Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Stimulus responsive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Genetic predisposition to low bone mass is paralleled by an enhanced sensitivity to signals anabolic to the skeleton

The structure of the adult skeleton is determined, in large part, by its genome. Whether genetic variations may influence the effectiveness of interventions to combat skeletal diseases remains unknown. The differential response of trabecular bone to an anabolic (low-level mechanical vibration) and a catabolic (disuse) mechanical stimulus were evaluated in three strains of adult mice. In low bone-mineral-density C57BL/6J mice, the low-level mechanical signal caused significantly larger bone formation rates (BFR) in the proximal tibia, but the removal of functional weight bearing did not significantly alter BFR. In mid-density BALB/cByJ mice, mechanical stimulation also increased BFR, whereas disuse significantly decreased BFR. In contrast, neither anabolic nor catabolic mechanical signals influenced any index of bone formation in high-density C3H/HeJ mice. Together, data from this study indicate that the sensitivity of trabecular tissue to both anabolic and catabolic stimuli is influenced by the genome. Extrapolated to humans, these results may explain in part why prophylaxes for low bone mass are not universally effective, yet also indicate that there may be a genotypic indication of people who are at reduced risk of suffering from bone loss.

Non-NASA Center↗

Smooth Pursuit of Flicker-Defined Motion

We examined the pursuit response to stimuli defined by space-variant flicker of a dense random dot carrier pattern. On each frame, every element of the pattern could change polarity, with a probability given by a two-dimensional Gaussian distribution. A normal distribution produces a circular region of twinkle, while inverting the distribution results in a spot of static texture in a twinkling surround. In this latter case, the carrier texture could be stationary, or could move with the twinkle modulator,thereby producing first-order motion in the region of the spot. While the twinkle-defined spot produces a strong sensation of motion, the complementary stimulus defined by the absence of twinkle does not;when viewed peripherally, it appears to move in steps even when the generating distribution moves smoothly. We examined pursuit responses to these stimuli using two techniques: 1) the eye movement correlogram, obtained by cross-correlating eye velocity with the velocity of a randomly-moving stimulus; and 2) delayed visual feedback, where transient stabilization of a target can produce spontaneous oscillations of the eye, with a period empirically observed to vary linearly with the applied delay. Both techniques provide an estimate of the internal processing time, which can be as short as100 milliseconds for a first-order target. Assessed by the correlogram method, the response to flicker defined motion is delayed by more than 100 milliseconds, and significantly weaker (especially in the vertical dimension). When initially presented in the delayed feedback condition, purely saccadic oscillation is observed. One subject eventually developed smooth oscillations (albeit with significant saccadic intrusions), showing a period-versus-delay slope similar to that observed for first-order targets. This result is somewhat surprising, given that we interpret the slope of the period-versus-delayfunction as reflecting the balance between position- and velocity-sensitive inputs to pursuit.

smooth pursuit↗

Smooth Pursuit of Flicker-Defined Motion

We examined the pursuit response to stimuli defined by space-variant flicker of a dense random dot carrier pattern. On each frame, every element of the pattern could change polarity, with a probability given by a two-dimensional Gaussian distribution. A normal distribution produces a circular region of twinkle, while inverting the distribution results in a spot of static texture in a twinkling surround. In this latter case, the carrier texture could be stationary, or could move with the twinkle modulator, thereby producing first-order motion in the region of the spot. While the twinkle-defined spot produces a strong sensation of motion, the complementary stimulus defined by the absence of twinkle does not, when viewed peripherally, it appears to move in steps even when the generating distribution moves smoothly. We examined pursuit responses to these stimuli using two techniques: 1) the eye movement correlogram, obtained by cross-correlating eye velocity with the velocity of a randomly-moving stimulus; and 2) delayed visual feedback, where transient stabilization of a target can produce spontaneous oscillations of the eye, with a period empirically observed to vary linearly with the applied delay. Both techniques provide an estimate of the internal processing time, which can be as short as 100 milliseconds for a first-order target. Assessed by the correlogram method, the response to flicker-defined motion is delayed by more than 100 milliseconds, and significantly weaker (especially in the vertical dimension). When initially presented in the delayed feedback condition, purely saccadic oscillation is observed. One subject eventually developed smooth oscillations (albeit with significant saccadic intrusions), showing a period-versus-delay slope similar to that observed for first-order targets. This result is somewhat surprising, given that we interpret the slope of the period-versus-delay-function as reflecting the balance between position- and velocity-sensitive inputs to pursuit.

