Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Software Quality Assurance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Clinical Outcome Metrics for Optimization of Robust Training

Introduction: The emphasis of this research is on the Human Research Program (HRP) Exploration Medical Capability's (ExMC) "Risk of Unacceptable Health and Mission Outcomes Due to Limitations of In-Flight Medical Capabilities." Specifically, this project aims to contribute to the closure of gap ExMC 2.02: We do not know how the inclusion of a physician crew medical officer quantitatively impacts clinical outcomes during exploration missions. The experiments are specifically designed to address clinical outcome differences between physician and non-physician cohorts in both near-term and longer-term (mission impacting) outcomes. Methods: Medical simulations will systematically compare success of individual diagnostic and therapeutic procedure simulations performed by physician and non-physician crew medical officer (CMO) analogs using clearly defined short-term (individual procedure) outcome metrics. In the subsequent step of the project, the procedure simulation outcomes will be used as input to a modified version of the NASA Integrated Medical Model (IMM) to analyze the effect of the outcome (degree of success) of individual procedures (including successful, imperfectly performed, and failed procedures) on overall long-term clinical outcomes and the consequent mission impacts. The procedures to be simulated are endotracheal intubation, fundoscopic examination, kidney/urinary ultrasound, ultrasound-guided intravenous catheter insertion, and a differential diagnosis exercise. Multiple assessment techniques will be used, centered on medical procedure simulation studies occurring at 3, 6, and 12 months after initial training (as depicted in the following flow diagram of the experiment design). Discussion: Analysis of procedure outcomes in the physician and non-physician groups and their subsets (tested at different elapsed times post training) will allow the team to 1) define differences between physician and non-physician CMOs in terms of both procedure performance (pre-IMM analysis) and overall mitigation of the mission medical impact (IMM analysis); 2) refine the procedure outcome and clinical outcome metrics themselves; 3) refine or develop innovative medical training products and solutions to maximize CMO performance; and 4) validate the methods and products of this experiment for operational use in the planning, execution, and quality assurance of the CMO training process The team has finalized training protocols and developed a software training/testing tool in collaboration with Butler Graphics (Detroit, MI). In addition to the "hands on" medical procedure modules, the software includes a differential diagnosis exercise (limited clinical decision support tool) to evaluate the diagnostic skills of participants. Human subject testing will occur over the next year.

Ebert, D.↗

Software reliability models for fault-tolerant avionics computers and related topics

Software reliability research is briefly described. General research topics are reliability growth models, quality of software reliability prediction, the complete monotonicity property of reliability growth, conceptual modelling of software failure behavior, assurance of ultrahigh reliability, and analysis techniques for fault-tolerant systems.

Miller, Douglas R.↗

Fiducial-Based Translational Localization Accuracy of Electromagnetic Tracking System and On-Board Kilovoltage Imaging System

Purpose: The Calypso medical four-dimensional localization system uses AC electromagnetics, which do not require ionizing radiation, for accurate, real-time tumor tracking. This investigation compared the static and dynamic tracking accuracy of this system to that of an on-board imaging kilovoltage X-ray system for concurrent use of the two systems. Methods and Materials: The localization accuracies of a kilovoltage imaging system and a continuous electromagnetic tracking system were compared. Using an in-house developed four-dimensional stage, quality-assurance fixture containing three radiofrequency transponders was positioned at a series of static locations and then moved through the ellipsoidal and nonuniform continuous paths. The transponder positions were tracked concurrently by the Calypso system. For static localization, the transponders were localized using portal images and digitally reconstructed radiographs by commercial matching software. For dynamic localization, the transponders were fluoroscopically imaged, and their positions were determined retrospectively using custom-written image processing programs. The localization data sets were synchronized with and compared to the known quality assurance fixture positions. The experiment was repeated to retrospectively track three transponders implanted in a canine lung. Results: The root mean square error of the on-board imaging and Calypso systems was 0.1 cm and 0.0 cm, respectively, for static localization, 0.22 mm and 0.33 mm for dynamic phantom positioning, and 0.42 mm for the canine study. Conclusion: The results showed that both localization systems provide submillimeter accuracy. The Calypso and on-board imaging tracking systems offer distinct sets of advantages and, given their compatibility, patients could benefit from the complementary nature of the two systems when used concurrently.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Validation of software releases for CMS

