Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Insight into 3D micro-CT data: exploring segmentation algorithms through performance metrics

Three-dimensional (3D) micro-tomography (µ-CT) has proven to be an important imaging modality in industry and scientific domains. Understanding the properties of material structure and behavior has produced many scientific advances. An important component of the 3D µ-CT pipeline is image partitioning (or image segmentation), a step that is used to separate various phases or components in an image. Image partitioning schemes require specific rules for different scientific fields, but a common strategy consists of devising metrics to quantify performance and accuracy. The present article proposes a set of protocols to systematically analyze and compare the results of unsupervised classification methods used for segmentation of synchrotron-based data. Additionally, the proposed dataflow for Materials Segmentation and Metrics (MSM) provides 3D micro-tomography image segmentation algorithms, such as statistical region merging (SRM), k-means algorithm and parallel Markov random field (PMRF), while offering different metrics to evaluate segmentation quality, confidence and conformity with standards. Both experimental and synthetic data are assessed, illustrating quantitative results through the MSM dashboard, which can return sample information such as media porosity and permeability. The main contributions of this work are: (i) to deliver tools to improve material design and quality control; (ii) to provide datasets for benchmarking and reproducibility; (iii) to yield good practices in the absence of standards or ground-truth for ceramic composite analysis.

97 MATHEMATICS AND COMPUTING↗

Experimental Verification of Dispersed Fringe Sensing as a Segment Phasing Technique using the Keck Telescope

Dispersed Fringe Sensing (DFS) is an efficient and robust method for coarse phasing of segmented primary mirrors (from a quarter of a wavelength up to the depth of focus of a single segment, typically several tens of microns). Unlike phasing techniques currently used for ground-based segmented telescopes; this makes it particularly well-suited to the phasing of space-borne segmented telescopes, such as the James Webb Space Telescopes (JWST). In this work we validate DFS by using it to measure the pistons of the segments of one of the Keck telescopes; the results agree with those of the Shack-Hartmann based phasing scheme currently in use at Keck to within 2% over a range of initial piston errors of +/-16 microns.

dispersed fringe sensors↗

The Segmented Aperture Interferometric Nulling Testbed (SAINT) I: Overview and Air-side System Description

This work presents an overview of the This work presents an overview of the Segmented Aperture Interferometric Nulling Testbed (SAINT), a project that will pair an actively-controlled macro-scale segmented mirror with the Visible Nulling Coronagraph (VNC). SAINT will incorporate the VNCs demonstrated wavefront sensing and control system to refine and quantify the end-to-end system performance for high-contrast starlight suppression. This pathfinder system will be used as a tool to study and refine approaches to mitigating instabilities and complex diffraction expected from future large segmented aperture telescopes., a project that will pair an actively-controlled macro-scale segmented mirror with the Visible Nulling Coronagraph (VNC). SAINT will incorporate the VNCs demonstrated wavefront sensing and control system to refine and quantify the end-to-end system performance for high-contrast starlight suppression. This pathfinder system will be used as a tool to study and refine approaches to mitigating instabilities and complex diffraction expected from future large segmented aperture telescopes.

wavefront sensing↗

A Bayesian Approach for Image Segmentation with Shape Priors

Color and texture have been widely used in image segmentation; however, their performance is often hindered by scene ambiguities, overlapping objects, or missingparts. In this paper, we propose an interactive image segmentation approach with shape prior models within a Bayesian framework. Interactive features, through mouse strokes, reduce ambiguities, and the incorporation of shape priors enhances quality of the segmentation where color and/or texture are not solely adequate. The novelties of our approach are in (i) formulating the segmentation problem in a well-de?ned Bayesian framework with multiple shape priors, (ii) ef?ciently estimating parameters of the Bayesian model, and (iii) multi-object segmentation through user-speci?ed priors. We demonstrate the effectiveness of our method on a set of natural and synthetic images.

