Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Storage capacity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Thermodynamics and kinetics of 2D g-GeC monolayer as an anode materials for Li/Na-ion batteries

Development of high capacity anode materials is one of the essential strategies for next-generation high-performance Li/Na-ion batteries. Rational design, using density functional theory, can expedite the discovery of these anode materials. Here, we propose a new anode material, germanium carbide, g-GeC, for Li/Na-ion batteries. Our results show that g-GeC possesses both benefits of the high stability of graphene and the strong interaction between Li/Na and germanene. The single-layer germanium carbide, g-GeC, can be lithiated/sodiated on both sides yielding Li 2 GeC and Na 2 GeC with a storage capacity as high as 633 mA h/g. Besides germagraphene’s 2D honeycomb structure, fast charge transfer, and high (Li/Na)-ion diffusion and negligible volume change further enhance the anode performance. These findings provide valuable insights into the electronic characteristics of newly predicted 2D g-GeC nanomaterial as a promising anode for (Li/Na)-ion batteries.

25 ENERGY STORAGE↗

Model-based predictive control of multi-stage air-source heat pumps integrated with phase change material-embedded ceilings

This paper presents a model-based predictive control strategy to optimize the operations of phase change material (PCM) ceiling panels coupled with a multi-stage air-source heat pump. A three-stage prototype heat pump unit has been built and tested in the laboratory, with the low and medium stages designed for space heating/cooling and the high compression stage dedicated to charging of the PCM energy storage. To facilitate optimal control of the integrated heat pump system, a mixed-integer linear programming formulation is derived through linearization of the heat pump model and a mixed-integer reformulation of the PCM dynamic governing equations. A predictive control strategy is synthesized based on the resultant control formulation and implemented in a receding horizon scheme that optimizes the PCM charging and the zone temperature schedules simultaneously to leverage both the passive (associated with building construction materials) and active (PCM) storage capacities of a building. The control strategy has been tested along with three benchmarking control scenarios using a co-simulation platform for a prototypical detached house in Atlanta, GA. In this study, test results showed that application of the proposed control strategy to the PCM-integrated heat pump could provide 27.1% electricity cost savings while a fine tuned rule-based control strategy could achieve cost savings of 20.4%, compared to a baseline case without PCM storage, under a time-of-use rate tariff.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The NEEDS Data Base Management and Archival Mass Memory System

A Data Base Management System and an Archival Mass Memory System are being developed that will have a 10 to the 12th bit on-line and a 10 to the 13th off-line storage capacity. The integrated system will accept packetized data from the data staging area at 50 Mbps, create a comprehensive directory, provide for file management, record the data, perform error detection and correction, accept user requests, retrieve the requested data files and provide the data to multiple users at a combined rate of 50 Mbps. Stored and replicated data files will have a bit error rate of less than 10 to the -9th even after ten years of storage. The integrated system will be demonstrated to prove the technology late in 1981.

Bailey, G. A.↗

Modulating thermal load through lightweight residential building walls using thermal energy storage and controlled precooling strategy

Precooling is a recognized technique for reducing cooling energy in buildings during peak hours by shifting load to off-peak hours. This technique is particularly effective in buildings with high thermal mass, because of their large thermal energy storage capacity, and in commercial buildings due to their variable electricity pricing based on time-of-use rates. Precooling in residential buildings has been a matter of limited interest in the past because of their low thermal mass and typically uniform electricity pricing rate. While previous studies on precooling primarily focused on cost savings, an important aspect of precooling is the thermal load modulation, which could be very effective in managing peak demand in lightweight residential buildings integrated with thermal energy storage systems. In this study, we examine different precooling strategies to manage the heat gains in lightweight building walls integrated with phase-change materials. We create nine different precooling profiles by controlling the interior temperature, and then evaluate the influence of the precooling profiles on four key building energy performance parameters: total heat gain, peak heat gain, maximum heat gain during peak hours, and time at which peak occurs. To thoroughly understand the fundamental physics, we first consider hypothetical climates and obtain the optimal precooling strategy required to achieve maximum peak shedding and shifting while minimizing the total heat gains. We then extend the model to Baltimore, Maryland, and estimate the benefits of the optimized precooling strategy under real conditions. The optimal precooling strategy proposed in this study can shift the peak heat gain by up to 14 hours, thereby reducing the heat gain during peak period by up to 95%, at the expense of a 23% increase in the total heat gains.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Metal hydride composition-derived parameters as machine learning features for material design and H 2 storage

