SU-E-J-42: Customized Deformable Image Registration Using Open-Source Software SlicerRT

Purpose: SlicerRT is a flexible platform that allows the user to incorporate the necessary images registration and processing tools to improve clinical workflow. This work validates the accuracy and the versatility of the deformable image registration algorithm of the free open-source software SlicerRT using a deformable physical pelvic phantom versus available commercial image fusion algorithms. Methods: Optical camera images of nonradiopaque markers implanted in an anatomical pelvic phantom were used to measure the ground-truth deformation and evaluate the theoretical deformations for several DIR algorithms. To perform the registration, full and empty bladder computed tomography (CT) images of the phantom were obtained and used as fixed and moving images, respectively. The DIR module, found in SlicerRT, used a B-spline deformable image registration with multiple optimization parameters that allowed customization of the registration including a regularization term that controlled the amount of local voxel displacement. The virtual deformation field at the center of the phantom was obtained and compared to the experimental ground-truth values. The parameters of SlicerRT were then varied to improve spatial accuracy. To quantify image similarity, the mean absolute difference (MAD) parameter using Hounsfield units was calculated. In addition, the Dice coefficient of the contoured rectum was evaluated to validate the strength of the algorithm to transfer anatomical contours. Results: Overall, SlicerRT achieved one of the lowest MAD values across the algorithm spectrum, but slightly smaller mean spatial errors in comparison to MIM software (MIM). On the other hand, SlicerRT created higher mean spatial errors than Velocity Medical Solutions (VEL), although obtaining an improvement on the DICE to 0.91. The large spatial errors were attributed to the poor contrast in the prostate bladder interface of the phantom. Conclusion: Based phantom validation, SlicerRT is capable of achieving comparable DIR accuracy to commercial programs such as MIM and VEL.

60 APPLIED LIFE SCIENCES↗

Software Quality Assurance for EBR-II Fuels Irradiation and Physics Database (FIPD)

The Fuels Irradiation and Physics Database (FIPD) is an ongoing DOE project on archival of the EBR-II metal-alloy fuel irradiation experiments. As part of its use in support of license applications, the Quality Assurance Program Plan (QAPP) was drafted and endorsed by NRC in an effort to demonstrate its compliance with regulatory expectations. Software Quality Assurance (SQA) for the physics portion of FIPD is intended to qualify the calculated quantities such as fuel and cladding temperatures, neutron fluence and axially varying burnup estimates for irradiated fuel elements. This report covers the initial evaluation of SQA status of three neutron physics and thermo-fluid codes (REBUS, RCT and SE2RCT) that form the basis of calculated quantities for as-irradiated characteristics of the tested metallic fuel elements. The report also introduces an SQA plan to address the identified deficiencies. The REBUS, RCT, and SE2RCT codes are all part of the Argonne Reactor Code (ARC) code system. There is considerable knowledge and experience on REBUS and RCT but relatively less on SE2RCT. During FY2021, efforts focused on an assessment of how the data in the EBR-II Physics and Analysis DataBase (PADB) is generated with SE2RCT and used in FIPD. Additional tasks included considerations of uncertainties for power estimates in REBUS and RCT calculations and their impact on the combined RCT methodology. The RCT software usage in FIPD was assessed this year and the input/output details studied. A “requirements” document was created that identifies the key features of the RCT software being used in FIPD that need to have SQA documentation. A brief discussion on the history of RCT and its input is included in this report along with the basic SQA roadmap laid out in the requirements document. The SE2RCT software usage in FIPD is still being studied noting that there is no current manual. As part of the work done this year, two bugs were identified in the SE2RCT software which have a minor impact on the accuracy of the results it produces. No requirements document has been created, but one identified feature of SE2RCT being used that needs verification was its fuel pin temperature calculation. The work completed this year confirms that the approximations which will be included in the software verification report for SE2RCT are accurate. In addition to software quality assurance work for RCT and SE2RCT, an automated verification framework is proposed to simplify the software quality assurance process. The purpose of this framework is to streamline code verification and documentation while minimizing repetitive tasks for code developers and reviewers. The reduction of repeated input (between reference solution, software, and documentation input) throughout the SQA process reduces potential for human errors during the preparation of the supporting software quality records. The automation of the verification and documentation process proposed for this project leverages the existing verification structure already in place for the SAS4A/SASSYS-1 code.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Star tracker error analysis: Roll-to-pitch nonorthogonality

An error analysis is described on an anomaly isolated in the star tracker software line of sight (LOS) rate test. The LOS rate cosine was found to be greater than one in certain cases which implied that either one or both of the star tracker measured end point unit vectors used to compute the LOS rate cosine had lengths greater than unity. The roll/pitch nonorthogonality matrix in the TNB CL module of the IMU software is examined as the source of error.

