Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Storage ring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Search for e + e − → φ χ c 0 and φ η c 2 ( 1 D ) at center-of-mass energies from 4.47 to 4.95 GeV

Utilizing a dataset of 6.7 fb − 1 from electron-positron collisions recorded by the BESIII detector at the BEPCII storage ring, a search is conducted for the processes e + e − → ϕ χ c 0 and ϕ η c 2 ( 1 D ) across center-of-mass energies from 4.47 to 4.95 GeV. In the absence of any significant signals, upper limits are set. These include limits on the dressed cross sections for e + e − → ϕ χ c 0 , as well as the product of the dressed cross section for e + e − → ϕ η c 2 ( 1 D ) and a sum of five branching fractions. Furthermore, the product of the electronic width of Y ( 4660 ) and the branching fraction of the Y ( 4660 ) → ϕ χ c 0 , denoted as Γ e + e − Y ( 4660 ) B Y ( 4660 ) → ϕ χ c 0 , is determined to be < 0.35 eV at the 90% confidence level. Published by the American Physical Society 2025

Ablikim, M.↗

Measurement of the inclusive cross sections of prompt J / ψ and ψ ( 3686 ) production in e + e − annihilation from s = 3.808 to 4.951 GeV

The inclusive cross sections of prompt J / ψ and ψ ( 3686 ) production are measured at center-of-mass energies from 3.808 to 4.951 GeV. The dataset used is 22 fb − 1 of e + e − annihilation data collected with the BESIII detector operating at the BEPCII storage ring. The results obtained are in agreement with the previous BESIII measurements of exclusive J / ψ and ψ ( 3686 ) production. The average values obtained for the cross sections measured in the center-of-mass energy ranges from 4.527 to 4.951 GeV for J / ψ and from 4.843 to 4.951 GeV for ψ ( 3686 ) , where the impact of known resonances is negligible, are 14.0 ± 1.7 ± 3.1 pb and 15.3 ± 3.0 pb , respectively. For J / ψ , the first and the second uncertainties are statistical and systematic, respectively. For ψ ( 3686 ) , the uncertainty is total. These values are useful for testing charmonium production models. Published by the American Physical Society 2025

Ablikim, M.↗

𝑇-invariance violation in neutrino oscillations and matter effects

We investigate the impact of matter effects on 𝑇 (time-reversal)-odd observables, making use of the quantum-mechanical formalism of neutrino-flavor evolution. We attempt to be comprehensive and pedagogical. Matter-induced 𝑇-invariance violation (TV) is qualitatively different from, and more subtle than, matter-induced 𝐶⁢𝑃 (charge-parity)-invariance violation. If the matter distribution is symmetric relative to the neutrino production and detection points, matter effects will not introduce any new TV. However, if there is intrinsic TV, matter effects can modify the size of the 𝑇-odd observable. On the other hand, if the matter distribution is not symmetric, there is genuine matter-induced TV. For Earth-bound long-baseline oscillation experiments, these effects are small. This remains true for unrealistically-asymmetric matter potentials (for example, we investigate the effects of “hollowing out” 50% of the DUNE neutrino trajectory). More broadly, we explore consequences, or lack thereof, of asymmetric matter potentials on oscillation probabilities. While fascinating in their own right, 𝑇-odd observables are currently of limited practical use, due in no small part to a dearth of intense, well-characterized, high-energy electron-neutrino beams. Further in the future, however, intense, high-energy muon storage rings might become available and allow for realistic studies of 𝑇-invariance in neutrino oscillations.

CP violation↗

Dissociative Recombination of Cold HeH + Ions

The HeH + cation is the simplest molecular prototype of the indirect dissociative recombination (DR) process that proceeds through electron capture into Rydberg states of the corresponding neutral molecule. This Letter develops the first application of our recently developed energy-dependent frame transformation theory to the indirect DR processes. The theoretical model is based on the multichannel quantum-defect theory with the vibrational basis states computed using exterior complex scaling of the nuclear Hamiltonian. The ab initio electronic R-matrix theory is adopted to compute quantum defects as functions of the collision energy and of the internuclear distance. The resulting DR rates are convolved over the beam energy distributions relevant to a recent experiment at the Cryogenic Storage Ring, giving good agreement between the experiment and the theory.