The CMS software stack currently consists of more than 2 Million lines of code developed by over 250 authors with a new version being released every week. CMS has setup a release validation process for quality assurance which enables the developers to compare to previous releases and references. This process provides the developers with reconstructed datasets of real data and MC samples. The samples span the whole range of detector effects and important physics signatures to benchmark the performance of the software. They are used to investigate interdependency effects of software packages and to find and fix bugs. The samples have to be available in a very short time after a release is published to fit into the streamlined CMS development cycle. The standard CMS processing infrastructure and dedicated resources at CERN and FNAL are used to achieve a very short turnaround of 24 hours. The here described release validation process is an integral part of CMS software development and contributes significantly to ensure stable production and analysis. It's success emphasizes the importance of a streamlined release validation process for projects with a large code basis and significant number of developers and can function as an example for future projects.

99 GENERAL AND MISCELLANEOUS↗

Leveraging The Open Provenance Model as a Multi-Tier Model for Global Climate Research

Global climate researchers rely upon many forms of sensor data and analytical methods to help profile subtle changes in climate conditions. The U.S. Department of Energy's Atmospheric Radiation Measurement (ARM) program provides researchers with curated Value Added Products (VAPs) resulting from continuous sensor data streams, data fusion, and modeling. The ARM operations staff and software development teams (data producers) rely upon a number of techniques to ensure strict quality control (QC) and quality assurance (QA) standards are maintained. Climate researchers (data consumers) are highly interested in obtaining as much provenance (data quality, data pedigree) as possible to establish data trustworthiness. Currently all the provenance is not easily attainable or identifiable without significant efforts to extract and piece together information from configuration files, log files, codes, and status information from ARM databases. The need for a formalized approach to managing provenance became paramount with the planned addition of 120 new instruments, new data products, and data collection scaling to half a terabyte daily. Last year our research identified the need for a multi-tier provenance model to enable the data consumer easy access to the provenance for their data. This year we are leveraging the Open Provenance Model as a foundational construct that serves the needs of both the VAP producers and consumers, we are organizing the provenance in different tiers of granularity to model VAP lineage, causality at the component level within a VAP, and the causality for each time step as samples are being assembled within the VAP. This paper shares our implementation strategy and how the ARM operations staff and the climate research community can greatly benefit from this approach to more effectively assess and quantify VAP provenance.

54 ENVIRONMENTAL SCIENCES↗

Sci-Thur AM: YIS – 08: Automated Imaging Quality Assurance for Image-Guided Small Animal Irradiators

Purpose: To develop quality assurance (QA) standards and tolerance levels for image quality of small animal irradiators. Methods: A fully automated in-house QA software for image analysis of a commercial microCT phantom was created. Quantitative analyses of CT linearity, signal-to-noise ratio (SNR), uniformity and noise, geometric accuracy, modulation transfer function (MTF), and CT number evaluation was performed. Phantom microCT scans from seven institutions acquired with varying parameters (kVp, mA, time, voxel size, and frame rate) and five irradiator units (Xstrahl SARRP, PXI X-RAD 225Cx, PXI X-RAD SmART, GE explore CT/RT 140, and GE Explore CT 120) were analyzed. Multi-institutional data sets were compared using our in-house software to establish pass/fail criteria for each QA test. Results: CT linearity (R2>0.996) was excellent at all but Institution 2. Acceptable SNR (>35) and noise levels (<55HU) were obtained at four of the seven institutions, where failing scans were acquired with less than 120mAs. Acceptable MTF (>1.5 lp/mm for MTF=0.2) was obtained at all but Institution 6 due to the largest scan voxel size (0.35mm). The geometric accuracy passed (<1.5%) at five of the seven institutions. Conclusion: Our QA software can be used to rapidly perform quantitative imaging QA for small animal irradiators, accumulate results over time, and display possible changes in imaging functionality from its original performance and/or from the recommended tolerance levels. This tool will aid researchers in maintaining high image quality, enabling precise conformal dose delivery to small animals.