97 MATHEMATICS AND COMPUTING↗

Deterministic direct aperture optimization using multiphase piecewise constant segmentation

Purpose Direct aperture optimization (DAO) attempts to incorporate machine constraints in the inverse optimization to eliminate the post‐processing steps in fluence map optimization (FMO) that degrade plan quality. Current commercial DAO methods utilize a stochastic or greedy approach to search a small aperture solution space. In this study, we propose a novel deterministic direct aperture optimization that integrates the segmentation of fluence map in the optimization problem using the multiphase piecewise constant Mumford‐Shah formulation. Methods The Mumford‐Shah based direct aperture optimization problem was formulated to include an L2‐norm dose fidelity term to penalize differences between the projected dose and the prescribed dose, an anisotropic total variation term to promote piecewise continuity in the fluence maps, and the multiphase piecewise constant Mumford‐Shah function to partition the fluence into pairwise discrete segments. A proximal‐class, first‐order primal‐dual solver was implemented to solve the large scale optimization problem, and an alternating module strategy was implemented to update fluence and delivery segments. Three patients of varying complexity—one glioblastoma multiforme (GBM) patient, one lung (LNG) patient, and one bilateral head and neck (H&N) patient with 3 PTVs—were selected to test the new DAO method. For each patient, 20 non‐coplanar beams were first selected using column generation, followed by the Mumford‐Shah based DAO (DAO MS ). For comparison, a popular and successful approach to DAO known as simulated annealing—a stochastic approach—was replicated. The simulated annealing DAO (DAO SA ) plans were then created using the same beam angles and maximum number of segments per beam. PTV coverage, PTV homogeneity , and OAR sparing were assessed for each plan. In addition, high dose spillage, defined as the 50% isodose volume divided by the tumor volume, as well as conformity, defined as the van't Riet conformation number, were evaluated. Results DAO MS achieved essentially the same OAR doses compared with the DAO SA plans for the GBM case. The average difference of OAR D max and D mean between the two plans were within 0.05% of the plan prescription dose. The lung case showed slightly improved critical structure sparing using the DAO MS approach, where the average OAR D max and D mean were reduced by 3.67% and 1.08%, respectively, of the prescription dose. The DAO MS plan substantially improved OAR dose sparing for the H&N patient, where the average OAR D max and D mean were reduced by over 10% of the prescription dose. The DAO MS and DAO SA plans were comparable for the GBM and LNG PTV coverage, while the DAO MS plan substantially improved the H&N PTV coverage, increasing D99 by 6.98% of the prescription dose. For the GBM and LNG patients, the DAO MS and DAO SA plans had comparable high dose spillage but slightly worse conformity with the DAO MS approach. For the H&N plan, DAO MS was considerably superior in high dose spillage and conformity to the DAO SA . The deterministic approach is able to solve the DAO problem substantially faster than the simulated annealing approach, with a 9.5‐ to 40‐fold decrease in total solve time, depending on the patient case. Conclusions A novel deterministic direct aperture optimization formulation was developed and evaluated. It combines fluence map optimization and the multiphase piecewise constant Mumford‐Shah segmentation into a unified framework, and the resulting optimization problem can be solved efficiently. Compared to the widely and commercially used simulated annealing DAO approach, it showed comparable dosimetry behavior for simple plans, and substantially improved OAR sparing, PTV coverage, PTV homogeneity, high dose spillage, and conformity for the more complex head and neck plan.

Nguyen, Dan↗

Structures of segments of [alpha]-synuclein fused to maltose-binding protein suggest intermediate states during amyloid formation

Aggregates of the protein {alpha}-synuclein are the main component of Lewy bodies, the hallmark of Parkinson's disease. {alpha}-Synuclein aggregates are also found in many human neurodegenerative diseases known as synucleinopathies. In vivo, {alpha}-synuclein associates with membranes and adopts {alpha}-helical conformations. The details of how {alpha}-synuclein converts from the functional native state to amyloid aggregates remain unknown. In this study, we use maltose-binding protein (MBP) as a carrier to crystallize segments of {alpha}-synuclein. From crystal structures of fusions between MBP and four segments of {alpha}-synuclein, we have been able to trace a virtual model of the first 72 residues of {alpha}-synuclein. Instead of a mostly {alpha}-helical conformation observed in the lipid environment, our crystal structures show {alpha}-helices only at residues 1-13 and 20-34. The remaining segments are extended loops or coils. All of the predicted fiber-forming segments based on the 3D profile method are in extended conformations. We further show that the MBP fusion proteins with fiber-forming segments from {alpha}-synuclein can also form fiber-like nano-crystals or amyloid-like fibrils. Our structures suggest intermediate states during amyloid formation of {alpha}-synuclein.