74 ATOMIC AND MOLECULAR PHYSICS↗

Observation of Structures in the Processes e + e − → ω χ c 1 and ω χ c 2

We present measurements of the Born cross sections for the processes e + e − → ω χ c 1 and ω χ c 2 at center-of-mass energies s from 4.308 to 4.951 GeV. The measurements are performed with data samples corresponding to an integrated luminosity of 11.0 fb − 1 collected with the BESIII detector operating at the Beijing Electron Positron Collider storage ring. Assuming the e + e − → ω χ c 2 signals come from a single resonance, the mass and width are determined to be M = ( 4413.6 ± 9.0 ± 0.8 ) MeV / c 2 and Γ = ( 110.5 ± 15.0 ± 2.9 ) MeV , respectively, which is consistent with the parameters of the well-established resonance ψ ( 4415 ) . In addition, we also use one single resonance to describe the e + e − → ω χ c 1 line shape and determine the mass and width to be M = ( 4544.2 ± 18.7 ± 1.7 ) MeV / c 2 and Γ = ( 116.1 ± 33.5 ± 1.7 ) MeV , respectively. The structure of this line shape, observed for the first time, requires further understanding. Published by the American Physical Society 2024

Physics↗

Experimental Demonstration of a Large Transverse Emittance Ratio 11 : 1 in the Relativistic Heavy Ion Collider for the Electron-Ion Collider

The Electron-Ion Collider (EIC), to be constructed at Brookhaven National Laboratory, will collide polarized high-energy electron beams with hadron beams, achieving luminosities of up to 1.0 × 10 34 cm –2 s –1 in the center-of-mass energy range of 20–140 GeV. In order to achieve such high luminosity, the EIC will employ small and flat beams at the interaction point. In the hadron storage ring of the EIC, the ratio of horizontal to vertical emittances is approximately 11:1. In contrast, in previous or existing hadron colliders, the horizontal and vertical emittances are typically similar or closely matched. At the Relativistic Heavy Ion Collider (RHIC), we experimentally demonstrated a large transverse emittance ratio of 11:1 with gold ion beams at a particle energy of 100 GeV per nucleon, thanks to stochastic cooling and fine decoupling. Furthermore, we demonstrated collisions with flat beams, featuring a transverse beam size ratio of 3:1 for the first time at the RHIC.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

First Study of Antihyperon-Nucleon Scattering Λ ¯ p → Λ ¯ p and Measurement of Λ p → Λ p Cross Section

Using ( 10.087 ± 0.044 ) × 10 9 J / ψ events collected with the BESIII detector at the BEPCII storage ring, the processes Λ p → Λ p and Λ ¯ p → Λ ¯ p are studied, where the Λ / Λ ¯ baryons are produced in the process J / ψ → Λ Λ ¯ and the protons are the hydrogen nuclei in the cooling oil of the beam pipe. Clear signals are observed for the two reactions. The cross sections in − 0.9 ≤ cos θ Λ / Λ ¯ ≤ 0.9 are measured to be σ ( Λ p → Λ p ) = ( 12.2 ± 1.6 stat ± 1.1 syst ) and σ ( Λ ¯ p → Λ ¯ p ) = ( 17.5 ± 2.1 stat ± 1.6 syst ) mb at the Λ / Λ ¯ momentum of 1.074 GeV / c within a range of ± 0.017 GeV / c , where the θ Λ / Λ ¯ are the scattering angles of the Λ / Λ ¯ in the Λ p / Λ ¯ p rest frames. Furthermore, the differential cross sections of the two reactions are also measured, where there is a slight tendency of forward scattering for Λ p → Λ p , and a strong forward peak for Λ ¯ p → Λ ¯ p . We present an approach to extract the total elastic cross sections by extrapolation. The study of Λ ¯ p → Λ ¯ p represents the first study of antihyperon-nucleon scattering, and these new measurements will serve as important inputs for the theoretical understanding of the (anti)hyperon-nucleon interaction. Published by the American Physical Society 2024