60 APPLIED LIFE SCIENCES↗

PVAnalytics: A Python Package for Automated Processing of Solar Time Series Data

Multiple publicly available software packages exist that analyze solar time series data, including RdTools and Solar Data Tools, among others. Several of these packages contain their own unique quality assurance (QA) and feature recognition algorithms. The python PVAnalytics package was developed to offer an internally consistent source for these analysis tools, making it easier for the end user to deploy these routines on his or her solar data. The PVAnalytics package currently contains routines for outlier detection, inverter clipping detection, irradiance and temperature checks, orientation checks, and data shift detection, among other functions. These functions have been aggregated from various sources including Solar Forecast Arbiter, RdTools, and the QA process developed by NREL's PV Fleets Initiative. We are continuously adding new functionality to the package, including documentation, examples and algorithms. By bundling QA functionality into a single software package, we hope to make PVAnalytics a comprehensive software library to support analysis of solar metadata and time series data.

data cleaning↗

Extended Testability Analysis Tool

The Extended Testability Analysis (ETA) Tool is a software application that supports fault management (FM) by performing testability analyses on the fault propagation model of a given system. Fault management includes the prevention of faults through robust design margins and quality assurance methods, or the mitigation of system failures. Fault management requires an understanding of the system design and operation, potential failure mechanisms within the system, and the propagation of those potential failures through the system. The purpose of the ETA Tool software is to process the testability analysis results from a commercial software program called TEAMS Designer in order to provide a detailed set of diagnostic assessment reports. The ETA Tool is a command-line process with several user-selectable report output options. The ETA Tool also extends the COTS testability analysis and enables variation studies with sensor sensitivity impacts on system diagnostics and component isolation using a single testability output. The ETA Tool can also provide extended analyses from a single set of testability output files. The following analysis reports are available to the user: (1) the Detectability Report provides a breakdown of how each tested failure mode was detected, (2) the Test Utilization Report identifies all the failure modes that each test detects, (3) the Failure Mode Isolation Report demonstrates the system s ability to discriminate between failure modes, (4) the Component Isolation Report demonstrates the system s ability to discriminate between failure modes relative to the components containing the failure modes, (5) the Sensor Sensor Sensitivity Analysis Report shows the diagnostic impact due to loss of sensor information, and (6) the Effect Mapping Report identifies failure modes that result in specified system-level effects.

Melcher, Kevin↗

Efforts to enhance reproducibility in a human performance research project

Background: Ensuring the validity of results from funded programs is a critical concern for agencies that sponsor biological research. In recent years, the open science movement has sought to promote reproducibility by encouraging sharing not only of finished manuscripts but also of data and code supporting their findings. While these innovations have lent support to third-party efforts to replicate calculations underlying key results in the scientific literature, fields of inquiry where privacy considerations or other sensitivities preclude the broad distribution of raw data or analysis may require a more targeted approach to promote the quality of research output. Methods: We describe efforts oriented toward this goal that were implemented in one human performance research program, Measuring Biological Aptitude, organized by the Defense Advanced Research Project Agency's Biological Technologies Office. Our team implemented a four-pronged independent verification and validation (IV&V) strategy including 1) a centralized data storage and exchange platform, 2) quality assurance and quality control (QA/QC) of data collection, 3) test and evaluation of performer models, and 4) an archival software and data repository. Results: Our IV&V plan was carried out with assistance from both the funding agency and participating teams of researchers. QA/QC of data acquisition aided in process improvement and the flagging of experimental errors. Holdout validation set tests provided an independent gauge of model performance. Conclusions: In circumstances that do not support a fully open approach to scientific criticism, standing up independent teams to cross-check and validate the results generated by primary investigators can be an important tool to promote reproducibility of results.

59 BASIC BIOLOGICAL SCIENCES↗

SU-E-J-47: Development of a High-Precision, Image-Guided Radiotherapy, Multi- Purpose Radiation Isocenter Quality-Assurance Calibration and Checking System