59 BASIC BIOLOGICAL SCIENCES↗

Automated segmentation of porous thermal spray material CT scans with predictive uncertainty estimation

Abstract Thermal sprayed metal coatings are used in many industrial applications, and characterizing the structure and performance of these materials is vital to understanding their behavior in the field. X-ray computed tomography (CT) enables volumetric, nondestructive imaging of these materials, but precise segmentation of this grayscale image data into discrete material phases is necessary to calculate quantities of interest related to material structure. In this work, we present a methodology to automate the CT segmentation process as well as quantify uncertainty in segmentations via deep learning. Neural networks (NNs) have been shown to excel at segmentation tasks; however, memory constraints, class imbalance, and lack of sufficient training data often prohibit their deployment in high resolution volumetric domains. Our 3D convolutional NN implementation mitigates these challenges and accurately segments full resolution CT scans of thermal sprayed materials with maps of uncertainty that conservatively bound the predicted geometry. These bounds are propagated through calculations of material properties such as porosity that may provide an understanding of anticipated behavior in the field.

Martinez, Carianne↗

Machine-Learning-based Algorithms for Automated Image Segmentation Techniques of Transmission X-ray Microscopy (TXM)

Four state-of-the-art Deep Learning-based Convolutional Neural Networks (DCNN) were applied to automate the semantic segmentation of a 3D Transmission x-ray Microscopy (TXM) nanotomography image data. The standard U-Net architecture as baseline along with UNet++, PSPNet, and DeepLab v3+ networks were trained to segment the microstructural features of an AA7075 micropillar. A workflow was established to evaluate and compare the DCNN prediction dataset with the manually segmented features using the Intersection of Union (IoU) scores, time of training, confusion matrix, and visual assessment. Comparing all model segmentation accuracy metrics, it was found that using pre-trained models as a backbone along with appropriate training encoder-decoder architecture of the Unet++ can robustly handle large volumes of x-ray radiographic images in a reasonable amount of time. This opens a new window for handling accurate and efficient image segmentation of in situ time-dependent 4D x-ray microscopy experimental datasets.

36 MATERIALS SCIENCE↗

Semi-Automated Neuron Boundary Detection and Nonbranching Process Segmentation in Electron Microscopy Images

Neuroscientists are developing new imaging techniques and generating large volumes of data in an effort to understand the complex structure of the nervous system. The complexity and size of this data makes human interpretation a labor-intensive task. To aid in the analysis, new segmentation techniques for identifying neurons in these feature rich datasets are required. This paper presents a method for neuron boundary detection and nonbranching process segmentation in electron microscopy images and visualizing them in three dimensions. It combines both automated segmentation techniques with a graphical user interface for correction of mistakes in the automated process. The automated process first uses machine learning and image processing techniques to identify neuron membranes that deliniate the cells in each two-dimensional section. To segment nonbranching processes, the cell regions in each two-dimensional section are connected in 3D using correlation of regions between sections. The combination of this method with a graphical user interface specially designed for this purpose, enables users to quickly segment cellular processes in large volumes.

Connectomics↗

Sequence conservation of protein binding segments in intrinsically disordered regions

Highlights: • Sequence conservation in protein-binding segments in IDRs is analyzed. • Functionally constraint residues in protein-binding segments in IDRs are conserved. • Evolutionary distance should be considered in the comparison of IDRs. • Cryptic binding regions may influence sequence conservation of IDRs. Intrinsically disordered proteins are proteins with intrinsically disordered regions (IDRs) that do not adopt a globular structure in their free state. IDRs have unique regions having protein-binding segments of which play pivotal roles in many biological processes. The binding sites in IDRs are heterogeneous in terms of their sequence conservation: some are conserved and others are not. We have been running a database of intrinsically disordered proteins, IDEAL, and collecting such binding segments, which are called protean segments (ProSs), within it. In this study, we compared the sequence conservation of ProSs, structural domains (SDs), and IDRs other than ProSs (non-ProSs) and found that i) functionally constrained residues in ProSs tend to be conserved, ii) the distribution of conservation scores of ProSs is similar to those of SDs but not non-ProSs, and iii) ProSs found in human proteins are mostly conserved only in vertebrates. These results indicate that the conservation patterns in ProSs principally follow the general rules found in SDs. However, we need to consider evolutionary distance when comparing IDR sequences because ProSs can readily emerge and disappear over the course of protein evolution. Moreover, many ProSs may remain to be identified, which may account for the heterogeneity of the sequence conservation of IDRs.

