Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Solar heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Numerical simulations of loops heated to solar flare temperatures. III - Asymmetrical heating

A numerical model is defined for asymmetric full solar flare loop heating and comparisons are made with observational data. The Dynamic Flux Tube Model is used to describe the heating process in terms of one-dimensional, two fluid conservation equations of mass, energy and momentum. An adaptive grid allows for the downward movement of the transition region caused by an advancing conduction front. A loop 20,000 km long is considered, along with a flare heating system and the hydrodynamic evolution of the loop. The model was applied to generating line profiles and spatial X-ray and UV line distributions, which were compared with SMM, P78-1 and Hintori data for Fe, Ca and Mg spectra. Little agreement was obtained, and it is suggested that flares be treated as multi-loop phenomena. Finally, it is concluded that chromospheric evaporation is not an effective mechanism for generating the soft X-ray bursts associated with flares.

Cheng, C.-C.↗

The development of a solar residential heating and cooling system

The MSFC solar heating and cooling facility was assembled to demonstrate the engineering feasibility of utilizing solar energy for heating and cooling buildings, to provide an engineering evaluation of the total system and the key subsystems, and to investigate areas of possible improvement in design and efficiency. The basic solar heating and cooling system utilizes a flat plate solar energy collector, a large water tank for thermal energy storage, heat exchangers for space heating, and an absorption cycle air conditioner for space cooling. A complete description of all systems is given. Development activities for this test system included assembly, checkout, operation, modification, and data analysis, all of which are discussed. Selected data analyses for the first 15 weeks of testing are included, findings associated with energy storage and the energy storage system are outlined, and conclusions resulting from test findings are provided. An evaluation of the data for summer operation indicates that the current system is capable of supplying an average of 50 percent of the thermal energy required to drive the air conditioner. Preliminary evaluation of data collected for operation in the heating mode during the winter indicates that nearly 100 percent of the thermal energy required for heating can be supplied by the system.

Source record↗

Tests of a reduced-scale experimental model of a building solar heating-cooling system

An experimental solar heating and cooling system model has been built and operated, combining elements that are programmable (e.g., heating and cooling load of a building and collected solar energy) with experimental equipment. The experimental system model was based on the loads and components used in the Solar Building Test Facility (SBTF), which includes a 1394 sq m solar collector field at NASA Langley. These tests covered 5 continuous days under summer conditions. For the system model up to 55 percent of the simulated collected solar energy was used for the building load. This amount of solar energy supplied 35 percent of the building cooling load. Heat loss was significant. If tank heat loss were eliminated, which would make it similar to the actual SBTF, 75 percent of the collected solar energy would be used. This amount would supply approximately 50 percent of the building cooling load. A higher fraction of solar energy is possible with a more performance-optimized system.

Namkoong, D.↗

Study of magnetic notions in the solar photosphere and their implications for heating the solar atmosphere

This progress report covers the first year of NASA Grant NAGw-2545, a study of magnetic structure in the solar photosphere and chromosphere. We have made significant progress in three areas: (1) analysis of vorticity in photospheric convection, which probably affects solar atmospheric heating through the stresses it imposes on photospheric magnetic fields; (2) modelling of the horizontal motions of magnetic footpoints in the solar photosphere using an assumed relation between brightness and vertical motion as well as continuity of flow; and (3) observations and analysis of infrared CO lines formed near the solar temperature minimum, whose structure and dynamics also yield important clues to the nature of heating of the upper atmosphere. Each of these areas are summarized in this report, with copies of those papers prepared or published this year included.

Noyes, Robert W.↗

Solar power satellites - Heat engine or solar cells

A solar power satellite is the energy-converting element of a system that can deliver some 10 GW of power to utilities on the earth's surface. We evaluated heat engines and solar cells for converting sunshine to electric power at the satellite. A potassium Rankine cycle was the best of the heat engines, and 50 microns thick single-crystal silicon cells were the best of the photovoltaic converters. Neither solar cells nor heat engines had a clear advantage when all factors were considered. The potassium-turbine power plant, however, was more difficult to assemble and required a more expensive orbital assembly base. We therefore based our cost analyses on solar-cell energy conversion, concluding that satellite-generated power could be delivered to utilities for around 4 to 5 cents a kWh.

