Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Stations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

The criticality incident detection system omission cases for the fuel routes at EDF energy power stations - 14280

Criticality safety cases have been produced to justify the omission of criticality alarms from the fuel routes of EDF Energy's UK power stations. This work has addressed the UK regulator's expectations that adequate criticality warning systems should be provided wherever fissile material is present, unless a safety case shows that no criticality excursion could give any individual a whole body dose exceeding the annual whole body dose limit of 20 mSv, or that the predicted frequency of such excursions is acceptably low. In the UK, EDF Energy operates eight nuclear power stations; one Pressurized Water Reactor (PWR) and seven Advanced Gas-cooled Reactor stations (AGRs). At these stations, the term 'fuel route' is used to encompass all of the ex-reactor arrangements for the handling and storage of both new fuel and discharged irradiated fuel. These fuel routes were all designed in the 1980's (or earlier), using sound deterministic criticality safety principles, from which it was concluded that criticality alarms were not required in any of these areas. Subsequent changes to UK regulations have resulted in the need for the stations' criticality safety cases to be updated to include formal justifications for the omission of criticality alarms from these fuel routes. The EDF Energy Criticality Incident Detection System (CIDS) omission cases have been produced using the principles originally developed for UKAEA in the early 1960's by Aspinall and Daniels. These principles continue to be regarded as a best-practice approach by UK industry. Modern UK regulations also incorporate the ALARP principle, which requires operators to minimize and balance all of the safety risks from power station operations, so that the risks to both the public and to workers are As Low As is Reasonably Practicable. This paper describes how the work undertaken used the so-called Aspinall and Daniels criteria in conjunction with the requirements of the ALARP principle. The fuel storage pond at the Sizewell B PWR was addressed by dose calculations to show that, from the shielding effects of the concrete structure and the pond water, the potential consequences of a criticality accident could not result in a radiation dose in excess of 20 mSv. All of the other fuel route areas were addressed on the basis that, even if all of the active engineered and administrative criticality controls were to fail, a criticality accident would still not be reasonably expected, i.e. the predicted frequencies of all such excursions are acceptably low. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Hydrogen station in situ back-to-back fueling data for design and modeling

Hydrogen technologies are rapidly spreading, with significant attention to the mobility sector requiring a robust and widespread fueling infrastructure. Hydrogen stations are indeed fundamental to transitioning from pilot projects towards large-scale implementation in many countries. Operating under extreme conditions, the new stations need more informed designs and equipment to meet the growing demand and their more frequent utilization. Via a set of experimental research activities and investigated scenarios carried out at the Cal State LA Hydrogen Research and Fueling Facility, here this paper shares a novel and comprehensive set of data collected over a period of one year on fueling events frequency and refueling process station behaviors. A performance evaluation of the station is presented under different load scenarios in severe conditions during "back-to-back fuelings", with monitoring of fundamental parameters for infrastructure sizing, including dynamic cooling response, pressure levels, thermodynamics, and the state of charge of the vehicle. The presented data analysis could surely contribute as closer-to-reality inputs for a variety of station performance modeling tools.

08 HYDROGEN↗

National Hydrogen Scenarios: How Many Stations, Where, and When?

This report examines development scenarios for hydrogen station networks needed to support a national rollout of fuel cell electric vehicles (FCEVs) in the United States. It was developed within the framework of the U.S. public-private collaboration known as H2USA, with approximately 50 partners committed to enabling hydrogen infrastructure for FCEV adoption. In this report, an internally consistent analytic modeling method simulates how station networks might develop across cities and regions, assuming that successful planning and coordination activities result in a rollout of FCEVs and stations similar to California's. These scenarios are not forecasts of future market outcomes. Rather, they provide insight to various public and private stakeholders engaged in the planning and coordination required to help facilitate their own station networks, while reducing hydrogen station investment risks.