Corson, R. W.↗

Standards for Evaluating Radiosonde Measurements

Radiosonde measurement errors occur for various reasons: calibration, mishandling of sensors, poor software, radiation, etc. It is important that these errors be found and corrected, or at the least, corrections determined that might be sensibly applied. Radiation errors apparently are the most serious since the lack of radiative equilibrium between the thermistor and its surrounding environment can not be corrected for just a single thermistor without serious intervention. However, errors may be determined using the Accurate Temperature Measuring (ATM) radiosonde. The ATM radiosonde development was initiated in the mid-1980's using three thermistors; five thermistors are presently incorporated in the ATM radiosonde. Test flights at different locations indicated that the radiative effect on the thermistor varies because of the different environment of each location and, can be corrected. When comparisons between different thermistors (radiosondes) are required the ATM is a valuable tool. Investigation of relative humidity measurements is an ongoing issue because of large discrepancies in observed data. The first chilled mirror (SNOW WHITE) radiosonde was flown from Wallops Flight Facility in 1997. Tests and analyses show the chilled mirror radiosonde present very acceptable data up to the altitude of the tropopause and in some measurements, to 100 hPA. Improvement and better interpretation of the measurements are important. Discussion concentrates on new aspects of the ATM radiosonde application and the utility of the chilled mirror radiosonde.

Schmidlin, F. J.↗

Evaluating Operating System Vulnerability to Memory Errors

Reliability is of great concern to the scalability of extreme-scale systems. Of particular concern are soft errors in main memory, which are a leading cause of failures on current systems and are predicted to be the leading cause on future systems. While great effort has gone into designing algorithms and applications that can continue to make progress in the presence of these errors without restarting, the most critical software running on a node, the operating system (OS), is currently left relatively unprotected. OS resiliency is of particular importance because, though this software typically represents a small footprint of a compute node's physical memory, recent studies show more memory errors in this region of memory than the remainder of the system. In this paper, we investigate the soft error vulnerability of two operating systems used in current and future high-performance computing systems: Kitten, the lightweight kernel developed at Sandia National Laboratories, and CLE, a high-performance Linux-based operating system developed by Cray. For each of these platforms, we outline major structures and subsystems that are vulnerable to soft errors and describe methods that could be used to reconstruct damaged state. Our results show the Kitten lightweight operating system may be an easier target to harden against memory errors due to its smaller memory footprint, largely deterministic state, and simpler system structure.

99 GENERAL AND MISCELLANEOUS↗

A qualitative assessment of current CCF guidance based on a review of safety system digital implementation changes with evolving technology - 148

This paper is a summary of a study performed in support of the US Nuclear Regulatory Commission (NRC) to evaluate current policy on software common-cause failure (CCF). The study reported in this paper is one of several that contributed to the technical basis to inform NRC staff. The study first reviewed policies and assessment guidance as discussed in the Staff Requirements Memorandum to the Secretary of the Commission, Office of the NRC (SECY) 93-087, Policy, Technical, and Licensing Issues Pertaining to Evolutionary and Advanced Light Water Reactor (ALWR) Designs, and Branch Technical Position (BTP) 7-19, Guidance on Evaluation of Defense-in-Depth and Diversity in Digital Computer-Based Instrumentation and Control Systems, as well as Chapter 7, 'Instrumentation and Controls', in NUREG-0800, Standard Review Plan for Review of Safety Analysis Reports for Nuclear Power Plants. The study then examined instrumentation and controls (I and C) technology implementations in nuclear power plants in the light of current CCF guidance. The intent was to assess whether the current position on CCF remains appropriate given the evolutions in digital safety system implementations and, if gaps in the guidance were found, to provide recommendations as to how these gaps could be closed. The methodology adopted was to review the vendors' technology and software implementation processes for digital safety systems as technology evolved. The following three representative safety systems were selected to provide illustrative examples: - Eagle 21 was selected to represent vintage microprocessor-based technology used from the 1980's to mid-1990's, - TELEPERM XS (TXS) was selected to represent second generation microprocessor-based technology used from the mid-1990's to the 2000's, and - The advanced logic system (ALS) was selected to represent the latest trend of using technology based on field programmable gate arrays (FPGAs). Technology implementations were reviewed in light of the basic premise of the NRC in BTP 7-19 (Revision 6), that software-based or software-logic-based digital system development errors are a credible source of CCF and therefore are susceptible to CCF because identical copies of the software-based logic and architecture are present in redundant divisions of safety-related systems. BTP 7-19 categorizes firmware and logic developed from software-based development systems all under software. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Error Analysis of the Shuttle Orbital Maneuvering System P-V-T Propellant Gaging Module. Mission Planning, Mission Analysis and Software Formulation