Purpose: To develop a system that can define the radiation isocenter and correlate this information with couch coordinates, laser alignment, optical distance indicator (ODI) settings, optical tracking system (OTS) calibrations, and mechanical isocenter walkout. Methods: Our team developed a multi-adapter, multi-purpose quality assurance (QA) and calibration device that uses an electronic portal imaging device (EPID) and in-house image-processing software to define the radiation isocenter, thereby allowing linear accelerator (Linac) components to be verified and calibrated. Motivated by the concept that each Linac component related to patient setup for image-guided radiotherapy based on cone-beam CT should be calibrated with respect to the radiation isocenter, we designed multiple concentric adapters of various materials and shapes to meet the needs of MV and KV radiation isocenter definition, laser alignment, and OTS calibration. The phantom's ability to accurately define the radiation isocenter was validated on 4 Elekta Linacs using a commercial ball bearing (BB) phantom as a reference. Radiation isocenter walkout and the accuracy of couch coordinates, ODI, and OTS were then quantified with the device. Results: The device was able to define the radiation isocenter within 0.3 mm. Radiation isocenter walkout was within ±1 mm at 4 cardinal angles. By switching adapters, we identified that the accuracy of the couch position digital readout, ODI, OTS, and mechanical isocenter walkout was within sub-mm. Conclusion: This multi-adapter, multi-purpose isocenter phantom can be used to accurately define the radiation isocenter and represents a potential paradigm shift in Linac QA. Moreover, multiple concentric adapters allowed for sub-mm accuracy for the other relevant components. This intuitive and user-friendly design is currently patent pending.

07 ISOTOPE AND RADIATION SOURCES↗

Benefits and Challenges of Model-based Software Engineering: Lessons Learned based on Qualitative and Quantitative Findings

Even though Model-based Software Engineering (MBSwE) techniques and Autogenerated Code (AGC) have been increasingly used to produce complex software systems, there is only anecdotal knowledge about the state-of-thepractice. Furthermore, there is a lack of empirical studies that explore the potential quality improvements due to the use of these techniques. This paper presents in-depth qualitative findings about development and Software Assurance (SWA) practices and detailed quantitative analysis of software bug reports of a NASA mission that used MBSwE and AGC. The mission’s flight software is a combination of handwritten code and AGC developed by two different approaches: one based on state chart models (AGC-M) and another on specification dictionaries (AGC-D). The empirical analysis of fault proneness is based on 380 closed bug reports created by software developers. Our main findings include: (1) MBSwE and AGC provide some benefits, but also impose challenges. (2) SWA done only at a model level is not sufficient. AGC code should also be tested and the models and AGC should always be kept in-sync. AGC must not be changed manually. (3) Fixes made to address an individual bug report were spread both across multiple modules and across multiple files. On average, for each bug report 1.4 modules, that is, 3.4 files were fixed. (4) Most bug reports led to changes in more than one type of file. The majority of changes to auto-generated source code files were made in conjunction to changes in either file with state chart models or XML files derived from dictionaries. (5) For newly developed files, AGC-M and handwritten code were of similar quality, while AGC-D files were the least fault prone.

Goseva-Popstojanova, Katerina↗

Software Development Standard Processes (SDSP)

A JPL-created set of standard processes is to be used throughout the lifecycle of software development. These SDSPs cover a range of activities, from management and engineering activities, to assurance and support activities. These processes must be applied to software tasks per a prescribed set of procedures. JPL s Software Quality Improvement Project is currently working at the behest of the JPL Software Process Owner to ensure that all applicable software tasks follow these procedures. The SDSPs are captured as a set of 22 standards in JPL s software process domain. They were developed in-house at JPL by a number of Subject Matter Experts (SMEs) residing primarily within the Engineering and Science Directorate, but also from the Business Operations Directorate and Safety and Mission Success Directorate. These practices include not only currently performed best practices, but also JPL-desired future practices in key thrust areas like software architecting and software reuse analysis. Additionally, these SDSPs conform to many standards and requirements to which JPL projects are beholden.