Physics↗

Measurements of Normalized Differential Cross Sections of Inclusive η Production in e + e − Annihilation at Energy from 2.0000 to 3.6710 GeV

Using data samples collected with the BESIII detector operating at the BEPCII storage ring, the cross section of the inclusive process e + e − → η + X , normalized by the total cross section of e + e − → hadrons , is measured at eight center-of-mass energy points from 2.0000 to 3.6710 GeV. These are the first measurements with momentum dependence in this energy region. Our measurement shows a significant discrepancy compared to the existing fragmentation functions. To address this discrepancy, a new QCD analysis is performed at the next-to-next-to-leading order with hadron mass corrections and higher twist effects, which can explain both the established high-energy data and our measurements reasonably well. Published by the American Physical Society 2024

Physics↗

Measurement of the Isolated Nuclear Two-Photon Decay in Ge 72

The nuclear two-photon or double-gamma (2 γ ) decay is a second-order electromagnetic process whereby a nucleus in an excited state emits two gamma rays simultaneously. To be able to directly measure the 2⁢ γ decay rate in the low-energy regime below the electron-positron pair-creation threshold, we combined the isochronous mode of a storage ring with Schottky resonant cavities. The newly developed technique can be applied to isomers with excitation energies down to ~100 keV and half-lives as short as ~10 ms. The half-life for the 2⁢ γ decay of the first-excited 0 + state in bare 72 Ge ions was determined to be 23.9(6) ms, which strongly deviates from expectations.

59 ≤ A ≤ 89↗

First Proton-Induced Cross Sections on a Stored Rare Ion Beam: Measurement of Te 118 ( p , γ ) for Explosive Nucleosynthesis

We present the first nuclear cross-section measurements of (p,$\gamma$) and (p,n) reactions on 118 Te at energies relevant for the $\gamma$-process nucleosynthesis. Absolute cross-section values for center-of-mass energies of 6, 7 and 10 MeV are provided, together with a theoretical extrapolation to the Gamow window. This experiment marks the first time that direct proton-induced reactions have been measured on a radioactive ion beam at the Experimental Storage Ring (ESR) at GSI, Darmstadt. This paves the way for a large variety of measurements, delivering new constraints for explosive nucleosynthesis and for physics beyond nuclear stability.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Removal of spurious data in Bragg coherent diffraction imaging: an algorithm for automated data preprocessing

Bragg coherent diffraction imaging (BCDI) provides a powerful tool for obtaining high-resolution structural information from nanocrystalline materials. Here a BCDI sample consisting of a large number of randomly oriented nanoscale crystals is considered. Ideally, only one crystal is oriented to produce a Bragg peak on the detector. However, diffraction from other crystals often produces additional signals on the detector. Before the measured diffraction patterns can be processed into structural images, scientists routinely need to manually identify and remove the `alien' intensities from sources other than the intended crystal. With the development of modern high-coherence storage rings, such as the upgraded Advanced Photon Source (APS), the already slow process of manual preprocessing will be untenable for the large volumes of data that will be produced. An automated method of identifying and deleting alien intensities is proposed. This method exploits the fact that BCDI of a perfect crystal produces diffraction data with inversion symmetry around the Bragg peak. This approach uses the machine learning clustering method DBSCAN to distinguish between diffraction from multiple sources, and then calculates cluster size and inversion symmetry to assess whether clusters of intensity belong to desired data or alien signals. This approach can dramatically reduce the amount of time spent manually processing data, allowing BCDI data processing capabilities to keep pace with the technological advances of fourth-generation synchrotron light sources.