eye movements↗

Cockpit Window Edge Proximity Effects on Judgements of Horizon Vertical Displacement

To quantify the influence of a spatially fixed edge on vertical displacement threshold, twenty-four males (12 pilots, 12 non-pilots) were presented a series of forced choice, paired comparison trials in which a 32 deg arc wide, thin, luminous horizontal stimulus line moved smoothly downward through five angles from a common starting position within a three second-long period. The five angles were 1.4, 1.7, 2, 2.3, and 2.6 deg. Each angle was presented paired with itself and the other four angles in all combinations in random order. For each pair of trials the observer had to choose which trial possessed the largest displacement. A confidence response also was made. The independent variable was the angular separation between the lower edge of a stable 'window' aperture through which the stimulus was seen to move and the lowest position attained by the stimulus. It was found that vertical displacement accuracy is inversely related to the angle separating the stimulus and the fixed window edge (p = .05). In addition, there is a strong tendency for pilot confidence to be lower than that of non-pilots for each of the three angular separations. These results are discussed in erms of selected cockpit features and as they relate to how pilots judge changes in aircraft pitch attitude.

Haines, R. F.↗

Three-dimensional organization of otolith-ocular reflexes in rhesus monkeys. II. Inertial detection of angular velocity

1. The dynamic contribution of otolith signals to three-dimensional angular vestibuloocular reflex (VOR) was studied during off-vertical axis rotations in rhesus monkeys. In an attempt to separate response components to head velocity from those to head position relative to gravity during low-frequency sinusoidal oscillations, large oscillation amplitudes were chosen such that peak-to-peak head displacements exceeded 360 degrees. Because the waveforms of head position and velocity differed in shape and frequency content, the particular head position and angular velocity sensitivity of otolith-ocular responses could be independently assessed. 2. During both constant velocity rotation and low-frequency sinusoidal oscillations, the otolith system generated two different types of oculomotor responses: 1) modulation of three-dimensional eye position and/or eye velocity as a function of head position relative to gravity, as presented in the preceding paper, and 2) slow-phase eye velocity as a function of head angular velocity. These two types of otolith-ocular responses have been analyzed separately. In this paper we focus on the angular velocity responses of the otolith system. 3. During constant velocity off-vertical axis rotations, a steady-state nystagmus was elicited that was maintained throughout rotation. During low-frequency sinusoidal off-vertical axis oscillations, dynamic otolith stimulation resulted primarily in a reduction of phase leads that characterize low-frequency VOR during earth-vertical axis rotations. Both of these effects are the result of an internally generated head angular velocity signal of otolithic origin that is coupled through a low-pass filter to the VOR. No change in either VOR gain or phase was observed at stimulus frequencies larger than 0.1 Hz. 4. The dynamic otolith contribution to low-frequency angular VOR exhibited three-dimensional response characteristics with some quantitative differences in the different response components. For horizontal VOR, the amplitude of the steady-state slow-phase velocity during constant velocity rotation and the reduction of phase leads during sinusoidal oscillation were relatively independent of tilt angle (for angles larger than approximately 10 degrees). For vertical and torsional VOR, the amplitude of steady-state slow-phase eye velocity during constant velocity rotation increased, and the phase leads during sinusoidal oscillation decreased with increasing tilt angle. The largest steady-state response amplitudes and smallest phase leads were observed during vertical/torsional VOR about an earth-horizontal axis. 5. The dynamic range of otolith-borne head angular velocity information in the VOR was limited to velocities up to approximately 110 degrees/s. Higher head velocities resulted in saturation and a decrease in the amplitude of the steady-state response components during constant velocity rotation and in increased phase leads during sinusoidal oscillations. 6. The response characteristics of otolith-borne angular VORs were also studied in animals after selective semicircular canal inactivation. Otolith angular VORs exhibited clear low-pass filtered properties with a corner frequency of approximately 0.05-0.1 Hz. Vectorial summation of canal VOR alone (elicited during earth-vertical axis rotations) and otolith VOR alone (elicited during off-vertical axis oscillations after semicircular canal inactivation) could not predict VOR gain and phase during off-vertical axis rotations in intact animals. This suggests a more complex interaction of semicircular canal and otolith signals. 7. The results of this study show that the primate low-frequency enhancement of VOR dynamics during off-vertical axis rotation is independent of a simultaneous activation of the vertical and torsional "tilt" otolith-ocular reflexes that have been characterized in the preceding paper. (ABSTRACT TRUNCATED).

