Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SnS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Shielding development for the VENUS imaging instrument

VENUS is an imaging instrument that will use a broad range of neutron wavelengths, from epithermal to cold, will include enhanced contrast mechanisms, and will offer novel energy-selective imaging techniques that directly connect the structures, properties, and function of complex engineering materials and systems to reveal practical and fundamental answers about their real-world performance. The instrument is to be built at SNS beam line 10 and will face the decoupled poisoned hydrogen moderator. The driving cost for the instrument is the beam line and instrument cave shielding. Initial scoping analyses were performed to estimate thickness and composition of shielding materials for the instrument cave and beam line. In light of the upcoming Proton Power Upgrade (PPU) project, these transport analyses were performed for proton beam on target at 1.3 GeV and 2 MW.

Popova, Irina I.↗

A Smart Vision-Aided RICH (Robotic Interface Control and Handling) System for VULCAN

High-flux neutron beams and high-efficiency detectors enable rapid neutron diffraction measurements at the Engineering Materials Diffractometer (VULCAN) at the Spallation Neutron Source (SNS), Oak Ridge National Laboratory (ORNL). To optimize beam time utilization, efficient sample exchange, alignment, and automated measurements are essential. Recent advances in artificial intelligence (AI) have expanded the capabilities of robotic systems. Here, we report the development of a Robotic Interactive Control and Handling (RICH) system for sample handling at VULCAN, designed to support high-throughput experiments and reduce overhead time. The RICH system employs a six-axis desktop robot integrated with AI-based computer vision models capable of recognizing and localizing samples in real time from instrument and depth-resolving cameras. Vision algorithms combine these detections to align samples with designated measurement positions or place them within complex sample environments such as furnaces. This integration of machine learning-assisted vision with robotic handling demonstrates the feasibility of autonomous sample detection and preparation, offering a pathway toward fully unmanned neutron scattering experiments.

automation↗

Single Crystal Growth of Synthetic Sulfide- and Phosphide-Based Minerals for Physical Measurements

In this work, we review recent advances in the use of high-temperature solution growth that allow for the growth of single crystalline samples of synthetic minerals. We outline how low-melting binary or ternary solutions are attractive solvents for solution growth and provide examples of the growth of bismuthinite (Bi 2 S 3 ), galena (PbS) and parkerite (Ni 3 Bi 2 S 2 ). We then focus on the Rh-S, Pd-S and Ni-P phase spaces to discuss how the low-melting regions near transition metal-main group eutectic compositions make excellent solvents for crystal growth of several binary and ternary minerals containing both high melting and volatile elements as well as for the discovery of new materials. We end by discussing the growth of synthetic canfieldite (Ag 8 SnS 6 ) and argyrodite (Ag 8 GeS 6 ) from Ag 2 S–Sn-S-based solutions.

58 GEOSCIENCES↗

Improvements in the Sample Space for the Backscattering Silicon Spectrometer (BASIS)

The increase in neutron flux at the Oak Ridge National Laboratory (ORNL) Spallation Neutron Source (SNS), currently operating at 2.0 MW proton beam power, has created new opportunities for higher-throughput neutron scattering experiments while also increasing the importance of minimizing background scattering and optimizing sample-environment operations. To address these challenges on the Backscattering Silicon Spectrometer (BA-SIS), several upgrades were developed and evaluated, including boron carbide (B₄C) masking for flat-plate sample containers, multi-cell sample holders used with a vertically translating sample stick, and an automated helium pump and purge (HPP) system for closed-cycle refrigerators. Neutron diffraction measurements demonstrate that B₄C masks reduce background scattering by 49–67%, outperforming both borated aluminum and boron nitride masks while introducing no additional Bragg reflections within the instrument’s accessible Q-range. Commissioning tests of a double-cell flat-plate sample contain-er showed no measurable crosstalk between adjacent sample compartments and con-firmed stable thermal performance, enabling multiple samples to be measured without re-peated temperature cycling. In addition, the automated HPP system provided reproducible sample-space gas handling with approximately ±1 mbar precision while reducing the need for operator intervention and supporting remote operation. Together, these developments improve signal-to-noise performance, increase experimental throughput, and enhance operational efficiency at BASIS, supporting the instrument’s continued operation under higher neutron flux conditions.

