Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Scanning Electron Microscopes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Low-resistance noble metal contacts to high-temperature superconductors

Low-resistance contacts were made to both YBa2Cu3O(7-x) and Bi2BaSr2Cu2O8, and to related superconducting compounds by melting gold or silver pads onto the samples before the final oxygen treatment. Scanning electron microscope studies show that both gold and silver do not diffuse far from the contact area. The surface contact resistivity of the best contacts made by the melting technique has an upper limit value in the 10 to the -8th ohm sq cm range at 77 K. This contact resistivity shows no significant change in its value over a period of 17 months. Furthermore, an electron radiation dose of 5.7 x 10 to the 17th electron/sq cm only doubled the contact resistivity.

Selim, R.↗

Collectors Of Airborne And Spaceborne Particles

Brushlike collectors capture samples of dust and other particles in space vacuum or air for optical, scanning-electron-microscope, and/or x-ray analysis. Gently decelerates particles without damaging them, minimizing tendency of some particles to rebound. Depending on design of specific collector of this type, it captures particles ranging upward in size from fractions of micrometer to few micrometers.

Frazer, Robert E.↗

Development of mercuric iodide uncooled x ray detectors and spectrometers

The results obtained in the development of miniature, lowpower, light weight mercuric iodide, HgI2, x ray spectrometers for future space missions are summarized. It was demonstrated that HgI2 detectors can be employed in a high resolution x ray spectrometer, operating in a scanning electron microscope. Also, the development of HgI2 x ray detectors to augment alpha backscattering spectrometers is discussed. These combination instruments allow for the identification of all chemical elements, with the possible exception of hydrogen, and their respective concentrations. Additionally, further investigations of questions regarding radiation damage effects in the HgI2 x ray detectors are reported.

Iwanczyk, Jan S.↗

Matrix fatigue crack development in a notched continuous fiber SCS-6/Ti-15-3 composite

In this study the extensive matrix fatigue cracking that has been observed in notched SCS-6/Ti-15-3 composites is investigated. Away from the notch a uniform spacing of the fatigue cracks develops. Closer to the notch, fiber-matrix debonding which occurs increases the crack spacing. Crack spacing and debond length determined from shear-lag cylinder models compare favorably with experimental observations. Scanning electron microscope (SEM) fractography showed that the principal fatigue crack initiation occurred around the zero degree fibers. Interface failure in the 90 degree plies does not lead to the development of the primary fatigue cracking.

Hillberry, B. M.↗

SIMS analysis of extended impact features on LDEF experiment

Discussed here are the first Secondary Ion Mass Spectroscopy (SIMS) analysis of projectile material deposited in extended impact features on Ge wafers from the trailing edge. Although most capture cells lost their plastic film covers, they contain extended impact features that apparently were produced by high velocity impacts when the plastic foils were still intact. Detailed optical scanning of all bare capture cells from the trailing edge revealed more than 100 impacts. Fifty-eight were selected by scanning electron microscope (SEM) inspection as prime candidates for SIMS analysis. Preliminary SIMS measurements were made on 15 impacts. More than half showed substantial enhancements of Mg, Al, Si, Ca, and Fe in the impact region, indicating micrometeorites as the projectiles.

Amari, S.↗

Chemical analysis of metal and polymer surfaces on the front and rear LDEF

The University of Alabama in Huntsville experiment AO114 contained 128 solid surface samples, half of which were exposed on the front and half on the rear of the Long Duration Exposure Facility (LDEF). Each sample is being subject to a battery of analysis methods. In poster form, details of the x-ray photoelectron spectra, Auger electron spectra, Fourier Transform Infrared and ATR infrared spectra, high resolution profilometry, and scanning electron microscope imagery will be presented from a selection of metal and non-metal surfaces.

Christi, L.↗

Results of examination of silvered Teflon from the Long Duration Exposure Facility

Pieces of silvered Teflon thermal control blanket from seventeen locations on the Long Duration Exposure Facility (LDEF) were studied. Results of the measurements of surface texturing, and mechanical, electrical and thermal properties are presented. Photos of the blankets, scanning electron microscope pictures, infrared spectra, and surface analysis results are presented. Contamination issues relative to performance of the blankets are discussed. The variation in measured properties are reported as a function of exposure conditions.