60 APPLIED LIFE SCIENCES↗

Bayesian SegNet for Semantic Segmentation with Improved Interpretation of Microstructural Evolution During Irradiation of Materials

Understanding the relationship between the evolution of microstructures of irradiated LiAlO2pellets and tritium diffusion, retention and release could improve predictions of tritium performance. Given expert-labeled segmented images of irradiated and unirradiated pellets, we trained Deep Convolutional Neural Networks to segment images into defect, grain, and boundary classes. Qualitative microstructural information was calculated from these segmented images to facilitate the comparison of unirradiated and irradiated pellets. We tested modifications to improve the sensitivity of the model, including incorporating meta-data into the model and utilizing uncertainty quantification. The predicted segmentation was similar to the expert-labeled segmentation for most methods of microstructural qualification, including pixel proportion, defect area, and defect density. Overall, the high performance metrics for the best models for both irradiated and unirradiated images shows that utilizing neural network models is a viable alternative to expert-labeled images.

Oostrom, Marjolein T.↗

Evaluation of Automatic Atlas-Based Lymph Node Segmentation for Head-and-Neck Cancer

Purpose: To evaluate if automatic atlas-based lymph node segmentation (LNS) improves efficiency and decreases inter-observer variability while maintaining accuracy. Methods and Materials: Five physicians with head-and-neck IMRT experience used computed tomography (CT) data from 5 patients to create bilateral neck clinical target volumes covering specified nodal levels. A second contour set was automatically generated using a commercially available atlas. Physicians modified the automatic contours to make them acceptable for treatment planning. To assess contour variability, the Simultaneous Truth and Performance Level Estimation (STAPLE) algorithm was used to take collections of contours and calculate a probabilistic estimate of the 'true' segmentation. Differences between the manual, automatic, and automatic-modified (AM) contours were analyzed using multiple metrics. Results: Compared with the 'true' segmentation created from manual contours, the automatic contours had a high degree of accuracy, with sensitivity, Dice similarity coefficient, and mean/max surface disagreement values comparable to the average manual contour (86%, 76%, 3.3/17.4 mm automatic vs. 73%, 79%, 2.8/17 mm manual). The AM group was more consistent than the manual group for multiple metrics, most notably reducing the range of contour volume (106-430 mL manual vs. 176-347 mL AM) and percent false positivity (1-37% manual vs. 1-7% AM). Average contouring time savings with the automatic segmentation was 11.5 min per patient, a 35% reduction. Conclusions: Using the STAPLE algorithm to generate 'true' contours from multiple physician contours, we demonstrated that, in comparison with manual segmentation, atlas-based automatic LNS for head-and-neck cancer is accurate, efficient, and reduces interobserver variability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Morphometric Atlas Selection for Automatic Brachial Plexus Segmentation

Purpose: The purpose of this study was to determine the effects of atlas selection based on different morphometric parameters, on the accuracy of automatic brachial plexus (BP) segmentation for radiation therapy planning. The segmentation accuracy was measured by comparing all of the generated automatic segmentations with anatomically validated gold standard atlases developed using cadavers. Methods and Materials: Twelve cadaver computed tomography (CT) atlases (3 males, 9 females; mean age: 73 years) were included in the study. One atlas was selected to serve as a patient, and the other 11 atlases were registered separately onto this “patient” using deformable image registration. This procedure was repeated for every atlas as a patient. Next, the Dice and Jaccard similarity indices and inclusion index were calculated for every registered BP with the original gold standard BP. In parallel, differences in several morphometric parameters that may influence the BP segmentation accuracy were measured for the different atlases. Specific brachial plexus-related CT-visible bony points were used to define the morphometric parameters. Subsequently, correlations between the similarity indices and morphometric parameters were calculated. Results: A clear negative correlation between difference in protraction-retraction distance and the similarity indices was observed (mean Pearson correlation coefficient = −0.546). All of the other investigated Pearson correlation coefficients were weak. Conclusions: Differences in the shoulder protraction-retraction position between the atlas and the patient during planning CT influence the BP autosegmentation accuracy. A greater difference in the protraction-retraction distance between the atlas and the patient reduces the accuracy of the BP automatic segmentation result.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic Resonance–Based Automatic Air Segmentation for Generation of Synthetic Computed Tomography Scans in the Head Region