An investigation of the shuttle orbital maneuvering system (OMS) pressure-volume-temperature (P-V-T) propellant gaging module has revealed that the gaging errors due to the combined effects of random instrumentation measurement errors, propellant loading uncertainties, and simplifying assumptions in the software are non-linear over the range of the usable propellant quantity gage (0-100%), with the largest error being at the zero point. When the OMS propellant tanks in the orbiter vehicle pods are filled to contain 100% of the maximum usable propellant, the gaging error at the zero point was determined to be 9.5% for the fuel and 9.5% for the oxidizer. When the OMS propellant tanks initially contain 50% of the maximum usable propellant, the largest gaging error is still 9.5% for the fuel and 9.5% for the oxidizer.

Duhon, D. D.↗

Health Monitor for Multitasking, Safety-Critical, Real-Time Software

Health Manager can detect Bad Health prior to a failure occurring by periodically monitoring the application software by looking for code corruption errors, and sanity-checking each critical data value prior to use. A processor s memory can fail and corrupt the software, or the software can accidentally write to the wrong address and overwrite the executing software. This innovation will continuously calculate a checksum of the software load to detect corrupted code. This will allow a system to detect a failure before it happens. This innovation monitors each software task (thread) so that if any task reports "bad health," or does not report to the Health Manager, the system is declared bad. The Health Manager reports overall system health to the outside world by outputting a square wave signal. If the square wave stops, this indicates that system health is bad or hung and cannot report. Either way, "bad health" can be detected, whether caused by an error, corrupted data, or a hung processor. A separate Health Monitor Task is started and run periodically in a loop that starts and stops pending on a semaphore. Each monitored task registers with the Health Manager, which maintains a count for the task. The registering task must indicate if it will run more or less often than the Health Manager. If the task runs more often than the Health Manager, the monitored task calls a health function that increments the count and verifies it did not go over max-count. When the periodic Health Manager runs, it verifies that the count did not go over the max-count and zeroes it. If the task runs less often than the Health Manager, the periodic Health Manager will increment the count. The monitored task zeroes the count, and both the Health Manager and monitored task verify that the count did not go over the max-count.

Zoerner, Roger↗

Digital X-ray Pipe Inspector Software

The Digital X-ray Pipe Inspector software requires a digital x-ray image of a pipe as input to the program, such as the image in Attachment A Figure 1. The image may be in a variety of software formats such as bitmap, jpeg, tiff, DICOM or DICONDE. The software allows the user to interactively select a region of interest from the image for analysis. This software is used to analyze digital x-ray images of pipes to evaluate loss of wall thickness. The software specifically provides tools to analyze the image in (a) the pipe walls, (b) between the pipe walls. Traditional software uses only the information at the pipe wall while this new software also evaluates the image between the pipewalls. This makes the inspection process faster, more thorough, more efficient, and reduces expensive reshots. Attachment A Figure 2 shows a region of interest (a green box) drawn by the user around an anomaly in the pipe wall. This area is automatically analyzed by the external pipe wall tool with the result shown in Attachment A Figure 3. The edges of the pipe wall are detected and highlighted in yellow and areas where the wall thickness in less the the minimum wall threshold are shown in red. These measurements are typically made manually in other software programs, which lead to errors and inconsistency because the location of the edges are estimated by the user. Attachment A Figure 4 shows a region of interest (a green box) drawn by the user between the pipe walls. As can be seen there are intensity anomalies that correspond to wall defects. However, this information is not used directly by other software programs. In order to fully investigate these anomalies, the pipe would be reinspected in a different orientation to attempt to obtain a view of the anomaly in the pipe wall rather than the interior of the pipe. The pipe may need to be x-rayed a number of times to obtain the correct orientation. This is very costly and time consuming. The new software can perform the analysis directly on the intensity information in the original image. Figures 5 through 9 in Attachment A show wall defects in red for various percents of wall thickness loss. For example, Figure 5 show defects (in red) where the wall thickness is 95% or less than the nominal wall thickness (or a 5% or greater wall thickness loss). Wall thicknesses can be given in absolute terms as well.