Rousslang, Ken W.↗

Volatile-bearing phases in carbonaceous chondrites: Compositions, modal abundance, and reaction kinetics

The spectral and density characteristics of Phobos and Deimos (the two small natural satellites of Mars) strongly suggest that a significant fraction of the near-earth asteroids are made of carbonaceous chondrites, which are rich in volatile components and, thus, could serve as potential resources for propellants and life supporting systems in future planetary missions. However, in order to develop energy efficient engineering designs for the extraction of volatiles, knowledge of the nature and modal abundance of the minerals in which the volatiles are structurally bound and appropriate kinetic data on the rates of the devolatilization reactions is required. Theoretical calculations to predict the modal abundances and compositions of the major volatile-bearing and other mineral phases that could develop in the bulk compositions of C1 and C2 classes (the most volatile rich classes among the carbonaceous chondrites) were performed as functions of pressure and temperature. The rates of dehydration of talc at 585, 600, 637, and 670 C at P(total) = 1 bar were determine for the reaction: Talc = 3 enstatite + quartz + water. A scanning electron microscopic study was conducted to see if the relative abundance of phases can be determined on the basis of the spectral identification and x ray mapping. The results of this study and the other studies within the project are discussed.

Ganguly, Jibamitra↗

Moessbauer spectroscopy and scanning electron microscopy of the Murchison meteorite

Meteorites provide a wealth of information about the solar system's formation, since they have similar building blocks as the Earth's crust but have been virtually unaltered since their formation. Some stony meteorites contain minerals and silicate inclusions, called chondrules, in the matrix. Utilizing Moessbauer spectroscopy, we identified minerals in the Murchison meteorite, a carbonaceous chondritic meteorite, by the gamma ray resonance lines observed. Absorption patterns of the spectra were found due to the minerals olivine and phyllosilicate. We used a scanning electron microscope to describe the structure of the chondrules in the Murchison meteorite. The chondrules were found to be deformed due to weathering of the meteorite. Diameters varied in size from 0.2 to 0.5 mm. Further enhancement of the microscopic imagery using a digital image processor was used to describe the physical characteristics of the inclusions.

Brown, Christopher L.↗

Effect of grinding conditions on the fatigue life of titanium 5Al-2.5Sn alloy

An investigation into the effect of grinding conditions on the fatigue life of titanium 5Al-2.5Sn is presented. Damage to surface integrity and changes in the residual stresses distribution are studied to assess changes in fatigue life. A surface grinding machine, operating at speeds ranging from 2000 to 6000 fpm and using SiC wheels of grit sizes 60 and 120, was used to grind flat subsize specimens of 0.1-in. thickness. After grinding, the specimens were fatigued at a chosen stress and compared with the unadulterated material. A standard profilometer, a microhardness tester, and a scanning electron microscope were utilized to examine surface characteristics and measure roughness and hardness. Increased grinding speed in both wet and dry applications tended to decrease the fatigue life of the specimens. Fatigue life increased markedly at 2000 fpm under wet conditions, but then decreased at higher speeds. Grit size had no effect on the fatigue life.

Rangaswamy, P.↗

HP9-4-.30 weld properties and microstructure

HP9-4-.30, ultra high strength steel, the case material for the Advanced Solid Rocket Motor (ASRM), must exhibit acceptable strength, ductility, toughness, and stress corrosion cracking (SCC) resistance after welding and a local post weld heat treatment (PWHT). Testing, to date, shows that the base metal (BM) properties are more than adequate for the anticipated launch loads. Tensile tests of test specimens taken transverse to the weld show that the weld metal overmatches the BM even in the PWHT condition. However, that is still some question about the toughness and SCC resistance of the weld metal in the as welded and post weld heat treated condition. To help clarify the as welded and post weld heat treated mechanical behavior of the alloy, subsize tensile specimens from the BM, the fusion zone (FZ) with and without PWHT, and the heat affected zone (HAZ) with and without PWHT were tested to failure and the fracture surfaces subsequently examined with a scanning electron microscope. Results are given and briefly discussed.

Watt, George W.↗

Analysis of particulate contamination on tape lift samples from the VETA optical surfaces

Particulate contamination analysis was carried out on samples taken from the Verification Engineering Test Article (VETA) x-ray detection system. A total of eighteen tape lift samples were taken from the VETA optical surfaces. Initially, the samples were tested using a scanning electron microscope. Additionally, particle composition was determined by energy dispersive x-ray spectrometry. Results are presented in terms of particle loading per sample.

Germani, Mark S.↗

Chemical compatibility of cartridge materials

This twelve month progress report deals with the chemical compatibility of semiconductor crystals grown in zero gravity. Specifically, it studies the chemical compatibility between TZM, a molybdenum alloy containing titanium and zirconium, and WC 103, a titanium alloy containing Niobium and Hafnium, and Gallium arsenide (GaAs) and Cadmium Zinc Tellurite (CdZnTe). Due to the health hazards involved, three approaches were used to study the chemical compatibility between the semiconductor and cartridge materials: reaction retort, thermogravimetric analysis, and bulk cylindrical cartridge containers. A scanning electron microscope with an energy dispersive X-ray analyzer was used to examine all samples after testing. The first conclusion drawn is that reaction rates with TZM were not nearly as great as they were with WC 103. Second, the total reaction between GaAs and WC 103 was almost twice that with TZM. Therefore, even though WC 103 is easier to fabricate, at least half of the cartridge thickness will be degraded if contact is made with one of the semiconductor materials leading to a loss of strength properties.