Purpose: To incorporate a novel imaging sequence for robust air and tissue segmentation using ultrashort echo time (UTE) phase images and to implement an innovative synthetic CT (synCT) solution as a first step toward MR-only radiation therapy treatment planning for brain cancer. Methods and Materials: Ten brain cancer patients were scanned with a UTE/Dixon sequence and other clinical sequences on a 1.0 T open magnet with simulation capabilities. Bone-enhanced images were generated from a weighted combination of water/fat maps derived from Dixon images and inverted UTE images. Automated air segmentation was performed using unwrapped UTE phase maps. Segmentation accuracy was assessed by calculating segmentation errors (true-positive rate, false-positive rate, and Dice similarity indices using CT simulation (CT-SIM) as ground truth. The synCTs were generated using a voxel-based, weighted summation method incorporating T2, fluid attenuated inversion recovery (FLAIR), UTE1, and bone-enhanced images. Mean absolute error (MAE) characterized Hounsfield unit (HU) differences between synCT and CT-SIM. A dosimetry study was conducted, and differences were quantified using γ-analysis and dose-volume histogram analysis. Results: On average, true-positive rate and false-positive rate for the CT and MR-derived air masks were 80.8% ± 5.5% and 25.7% ± 6.9%, respectively. Dice similarity indices values were 0.78 ± 0.04 (range, 0.70-0.83). Full field of view MAE between synCT and CT-SIM was 147.5 ± 8.3 HU (range, 138.3-166.2 HU), with the largest errors occurring at bone–air interfaces (MAE 422.5 ± 33.4 HU for bone and 294.53 ± 90.56 HU for air). Gamma analysis revealed pass rates of 99.4% ± 0.04%, with acceptable treatment plan quality for the cohort. Conclusions: A hybrid MRI phase/magnitude UTE image processing technique was introduced that significantly improved bone and air contrast in MRI. Segmented air masks and bone-enhanced images were integrated into our synCT pipeline for brain, and results agreed well with clinical CTs, thereby supporting MR-only radiation therapy treatment planning in the brain.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automated 3D cytoplasm segmentation in soft X-ray tomography

Cells’ structure is key to understanding cellular function, diagnostics, and therapy development. Soft X-ray tomography (SXT) is a unique tool to image cellular structure without fixation or labeling at high spatial resolution and throughput. Fast acquisition times increase demand for accelerated image analysis, like segmentation. Currently, segmenting cellular structures is done manually and is a major bottleneck in the SXT data analysis. This paper introduces ACSeg, an automated 3D cytoplasm segmentation model. ACSeg is generated using semi-automated labels and 3D U-Net and is trained on 43 SXT tomograms of immune T cells, rapidly converging to high-accuracy segmentation, therefore reducing time and labor. Furthermore, adding only 6 SXT tomograms of other cell types diversifies the model, showing potential for optimal experimental design. ACSeg successfully segmented unseen tomograms and is published on Biomedisa, enabling high-throughput analysis of cell volume and structure of cytoplasm in diverse cell types.

59 BASIC BIOLOGICAL SCIENCES↗

Arm and shoulder muscle segmentation in axial MRI with UNet deep learning model

Quantifying individual upper-limb muscle volumes from MRI provides key insight into muscle-specific strength, deficits, and adaptations. Manual delineation is the gold standard but time‑intensive, and the performance of current deep learning approaches, particularly for small or anatomically complex muscles, remains incompletely characterized. We evaluated a state‑of‑the‑art deep learning framework across the entire upper limb and analyzed factors governing segmentation performance, with attention to the forearm. Three previously published MRI datasets (1.5 T, 3D GRE T1‑weighted; total n = 39) spanning young, middle‑aged, and older adults were curated and quality‑checked, including expert manual segmentations for 31 muscles. Following multiclass mask reconstruction, we trained three 3D nnU‑Net multiclass models matched to the muscle subsets present across datasets, using five‑fold cross‑validation and a composite Dice Similarity Coefficient (DSC) + cross entropy loss. Segmentation accuracy was assessed with DSC. Performance varied across muscles (mean DSC = 0.806 ± 0.098), ranging from 0.920 (Deltoid) to 0.461 (Extensor pollicis brevis). In uncertainty‑weighted regressions, muscle volume was positively associated with DSC (R2 = 0.36, p < 0.001), whereas training segmentation count and muscle orientation showed negligible associations (R2 ≤ 0.06). A weighted mixed‑effects model identified volume as the strongest evaluated predictor, explaining 23.9% of variance in DSC; orientation and training count each contributed <1%, leaving 61.5% unexplained. These results indicate that deep learning–based segmentation can accurately quantify muscle volume for many upper‑limb muscles but remains constrained for small, low‑contrast forearm muscles.