Though hydrogen is a promising energy carrier for a green future, many challenges persist. One is the difficulty in engineering storage solutions, with metal hydrides being a leading contender among solid-state strategies. To facilitate efficient searching of candidate materials, ridge regression, simple decision trees, random forest ensembles, and gradient boosting ensembles were employed to predict the energy of formation, with the random forest ensemble resulting in the lowest test set error. First, two public databases, Materials Project and HydPark, were searched for metal hydrides. Feature engineering was performed before the models were developed, resulting in electronegativity, density, atomic density, d-character, f-character, band gap, hydrogen weight fraction, magnetization, temperature, and pressure being retained. The models were then benchmarked by the lowest test error before a random forest ensemble was used to populate entries missing energy of formation. Furthermore, all were then scored by hydrogen storage capacity and energy of formation suitability. Readily available features including several derived from only the chemical formula which were found to be highly predictive. and so are promising for high-throughput screening of arbitrary novel hydride formulations and blends for thermodynamic feasibility.

25 ENERGY STORAGE↗

Additive Manufacturing of Thermal Energy Storage Composites with Microencapsulated Phase Change Materials Supported in a Multi-Polymer Matrix

Advanced manufacturing techniques, such as additive manufacturing (AM), that can directly integrate phase change materials (PCMs) have garnered interest in recent years due to their potential for development of highly efficient thermal energy storage architectures. Complex, high surface area geometries embedded with PCMs that are only feasible with AM can improve thermal management with reduced material waste. Our work focuses on developing composite filaments with microencapsulated phase change materials (MEPCM) bound within a single or dual polymer matrix that can be processed through standard filament extruders and additively manufactured using off-the-shelf 3D printers. Polymer powders, rather than polymer pellets, were key to homogenously mixed filaments achieving high MEPCM loadings with no deterioration in thermal energy storage (TES) capability during extrusion. Composite filaments contain upwards of 60 wt% MEPCM and were printed without loss in feature resolution, print speed, or layer adhesion. Storage enthalpies of printed composites range from 100 - 130 kJ/kg, which were within 5% of the theoretical enthalpy based on weight fraction of MEPCM and maintained enthalpies within 1% over 500 thermal cycles. We can reliably manufacture low density, high surface area structures like 15% gyroid infill, along with dense, compact pucks at a 100% concentric infill. Prints were also scalable to a 900 cm3 honeycomb infill heat exchanger model that has an estimated energy storage capacity of 9 Wh.

3D printing↗

Construction of MoS 2 /NiS 2 heterostructure with fast interfacial reaction kinetics for ultrafast sodium storage

Constructing heterostructure is a valid method to reinforcing sodium storage performance of transition metal chalcogenides materials. Herein, a simple, safe and controllable one step hydrothermal method is proposed to synthesize MoS 2 /NiS 2 heterostructure. Due to the difference in band gaps and work functions of MoS 2 and NiS 2 , the charges are redistributed at the MoS 2 /NiS 2 heterointerfaces, thereby accelerating the migration of electrons and Na + . The heterointerfaces provide extra active sites for storing Na + , thus increasing the sodium storage capacity of the heterostructure. Furthermore, the distinct redox potentials of NiS 2 and MoS 2 promote the structural stability of MoS 2 /NiS 2 heterostructure during the electrochemical reaction processes. Consequently, the obtained MoS 2 /NiS 2 heterostructure exhibits superior rate properties (339.4 mAh g –1 at 10 A g –1 ) and ultra-stable cycling stability (480.5 mAh g –1 after 350 cycles at 1 A g –1 ). Finally, this paper presents a valid strategy for creating heterostructure anodes with excellent sodium storage properties.

25 ENERGY STORAGE↗

Efficient prediction of concentrating solar power plant productivity using data clustering