Lavin, Milton L.↗

Daily QA of linear accelerators using only EPID and OBI

Purpose: As treatment delivery becomes more complex, there is a pressing need for robust quality assurance (QA) tools to improve efficiency and comprehensiveness while simultaneously maintaining high accuracy and sensitivity. This work aims to present the hardware and software tools developed for comprehensive QA of linear accelerator (LINAC) using only electronic portal imaging devices (EPIDs) and kV flat panel detectors. Methods: A daily QA phantom, which includes two orthogonally positioned phantoms for QA of MV-beams and kV onboard imaging (OBI) is suspended from the gantry accessory holder to test both geometric and dosimetric components of a LINAC and an OBI. The MV component consists of a 0.5 cm water-equivalent plastic sheet incorporating 11 circular steel plugs for transmission measurements through multiple thicknesses and one resolution plug for MV-image quality testing. The kV-phantom consists of a Leeds phantom (TOR-18 FG phantom supplied by Varian) for testing low and high contrast resolutions. In the developed process, the existing LINAC tools were used to automate daily acquisition of MV and kV images and software tools were developed for simultaneous analysis of these images. A method was developed to derive and evaluate traditional QA parameters from these images [output, flatness, symmetry, uniformity, TPR{sub 20/10}, and positional accuracy of the jaws and multileaf collimators (MLCs)]. The EPID-based daily QA tools were validated by performing measurements on a detuned 6 MV beam to test its effectiveness in detecting errors in output, symmetry, energy, and MLC positions. The developed QA process was clinically commissioned, implemented, and evaluated on a Varian TrueBeam LINAC (Varian Medical System, Palo Alto, CA) over a period of three months. Results: Machine output constancy measured with an EPID (as compared against a calibrated ion-chamber) is shown to be within ±0.5%. Beam symmetry and flatness deviations measured using an EPID and a 2D ion-chamber array agree within ±0.5% and ±1.2% for crossline and inline profiles, respectively. MLC position errors of 0.5 mm can be detected using a picket fence test. The field size and phantom positioning accuracy can be determined within 0.5 mm. The entire daily QA process takes ∼15 min to perform tests for 5 photon beams, MLC tests, and imaging checks. Conclusions: The exclusive use of EPID-based QA tools, including a QA phantom and simultaneous analysis software tools, has been demonstrated as a viable, efficient, and comprehensive process for daily evaluation of LINAC performance.

60 APPLIED LIFE SCIENCES↗

Optical imaging analysis of microscopic radiation dose gradients in Gafchromic EBT film using a digital microscope

By providing superior localization and immobilization, stereotactic radiosurgery (SRS) is capable of delivering millimeter spheres of dose to intracranial targets with submillimeter precision. Several authors have proposed new SRS solutions to dramatically reduce beam penumbra to hundreds of microns. These solutions require new quality assurance methods capable of penumbra measurement at the micron scale. This article examines the capability of a digital microscope, with translation stage and associated software, to resolve dose gradients in Gafchromic EBT film at this level. To produce very steep penumbra, films were irradiated in phantom beneath pinhole collimators using lower energy x rays (100 kVp, 300 kVp, and Iridium-192) and minimal geometric penumbra contribution. For film analysis, a method was developed which improved the signal to noise ratio by finding the center of the irradiation spot, generating several radial dose profiles and averaging these to obtain the final off-axis dose profile. Optical density was converted to dose using a calibration curve. The experimentally determined off-axis dose profiles were compared with MCNP Monte Carlo simulations which replicated the irradiation geometry and served to validate our measured data. The measured 80%-20% penumbral widths were 46 {mu}m{+-}26 {mu}m (100 kVp, 2 mm field size), 69 {mu}m{+-}27 {mu}m (300 kVp, 2 mm field size), and 241 {mu}m{+-}31 {mu}m (Ir-192, 1 mm field size). These penumbral widths agreed with Monte Carlo simulations within experimental uncertainty. Our findings suggest that reading Gafchromic EBT films using a digital microscope with translation stage is suitable for the quality assurance of very sharp penumbra able to resolve gradients to within at least 30 {mu}m.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-D-BRA-06: IMRT QA with ArcCHECK: The MD Anderson Experience