Gibbs, Kenneth M.↗

Planned LMSS propagation experiment using ACTS: Preliminary antenna pointing results during mobile operations

An overview and a status description of the planned LMSS mobile K band experiment with ACTS is presented. As a precursor to the ACTS mobile measurements at 20.185 GHz, measurements at 19.77 GHz employing the Olympus satellite were originally planned. However, because of the demise of Olympus in June of 1991, the efforts described here are focused towards the ACTS measurements. In particular, we describe the design and testing results of a gyro controlled mobile-antenna pointing system. Preliminary pointing measurements during mobile operations indicate that the present system is suitable for measurements employing a 15 cm aperture (beamwidth at approximately 7 deg) receiving antenna operating with ACTS in the high gain transponder mode. This should enable measurements with pattern losses smaller than plus or minus 1 dB over more than 95 percent of the driving distance. Measurements with the present mount system employing a 60 cm aperture (beamwidth at approximately 1.7 deg) results in pattern losses smaller than plus or minus 3 dB for 70 percent of the driving distance. Acceptable propagation measurements may still be made with this system by employing developed software to flag out bad data points due to extreme pointing errors. The receiver system including associated computer control software has been designed and assembled. Plans are underway to integrate the antenna mount with the receiver on the University of Texas mobile receiving van and repeat the pointing tests on highways employing a recently designed radome system.

Rowland, John R.↗

SPICE Module for the Satellite Orbit Analysis Program (SOAP)

A SPICE module for the Satellite Orbit Analysis Program (SOAP) precisely represents complex motion and maneuvers in an interactive, 3D animated environment with support for user-defined quantitative outputs. (SPICE stands for Spacecraft, Planet, Instrument, Camera-matrix, and Events). This module enables the SOAP software to exploit NASA mission ephemeris represented in the JPL Ancillary Information Facility (NAIF) SPICE formats. Ephemeris types supported include position, velocity, and orientation for spacecraft and planetary bodies including the Sun, planets, natural satellites, comets, and asteroids. Entire missions can now be imported into SOAP for 3D visualization, playback, and analysis. The SOAP analysis and display features can now leverage detailed mission files to offer the analyst both a numerically correct and aesthetically pleasing combination of results that can be varied to study many hypothetical scenarios. The software provides a modeling and simulation environment that can encompass a broad variety of problems using orbital prediction. For example, ground coverage analysis, communications analysis, power and thermal analysis, and 3D visualization that provide the user with insight into complex geometric relations are included. The SOAP SPICE module allows distributed science and engineering teams to share common mission models of known pedigree, which greatly reduces duplication of effort and the potential for error. The use of the software spans all phases of the space system lifecycle, from the study of future concepts to operations and anomaly analysis. It allows SOAP software to correctly position and orient all of the principal bodies of the Solar System within a single simulation session along with multiple spacecraft trajectories and the orientation of mission payloads. In addition to the 3D visualization, the user can define numeric variables and x-y plots to quantitatively assess metrics of interest.

Coggi, John↗

Closed-Loop Analysis of Soft Decisions for Serial Links

Modern receivers are providing soft decision symbol synchronization as radio links are challenged to push more data and more overhead through noisier channels, and software-defined radios use error-correction techniques that approach Shannon s theoretical limit of performance. The authors describe the benefit of closed-loop measurements for a receiver when paired with a counterpart transmitter and representative channel conditions. We also describe a real-time Soft Decision Analyzer (SDA) implementation for closed-loop measurements on single- or dual- (orthogonal) channel serial data communication links. The analyzer has been used to identify, quantify, and prioritize contributors to implementation loss in real-time during the development of software defined radios.

Lansdowne, Chatwin A.↗

Software Development Technologies for Reactive, Real-Time, and Hybrid Systems

The research is directed towards the design and implementation of a comprehensive deductive environment for the development of high-assurance systems, especially reactive (concurrent, real-time, and hybrid) systems. Reactive systems maintain an ongoing interaction with their environment, and are among the most difficult to design and verify. The project aims to provide engineers with a wide variety of tools within a single, general, formal framework in which the tools will be most effective. The entire development process is considered, including the construction, transformation, validation, verification, debugging, and maintenance of computer systems. The goal is to automate the process as much as possible and reduce the errors that pervade hardware and software development.