Oman, H.↗

A conjecture concerning thermodynamic limits to solar atmospheric heating

Considering the solar atmosphere in its entirety, that large-scale nonadiabatic processes (MHD waves, and so on) effectively tend to yield an 'equalization of temperature', such that the atmospheric temperature is limited to the base temperature associated with its heat source. This conjecture suggests that (1) the chromospheric temperature is limited by the granulation base temperature (10,000 K), (2) the spicule temperatures are limited by the base temperature (100,000 K) where the supergranular cells form, and (3) the quiet coronal temperature is less than or equal to the convection zone base temperature (2,000,000 K). Thermodynamical arguments are provided which may serve to augment the detailed heating models wherein large-scale mechanical energy is transported into the solar atmosphere involving MHD waves, current dissipation, and other nonthermal processes.

Schatten, K. H.↗

Shell Models of RMHD Turbulence and the Heating of Solar Coronal Loops

A simplified nonlinear numerical model for the development of incompressible magnetohydrodynamics in the presence of a strong magnetic field B|| and stratification, nicknamed 'Shell-Atm,' is presented. In planes orthogonal to the mean field, the nonlinear incompressible dynamics is replaced by two-dimensional shell models for the complex variables u and b, allowing one to reach large Reynolds numbers while at the same time carrying out sufficiently long integrations to obtain good statistics at moderate computational cost. The shell models of different planes are coupled by Alfve'n waves propagating along B||. The model may be applied to open or closed magnetic field configurations where the axial field dominates and the plasma pressure is low; here we apply it to the specific case of a magnetic loop of the solar corona heated by means of turbulence driven by photospheric motions, and we use statistics for its analysis. The Alfven waves interact nonlinearly and form turbulent spectra in the directions perpendicular and, through propagation, also parallel to the mean field. A heating function is obtained and shown to be intermittent; the average heating is consistent with values required for sustaining a hot corona and is proportional to the aspect ratio of the loop to the -1.5 power, and haracteristic properties of heating events are distributed as power laws. Crosscorrelations show a delay of dissipation compared with energy content.

corona↗

Solar Thermal Energy Planner (STEP 1): A New Decision Support Tool for Solar Industrial Process Heat Applications

Solar thermal technologies are a promising technology to supply low-cost thermal energy to industrial processes, but there are often significant barriers to entry to industrial owners considering these technologies for their energy demands. To overcome this barrier and convey economic value to customers, NREL and Sandia National Laboratories developed Solar Thermal Energy Planner (STEP 1), a new web-based decision support tool for solar industrial process heat systems. At SolarPACES 2024, the STEP 1 tool was still under development; progress, methodologies, and a preliminary case study was presented. With the STEP 1 tool launch in May 2025, in this work, the initial version of the full public tool will be presented with demonstrations of its capabilities using a few case studies. First, the user's process heat needs such as location, process media (e.g., steam, air), process temperature, land availability, electricity and fuel costs, among other parameters. STEP 1 features a mapping interface that allows users to draw land and roof boundaries. The process media and temperature inform technology selection criteria modules that determine the appropriate solar thermal collection technologies, as well as congruent heat transfer media (e.g., hot water, oil, salt). Once the solar thermal technology selected, its nominal thermal production for the given site is characterized using NREL's System Advisor Model (SAM). Then, a modified version of NREL's REopt optimal sizing and dispatch optimization tool determines cost-optimal sizing. Within minutes, the user receives the results of the technoeconomics analysis, including the size and performance of the cost-optimal solar-plus-storage system. The cost of the system is compared to business-as-usual (e.g., an existing, standalone natural gas boiler). Users can download key results to store for sensitivity analyses. Examples of flat plate collector, parabolic trough, and molten salt tower applications with and without PV hybridization for different industrial facility types are presented in this work. The STEP 1 tool aims to reduce barriers to the adoption of solar heating solutions stemming from a lack of familiarity and technical background with solar system design options and costs among industry stakeholders.