08 HYDROGEN↗

A Study of the Positions and Velocities of a Space Station and a Ferry Vehicle During Rendezvous and Return

A study is made of the families of non-thrusting ascent trajectories of a ferry vehicle during rendezvous with an orbiting body, referred to as a space station. It is shown that these trajectories may also be interpreted as descent trajectories of the ferry from the station to the earth. The rendezvous trajectories start at the end of the boost period (assumed to be 60 miles) and terminate at the station. The equations of motion are derived and results are shown for two typical orbits of the station: a 300-mile cir­cular orbit and a 100-to-500-mile elliptical orbit. Trajectories are described in terms of a rotating co­ordinate system fixed in the station and launch con­ditions are tabulated in terms of non-rotating inertial coordinates. Boundaries are given in terms of launch (at time of booster burnout) and rendezvous conditions for the example cases. The considerations used to calculate these boundaries and the significance of some of the trends are discussed.

TRAJECTORY↗

Alternative Fueling Station Locations

Alternative fueling stations are located throughout the United States and Canada, and their availability continues to grow. The Alternative Fuels Data Center (AFDC) maintains a website where you can find alternative fueling stations near you or on a route, obtain counts of alternative fueling stations by state, view maps, and more. The most recent dataset available for download here provides a "snapshot" of the alternative fueling station information for compressed natural gas (CNG), ethanol (E85), propane/liquefied petroleum gas (LPG), biodiesel (B20 and above), electric vehicle charging, hydrogen, and liquefied natural gas (LNG), as of July 29, 2021.

alt fuel↗

Assuring pulsation-free flow in a directly pressurized fuel delivery at a retail hydrogen station

When a retail hydrogen station operates using booster compressors to directly fill cars, a need for an additional high-pressure buffer volume is present, in order to mitigate potential pressure pulsations in the system. Looking at the case of the Cal State LA Hydrogen Fueling Station, pulsations with a magnitude up to 6.7 MPa were observed with no buffer volume during 70 MPa fueling. Thus the focus was placed on determining the minimum buffer volume required to ensure pulsation free operation to the entire downstream system (booster compressors, piping and the vehicle hydrogen hardware). A mathematical model of volumes involved has been developed and compared to experimental measurements. The station configuration allows isolating one or more of the four high-pressure buffer tanks with which the station was upgraded to reduce pulsations. Each tank has a volume of 0.05 m 3 . A relatively simple model developed shows a strong correlation with the experiments in determining the maximum pulse and the minimum additional high-pressure buffer volume. Effectively, one buffer tank would have provided a proper operation of the station by keeping the pressure pulsation magnitude under 0.2 MPa.

08 HYDROGEN↗

Grid Voltage Control Analysis for Heavy-Duty Electric Vehicle Charging Stations

This paper presents an analysis of grid voltage control strategies for heavy-duty electric vehicle charging stations. The performance of three voltage control approaches—including power factor control, standardized volt-volt ampere reactive (VAR) curve control, and customized volt-VAR curve control—are investigated and evaluated for three different sizes of charging stations, including a single-port charging station, a midsized three-port charging station, and six-port travel center. The charging stations are placed on multiple locations of four different types of distribution systems to obtain a comprehensive performance analysis of the voltage control approaches under different scenarios. To quantitively compare the performance of the three voltage control approaches, a series of metrics are designed to quantify the performance and contribute to the comprehensive analysis.

47 OTHER INSTRUMENTATION↗

Pypromice: A Python Package for Processing Automated Weather Station Data

The pypromice Python package is for processing and handling observation datasets from automated weather stations (AWS). It is primarily aimed at users of AWS data from the Geological Survey of Denmark and Greenland (GEUS), which collects and distributes in situ weather station observations to the cryospheric science research community. Functionality in pypromice is primarily handled using two key open-source Python packages, xarray (Hoyer & Hamman, 2017) and pandas (The pandas development team, 2020). A defined processing workflow is included in pypromice for transforming original AWS observations (Level 0, L0) to a usable, CF-convention-compliant dataset (Level 3, L3) (Figure 1). Intermediary processing levels (L1,L2) refer to key stages in the workflow, namely the conversion of variables to physical measurements and variable filtering (L1), cross-variable corrections and user-defined data flagging and fixing (L2), and derived variables (L3). Information regarding the station configuration is needed to perform the processing, such as instrument calibration coefficients and station type (one-boom tripod or two-boom mast station design, for example), which are held in a toml configuration file. Two example configuration files are provided with pypromice , which are also used in the package’s unit tests. More detailed documentation of the AWS design, instrumentation, and processing steps are described in Fausto et al. (2021).