Manna, Zohar↗

Scripting in Radiation Therapy: An Automatic 3D Beam-Naming System

Scripts can be executed within the radiation treatment planning software framework to reduce human error, increase treatment planning efficiency, reduce confusion, and promote consistency within an institution or even among institutions. Scripting is versatile, and one application is an automatic 3D beam-naming system that describes the position of the beam relative to the patient in 3D space. The naming system meets the need for nomenclature that is conducive for clear and accurate communication of beam entry relative to patient anatomy. In radiation oncology in particular, where miscommunication can cause significant harm to patients, a system that minimizes error is essential. Frequent sharing of radiation treatment information occurs not only among members within a department but also between different treatment centers. Descriptions of treatment beams are perhaps the most commonly shared information about a patient's course of treatment in radiation oncology. Automating the naming system by the use of a script reduces the potential for human error, improves efficiency, enforces consistency, and would allow an institution to convert to a new naming system with greater ease. This script has been implemented in the Department of Radiation Oncology at the University of Washington Medical Center since December 2009. It is currently part of the dosimetry protocol and is accessible by medical dosimetrists, radiation oncologists, and medical physicists. This paper highlights the advantages of using an automatic 3D beam-naming script to flawlessly and quickly identify treatment beams with unique names. Scripting in radiation treatment planning software has many uses and great potential for improving clinical care.

61 RADIATION PROTECTION AND DOSIMETRY↗

ANOPP programmer's reference manual for the executive System

Documentation for the Aircraft Noise Prediction Program as of release level 01/00/00 is presented in a manual designed for programmers having a need for understanding the internal design and logical concepts of the executive system software. Emphasis is placed on providing sufficient information to modify the system for enhancements or error correction. The ANOPP executive system includes software related to operating system interface, executive control, and data base management for the Aircraft Noise Prediction Program. It is written in Fortran IV for use on CDC Cyber series of computers.

Gillian, R. E.↗

Fault Mitigation Schemes for Future Spaceflight Multicore Processors

Future planetary exploration missions demand significant advances in on-board computing capabilities over current avionics architectures based on a single-core processing element. The state-of-the-art multi-core processor provides much promise in meeting such challenges while introducing new fault tolerance problems when applied to space missions. Software-based schemes are being presented in this paper that can achieve system-level fault mitigation beyond that provided by radiation-hard-by-design (RHBD). For mission and time critical applications such as the Terrain Relative Navigation (TRN) for planetary or small body navigation, and landing, a range of fault tolerance methods can be adapted by the application. The software methods being investigated include Error Correction Code (ECC) for data packet routing between cores, virtual network routing, Triple Modular Redundancy (TMR), and Algorithm-Based Fault Tolerance (ABFT). A robust fault tolerance framework that provides fail-operational behavior under hard real-time constraints and graceful degradation will be demonstrated using TRN executing on a commercial Tilera(R) processor with simulated fault injections.

software based↗

Diode laser spectrometer for high-precision measurements

The issues of the development, calibration and putting into operation of a diode laser spectrometer for high-precision measurements are considered. The tests rely on the use of an isolated P20 line of the 00031 – 00001 band of the {sup 12}C{sup 16}O{sub 2} molecule. The spectrometer error budget is analysed. A software programme for the approximation of a spectral line contour is designed and the procedure is analysed. It is shown that, for a baseline with a relative level of 2.3 × 10{sup −5}, it is optimal to use no more than six fitting parameters in the line contour approximation. The measured integral intensity of the analytical line constitutes 5.3865(85) × 10{sup −23} cm per molecule. (laser spectroscopy)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

(abstract) Formal Inspection Technology Transfer Program

A Formal Inspection Technology Transfer Program, based on the inspection process developed by Michael Fagan at IBM, has been developed at JPL. The goal of this program is to support organizations wishing to use Formal Inspections to improve the quality of software and system level engineering products. The Technology Transfer Program provides start-up materials and assistance to help organizations establish their own Formal Inspection program. The course materials and certified instructors associated with the Technology Transfer Program have proven to be effective in classes taught at other NASA centers as well as at JPL. Formal Inspections (NASA tailored Fagan Inspections) are a set of technical reviews whose objective is to increase quality and reduce the cost of software development by detecting and correcting errors early. A primary feature of inspections is the removal of engineering errors before they amplify into larger and more costly problems downstream in the development process. Note that the word 'inspection' is used differently in software than in a manufacturing context. A Formal Inspection is a front-end quality enhancement technique, rather than a task conducted just prior to product shipment for the purpose of sorting defective systems (manufacturing usage). Formal Inspections are supporting and in agreement with the 'total quality' approach being adopted by many NASA centers.

certified instructors Formal Inspections↗