Wilcox, Roy C.↗

Vacuum Ultraviolet (VUV) radiation-induced degradation of Fluorinated Ethylene Propylene (FEP) Teflon aboard the Long Duration Exposure Facility (LDEF)

Examination of fluorinated ethylene propylene (FEP) copolymer specimens recovered from the Long Duration Exposure Facility (LDEF) provides evidence for degradation attributed to extended solar vacuum ultraviolet (VUV) irradiation. Scanning electron microscope (SEM) images of sheared FEP film edges reveal the presence of a highly embrittled layer on the exposed surface of specimens obtained from the trailing edge of the LDEF. Similar images obtained for leading edge and control FEP films do not exhibit evidence for such an embrittled layer. Laboratory VUV irradiation of FEP films is found to produce a damage layer similar to that witnessed in the LDEF trailing edge films. Spectroscopic analyses of irradiated films provide data to advance a photochemical mechanism for degradation.

Brinza, David E.↗

LDEF SP-HVDE (Space Plasma-High Voltage Drainage Experiment) post-flight results: Leakage current and discharge

TRW designed and fabricated two identical SP-HVDE trays which were flown in the NASA LDEF (Long Duration Exposure Facility) for 5.75 years in the LEO (low earth orbit) environment. One tray was placed near the leading edge and one near the trailing edge, and investigations were performed to compare the environmental interactions on the dielectric samples of the two trays. Each tray consisted of six assemblies with Kapton dielectric samples of varying thicknesses (i.e., 2 mils, 3 mil, and 5 mils) biased under +/- 300 V, +/- 500 V, and +/- 1000 V. The original objective was successfully achieved by measuring the first in-flight average leakage current through the samples. Less than 5 percent of the post-flight coulometers behaved anomalously. The data should be valuable to the design and evaluation of spacecraft with high voltage systems. M/D (micrometeoroid and debris) impacts over the dielectric samples were examined using a SEM (Scanning Electron Microscope) and an EDS (Energy Dispersive x-ray Spectrometer). These impact sites were sprayed by silver which were most likely caused either by the impact or a 'local ESD' (electrostatic discharge).

Yaung, J. Y.↗

LDEF polymeric materials: 10 months versus 5.8 years of exposure

The chemical characterization of several polymeric materials which received both 10 months and 5.8 years of exposure on a Row 9 experiment (A0134) is reported. Specimens include polysulfone film, polysulfone matrix/graphite-fiber reinforced composites, and coated and uncoated epoxy matrix/graphite fiber reinforced composites. The effect of 10 months of exposure on an experimental silicon-containing polyimide copolymer film is also reported. The results of infrared, thermal, x-ray photoelectron, and scanning electron microscope analyses will be compared for the two exposures. Solution property measurements on the thermoplastic polysulfone resin will also be presented. Molecular level effects attributable to exposure and present in 10-month specimens are not present in 5.8-year specimens. This suggests that increased atomic oxygen fluence toward the end of the mission may have eroded selected environmentally-induced changes in surface chemistry for 5.8-year specimens.

Young, Philip R.↗

Type I polar stratospheric cloud particles - Concentration, shape, size, light extinction

Results from the flight on January 24, 1989 of the Airborne Arctic Stratospheric Experiment during which the ER-2 aircraft transitioned from unsaturated to ice saturated air at 20 km altitude are presented. Aerosol particles were sampled by wire impactors and examined for number density as a function of particle size by taking photomicrographs in a scanning electron microscope and visually sizing and counting the particles. Differences in the chemical, physical and optical properties of stratospheric aerosol between ice-saturated and nonsaturated air are described.

Pueschel, R. F.↗

Compression, bend, and tension studies on forged Al67Ti25Cr8 and Al66Ti25Mn(g) L1(2) compounds

Cast, homogenized, and isothermally forged aluminum-rich L1(2) compounds Al67Ti25Cr8 and Al66Ti25Mn(g) were tested in compression as a function of temperature and as a function of strain rate at elevated temperatures (1000 K and 1100 K). Three-point bend specimens were tested as a function of temperature in the range 300 K to 873 K. Strain gages glued on the tensile side of the ambient and 473 K specimens enabled direct strain measurements. A number of 'buttonhead' tensile specimens were electro-discharge machined, fine polished, and tested between ambient and 1073 K for yield strength and ductility as a function of temperature. Scanning electron microscope (SEM) examination of fracture surfaces from both the bend and tensile specimens revealed a gradual transition from transgranular cleavage to intergranular failure with increasing temperature.

Kumar, K. S.↗