14 SOLAR ENERGY↗

Modeling the decay of energy containing eddies: A source of solar wind heating

To understand the solar wind heating and acceleration mechanisms one needs to understand the decay of energy containing eddies. With this goal in mind, attempts have been made to extend the fluid dynamic phenomenology of large scale quasi-equilibrium to the case of magnetohydrodynamics. Matthaeus et al. have proposed a model for the inhomogeneous transport and decay of five mean variables, namely, two mean square Elsasser variables z(exp 2) (sub +/-) their correlation lengths, and the difference between the kinetic and magnetic energies. We test the validity of this model in the simplified case of homogeneous turbulence simulated in a periodic box. We propose a class of models and show that they may fit the simulation satisfactorily. Analytic solutions of this class of model reveal their inherent properties and demonstrate the difficulties associated with finite cross helicity. It is noted that adjustments are required to make the simplest models, which are based upon isotropic turbulence, scale properly with respect to the strength of the mean magnetic field. This can be interpreted as due to anisotropic turbulence, which can be modelled by simple parameterization in the phenomenology.

Hossain, M.↗

Controllable Solar Flux Heating for Freeze Recovery in Molten Salt Parabolic Trough Collectors

In molten-salt parabolic trough plants, the melting process is particularly important for freeze recovery of salt that is solidified in a collector loop, should such an event occur. Currently impedance heating is expected for freeze recovery of the collector loops, but this method can be expensive. Here, a lower-cost alternative is proposed to use controllable concentrated solar flux directly from the parabolic mirrors to thaw salt that is frozen in the collector. A computational fluid dynamics model was developed to explore the solidification and melting processes of molten salt in a parabolic trough receiver and to assess the viability of this concept. Results indicate that concentrated solar heating has the potential to melt frozen salt in 5.6 h, compared to that in 8.8 h for a 300 W m –1 impedance heating system. At the same time, controllable solar flux heating introduces nonuniform solar fluxes on the receiver surface, which can induce significant thermal stress on the receiver tube. A preliminary stress analysis indicates that the temperature difference across the receiver tube should be maintained below about 70 °C for heating up to 300 °C at internal pressures ≤10 bar. At these conditions, freeze recovery using solar flux heating will not significantly affect receiver lifetime. These results suggest that controllable solar flux heating could effectively supplement or replace impedance heating in the freeze recovery system. Incorporating this methodology in future parabolic trough concentrating solar power plants is an opportunity for capital and operational cost-savings.

14 SOLAR ENERGY↗

Solar Space Heating for Warehouse--Kansas City, Kansas

New report describes warehouse/office building in Kansas City, Kansas which uses solar heating for warehouse portion and conventional heating and cooling for office portion. Building is divided into 20 equal units, each with its own solar-heating system. Modular design enables multiple units to be combined to form offices or warehouses of various sizes as required by tenants.

Source record↗

Solar space heating for the Visitors Center, Stephens College, Columbia, Missouri

The solar energy system located at the Visitors' Center on the Stephens College Campus, Columbia, Missouri is discussed. The system is installed in a four-story, 15,000 square foot building. The solar energy system is an integral design of the building and utilizes 176 hydronic flat plate collectors which use a 50 percent water ethylene blycol solution and water-to-water heat exchanger. Solar heated water is stored in a 5,000 gallon water storage tank located in the basement equipment room. A natural gas fired hot water boiler supplies hot water when the solar energy heat supply fails to meet the demand. The designed solar contribution is 71 percent of the heating load.

Source record↗

Solar residential heating and cooling system development test program

A solar heating and cooling system is described, which was installed in a simulated home at Marshall Space Flight Center. Performance data are provided for the checkout and initial operational phase for key subsystems and for the total system. Valuable information was obtained with regard to operation of a solar cooling system during the first summer of operation. Areas where improvements and modifications are required to optimize such a system are discussed.

