Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Selection pressure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Impact of bypass ratio on thrust-to-weight for V/STOL

Issues involved in the selection of a V/STOL propulsion system are discussed. The effect of bypass ratio on thrust-to-weight, fuel flow, and hover efficiency is investigated for the cases of four representative tilt propulsion system aircraft. The effect of fan pressure ratio on engine selection is shown to be very mission dependent. It is noted that the FAA requires reserves based on fixed wing or helicopter operations, neither of which is found to be entirely appropriate for STOVL aircraft.

Wilson, Samuel↗

Tuning Strong Metal–Support Interaction Kinetics on Pt-Loaded TiO 2 (110) by Choosing the Pressure: A Combined Ultrahigh Vacuum/Near-Ambient Pressure XPS Study

Pt catalyst particles on reducible oxide supports often change their activity significantly at elevated temperatures due to the strong metal–support interaction (SMSI), which induces the formation of an encapsulation layer around the noble metal particles. However, the impact of oxidizing and reducing treatments at elevated pressures on this encapsulation layer remains controversial, partly due to the “pressure gap” between surface science studies and applied catalysis. In the present work, we employ synchrotron-based near-ambient pressure X-ray photoelectron spectroscopy (NAP-XPS) to study the effect of O 2 and H 2 on the SMSI-state of well-defined Pt/TiO 2 (110) catalysts at pressures of up to 0.1 Torr. Further, by tuning the O 2 pressure, we can either selectively oxidize the TiO 2 support or both the support and the Pt particles. Catalyzed by metallic Pt, the encapsulating oxide overlayer grows rapidly in 1 × 10 –5 Torr O 2 , but orders of magnitude less effectively at higher O 2 pressures, where Pt is in an oxidic state. While the oxidation/reduction of Pt particles is reversible, they remain embedded in the support once encapsulation has occurred.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Two-Photon Laser-Induced Fluorescence O and N Atoms for the Study of Heterogeneous Catalysis in a Diffusion Reactor

Advanced laser-based diagnostics have been developed to examine catalytic effects and atom/surface interactions on thermal protection materials. This study establishes the feasibility of using laser-induced fluorescence for detection of O and N atom loss in a diffusion tube to measure surface catalytic activity. The experimental apparatus is versatile in that it allows fluorescence detection to be used for measuring species selective recombination coefficients as well as diffusion tube and microwave discharge diagnostics. Many of the potential sources of error in measuring atom recombination coefficients by this method have been identified and taken into account. These include scattered light, detector saturation, sample surface cleanliness, reactor design, gas pressure and composition, and selectivity of the laser probe. Recombination coefficients and their associated errors are reported for N and O atoms on a quartz surface at room temperature.

Pallix, Joan B.↗

Investigation of a para-ortho hydrogen reactor for application to spacecraft sensor cooling

The utilization of solid hydrogen in space for sensor and instrument cooling is a very efficient technique for long term cooling or for cooling at high heat rates. The solid hydrogen can provide temperatures as low as 7 to 8 K to instruments. Vapor cooling is utilized to reduce parasitic heat inputs to the 7 to 8 K stage and is effective in providing intermediate cooling for instrument components operating at higher temperatures. The use of solid hydrogen in place of helium may lead to weight reductions as large as a factor of ten and an attendent reduction in system volume. The results of an investigation of a catalytic reactor for use with a solid hydrogen cooling system is presented. Trade studies were performed on several configurations of reactor to meet the requirements of high reactor efficiency with low pressure drop. Results for the selected reactor design are presented for both liquid hydrogen systems operating at near atmospheric pressure and the solid hydrogen cooler operating as low as 1 torr.