Concentrating solar power (CSP) plants convert solar energy to electricity and can be deployed with a thermal storage capability to shift electricity generation from time periods with available solar resource to those with high electricity demand or electricity price. Rigorous optimization of plant design and operational strategies can improve the market-competitiveness and commercial viability; however, such optimization may require hundreds of annual performance simulations, each of which can be computationally expensive when including considerations such as optimization of dispatch scheduling, sub-hourly time resolution, and stochastic effects due to uncertain weather or electricity price forecasts. This paper proposes a methodology to reduce the computational burden associated with simulation of electricity yield and revenue for CSP plants over a single- or multi-year period. Data-clustering techniques are employed to select a small number of limited-duration time blocks for simulation that, when appropriately weighted, can reproduce generation and revenue over a single year or within each year of a multi-year period. After selection of appropriate data features and weighting factors defining similarity between time-series profiles, the methodology captured annual revenue within 2.3%, 1.7%, or 1.2% using simulation of 10, 30, or 50 three-day exemplar time blocks, respectively, for each of three single-year location/weather/market scenarios and five plant configurations ranging from low to high solar multiple and storage capacity. When applied to multi-year datasets, the proposed methodology can capture inter-year variability that is unavailable from typical meteorological year (TMY) datasets while simultaneously requiring simulation of less than a single year of data.

14 SOLAR ENERGY↗

Standard Characterization Techniques for Inorganic Phase Change Materials

Salt hydrates are promising candidates for phase change materials (PCMs) because of their low cost and high energy storage capacity. However, practical applications of salt hydrate based PCMs are limited due to their poor thermal cycling performance caused by phase separation and supercooling. Various techniques, including differential scanning calorimetry (DSC) and transient plane source (TPS) have been used to characterize salt hydrate based PCMs but may not provide full understanding of the degradation mechanism. In this manuscript, salt hydrate and graphite composites are prepared. Temperature history (T-History) method and X-ray diffraction (XRD) are utilized for measuring melting temperature, energy storage, and latent heat degradation of the PCM composites. Highlighting the importance of each technique and how each technique plays an important role in analyzing salt hydrates performance accurately. Temperature history, and X-ray diffraction are also used in conjunction to precisely predict the cause of degradation in salt hydrate PCMs with thermal cycling, as in most literatures the cause of degradation in salt hydrate are attributed to phase segregation, supercooling, and change in stichometry water concentration without any scientific validation.

Kumar, Navin↗

Overview of Upcoming Process Improvement Efforts at the Saltstone Facilities at the Savannah River Site - 20474

The Saltstone Facilities at the Savannah River Site (SRS) process and dispose of low activity salt solution waste generated by other liquid waste facilities. Today in the Liquid Waste System (LWS), approximately 125 million liters of salt waste remain to be processed. The Saltstone Production Facility (SPF) receives the decontaminated salt waste, which is mixed with dry feeds consisting of cement, fly ash and slag to produce the saltstone. The mixed slurry is pumped to the Saltstone Disposal Units (SDUs) for safe disposal in the Saltstone Disposal Facility (SDF). To support continuous Salt Waste Processing Facility (SWPF) operations at annual processing volumes many times higher than present, significant modifications are required to ensure that the SPF has the capacity to support the throughput of salt waste. These changes include several infrastructure upgrades that are being worked through the Enhanced Low Activity Waste Disposal (ELAWD) project. In addition to infrastructure upgrades, Savannah River Remediation (SRR), the Savannah River Site's Liquid Waste Contractor for the U.S. Department of Energy, has identified a flowsheet improvement opportunity of implementing a cement-free saltstone formulation to eliminate cement from the current three component formulation. This two-component formulation would simplify the procurement, transport, off-loading, and storage of the premix materials, and increase the storage capacity for the individual components. This flowsheet, when implemented, will reduce operational risk and improve throughput necessary to achieve disposal rates necessary for SWPF operations. Research has been completed to confirm the feasibility of this formulation, with the new cement-free flowsheet expected to be implemented in the next few years. Improvements have also been identified downstream of the SPF to increase SDU utilization. Specifically, a concentrated effort has taken place to raise the fill height in SDU 6 to the full disposal height, 13 meters, to maximize the usage of each SDU in support of the liquid waste disposal mission. This improvement has been made through additional thermal modeling and improved process understanding to create a SDU flammability model and control strategy more representative of facility operations. This work will allow for the completion of construction and operational readiness for SDU 7 while filling SDU 6 to ensure there is no lapse in available space once SWPF starts up. A summary of these improvements as they relate to increased throughput will be provided along with associated status. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Admissible Powertrain Alternatives for Heavy-Duty Fleets: A Case Study on Resiliency and Efficiency