Humphries, W. R.↗

Study of Magnetic Motions in the Solar Photosphere and their Implications for Heating the Solar Atmosphere

We continued our program of CO observations with the McMath-Pierce facility at Kitt Peak National Solar Observatory. Uitenbroek has developed a two-and three dimensional radiative transfer code that now includes chemical equilibrium calculations. This code allows us to compute a CO spectrum from for instance a snapshot of a solar granulation simulation (e.g. Stein & Nordlund 1989, Apj 342, L95) and compare these theoretical spectra with our spatially resolved CO spectroscopy. Van Ballegooijen and Uitenbroek have started calculations of two-dimensional fluxtube models that account consistently for hydrogen ionization in the calculation of the electron density. To this end we solve radiative transfer for hydrogen (bound-bound and bound-free transitions) in the two-dimensional models, including the effect of partial frequency redistribution (PRD) in the Lyman (alpha) and (beta) lines. From our internally consistent models we will calculate emergent spectra and the way these vary with location of some well-known spectral diagnostics and compare our results with observed line profiles. We can readily compare theoretical CO profiles from out models with our spatially resolved CO observations. Also we can compare with spatially resolved Ca II (ground based) and Mg II (we have observations done with the UVSP/SMM instrument), and Lyman (alpha) observations that should be available from SUMER/SOHO.

Noyes, Robert W.↗

Experimental solar heating-cooling system model tests of a full-scale building system

An experimental solar heating and cooling system model has been built and operated, combining elements that are programmable - heating and/or cooling load of a building, collected solar energy - with experimental equipment. The system model was based on the loads and components used in the Solar Building Test Facility (SBTF) which includes a 1394 square meter solar collector field, at NASA-Langley. Operations covered 5 continuous days under summer conditions. For the system model, up to 55% of the simulated collected solar energy was used for the building load. This amount constituted 35% of the building cooling load. Heat loss was significant. If tank heat loss were eliminated, 75% of the collected solar energy would be used. This amount would supply approximately 50% of the building cooling load.

Namkoong, D.↗

Hybrid Solar Thermal Energy System for District Heating Application

Solar district heating (SDH) systems can be good alternatives to conventional systems when they are optimized with hybrid configurations and thermal energy storage (TES). In this scope, a hybrid renewable thermal energy system (RTES) model has been built combining flat plate collector (FPC) solar system with parabolic trough collector (PTC) system via a heat exchanger and coupled with TES. To undertake the hybridization of the system, System Advisor Model (SAM) software was modified, which allowed control over configurations and more accurate modelling of heat transfer between the collectors. The model is first compared to an existing hybrid solar district heating systems (DHS) system in Taars, Denmark. The results showed a good correlation with an overestimation of only 6.4% compared to most recent heat output. Then the same system configuration was modeled in different geographic locations to investigate the impact of changes in direct normal irradiance (DNI) to the heat sink thermal output of the hybrid system. The results showed that the annual net thermal power output in California, USA can be three times more than the annual net thermal power output in Taars, Denmark. Finally, multiple hybrid configurations with varying solar field sizes were simulated based on the heat demand of two different university campuses DHS. The results showed that, retrofit applications of this hybrid DHS system coupled with TES could reduce the natural gas consumption of the existing systems between 25% and 41%. The use of hybrid RTES highlighted in this paper can be extended to many more opportunities.

district heating↗

Results of heating mode performance tests of a solar-assisted heat pump

The performance of a heat pump, utilizing 8.16 square meters of low-cost solar collectors as the evaporator in a Freon-114 refrigeration cycle, was determined under actual insolation conditions during the summer and fall of 1976. C.O.P.'s (coefficient of performance) greater than 3 were obtained with condensing temperatures around 78 C and evaporating temperatures around 27 C. Ambient temperatures were about 3 C above evaporating temperatures. Similar performance levels were obtained at other insolation and temperature conditions. Experience with the system has identified some component and system changes which should increase the obtainable C.O.P. to about 4.0. These are described along with the system's design rationale. The accumulated data are presented as an appendix.

Jones, C. B.↗