Jalarvo, Niina [ORNL] (ORCID:0000000306446866)↗

Effect of Collimation on Diffraction Signal-to-Background Ratios at a Neutron Diffractometer

High diffraction signal-to-background ratios (SBRs), the ratios of diffraction peak integrated intensity over its background intensity, are desired for a neutron diffractometer to acquire good statistics for diffraction pattern measurements and subsequent data analysis. For a given detector, while the diffraction peak signals primarily depend on the characteristics of neutron beam and sample coherent scattering, the background largely originates from the sample incoherent scattering and the scattering from the instrument space. In this work, we investigated the effect of collimation on neutron diffraction SBRs of Si powder measurements using one high-angle area detector bank coupled with six different collimation configurations in a large and complex instrument space at the engineering materials diffractometer VULCAN, SNS, ORNL. The results revealed that the diffraction SBRs can be significantly improved by a proper coarse collimator that leaves no gap between the detector and the collimator, and the improvement of SBRs by a fine radial collimator was remarkable with a proper coarse collimator in place but not distinguishable without one. It was also found that the diffraction SBRs were not effectively improved by adding neutron absorbing element boron to the fine radial collimator body, which indicates that either the absorption of secondary scattered neutrons by the added boron is insignificant or the collimator base material (resin and ABS) alone attenuates background scattering sufficiently. These findings could serve as a useful reference for diffractometer developers and/or operators to optimize their collimation to achieve higher diffraction SBRs.

Yu, Dunji↗

TESLA's High Gradient March: Thirty years anniversary of TESLA Technology Collaboration (TTC)

In 2020, the TTC (TESLA Technology Collaboration) celebrates 30 years of collaborative efforts on SRF technologies. The first international TESLA workshop on a TeV Energy Superconducting Linear Accelerator was held at Cornell University on July 23-26, 1990. The purpose of the meeting was to work on a parameter list for a superconducting high energy physics collider in the Teravolt energy region and to explore ideas on how to increase the gradients and lower the costs for the accelerator structures. It was clear from the beginning that the needed technological progress would require a large international collaboration. This meeting was indeed the origin of a long preparation effort toward a future ILC (International Linear Collider), which eventually led to the realization of the TTF (TESLA Test Facility, since 2005 operated as the DESY user facility FLASH) and the European XFEL also at DESY, and created the conditions supporting the proposals for several large SRF-based research facilities like SNS, LCLS-II, ESS, PIP-II and SHINE, as well as a growing number of smaller facilities around the world. Highlights of this 30-year international collaboration are presented and celebrated.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Beyond RMS: Understanding the Evolution of Beam Distributions in High Intensity Linacs

Understanding the evolution of beams with space charge is crucial to design and operation of high intensity linacs. While the community holds a broad understanding of the mechanisms leading to emittance growth and halo formation, there is outstanding discrepancy between measurements and beam evolution models that precludes prediction of halo losses. This may be due in part to insufficient information of the initial beam distribution. This talk will describe work at the SNS Beam Test Facility to directly measure the 6D beam distribution. Full-and-direct 6D measurement has revealed hidden but physically significant dependence between the longitudinal distribution and transverse coordinates. This nonlinear correlation is driven by space charge and reproduced by self-consistent simulation of the RFQ. Omission of this interplane correlation, common when bunches are reconstructed from lower-dimensional measurements, degrades downstream predictions. This talk will also describe the novel diagnostics supporting this work. This includes ongoing improvements to efficiency of the 6D phase space measurement as well as recent achievement of six orders of dynamic range in 2D phase space.

Ruisard, Kiersten↗

Radiation hardened beam instrumentations for multi-Mega-Watt beam facilities

The radiation hardened beam instrumentations workshop was held on February 3rd and 4th, 2022 to identify the technological challenges on the beam instrumentation for multi-Mega-Watt (MW) beam facilities. We invited a speaker from a high energy neutrino beam facility (CERN, Fermilab and J-PARC), a collider detector group (CERN and Fermilab), a neutron spallation source facility (ESS, J-PARC and SNS), and a rare-isotope beam facility (FRIB). Although, the operational beam parameter for each institution is unique due to their different physics goals, we realize that there is a common issue on the beam instrumentation. Therefore, it will be tackled by a collaborative R&D effort among facilities. We summarize an output from the workshop in the paper, and propose a possible R&D for the future radiation hardened beam instrumentations with a global effort.