36 MATERIALS SCIENCE↗

Selected advances in small-angle scattering and applications they serve in manufacturing, energy and climate change

Innovations in small-angle X-ray and neutron scattering (SAXS and SANS) at major X-ray and neutron facilities offer new characterization tools for researching materials phenomena relevant to advanced applications. For SAXS, the new generation of diffraction-limited storage rings, incorporating multi-bend achromat concepts, dramatically decrease electron beam emittance and significantly increase X-ray brilliance over previous third-generation sources. This results in intense X-ray incident beams that are more compact in the horizontal plane, allowing significantly improved spatial resolution, better time resolution, and a new era for coherent-beam SAXS methods such as X-ray photon correlation spectroscopy. Elsewhere, X-ray free-electron laser sources provide extremely bright, fully coherent, X-ray pulses of <100 fs and can support SAXS studies of material processes where entire SAXS data sets are collected in a single pulse train. Meanwhile, SANS at both steady-state reactor and pulsed spallation neutron sources has significantly evolved. Developments in neutron optics and multiple detector carriages now enable data collection in a few minutes for materials characterization over nanometre-to-micrometre scale ranges, opening up real-time studies of multi-scale materials phenomena. SANS at pulsed neutron sources is becoming more integrated with neutron diffraction methods for simultaneous structure characterization of complex materials. In this paper, selected developments are highlighted and some recent state-of-the-art studies discussed, relevant to hard matter applications in advanced manufacturing, energy and climate change.

36 MATERIALS SCIENCE↗

FMX – the Frontier Microfocusing Macromolecular Crystallography Beamline at the National Synchrotron Light Source II

Two new macromolecular crystallography (MX) beamlines at the National Synchrotron Light Source II, FMX and AMX, opened for general user operation in February 2017 [Schneider et al. (2013). J. Phys. Conf. Ser. 425 , 012003; Fuchs et al. (2014). J. Phys. Conf. Ser. 493 , 012021; Fuchs et al. (2016). AIP Conf. Proc. SRI2015 , 1741 , 030006]. FMX, the micro-focusing Frontier MX beamline in sector 17-ID-2 at NSLS-II, covers a 5–30 keV photon energy range and delivers a flux of 4.0 × 10 12 photons s −1 at 1 Å into a 1 µm × 1.5 µm to 10 µm × 10 µm (V × H) variable focus, expected to reach 5 × 10 12 photons s −1 at final storage-ring current. This flux density surpasses most MX beamlines by nearly two orders of magnitude. The high brightness and microbeam capability of FMX are focused on solving difficult crystallographic challenges. The beamline's flexible design supports a wide range of structure determination methods – serial crystallography on micrometre-sized crystals, raster optimization of diffraction from inhomogeneous crystals, high-resolution data collection from large-unit-cell crystals, room-temperature data collection for crystals that are difficult to freeze and for studying conformational dynamics, and fully automated data collection for sample-screening and ligand-binding studies. FMX's high dose rate reduces data collection times for applications like serial crystallography to minutes rather than hours. With associated sample lifetimes as short as a few milliseconds, new rapid sample-delivery methods have been implemented, such as an ultra-high-speed high-precision piezo scanner goniometer [Gao et al. (2018). J. Synchrotron Rad. 25 , 1362–1370], new microcrystal-optimized micromesh well sample holders [Guo et al. (2018). IUCrJ , 5 , 238–246] and highly viscous media injectors [Weierstall et al. (2014). Nat. Commun. 5 , 3309]. The new beamline pushes the frontier of synchrotron crystallography and enables users to determine structures from difficult-to-crystallize targets like membrane proteins, using previously intractable crystals of a few micrometres in size, and to obtain quality structures from irregular larger crystals.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A WISER way for simulating the performance of gratings

