputtering with a pulsed power approach. This contribution describes the benefits of energetic condensation for SRF films and the characteristics of the HiPIMS technology. It describes the on-going efforts pursued in different institutions to exploit the potential of this technology to produce bulk-like Nb films and go beyond Nb performance with the development of film systems, based on other superconducting materials and multilayer structures.

Valente-Feliciano, Anne-Marie↗