Purpose: The objective of this project was to report our initial IMRT QA results and experience with the SunNuclear ArcCHECK. Methods: Three thousand one-hundred and sixteen cases were treated with IMRT or VMAT at our institution between October 2013 and September 2014. All IMRT/VMAT treatment plans underwent Quality Assurance (QA) using ArcCHECK prior to therapy. For clinical evaluation, a Gamma analysis is performed following QA delivery using the SNC Patient software (Sun Nuclear Corp) at the 3%/3mm level. QA Gamma pass rates were analyzed based on categories of treatment site, technique, and type of MLCs. Our current clinical threshold for passing a QA (Tclin) is set at a Gamma pass rate greater than 90%. We recorded the percent of failures for each category, as well as the Gamma pass rate threshold that would Result in 95% of QAs to pass (T95). Results: Using Tclin a failure rate of 5.9% over all QAs was observed. The highest failure rate was observed for gynecological (22%) and the lowest for CNS (0.9%) treatments. T95 was 91% over all QAs and ranged from 73% (gynecological) to 96.5% (CNS) for individual treatments sites. T95 was lower for IMRT and non-HD (high definition) MLCs at 88.5% and 94.5%, respectively, compared to 92.4% and 97.1% for VMAT and HD MLC treatments, respectively. There was a statistically significant difference between the passing rates for IMRT vs. VMAT and for HD MLCs vs. non-HD MLCs (p-values << 0.01). Gynecological, IMRT, and HD MLC treatments typically include more plans with larger field sizes. Conclusion: On average, Tclin with ArcCHECK was consistent with T95, as well as the 90% action level reported in TG-119. However, significant variations between the examined categories suggest a link between field size and QA passing rates and may warrant field size-specific passing rate thresholds.

60 APPLIED LIFE SCIENCES↗

SU-E-P-05: Is Routine Treatment Planning System Quality Assurance Necessary?

Purpose: To evaluate the variation of dose calculations using a treatment planning system (TPS) over a two year period and assessment of the need for TPS QA on regular intervals. Methods: Two phantoms containing solid water and lung- and bone-equivalent heterogeneities were constructed in two different institutions for the same brand treatment planning system. Multiple plans, consisting of photons and electron beams, including IMRT and VMAT ones, were created and calculated on the phantoms. The accuracy of dose computation in the phantoms was evaluated at the onset by dose measurements within the phantoms. The dose values at up to 24 points of interest (POI) within the solid water, lung, and bone slabs, as well as mean doses to several regions of interest (ROI), were re-calculated over a two-year period which included two software upgrades. The variations in POI and ROI dose values were analyzed and evaluated. Results: The computed doses vary slightly month-over-month. There are noticeable variations at the times of software upgrade, if the upgrade involves remodeling and/or re-commissioning of the beams. The variations are larger in certain points within the phantom, usually in the buildup region or near interfaces, and are almost non-existent for electron beams. Conclusion: Routine TPS QA is recommended by AAPM and other professional societies, and is often required by accreditation organizations. The frequency and type of QA, though, is subject to debate. The results presented here demonstrate that the frequency of these tests could be at longer intervals than monthly. However, it is essential to perform TPS QA at the time of commissioning and after each software upgrade.

60 APPLIED LIFE SCIENCES↗

SU-E-T-126: Application of PIPSpro and EPID for Quality Assurance of Medical Accelerators

Purpose: The purpose is to study applying PIPSpro and EPID for routine quality assurance of medical accelerators. Methods: (1) The coincidence of Light field and radiation field: Placed the FC-2 phantom on the treatment couch at the 100cm SSD. Using jaw set 10×10 cm{sup 2} or 15×15 cm{sup 2} field. Verified that the light field aligns with the engraved squares on the phantom. Placed the Crosshair Marker phantom on the top of the FC-2 phantom with the cross-hair and spherical marker aligned to the center of the light field. Acquired images with EPID and the images should be exported preferably in DICOM format. Analyzed Follow the recommended procedures in the radiation light field module of PIPSpro software.(2)MLC QA:Set up the MLC phantom on the treatment couch at isocenter. Positioned the EPID imager at the highest possible position without colliding with either the couch or the phantom. Created and delivered four different patterns for testing the MLC leaf position, leaf width, multi-port and leaf transmission. (3)Radiation isocenter test: Included the isocenter of collimator rotation, gantry rotation and couch rotation. Set the jaws of the collimator to create a thin field as 0.4cm x 20cm.Irradiated film or EPID using an equidistant 15° spacing angles with rotating collimator, gantry and couch respectively. Results: We analyzed imagers from EPID and film with PIPSPro software. As a Result, we acquired the specifications of medical accelerators quickly. In the meantime, the results were saved to database for trending and future analysis. Conclusion: Quality assurance of medical accelerator is very important. We used PIPSpro and EPID for routine detection, not only improved our efficiency, but also saved the cost. It is an good method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