43 PARTICLE ACCELERATORS↗

Superconducting qubit devices based on metal silicides

A qubit device for use in a quantum computing environment includes a semiconductor substrate, an insulating layer disposed on at least a portion of an upper surface of the substrate, and a transition metal silicide (TMSi) heterojunction disposed on at least a portion of an upper surface of the insulating layer. The TMSi heterojunction includes a link layer and at least first and second TMSi regions coupled with the link layer. The link layer may include a normal conductor, thereby forming a superconductor-normal conductor-superconductor (SNS) junction, or a geometric constriction, thereby forming a superconductor-geometric constriction-superconductor (ScS) junction. The link layer may form at least a portion of a channel including intrinsic or doped silicon.

Black, Charles T.↗

Progress on the Proton Power Upgrade at the Spallation Neutron Source

The Proton Power Upgrade Project at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory will double the proton power capability from 1.4 to 2.8 MW. This will be accomplished through an energy increase from 1.0 to 1.3 GeV and a beam current increase from 26 to 38 mA. The energy increase will be accomplished through the addition of 7 cryomodules to the linear accelerator (Linac). The beam current increase will be supported by upgrading several radio-frequency systems in the normal-conducting section of the Linac. Upgrades to the accumulator ring injection and extraction regions will accommodate the increase in beam energy. A new 2-MW-capable target and supporting systems will be developed and installed. Conventional facility upgrades include build-out of the existing klystron gallery and construction of a tunnel stub to facilitate future beam transport to the second target station. The project received approval to proceed with construction in October 2020. Procurements are in progress, and some installation activities have already occurred. Most of the installation will take place during three outages in 2022-2023. The project early finish is planned for 2025.

Barbier, Charlotte↗

Design and fabrication of the waveguide Iris couplers for the Spallation Neutron Source drift tube linac

The Spallation Neutron Source (SNS) employs six cavities in the Drift Tube Linac (DTL) section to accelerate the H- ion beam to 87MeV. Each cavity is energized by a 2.5MW peak power klystron at 402.5MHz using rapid tapered waveguide iris couplers. All six original iris couplers have been in operation without replacement for over two decades. The increased RF power demands of the Proton Power Upgrade (PPU) project and operational problems, including arcing, temperature excursions, and vacuum bursts, have prompted the development of new iris coupler spares. The original iris couplers were made of GlidCop material, which is known to be mechanically strong and thermally stable, but is porous, expensive, and difficult to use in fabrication. To overcome these problems, the new spare couplers use Oxygen-Free Copper (OFC) and stainless steel (SS). This paper will discuss the mechanical, thermal and RF design, as well as challenges in the final coupler fabrication.

Lee, Sung-Woo↗

HIGH-LOW FIDELITY THERMAL HYDRAULIC COUPLING USING AI/MACHINE LEARNING ALGORITHMS

The primary goal of the US Department of Energy (DOE) office of Nuclear Energy Integrated Energy Systems (IES) program is to develop the tools and framework for coupling multi-scale and multi-physical thermal and electrical energy usage and storage systems. High- and low-fidelity (high–low) coupling is a key feature of multi-scale, multi-component systems and has been an important focus of research in the nuclear energy community for the past two decades. An essential feature of demonstrating the capability to couple high-fidelity and low-fidelity systems for real-time applications are surrogate/reduced order models (ROM). For the purposes of this study, surrogate models are essentially Blackbox models, typically developed using supervised Machine learning (ML) algorithms. The surrogate models can be used to mimic the response of high-fidelity models to represent large historical datasets and coupled with more general low-fidelity system models distributed as Functional Mock-up Interface (FMI) or Functional Mock-up Units (FMU) modules. The example is demonstrated with Spallation Neutron Source (SNS) First Target Station flow loop data. The flow loop is a liquid mercury loop with a pump, piping, heat exchange, and internal heat generation in the target window. This work elucidates some of the potential benefits and future needs of developing tools for high–low system coupling of energy systems.

Williams, Wesley↗

Comparison of Measured and Calculated Dose Rates for Ring Injection Dump Exchange at Spallation Neutron Source

According to the accelerator operation plan, the beam-stop and the proton beam window (PBW) assemblies of the existing Ring Injection Dump RID are replaced with fresh assemblies, when they have reached their end-of-life. End of-life is determinate by the stainless-steel beam-stop window having accumulated 10 dpa radiation damage. The exchange process took place during facility maintenance period that started in March 2023. Each of the spent assembles were put into specially designed storage containers temporarily residing near the RID building.The spent beam-stop is predicted to be the part of highest activation that has been removed in Spallation Neutron Source (SNS). The exchange processes require good work planning to minimize radiation exposure to personal. For each exchange step the residual dose rate distribution is calculated and the peak values are identified. This paper gives some examples of calculated vs measured doses during beam-stop assembly exchange.