pypromice↗

Regulations, Codes, and Standards (RCS) for Multi-Fuel Motor Vehicle Dispensing Stations

In the United States, requirements for liquid motor vehicle fuelling stations have been in place for many years. Requirements for motor vehicle fuelling stations for gaseous fuels, including hydrogen, are relatively new. These requirements have, in the United States, been developed along different code and standards paths. The liquid fuels have been addressed in a single document and the gaseous fuels have been addressed in documents specific to an individual gas. The result of these parallel processes is that multi-fuel stations are subject to requirements in several fuelling regulations, codes, and standards (RCS). This paper describes a configuration of a multi-fuel motor vehicle fuelling station and provides a detailed breakdown of the codes and standards requirements. The multi-fuel station would dispense what the U.S. Department of Energy defines as the six key alternative fuels: biodiesel, electricity, ethanol, hydrogen, natural gas, and propane. The paper will also identify any apparent gaps in RCS and potential research projects that could help fill these gaps.

33 ADVANCED PROPULSION SYSTEMS↗

Grid Voltage Control Analysis for Heavy-Duty Electric Vehicle Charging Stations: Preprint

This paper presents an analysis of voltage control strategies for heavy duty electric vehicle (EV) charging stations. The performance of three voltage control approaches including power factor control, preset volt-var curve control, and customized volt-var curve control, have been investigated and evaluated for three different sizes of charging stations, including single-port small charging station, three-port middle size charging station, and 6-port travel center. The charging stations have been placed on various locations of four different types of distribution systems, to obtain a comprehensive performance analysis of the three voltage control approaches under different scenarios. To quantitively compare the performance of the three voltage control approaches, a series of metrics have been designed to quantify the performance and contribute to the comprehensive analysis summary.

47 OTHER INSTRUMENTATION↗

Heavy-Duty Hydrogen Station Equipment Performance Device (HD HyStEP) Specifications and Design Considerations

The original Hydrogen Station Equipment Performance (HyStEP) device was commissioned in 2015 and was critical for the rapid validation of light-duty (LD) hydrogen fueling stations. As applications for hydrogen as a heavy-duty (HD) transportation fuel continue to grow, new heavy-duty stations are being developed to fuel these vehicles that require larger onboard storage tank systems to meet HD transportation demands and drive cycles. The differences in size and geometry from LD vehicles have driven the creation of new hydrogen fueling protocols that will enable safe and economical fueling of HD vehicles. With the new requirements that are set out in HD fueling protocols like SAE J601-5, a new HyStEP-like device is needed to evaluate the capabilities of high-flow hydrogen stations to fuel HD vehicles to the new protocol standard. To create a heavy-duty HyStEP (HD HyStEP) device, an effort has been undertaken to evaluate the requirements that would form the basis for the design of a successful HD HyStEP device. The primary design goal of this HD HyStEP device is its capability of following a test methodology similar to what is outlined in CSA HGV 4.3, which guides the validation of LD fueling dispensers but with adjustments to verify adherence to the HD fueling protocols (SAE J2601-5) for 70 MPa and 35 MPa pressure class vehicles rather than the LD fueling protocols (SAE J2601). The design presented here aims to provide information that enables the creation of an HD HyStEP device that achieves the primary design goal while being informed by the years of experience from the current HyStEP operators.