NASA Discipline Neuroscience↗

Inhibition of the spider heartbeat by gravity and vibration

The rate and vigor of the spider heartbeat is controlled by an external pacemaker. A mechanical feature of the spider cardio-vascular system is the production of high serum pressure in the prosoma and the legs. This appears to be the source for leg extension. The lyriform organ on the patella of the leg is sensitive to vibratory and kinesthetic stimuli. This sensitivity depends upon the degree of leg extension. Thus the activity of the heart and the response characteristics of the sense receptor are related. The effect of a supra-threshold vibratory or gravitational stimulus is to produce an inhibition and a tachycardia of the spider heartbeat.

Finck, A.↗

Impaired sympathetic vascular regulation in humans after acute dynamic exercise

1. The reduction in vascular resistance which accompanies acute dynamic exercise does not subside immediately during recovery, resulting in a post-exercise hypotension. This sustained vasodilatation suggests that sympathetic vascular regulation is altered after exercise. 2. Therefore, we assessed the baroreflex control of sympathetic outflow in response to arterial pressure changes, and transduction of sympathetic activity into vascular resistance during a sympatho-excitatory stimulus (isometric handgrip exercise) after either exercise (60 min cycling at 60% peak aerobic power (VO2,peak)) or sham treatment (60 min seated rest) in nine healthy subjects. 3. Both muscle sympathetic nerve activity and calf vascular resistance were reduced after exercise (-29.7 +/- 8.8 and -25.3 +/- 9.1%, both P < 0.05). The baroreflex relation between diastolic pressure and sympathetic outflow was shifted downward after exercise (post-exercise intercept, 218 +/- 38 total integrated activity (heartbeat)-1; post-sham intercept, 318 +/- 51 total integrated activity (heartbeat)-1, P < 0.05), indicating less sympathetic outflow across all diastolic pressures. Further, the relation between sympathetic activity and vascular resistance was attenuated after exercise (post-exercise slope, 0.0031 +/- 0.0007 units (total integrated activity)-1 min; post-sham slope, 0.0100 +/- 0.0033 units (total integrated activity)-1 min, P < 0.05), indicating less vasoconstriction with any increase in sympathetic activity. 4. Thus, both baroreflex control of sympathetic outflow and the transduction of sympathetic activity into vascular resistance are altered after dynamic exercise. We conclude that the vasodilation which underlies post-exercise hypotension results from both neural and vascular phenomena.

Non-NASA Center↗

Steady-state evoked potentials possibilities for mental-state estimation

The use of the human steady-state evoked potential (SSEP) as a possible measure of mental-state estimation is explored. A method for evoking a visual response to a sum-of-ten sine waves is presented. This approach provides simultaneous multiple frequency measurements of the human EEG to the evoking stimulus in terms of describing functions (gain and phase) and remnant spectra. Ways in which these quantities vary with the addition of performance tasks (manual tracking, grammatical reasoning, and decision making) are presented. Models of the describing function measures can be formulated using systems engineering technology. Relationships between model parameters and performance scores during manual tracking are discussed. Problems of unresponsiveness and lack of repeatability of subject responses are addressed in terms of a need for loop closure of the SSEP. A technique to achieve loop closure using a lock-in amplifier approach is presented. Results of a study designed to test the effectiveness of using feedback to consciously connect humans to their evoked response are presented. Findings indicate that conscious control of EEG is possible. Implications of these results in terms of secondary tasks for mental-state estimation and brain actuated control are addressed.