Nast, T. C.↗

DGEN Aeropropulsion Research Turbofan Core/Combustor-Noise Measurements-Experiment and Modal Structure at Core-Nozzle Exit

Data from a recent core/combustor-noise source-diagnostic test utilizing a small turbo-fan engine are analyzed. The campaign continued the exploration begun in a baseline test, but with more extensive acoustic instrumentation. Both tests were aimed at developing a better understanding of propulsion-noise sources and their impact on the farfield noise signature, in order to enable improved turbofan noise-prediction methods and noise-mitigation techniques. Simultaneous high-data-rate acoustic measurements (93 channels in total) were obtained using a circumferential sensor array at the core-nozzle exit in conjunction with sideline and farfield microphone arrays for several relevant engine operational points. Measurements were repeated for different circumferential and sideline array configurations, as well as for redundancy. The unsteady pressure field at the core-nozzle exit is documented in detail. Previous work suggested that the±1azimuthal duct mode could be cut-on at this location, which would have implications for combustor-noise modeling and prediction. The modal decomposition of the combustor noise at the core-nozzle exit verifies this observation. Select farfield sound-pressure-level spectra are also presented.

Aeroacoustics↗

Voltage-To-Frequency Converter For Pressure Calibration

Measurements of pressures on walls of wind tunnels and on surfaces of models in wind tunnels made with help of electronically scanned pressure-measurement (ESP) system. Voltage-to-frequency converter circuit, designed to convert 0- to 5-Vdc analog output voltage from high-line-pressure, low-differential-pressure standard to required frequency range. Enables selection of wider variety of high-accuracy pressure standards to enhance accuracy of measurement of ESP instrumentation while requiring little modification of manufacturer's system and no modification of operating software of system. Useful primarily in wind-tunnel instrumentation and readily adaptable to commercial instruments currently in use.

Sealey, Bradley S.↗

SAM Code Validation on Frictional Pressure Drop through Pebble Beds

The System Analysis Module (SAM) is currently under development at Argonne National Laboratory as a modern system-level modeling and simulation tool for safety analyses of advanced non-light water reactors. This report presents a recent effort to validate the capability of SAM to predict the frictional pressure drop through pebble beds. Selected experimental data were used for code validation, including data from test facilities at Texas A&M University, Missouri University of Science and Technology, and North-West University of South Africa. SAM implements three empirical correlations to predict frictional pressure drop: the classical Ergun correlation; the KTA correlation, which is widely used in high-temperature gas-cooled reactor applications; and the Eisfeld and Schnitzlein correlation, which explicitly considers wall effect. Code validation was performed using all three correlations. For all selected experimental data, the KTA correlation shows the best performance and agrees very well with experimental measurement; the Eisfeld and Schnitzlein correlation, explicitly considering wall effects, shows acceptable accuracy, while there is no evidence that it is better than the KTA correlation; the Ergun correlation, however, over-predicts frictional pressure drop for most selected data points.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Special report: Occlusive cuff controller

A mechanical occlusive cuff controller suitable for blood flow experiments in space shuttle flights is described. The device requires 115 volt ac power and a pressurized gas source. Two occluding cuff pressures (30 and 50 mmHg) are selectable by a switch on the front panel. A screw driver adjustment allows accurate cuff pressurization levels for under or oversized limbs. Two pressurization cycles (20 second and 2 minutes) can be selected by a front panel switch. Adjustment of the timing cycles is also available through the front panel. A pushbutton hand switch allows remote start of the cuff inflation cycle. A stop/reset switch permits early termination of the cycle and disabling of the controller to prevent inadvertent reactivation. Pressure in the cuff is monitored by a differential aneroid barometer. In addition, an electrocardiogram trigger circuit permits the initiation of the pressurization cycle by an externally supplied ECG cycle.

Baker, J. T.↗

Macrovoid resolved simulations of transport through HPRO relevant membrane geometries

Modeling the transport properties such as diffusivity and permeability of high pressure reverse osmosis (HPRO) membranes is critical for the selection and manufacture of membranes suitable for operation under high pressure. These properties can be significantly affected by the changes in heterogeneous pore structures due to compaction. Here, the modeling platform presented in this work resolves the two scale porosity in HPRO relevant membranes. A synthetic membrane geometry is constructed based on available experimental visualizations of pore structures. The simulations directly capture the flow channeling that results from a combination of material properties and geometric features of the macrovoids. A parametric study is presented to account for the transition of flow characteristics from a material governed regime to a macrovoid governed regime. Permeability of the membrane is evaluated using the simulation data and compared with an existing model that scales with the square of tortuosity over a range of material properties. The model is found to perform well under a narrow range of tortuosity while deviating from the calculated permeabilities at extreme conditions. The effective permeability of the membrane is found to vary by at least two orders of magnitude between the two flow regimes. It is also observed that tortuosity is a bounded property with its upper limit determined by the macrovoid geometry. Consequently, the tortuosity based correlations fail near a flow regime that is mainly governed by the macrovoids. The modeled permeability can be more than an order of magnitude smaller than the simulation result. A new model based on flux-weighted porosity of a membrane is introduced and its correlation with tortuosity is studied. The model agrees with the simulated data as, in addition to tortuosity, it also accounts for the flux partition within and outside the flow channels. Such correlations enable extending the existing understanding of flow characteristics to enhance predictability of porous media models.