Popova, Irina I.↗

Overview on Analyses of Dose Rates During RID Parts Removal/Exchange

One of the most irradiated Spallation Neutron Source (SNS) accelerator components is ring injection dump (RID), which is located downstream of the accumulator ring injection section. The unstripped and only partially stripped H- beam is discarded in the injection into the accumulator ring and is redirected to the RID, which is about 5% of the full beam current. According to the accelerator operation plan, the beam stop and the window assemblies of the existing RID will be removed and replaced, when they have reached their end-of-life. This procedure, which includes multiple steps, is scheduled to take place during facility maintenance period in January 2023.In order to support job planning and meet ALARA requirements during removal and exchange of the components, dose rates for each stage of exchange operation are calculated.

Popova, Irina I.↗

The Impact of High-Dimensional Phase Space Correlations on the Beam Dynamics in a Linear Accelerator

Hadron beams develop intensity-dependent transverse-longitudinal correlations within radio-frequency quadrupole (RFQ) accelerating structures. These correlations are only visible in six-dimensional phase space and are destroyed by reconstructions from low-dimensional projections. In this work, we estimate the effect of artificial decorrelation on the beam dynamics in the Spallation Neutron Source (SNS) linac and Beam Test Facility (BTF). We show that the evolution of a realistic initial distribution and its decorrelated twin converge during the early acceleration stages; thus, low-dimensional projections are probably sufficient for detailed predictions in high-power linacs.

Hoover, Austin↗

Measurements of the Five-Dimensional Phase Space Distribution of an Intense Ion Beam

No simulation of intense beam transport has accurately reproduced measurements at the level of beam halo. One potential explanation of this discrepancy is a lack of knowledge of the initial distribution of particles in six-dimensional (6D) phase space. A direct 6D measurement of an ion beam was recently performed at the Spallation Neutron Source (SNS) Beam Test Facility (BTF), revealing nonlinear transverse-longitudinal correlations in the beam core that affect downstream evolution. Unfortunately, direct 6D measurements are limited in resolution and dynamic range; here, we discuss the use of three slits and one screen to measure a 5D projection of the 6D phase space distribution, overcoming these limitations at the cost of one dimension. We examine the measured 5D distribution before and after transport through the BTF and compare to particle-in-cell simulations. We also discuss the possibility of reconstructing the 6D distribution from 5D and 4D projections.

Hoover, Austin↗

Calibration of the analog beam-signal hardware for the credited engineered beam power limit system at the Proton Power Upgrade Project at the Spallation Neutron Source

A programmable signal processor-based credited safety control that calculates pulsed beam power based on beam kinetic energy and charge was designed as part of the Proton Power Upgrade (PPU) project at the Spallation Neutron Source (SNS). The system must reliably shut off the beam if the average power exceeds 2.145 MW averaging over 60 seconds. System calibration requires pedigree in measurements, calibration setup, and calculations. This paper discusses the calibration of the analog beam signal components up to and including the Analog Digital Convertors (ADCs) for implementation into the Safety Programmable Logic Controllers (PLCs) and Field Programmable Gate Arrays (FPGAs).

Bobrek, Miljko↗

Emergent topological polarization textures in relaxor ferroelectrics

Relaxor ferroelectrics underpin high-performance actuators and sensors, yet the nature of polar heterogeneities driving their broadband dielectric response remains debated. Using a unified, multimodal structural refinement framework— simultaneously fitting complementary X-ray and neutron total scattering, X-ray absorption spectra, and diffuse scattering—we reconstruct 3D mesoscale polarization maps in the classic relaxor system PbMg 1/3 Nb 2/3 O 3 –PbTiO 3 . We uncover self-organized swirling polarization textures with half-skyrmion (meron) vortices, challenging models of independent polar nanoregions. These textures, characterized by smooth changes in the polarization direction, originate from overlapping volumes in which the projections of locally correlated polarization vectors onto each volume’s long axis share the same sign. Vortex cores correlate strongly with local charge and strain gradients imposed by compositional heterogeneities. In this work, our results suggest that chemical disorder, acting via depolarizing and strain fields, stabilizes topological vortex textures of the polarization field, offering a route for engineering new dielectric and ferroelectric functionalities.

Eremenko, Maksim [National Institute of Standards ↗