Junker, Andrew M.↗

Cardiovascular function in space flight

Changes in orthostatic heart rate have been noted universally in Soviet and U.S. crewmembers post space flight. The magnitude of these changes appears to be influenced by mission duration, with increasing orthostatic intolerance for the first 7-10 days of flight and then a partial recovery in the orthostatic heart rate response. Fluid loading has been used as a countermeasure to this postflight orthostatic intolerance. Previous reports have documented the effectiveness of this technique, but it has also been noted that the effectiveness of volume expansion diminishes as flight duration exceeds one week. The response of carotid baroreceptor function was investigated utilizing a commercially available neck collar which could apply positive and negative pressure to effect receptor stimulation. Bedrest studies had validated the usefulness and validity of the device. In these studies it was shown that carotid baroreceptor function curves demonstrated less responsiveness to orthostatic stimulation than control individuals. Twelve Space Shuttle crewmembers were examined pre- and postflight from flights lasting from 4-5 days. Plots of baroreceptor function were constructed and plotted as change in R-R interval vs. carotid distending pressure (an orthostatic stimulus). Typical sigmoidal curves were obtained. Postflight the resting heart rate was higher (smaller R-R interval) and the range of R-R value and the slope of the carotid sigmoidal response were both depressed. These changes were not significant immediately postflight (L + O), but did become significant by the second day postflight (L + 2), and remained suppressed for several days thereafter. It is hypothesized that the early adaptation to space flight involves a central fluid shift during the initial days of flight, but subsequent alterations in neural controlling mechanisms (such as carotid baroreceptor function) contribute to orthostatic intolerance.

Review↗

Ocular Vestibular Evoked Myogenic Potentials Using Head Striker Stimulation

Introduction: Over the last two decades, several studies have been published on the impact of long-duration (i.e., 22 days or longer) spaceflight on the central nervous system (CNS). In consideration of the health and performance of crewmembers in flight and post-flight, we are conducting a controlled prospective longitudinal study to investigate the effects of spaceflight on the extent, longevity and neural bases of sensorimotor, cognitive, and neural changes. Multiple studies have demonstrated the effects of spaceflight on the vestibular system. One of the supporting tests conducted in this protocol is the Vestibular Evoked Myogenic Potential (VEMP) test that provides a unilateral measure of otolith (saccule and utricle) function. A different approach was taken for ocular VEMP (oVEMP) testing using a head striker system (Wackym et al. 2012). The oVEMP is generally considered to be a measure of utricle function. The the otolithic input to the inferior oblique muscle is predominately from the utricular macula. Thus, quantitatively, oVEMP tests utricular function. Another practical extension of these relationships is that the oVEMP reflects the superior vestibular nerve function. Methods: Ground testing was administered on 16 control subjects and for 8 subjects over four repeated sessions spanning 70 days. The oVEMP was elicitied via a hand held striker by a vibrotactile pulse presented at the rate of 1 Hz for 24 seconds on the side of the head as subjects lay supine on a gurney. Subjects were directed to gaze approximately 25 degrees above straight ahead in semi-darkness. For the oVEMP electromyograms will be recorded with active bipolar electrodes (Delsys Inc., Boston, MA) on the infra-orbital ridge 1 cm below the eyelid with a reference electrode on the below the knee cap. The EMG potentials were amplified; band-pass filtered using a BagnoliTM Desktop EMG System (Delsys Inc., Boston, MA, USA). This EMG signal is sampled at 10 kHz and the data stimulus onset to 100 MS was averaged over 24 trial repetitions for the vibrotactile VEMP. The typical oVEMP EMG response is an excitatory potential with first peak occurring at 11-12 ms and second peak at 18 ms. This requires a total recording time of approximately 29 seconds per trial which includes 5 seconds of no vibrotactile stimulation at the beginning of the protocol. The primary dependent measures consist of the latency and peak-to-peak amplitude from the EMG signals, which will be normalized to EMG levels at the beginning of the protocol. Data were collected for 3 repeated trials with striker stimulation on both the left and right side of the head Results: The oVEMP p1 range was observed at 3-14 ms and n1 at 7-19 ms. The striker system provided a consistent and rapid method for oVEMP testing. Discussion: Crew testing is in progress to determine changes in results between pre and post flight.