42 ENGINEERING↗

Apollo experience report: The cryogenic storage system

A review of the design, development, and flight history of the Apollo cryogenic storage system and of selected components within the system is presented. Discussions are presented on the development history of the pressure vessels, heaters, insulation, and selected components. Flight experience and operational difficulties are reported in detail to provide definition of the problems and applicable corrective actions.

Chandler, W. A.↗

Aerodynamic characteristics of an NASA supercritical-wing research airplane model with and without fuselage area-rule additions at Mach 0.25 to 1.00

Transonic pressure tunnel tests at Mach numbers from 0.25 to 1.00 were performed to determine the effects of area-rule additions to the sides of the fuselage on the aerodynamic characteristics of a 0.087 scale model of an NASA supercritical-wing research airplane. Presented are the longitudinal aerodynamic force and moment characteristics for horizontal-tail deflection angles of -2.5 deg and -5 deg with the side fuselage area-rule additions on and off the model. The effects of the side fuselage area-rule additions on selected wing and fuselage pressure distributions at near-cruise conditions are also presented.

Bartlett, D. W.↗

GC/MS Method Development for Separating Lunar Volatile Ice Simulant Headspace Gases

Various investigators propose the lunar surface contains widely distributed volatiles, especially water- like species, i.e. OH and H2O. Surface volatiles are theorized to exist as a hydrated regolith layer, concentrated in extremely cold polar permanently shadowed regions (PSR), and/or solar wind implantation reservoirs in lunar glasses. The proposed sources of lunar surface volatiles range from cometary impacts, solar wind, or a supply present during moon formation. Future Artemis missions aim to collect and return the samples containing volatiles collected near lunar polar craters or PSRs. We, as advanced curation scientists, are responsible for developing techniques and methodologies for preserving returned sample integrity as much as possible. Pristine volatile-bearing samples are invaluable to the scientific community seeking to unravel the history of the solar system. Realistically, a sample will experience alteration during collection, transportation back to earth, and storage. The Planetary Exploration and Astromaterials Research Lab (PEARL) seeks to understand temperature and pressure effects on high-fidelity volatile-containing regolith simulants, the foundation for the future of cold curation. This abstract outlines the separation, identification, and quantification of headspace gases over volatile ice feed stock material using gas chromatography/mass spectrometry (GC/MS). Preliminary objectives concentrated on sample handling, reproducibility, and understanding the elution characteristics for each analyte. Initial GC/MS method development experiments utilized diluted static headspace sample preparation. Diluted samples were used because sampling headspace gases directly from a vial containing liquid analyte resulted in overloading of the column and detector. Overloading is evident based on chromatogram peak shapes and instrument contamination, or carry over, between experiments. A mixture of three alcohols were used for a majority of the sample handling and reproducibility studies. Reproducibility was tested via multiple users, calibration curves, and check standards. Stock solutions of condensed lunar volatile analytes included methanol, ammonia in methanol, hydrogen sulfide in water, and an equal volume mixture of methanol, ethanol, and isopropanol. Current samples use room air as the headspace sample matrix, however future experiments will incorporate an inert purge gas, such as argon or nitrogen. Three mL of each analyte solution were capped in separate 20 mL crimp top GC vials. Dilutions were carried out by removing an aliquot of headspace gases with a calibrated 1 mL gastight syringe and immediately transferring to a 20 mL capped crimp top vial. The GC/MS is a Thermo Fisher Trace 1310/ISQ 7000 with a TriPlus RSH autosampler and split/splitless injector module. The experiments outlined in this abstract use the following hardware: a 2.5 mL gastight headspace syringe tool, 1 mm ID x 78.5 mm length ultra-inert straight injection liner, and a TG-BondQ 30 m × 0.32 mm × 10 μm column. Various parameters, such as hardware selection and the temperature, pressure, and split ratio set points, continue to evolve as the overall experiment is refined. Diluted headspace chromatograms were collected for the individual stock solutions. Retention times, peak shapes, and mass spectra were evaluated and added to the data processing method for each molecule of interest. Figure 1 shows the total ion chromatograms for the three major lunar volatile simulant stock solutions: methanol, 7 N ammonia in methanol, and 0.4% hydrogen sulfide in water. Tailing peak shapes for ammonia (2.98 min rt) and water (4.06 min rt) indicate the molecules are not properly eluting from the selected column with the current separation method. Additionally, hydrogen sulfide and ammonia have overlapping peak windows, which could impact quantification. Ongoing experiments aim to address the peak shape and overlapping via the separation method and hardware selection. Sample preparation reproducibility experiments used stock solution containing equal volumes of a non- interactive mixture of methanol, ethanol, and isopropanol. Mass spectrum ion traces were used to identify and quantify all three alcohols. Peaks were automatically detected, identified, and integrated through the mass spectra detection and processing parameters. Calibration response curves and check standards were used to evaluate the validity of the sample preparation procedure. Figure 2 shows the methanol chromatogram peak area versus total headspace dilution volume transferred from the alcohol mixture vial. The calibration response curves and check standards validate sample preparation procedure. Continuing data analysis efforts are working towards correlating the peak area and instrument response factor to the headspace analyte concentration and condensed phase composition. Static headspace gas chromatography theory relies on Dalton’s law, Raoult’s law, Henry’s Law, and the Kolb and Ettre equation to associate peak area to the analyte composition in a non-ideal solution. Equation 1 is a simplified expression derived from the aforementioned theories. Future experiments involve liquid injections of the individual stock solutions, liquid and headspace analysis of various stock solution combinations, and the addition of regolith simulants to the mixtures. Temperature is another variable expected to affect reaction rates and will be explored.