Soft X-ray monochromators for synchrotron radiation sources have been continuously developed over the years, improving energy resolution and stability. Great effort has been made in improving the surface quality of the optics involved, reaching values permitting diffraction-limited images. Still, one problem has not been solved, nor fully understood, yet: groove placing errors. Nowadays, these are one of the major factors responsible for resolving the power reduction of diffraction-gratings-based X-ray monochromators. Despite decades of use of gratings, there is not yet a universally established method for predicting and simulating the effect of groove placing errors on monochromator performance. This is especially important in the new scenario of high-coherent X-ray sources, i.e. diffraction-limited storage rings and free-electron lasers. To address this problem, in this article an approach based on WISER (Wavefront propagatIon Simulation codE libRary) is presented. WISER is a physical optics simulation package, also available in the user-friendly Orange Synchrotron Radiation Suite – OASYS. Even though it was originally conceived to assess the focusing performance of X-ray mirrors in the presence of height defects, it perfectly simulates the performance of a periodic (or quasi-periodic) structure like a diffraction grating. In this article, the way to use WISER and its application to a specific case, e.g. the design of a monochromator for the upgrade of a beamline at the Advanced Light Source, are shown. A simple rule for estimating how well the grooves are placed on a grating, based on calculation of the Strehl ratio, is also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Recent Improvements of the SNS Extraction Kicker Power Supplies

A total of 14 extraction kickers., with one as the hot spare., are in service to extract protons out of the storage ring at the SNS. The jitter issue and the short lifetime of the switches were resolved after the thyratrons were replaced with solid state switches in 2018. This paper discusses the recent improvements. Two thyristor switches suffered overheating damage in separate incidents. One was due to the oil pump failure and the other was the result of a disconnected oil hose. An ultrasonic flow meter and a fiber optic temperature monitoring system have been installed for each extraction kicker power supply. The flow meter continuously monitors the entire tank oil flow. The temperature monitor detects the thyristor switch real-time temperatures in three locations. Fault thresholds are selected so that the thyristor switches are protected from overheating damage. Alarms are configured to alert staff to take actions before faults occur. In addition., the cause of an intermittent misfire issue was identified, and the solution was implemented. Lastly., a future oscilloscope upgrade and an oil level sensor are discussed.

Tan, Yugang↗

Magnetic Field Optimization of an In-Vacuum Undulator at NSLS-II Transactions on Applied Superconductivity

A 3.0 m long In-Vacuum Undulator (IVU) is employed at the National Synchrotron Light Source II (NSLS-II) for the Hard X-ray Nanoprobe (HXN) beamline providing structural and X-ray fluorescence imaging with world-leading spatial resolution. On July 1 st 2018 a gearbox shaft in the gap drive train assembly sheared due to corrosion fatigue caused by stress due to mechanical misalignment. Furthermore, the device was extracted from the storage ring and measured. The magnetic field measurements detected a degradation of the magnetic performance as well as a localized demagnetization of the magnetic modules of the first 3 upstream periods. We describe here the mechanical repairs and the magnetic phase shimming optimization implemented to restore the spectral performance of the device.

43 PARTICLE ACCELERATORS↗

Fabrication and Testing of 18-mm-Period, 0.5-m-Long Nb 3 Sn Superconducting Undulator

The Advanced Photon Source at Argonne National Laboratory, in collaboration with FNAL and LBNL, is developing a Nb 3 Sn superconducting undulator with the goal of installing this device on the APS storage ring and providing APS users with the novel radiation source. A series of short, similar to ~ 8-cm-long, 18-mm-period undulator prototype magnets have been designed, fabricated, and tested. The same design was scaled to fabricate a 0.5-m-long undulator prototype. Tests of this prototype showed that the designed peak magnetic field of 1.2 T at 850 A was successfully achieved. It represents at least a 20% improvement in comparison with a NbTi SCU having the same period and magnetic gap. Test results and lessons learned from the design process are reported here.

43 PARTICLE ACCELERATORS↗