De Dios, Y. E.↗

Eye Movement Latencies to Direction Change for Different Classes of Motion

In the analysis of visual motion, local features such as orientation are analyzed early in the cortical processing stream (V1), while integration across orientation and space is thought to occur in higher cortical areas such as MT, MST, etc. If all areas provide inputs to eye movement control centers, we would expect that local properties would drive eye movements with relatively short latencies, while global properties would require longer latencies. When such latencies are observed, they can provide information about when (and where?) various stimulus properties are analyzed. To this end, a stimulus was employed in which local and global properties determining perceived direction-of-motion could be manipulated independently: an elliptical Gabor patch with a drifting carrier, with variable orientation of the carrier grating and the contrast window. We have previously demonstrated that the directional percepts evoked by this stimulus vary between the "grating direction" (the normal to the grating's orientation) and the "window direction" (ARVO 91, 94), and that similar effects can be observed in reflexive eye movements (ARVO 95). Subjects viewed such a stimulus while attempting to maintain steady fixation on the center of the pattern, and the small reflexive eye movements ("stare OKN") were recorded. In the middle of the trial, the orientation of either the grating or the window was rotated smoothly by 30 degrees. Responses to the shift of both grating orientation and window orientation are seen in the average OKN slow phase velocity. Grating rotations produce a rapid OKN rotation to the grating direction (100 ms latency, 300 ms time constant), followed by a slower rebound to the steady state perceived direction midway between the grating and window directions. Window rotations, on the other hand, evoke a slower response (200 ms latency, 500 ms time constant). The results demonstrate multiple cortical inputs to eye movement control: a taste early input driven by orientation, and a slower input from higher areas sensitive to global stimulus properties.

Mulligan, Jeffrey B.↗

Macular bioaccelerometers on earth and in space

Spaceflight offers the unique opportunity to study linear bioaccelerometers (vestibular maculas) in the virtual absence of a primary stimulus, gravitational acceleration. Combined morphological-physiological studies of maculas fixed in space and following flight should reveal macular adaptive responses to microgravity, and their time-course. Ground-based research, already begun, using computer-assisted, three-dimensional reconstructions of macular terminal fields will lead to development of computer models of functioning maculas. This research should continue in conjunction with physiological studies, including work with multichannel electrodes.

Ross, M. D.↗

Eye Movements Reveal Hierarchical Motion Processing

Purpose: In the analysis of visual motion, local features such as orientation are analyzed early in the cortical processing stream (V1), while integration across orientation and space is thought to occur in higher cortical areas such as MT, MST, etc. If all areas provide inputs to eye movement control centers, we would expect that local properties would drive eye movements with relatively short latencies, while global properties would require longer latencies. When such latencies are observed, they can provide information about when (and where?) various stimulus properties are analyzed. Methods: The stimulus employed was an elliptical Gabor patch with a drifting carrier, in which the orientations of the carrier grating and the contrast window were varied independently. We have previously demonstrated that the directional percepts evoked by this stimulus vary between the "grating direction" (the normal to the grating's orientation) and the "window direction", and that similar effects can be observed in reflexive eye movements. Subjects viewed such a stimulus while attempting to maintain steady fixation on the center of the pattern, and the small reflexive eye movements ("stare OKN") were recorded. In the middle of the trial, the orientation of either the grating or the window was rotated smoothly by 30 degrees. Results: Responses to the shift of both grating orientation and window orientation are seen in the average OKN slow phase velocity. Grating rotations produce a rapid OKN rotation to the grating direction (100 ms latency, 300 ms time constant), followed by a slower rebound to the steady state perceived direction midway between the grating and window directions. Window rotations, on the other hand, evoke a slower response (200 ms latency, 500 ms time constant). Conclusions: The results demonstrate multiple cortical inputs to eye movement control: a fast, early input driven by orientation, and a slower input from higher areas sensitive to global stimulus properties.

Mulligan, Jeffrey B.↗

Hypercortisolemia alters muscle protein anabolism following ingestion of essential amino acids