Cecilia L. Amick↗

The Langley 8-ft transonic pressure tunnel laminar-flow-control experiment

An account is given of the considerations involved in selecting the NASA-Langley transonic pressure tunnel's design and test parameters, as well as its liner and a swept wing for laminar flow control (LFC) experimentation. Attention is given to the types and locations of the instrumentation employed. Both slotted and perforated upper surfaces were tested with partial- and full-chord suction; representative results are presented for all.

Bobbitt, Percy J.↗

Gas Chromatograph Method Optimization Trade Study for RESOLVE: 20-meter Column v. 8-meter Column

RESOLVE is the payload on a Class D mission, Resource Prospector, which will prospect for water and other volatile resources at a lunar pole. The RESOLVE payload's primary scientific purpose includes determining the presence of water on the moon in the lunar regolith. In order to detect the water, a gas chromatograph (GC) will be used in conjunction with a mass spectrometer (MS). The goal of the experiment was to compare two GC column lengths and recommend which would be best for RESOLVE's purposes. Throughout the experiment, an Inficon Fusion GC and an Inficon Micro GC 3000 were used. The Fusion had a 20m long column with 0.25mm internal diameter (Id). The Micro GC 3000 had an 8m long column with a 0.32mm Id. By varying the column temperature and column pressure while holding all other parameters constant, the ideal conditions for testing with each column length in their individual instrument configurations were determined. The criteria used for determining the optimal method parameters included (in no particular order) (1) quickest run time, (2) peak sharpness, and (3) peak separation. After testing numerous combinations of temperature and pressure, the parameters for each column length that resulted in the most optimal data given my three criteria were selected. The ideal temperature and pressure for the 20m column were 95 C and 50psig. At this temperature and pressure, the peaks were separated and the retention times were shorter compared to other combinations. The Inficon Micro GC 3000 operated better at lower temperature mainly due to the shorter 8m column. The optimal column temperature and pressure were 70 C and 30psig. The Inficon Micro GC 3000 8m column had worse separation than the Inficon Fusion 20m column, but was able to separate water within a shorter run time. Therefore, the most significant tradeoff between the two column lengths was peak separation of the sample versus run time. After performing several tests, it was concluded that better detection via good peak separation with a longer run time is a better asset than moderate peak separation with a shorter run time. Even given that RESOLVE is highly interested in water and that mission timeline is of significant importance given the short seven-to-ten-day mission timeline, worse detection with an 8m column may lead to overlooking other substances existing on the moon that could advance planetary science. Thus, I recommend the 20m column. However, if mission timeline and water separation are deemed the highest priority, the 8m column should be selected due to its ability to separate water within a shorter run time than the 20m column.