08 HYDROGEN↗

Techno-economic and thermodynamic analysis of pre-cooling systems at gaseous hydrogen refueling stations

In this study, we conducted a techno-economic and thermodynamic analysis of precooling units (PCUs) at hydrogen refueling stations and developed a cost-minimizing design algorithm for the PCU observing the SAE J2601 refueling protocol for T40 stations. In so doing, we identified major factors that affect PCU cost and energy use. The hydrogen precooling energy intensity depends strongly on the station utilization rate, but approaches 0.3 kWh e /kg-H 2 at full utilization. In early fuel cell electric vehicle markets where utilization of the refueling capacity is low, the overhead cooling load (to keep the heat exchanger cold at -40°C) results in significantly high PCU energy intensity because only a small amount of hydrogen is being dispensed. We developed a parameterized precooling energy intensity prediction formula as a function of the ambient temperature and station utilization rate. We also found that the Joule-Thomson effect of the flow control device introduces a significant increase in temperature upstream of the PCU’s heat exchanger (HX), which impacts the PCU design capacity. An optimal PCU (per dispenser, at 35°C HX inlet temperature) consists of a 13-kW refrigerator and a HX with 1400 kg of thermal mass (aluminum), which currently costs $70,000 (uninstalled). Finally, the total (installed) capital and operation cost of PCU at a fully utilized hydrogen refueling station adds $0.50/kg-H 2 .

08 HYDROGEN↗

International challenge to model the long-range transport of radioxenon released from medical isotope production to six Comprehensive Nuclear-Test-Ban Treaty monitoring stations

After performing a first multi-model exercise in 2015 a comprehensive and technically more demanding atmospheric transport modelling challenge was organized in 2016. Release data were provided by the Australian Nuclear Science and Technology Organization radiopharmaceutical facility in Sydney (Australia) for a one month period. Measured samples for the same time frame were gathered from six International Monitoring System stations in the Southern Hemisphere with distances to the source ranging between 680 (Melbourne) and about 17,000 km (Tristan da Cunha). Participants were prompted to work with unit emissions in pre-defined emission intervals (daily, half-daily, 3-hourly and hourly emission segment lengths) and in order to perform a blind test actual emission values were not provided to them. Despite the quite different settings of the two atmospheric transport modelling challenges there is common evidence that for long-range atmospheric transport using temporally highly resolved emissions and highly space-resolved meteorological input fields has no significant advantage compared to using lower resolved ones. As well an uncertainty of up to 20% in the daily stack emission data turns out to be acceptable for the purpose of a study like this. Model performance at individual stations is quite diverse depending largely on successfully capturing boundary layer processes. No single model-meteorology combination performs best for all stations. Moreover, the stations statistics do not depend on the distance between the source and the individual stations. Finally, it became more evident how future exercises need to be designed. Set-up parameters like the meteorological driver or the output grid resolution should be pre-scribed in order to enhance diversity as well as comparability among model runs.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Grid impact analysis using controller-hardware-in-the-loop for high-power vehicle charging stations

A controller-hardware-in-the-loop (CHIL) architecture for the evaluation of grid impacts arising from high-power vehicle charging stations is presented in this paper. Unlike simulation-based studies, the proposed method can be used to capture the interactions of the grid and the charging load along with charger controllers in real time. The proposed method can be used to evaluate the impact of charging load on the grid in terms of voltage variations and line congestion. The proposed CHIL platform allows for de-risking the vehicle charging station deployment by simulating the complex interactions among all the components of a vehicle charging station - i.e., the grid, vehicle, and charger controller - in a realistic manner before using the charging station in a grid. Further, the proposed CHIL approach can be used to evaluate the voltage regulation causalities of the vehicle charging station. Experimental results are presented in the paper to illustrate the applicability of the proposed method in a laboratory environment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Instrument performance study on the short and long pulse options of the second Spallation Neutron Source target station

The Spallation Neutron Source (SNS) facility at the Oak Ridge National Laboratory is designed with an upgrade option for a future low repetition rate, long wavelength second target station. This second target station is intended to complement the scientific capabilities of the 1.4 MW, 60 Hz high power first target station. Two upgrade possibilities have been considered, the short and the long pulse options. In the short pulse mode, proton extraction occurs after the pulse compression in the accumulator ring. The proton pulse structure is thus the same as that for the first target station with a pulse width of ∼0.7 μs. In the long pulse mode, protons are extracted as they are produced by the linac, with no compression in the accumulator ring. The time width of the uncompressed proton pulse is ∼1 ms. This difference in proton pulse structure means that neutron pulses will also be different. Neutron scattering instruments thus have to be designed and optimized very differently for these two source options which will directly impact the overall scientific capabilities of the SNS facility. In order to assess the merits of the short and long pulse target stations, we investigated a representative suit of neutron scattering instruments and evaluated their performance under each option. Our results indicate that the short pulse option will offer significantly better performance for the instruments and is the preferred choice for the SNS facility.