Gillespie, Samuel↗

Define baseline levels of segments per beam for intensity-modulated radiation therapy delivery for brain, head and neck, thoracic, abdominal, and prostate applications

The purpose of this study was to evaluate the number of segments per beam for intensity-modulated radiation therapy (IMRT) treatments and its effects on the plan quality, treatment delivery time, machine quality assurance, and machine maintenance. We have retrospectively analyzed 24 patients treated with IMRT. Five were selected within each of the following regions: head and neck, thoracic, abdomen, and prostate. Four patients were optimized within the brain region. The clinically treated plans were re-optimized using Philips Pinnacle3 v. 8 with the direct machine parameter optimization algorithm. The number of segments per beam from the treated plan was systematically reduced by 80%, 60%, 40%, and 30%, and the following statistics have been analyzed for plan quality: target min, mean, and max doses; critical structure doses; and integral dose. We have attempted to define the smallest number of segments per beam for IMRT treatment plans. Results indicate that IMRT plans can be delivered with acceptable quality with approximately 3-6 segments per beam for the anatomical regions analyzed. A reduction in the number of segments decreases treatment delivery time, reduces machine wear and tear, and minimizes the amount of time the patient is on the treatment table, which in turn reduces the chances of intrafractional uncertainties.

61 RADIATION PROTECTION AND DOSIMETRY↗

Microphase separation in copolymers of hydrophilic PEG blocks and hydrophobic tyrosine-derived segments using simultaneous SAXS/WAXS/DSC

Hydration- and temperature-induced microphase separations were investigated by simultaneous small- and wide-angle X-ray scattering (SAXS and WAXS) and differential scanning calorimetry (DSC) in a family of copolymers in which hydrophilic poly(ethylene glycol) (PEG) blocks are inserted randomly into a hydrophobic polymer made of either desaminotyrosyl-tyrosine ethyl ester (DTE) or iodinated I{sub 2}DTE segments. Iodination of the tyrosine rings in I{sub 2}DTE increased the X-ray contrast between the hydrophobic and hydrophilic segments in addition to facilitating the study of the effect of iodination on microphase separation. The formation of phase-separated, hydrated PEG domains is of considerable significance as it profoundly affects the polymer properties. The copolymers of DTE (or I{sub 2}DTE) and PEG are a useful model system, and the findings presented here may be applicable to other PEG-containing random copolymers. In copolymers of PEG and DTE and I{sub 2}DTE, the presence of PEG depressed the glass transition temperature (T{sub g}) of the copolymer relative to the homopolymer, poly(DTE carbonate), and the DTE/I{sub 2}DTE segments hindered the crystallization of the PEG segments. In the dry state, at large PEG fractions (>70 vol%), the PEG domains self-assembled into an ordered structure with 14-18 nm distance between the domains. These domains gave rise to a SAXS peak at all temperatures in the iodinated polymers, but only above the T{sub g} in non-iodinated polymers, due to the unexpected contrast-match between the crystalline PEG domains and the glassy DTE segments. Irrespective of whether PEG was crystalline or not, immersion of these copolymers in water resulted in the formation of hydrated PEG domains that were 10-20 nm apart. Since both water and the polymer chains must be mobile for the phase separation to occur, the PEG domains disappeared when the water froze, and reappeared as the ice began to melt. This transformation was reversible, and showed hysteresis as did the melting of ice and freezing of the water incorporated into the polymer. PEG-water complexes and PEG-water eutectics were observed in WAXS and DSC scans, respectively.

36 MATERIALS SCIENCE↗