Heavy-duty vehicles dominate global freight movement and primarily rely on fossil-derived diesel fuel. However, fluctuations in crude oil prices and evolving emissions regulations have prompted interest in alternative powertrains to enhance fleet energy resiliency. This study paired real-world operational data from a large commercial fleet with high-fidelity vehicle models to evaluate the potential for replacing diesel internal combustion engine (ICE) trucks with alternative powertrain architectures. The baseline vehicle for this analysis is a diesel-powered ICE truck. Alternatives include ICE trucks fueled by bio- and renewable diesel, compressed natural gas (CNG) or hydrogen (H 2 ), as well as plug-in hybrid (PHEV), fuel cell electric (FCEV), and battery electric vehicles (BEV). While most alternative powertrains resulted in some payload capacity loss, the overall fleetwide impact was negligible due to underutilized payload capacity for the specific fleet considered in this study. For sleeper cab trucks, CNG-powered trucks achieved the highest replacement potential, covering 85% of the fleet. In contrast, H 2 and BEV architectures could replace fewer than 10% and 1% of trucks, respectively. Day cab trucks, with shorter daily routes, showed higher replacement potential: 98% for CNG, 78% for H 2 , and 34% for BEVs. However, achieving full fleet replacement would still require significant operational changes such as route reassignment and enroute refueling, along with considerable improvements to onboard energy storage capacity. Additionally, the higher total cost of ownership (TCO) for alternative powertrains remains a key challenge. This study also evaluated lifecycle impacts across various fuel sources, both fossil and bio-derived. Bio-derived synthetic diesel fuels emerged as a practical option for diesel displacement without disrupting operations. Conversely, H 2 and electrified powertrains provide limited lifecycle impacts under the current energy scenario. This analysis highlights the complexity of replacing diesel ICE trucks with admissible alternatives while balancing fleet resiliency, operational demands, and emissions goals. These results reflect a US-based fleet’s duty cycles, payloads, GVWR allowances, and an assumption of depot-only refueling/recharging. Applicability to other fleets and regions may differ based on differing routing practices or technical features such as battery swapping.

BEV↗

An Integrated Feasibility Study of Reservoir Thermal Energy Storage (RTES) in Portland, OR, USA

In regions with long cold overcast winters and sunny summers, Deep Direct-Use (DDU) can be coupled with Reservoir Thermal Energy Storage (RTES) technology to take advantage of pre-existing subsurface permeability to save summer heat for later use during cold seasons. Many aquifers worldwide are underlain by permeable regions (reservoirs) containing brackish or saline groundwater that has limited beneficial use due to poor water quality. We investigate the utility of these relatively deep, slow flowing reservoirs for RTES by conducting an integrated feasibility study in the Portland Basin, Oregon, USA, developing methods and obtaining results that can be widely applied to RTES systems elsewhere. As a case study, we have conducted an economic and social cost-benefit analysis for the Oregon Health and Science University (OHSU), a teaching hospital that is recognized as critical infrastructure in the Portland Metropolitan Area. Our investigation covers key factors that influence feasibility including 1) the geologic framework, 2) heat and fluid flow modeling, 3) capital and maintenance costs, 4) the regulatory framework, and 5) operational risks. By pairing a model of building seasonal heat demand with an integrated model of RTES resource supply, we determine that the most important factors that influence RTES efficacy in the study area are operational schedule, well spacing, the amount of summer heat stored (in our model, a function of solar array size), and longevity of the system. Generally, heat recovery efficiency increases as the reservoir and surrounding rocks warm, making RTES more economical with time. Selecting a base-case scenario, we estimate a levelized cost of heat (LCOH) to compare with other sources of heating available to OHSU and find that it is comparable to unsubsidized solar and nuclear, but more expensive than natural gas. Additional benefits of RTES include energy resiliency in the event that conventional energy supplies are disrupted (e.g., natural disaster) and a reduction in fossil fuel consumption resulting in a smaller carbon footprint. Key risks include reservoir heterogeneity and a possible reduction in permeability through time due to scaling (mineral precipitation). Lastly, a map of thermal energy storage capacity for the Portland Basin yields a total of 43,400 GWh, suggesting tremendous potential for RTES in the Portland Metropolitan Area.