Column↗

Chemical looping based ammonia production - A promising pathway for production of the noncarbon fuel

Ammonia, primarily made with Haber–Bosch process developed in 1909 and winning two Nobel prizes, is a promising noncarbon fuel for preventing global warming of 1.5 °C above pre-industrial levels. However, the undesired characteristics of the process, including high carbon footprint, necessitate alternative ammonia synthesis methods, and among them is chemical looping ammonia production (CLAP) that uses nitrogen carrier materials and operates at atmospheric pressure with high product selectivity and energy efficiency. To date, neither a systematic review nor a perspective in nitrogen carriers and CLAP has been reported in the critical area. So, this work not only assesses the previous results of CLAP but also provides perspectives towards the future of CLAP. It classifies, characterizes, and holistically analyzes the fundamentally different CLAP pathways and discusses the ways of further improving the CLAP performance with the assistance of plasma technology and artificial intelligence (AI).

30 DIRECT ENERGY CONVERSION↗

Operando XAS and DFT Uncover Structure-Performance Relationships in Re/TiO 2 for Selective CO 2 Hydrogenation to Methanol

The conversion of CO 2 into value-added chemicals, such as methanol, offers a promising pathway toward a renewable energy future. However, a precise kinetic control and a highly selective catalyst are necessary to overcome the thermodynamic preference for CO 2 hydrogenation to methane. Rhenium-based catalysts, particularly Re/TiO 2 , demonstrate high activity and selectivity for methanol under high-pressure conditions. For example, at 100 bar and 200 °C, a methanol selectivity of 97−99% was obtained. Catalysts with 1 wt % Re and 5 wt % Re/ TiO 2 were used to study the effect of cluster sizes. At 250 °C, the 1 wt % catalyst achieves 97% selectivity at 23% conversion, whereas 5 wt % Re/TiO 2 achieves 74% selectivity at 40% conversion, corresponding to a drop in space-time yield from 65 to 16 g CH 3 OH ·g Re −1 ·h −1 , respectively. X-ray absorption spectroscopy provided insights into the structure of the active sites, while density functional theory calculations revealed the effects of cluster size on the energy barriers for H 2 activation, CH 3 OH dissociation, and CH 3 OH desorption, all of which directly influence conversion and selectivity. These results underscore the importance of balancing cluster size for optimal catalyst performance and provide insights into the design of efficient and selective catalysts for renewable methanol production.

XAS↗

Alternative strategies of nutrient acquisition and energy conservation map to the biogeography of marine ammonia-oxidizing archaea

Ammonia-oxidizing archaea (AOA) are among the most abundant and ubiquitous microorganisms in the ocean, exerting primary control on nitrification and nitrogen oxides emission. Although united by a common physiology of chemoautotrophic growth on ammonia, a corresponding high genomic and habitat variability suggests tremendous adaptive capacity. Here, we compared 44 diverse AOA genomes, 37 from species cultivated from samples collected across diverse geographic locations and seven assembled from metagenomic sequences from the mesopelagic to hadopelagic zones of the deep ocean. Comparative analysis identified seven major marine AOA genotypic groups having gene content correlated with their distinctive biogeographies. Phosphorus and ammonia availabilities as well as hydrostatic pressure were identified as selective forces driving marine AOA genotypic and gene content variability in different oceanic regions. Notably, AOA methylphosphonate biosynthetic genes span diverse oceanic provinces, reinforcing their importance for methane production in the ocean. Together, our combined comparative physiological, genomic, and metagenomic analyses provide a comprehensive view of the biogeography of globally abundant AOA and their adaptive radiation into a vast range of marine and terrestrial habitats.