Debilitating injury is accompanied by hypercortisolemia, muscle wasting, and disruption of the normal anabolic response to food. We sought to determine whether acute hypercortisolemia alters muscle protein metabolism following ingestion of a potent anabolic stimulus: essential amino acids (EAA). A 27-h infusion (80 microg. kg(-1). h(-1)) of hydrocortisone sodium succinate mimicked cortisol (C) levels accompanying severe injury (>30 microg/dl), (C + AA; n = 6). The control group (AA) received intravenous saline (n = 6). Femoral arteriovenous blood samples and muscle biopsies were obtained during a primed (2.0 micromol/kg) constant infusion (0.05 micromol. kg(-1). min(-1)) of l-[ring-(2)H(5)]phenylalanine before and after ingestion of 15 g of EAA. Hypercortisolemia [36.5 +/- 2.1 (C + AA) vs. 9.0 +/- 1.0 microg/dl (AA)] increased postabsorptive arterial, venous, and muscle intracellular phenylalanine concentrations. Hypercortisolemia also increased postabsorptive and post-EAA insulin concentrations. Net protein balance was blunted (40% lower) following EAA ingestion but remained positive for a greater period of time (60 vs. 180 min) in the C + AA group. Thus, although differences in protein metabolism were evident, EAA ingestion improved muscle protein anabolism during acute hypercortisolemia and may help minimize muscle loss following debilitating injury.

Clinical Trial↗

An Approach for the Assessment of System Upset Resilience

This report describes an approach for the assessment of upset resilience that is applicable to systems in general, including safety-critical, real-time systems. For this work, resilience is defined as the ability to preserve and restore service availability and integrity under stated conditions of configuration, functional inputs and environmental conditions. To enable a quantitative approach, we define novel system service degradation metrics and propose a new mathematical definition of resilience. These behavioral-level metrics are based on the fundamental service classification criteria of correctness, detectability, symmetry and persistence. This approach consists of a Monte-Carlo-based stimulus injection experiment, on a physical implementation or an error-propagation model of a system, to generate a system response set that can be characterized in terms of dimensional error metrics and integrated to form an overall measure of resilience. We expect this approach to be helpful in gaining insight into the error containment and repair capabilities of systems for a wide range of conditions.

Torres-Pomales, Wilfredo↗

Responses evoked from man by acoustic stimulation

Clicks and other acoustic stimuli evoke time-locked responses from the brain of man. The properties of the waves recordable within the interval from 1 to 10 msec after the stimuli strike the eardrum are discussed along with factors influencing the waves in the 100 to 500 msec epoch. So-called brainstem responses from a normal young adult are considered. No waves were observed for clicks to weak to be heard. With increasing stimulus strength the waves become larger in amplitude and their latency shortens.

Galambos, R.↗

Renal response to seven days of lower body positive pressure in the squirrel monkey

As a ground-based model for weightlessness, the response of the chair-trained squirrel monkey to lower body positive pressure (LBPP) was evaluated in a length of study similar to a typical Space Shuttle mission (7 days). Results were compared to time control experiments that included chair-sitting without exposure to LBPP. Chronic exposure to LBPP results in an acute diuretic and natriuretic response independent of changes in plasma aldosterone concentrations and produces a chronic reduction in fluid volume lasting the duration in the stimulus.

Churchill, Susanne↗

Assessment of Psychophysiological Responses During Motion Sickness Testing

The purpose of this investigation is to evaluate a methodology designed to accurately trace the temporal progression of motion sickness and space motion sickness symptoms. With this method, subjects continuously monitor their own motion sickness symptoms during exposure to a provocative stimulus as symptoms occur, in contrast to previous methods during which subjects report symptoms verbally at discrete time intervals. This method not only is comparable to previous methods in the type of symptoms that subjects report, but subjects report symptoms more frequently. Frequent reporting of motion sickness symptoms allows researchers to detail the waxing and waning of motion sickness symptoms for each individual. Previous research has shown that physiological responses to motion sickness stimuli are characterized by unique individual differences in response patterns. By improving our assessment of motion sickness symptoms with continuous monitoring of symptoms, the relationship between specific physiological responses and sickness levels can be more accurately determined for each individual. Results from this study show significant positive relationships between skin conductance levels and symptom levels for ten individuals; a significant positive relationship between temperature and symptom levels for 5 of 10 individuals; and both positive and negative relationships between respiration, heart rate, blood volume pulse and symptom levels. Continuous monitoring of motion sickness symptoms can be used to more accurately assess motion sickness to aid in the evaluation of countermeasures. In addition, recognition of the onset of symptoms that are strongly related to specific physiological responses could be used as cues to initiate procedures (e.g., Autogenic Feedback Training) to prevent the development of severe motion sickness symptoms.

Stoud, Cynthia S.↗