14 SOLAR ENERGY↗

Cation-Driven Assembly of Bilayered Vanadium Oxide and Graphene Oxide Nanoflakes to Form Two-Dimensional Heterostructure Electrodes for Li-Ion Batteries

Lithium preintercalated bilayered vanadium oxide (LVO or δ-Li x V 2 O 5 ·nH 2 O) and graphene oxide (GO) nanoflakes were assembled using a concentrated lithium chloride solution and annealed under vacuum at 200 °C to form two-dimensional (2D) δ-Li x V 2 O 5 ·nH 2 O and reduced GO (rGO) heterostructures. Here we found that the Li + ions from LiCl enhanced the oxide/carbon heterointerface formation and served as stabilizing ions to improve structural and electrochemical stability. The graphitic content of the heterostructure could be easily controlled by changing the initial GO concentration prior to assembly. We found that increasing the GO content in our heterostructure composition helped inhibit the electrochemical degradation of LVO during cycling and improved the rate capability of the heterostructure. A combination of scanning electron microscopy and X-ray diffraction was used to help confirm that a 2D heterointerface formed between LVO and GO, and the final phase composition was determined using energy-dispersive X-ray spectroscopy and thermogravimetric analysis. Scanning transmission electron microscopy and electron energy-loss spectroscopy were additionally used to examine the heterostructures at high resolution, mapping the orientations of rGO and LVO layers and locally imaging their interlayer spacings. Further, electrochemical cycling of the cation-assembled LVO/rGO heterostructures in Li-ion cells with a non-aqueous electrolyte revealed that increasing the rGO content led to improved cycling stability and rate performance, despite slightly decreased charge storage capacity. The heterostructures with 0, 10, 20, and 35 wt % rGO exhibited capacities of 237, 216, 174, and 150 mAh g –1 , respectively. Moreover, the LVO/rGO-35 wt % and LVO/rGO-20 wt % heterostructures retained 75% (110 mAh g–1) and 67% (120 mAh g –1 ) of their initial capacities after increasing the specific current from 20 to 200 mA g –1 , while the LVO/rGO-10 wt % sample retained only 48% (107 mAh g –1 ) of its initial capacity under the same cycling conditions. In addition, the cation-assembled LVO/rGO electrodes exhibited enhanced electrochemical stability compared to electrodes prepared through physical mixing of LVO and GO nanoflakes in the same ratios as the heterostructure electrodes, further revealing the stabilizing effect of a 2D heterointerface. The cation-driven assembly approach, explored in this work using Li + cations, was found to induce and stabilize the formation of stacked 2D layers of rGO and exfoliated LVO. The reported assembly methodology can be applied for a variety of systems utilizing 2D materials with complementary properties for applications as electrodes in energy storage devices.

25 ENERGY STORAGE↗

Advanced Materials and Additive Manufacturing for Phase Change Thermal Energy Storage and Management: A Review

Abstract Phase change materials (PCMs) can enhance the performance of energy systems by time shifting or reducing peak thermal loads. The effectiveness of a PCM is defined by its energy and power density—the total available storage capacity (kWh m −3 ) and how fast it can be accessed (kW m −3 ). These are influenced by both material properties as well as geometry of the energy systems; however, prior efforts have primarily focused on improving material properties, namely, maximizing latent heat of fusion and increasing thermal conductivity. The latter is often at the expense of the former. Advanced manufacturing techniques hold tremendous potential to enable co‐optimization of material properties and device geometry, while potentially reducing material waste and manufacturing time. There is an emerging body of research focused on additive manufacturing of PCM composites and devices for thermal energy storage (TES) and thermal management. In this article, the fundamentals and applications of PCMs are reviewed and recent additive manufacturing advances in latent heat TES for both the PCM composite and associated heat exchanger are discussed. A forward‐looking perspective on the future and potential of PCM additive manufacturing for TES and thermal management is provided.

25 ENERGY STORAGE↗

Regional Assessment for the CO 2 Storage Potential in the Northern Niagaran Pinnacle Reef Trend