43 PARTICLE ACCELERATORS↗

Model-Based Framework to Optimize Charger Station Deployment for Battery Electric Vehicles

The development of battery electric vehicles (BEVs) is accelerating due to their environmental advantages over gasoline and diesel-powered vehicles, including a decrease in air pollution and an increase in energy efficiency. The deployment of charging infrastructure will need to increase to keep pace with demand, especially for large commercial vehicles for which few public chargers currently exist. In this paper, a new flexible framework is proposed for optimizing the placement of charging stations for BEVs, within which different physical models and optimization techniques may be used. Furthermore, a set of metrics is suggested to help enforce complex constraints and facilitate direct comparison between different optimization techniques. Unlike many existing charger placement techniques, the proposed method directly considers the historical driving patterns on a vehicle-by-vehicle basis, using transparent models to assess impacts of candidate charger placements, thus improving the explainability of the results. In the developed framework, modeled BEVs are first generated along the road network to mimic historical traffic data and are simulated traveling along a given route according to a simplified vehicle model. During the simulation, the charger placement problem is initially relaxed to allow vehicles to charge at any node along the road network, and vehicle states are tracked to assess areas of high charging demand. Charging stations are then placed based on the results of the relaxed simulation, and suggested placements are evaluated via road network simulation with fixed charger locations. This proposed framework is applied to a sample problem of placing charging stations along five major highway corridors for Class 8 over-the-road electric trucks. A novel mixed integer programming (MIP) formulation is proposed to optimize charger placements based upon the expected charging demand. Constraints were imposed on the final placement results to limit expected wait times at each station and ensure a minimum threshold of trucking routes are viable for BEVs. The results demonstrate the flexibility and potential effectiveness of the developed model-based framework for scalable charger station deployment.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

AmeriFlux FLUXNET-1F US-xSB NEON Ordway-Swisher Biological Station (OSBS)

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site US-xSB NEON Ordway-Swisher Biological Station (OSBS). This is the FLUXNET version of the carbon flux data for the site US-xSB NEON Ordway-Swisher Biological Station (OSBS) produced by applying the standard ONEFlux (1F) software. Site Description - The Ordway-Swisher Biological Station (OSBS) is operated by the University of Florida and comprises over 9,300 acres. It is a year-round field station established for the long-term study and conservation of unique ecosystems through management, research and education. The Station is located approximately 20 miles east of Gainesville in Melrose (Putnam County, Florida). There are two aquatic arrays at Ordway-Swisher, representing the two dominant aquatic features on the landscape: 1) Suggs lake, a shallow surface water lake that is rich in taxa and biologically active in structure and function; and 2) Barco lake, a deep lake connected to ground water. The forest is maintained by fire and has a relatively open structure: it is managed with prescribed burns at a frequency of 3-4 years.

Network), NEON (National Ecological Observatory↗

Identifying and Correcting Timing Errors at Seismic Stations in and around Iran

A fundamental component of seismic research is the use of phase arrival times, which are central to event location, Earth model development, and phase identification, as well as derived products. Hence, the accuracy of arrival times is crucial. However, errors in the timing of seismic waveforms and the arrival times based on them may go unidentified by the end user, particularly when seismic data are shared between different organizations. Here, we present a method used to analyze travel-time residuals for stations in and around Iran to identify time periods that are likely to contain station timing problems. For the 14 stations with the strongest evidence of timing errors lasting one month or longer, timing corrections are proposed to address the problematic time periods. Finally, two additional stations are identified with incorrect locations in the International Registry of Seismograph Stations, and one is found to have erroneously reported arrival times in 2011.

58 GEOSCIENCES↗