The Midwest Regional Carbon Sequestration Partnership (MRCSP) was founded in 2003 as part of the U.S. Department of Energy’s (DOE’s) Regional Carbon Sequestration Partnership initiative. Since its founding, MRCSP has made significant strides toward making CCUS a viable option for states in the region. The public/private consortium, funded through the DOE Regional Carbon Sequestration Initiative, brings together nearly 40 industry partners and 10 states. Battelle, as the project lead, oversees research, development and operations and coordinates activities among the partners. The incremental, phased approach has built a valuable knowledge base for the industry and paved the way for commercial-scale adoption of CCUS technologies. From 2008 to 2020, MRCSP Phase III focused on the development of large-scale injection projects. This report is part of a series of reports prepared under the Midwestern Regional Carbon Sequestration Partnership (MRCSP) Phase III (Development Phase). These reports summarize and detail the findings of the work conducted under the Phase III project. The report describes the regional analysis of the Northern Niagaran Pinnacle Reef Trend (NNPRT) in Northern Michigan as part of the MRCSP programs Regional Assessment goals. The goal of this task was to perform an initial assessment of the geologic storage capacity and injectivity of the Northern Fairway of Michigan’s Niagaran Reef Trend. This was achieved through three main objectives: 1) development of a reef atlas, 2) understanding the regional trends in geology, and 3) estimating CO 2 and CO 2 -EOR resources. Data collected across multiple subtasks were integrated into a mappable database that could be accessed from many of the leading software. The reef atlas was used to map the reefs and associated characteristics across the entire NNPRT. Several methodologies were explored to estimate the CO 2 and CO 2 -EOR resources across the trend which included three scenarios: 1) storage only using fluid substitution and volumetric estimations, 2) CO 2 -EOR which applied proximity analysis concepts and measured performance metrics from the Core Energy reefs to predict performance at all oil reefs, and 3) enhanced storage scenario which combined CO 2 -EOR with fluid substitution to represent maximized storage after completion of CO 2 -EOR.

01 COAL, LIGNITE, AND PEAT↗

Optimizing and Exploring Untapped Micro-Hydro Hybrid Systems: a Multi-Objective Approach for Crystal Lake as a Large-Scale Energy Storage Solution

Increasing electricity demand and concerns about climate change and fossil fuel consumption have highlighted the importance of renewable energy resources and storage systems. This paper proposes a method for exploring untapped pumped hydro storage potentials to accommodate intermittent renewable energy generation profiles. Hourly measured data from 2022 in Benzie County, Michigan, United States, were gathered for system sizing and a thorough, realistic analysis. By employing the multi-objective grey wolf optimization algorithm, we formulated optimal sizing and energy-management strategies for three different scenarios. Unlike similar studies, the 3rd with triple objective functions (OFs) scenario aims to maximize both reliability and ecological OFs while minimizing the cost OF. It has shown promising results with multiple solutions, considering economic, environmental, and reliability factors. A case study conducted in Crystal Lake, Michigan, revealed that although Crystal Lake would function only as a micro-hydro power facility, it is a promising and huge storage unit with a substantial storage capacity of around 14.9734GWh. The system investigated is significant in the USA due to its rapid deployment capabilities, minimal construction requirements, and ease of integration with the distribution grid. The fuzzy logic method was employed to identify the best non-dominant solution among the other solutions. Furthermore, these outcomes include a notably low levelized cost of energy at 0.046147$/kWh, a robust index of reliability of 99.705%, and a significant reduction in CO₂ emissions amounting to 7.9142×10 3 tons/year, when considering the triple OFs. The paper’s methodology provides valuable insights for regions aiming to utilize renewable energy from untapped storage sources.

13 HYDRO ENERGY↗

An approach for fast and accurate simulation of phase change material based thermal energy storage in buildings

Latent heat thermal energy storage (LHTES) has significant potential for mitigating peak electricity demand and enabling load shifting in buildings. Phase Change Material embedded heat exchangers (PCM-HX) can significantly improve energy demand management due to high storage capacity. However, PCM-HX evaluation typically depends on computationally expensive fully transient simulations, posing significant challenges for scalable system- and building-level energy assessments across different climates and system architectures. This paper presents a generalized, accurate, and computationally efficient methodology for simulating building energy systems integrated with LHTES. The PCM-HX transient performance is represented by performance maps generated using a Generalized Resistance-Capacitance Model (GRCM) that enables accurate predictions of arbitrary PCM-HXs at low computational cost. The feasibility of the proposed approach was verified using a case study considering a dual-mode heat pump-thermal energy storage (HP-TES) system simulated in Modelica with Spawn of EnergyPlus™ for a DOE prototype small office building in two locations: Tampa, FL, and International Falls, MN. The PCM-HX performance maps provided accurate predictions of PCM-HX transient behavior, with mean absolute percentage deviations within 2–4% compared to GRCM while also achieving at least 1800× reduction in computational time. Moreover, the HP-TES system achieved energy savings of up to 17.4% in Tampa, FL, and 62.2% in International Falls, MN, demonstrating the broader applicability of the proposed methodology across different climate zones. This work highlights the importance of robust PCM-HX models in enabling accurate and computationally efficient building-level simulations and enabling future research opportunities for investigating optimized HP-TES designs and advanced control strategies for grid-interactive buildings.

Modelica↗