Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Saturation problem”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

310 records · Page 18

Exploration of relationships between low-Ti and high-Ti pristine lunar glasses using an armalcolite assimilation model

The pristine glasses of Delano are the most primitive lunar basaltic magma compositions discovered to date. They are grouped into two (and possibly three) arrays: a low-alumina array and a high alumina array. These glasses are very olivine normative and are multiply saturated at pressures of approximately 20 kbar, implying a depth of origin of 400 to 500 km in the Moon. Thus, these glasses appear to be the best candidates for primitive partial melts of the upper lunar mantle. One of the most perplexing characteristics of the pristine glasses is a positive correlation between Ni and SiO2 within each array. This is contrary to the terrestrial experience, where Ni is observed to positively correlate with MgO and negatively correlate with SiO2. These systematics are believed to be due to the depletion of Ni by olivine fractionation. The difference between the lunar and terrestrial Ni vs. SiO2 trends may be partially ascribed to the Ti-rich component. In the case of the pristine glasses, SiO2 increases not because of olivine fractionation, but because they contain less of the high-Ti component. An attempt was made to model this variation in Ni and SiO2 with a simple assimilation-fractional crystallization (AFC) model. Silica and Ni both decreased dramatically as the AFC process proceeded. Only 15 to 20 percent AFC was necessary to produce the observed variation, and the SiO2 vs. Ni variation was modeled quite well. The D(Ni) for olivine/liquid in this model was taken to be 10 and the olivine was assumed to be Fe sub 80. However, the results of this model for Ti and Mg were less than satisfactory. It seemed difficult to achieve the high TiO2 contents of some glasses (16 to 17 wt. percent) by this method. Continual addition of ilmenite by AFC could indeed raise the titania concentrations to the necessary levels, but only by enriching the magma in FeO and greatly depleting the magma in MgO. An attempt was made to circumvent this problem by using armalcolite, (Fe, Mg)Ti2O5, in the AFC model, and the results are presented.

Jones, John H.↗

The Combined Detection of Morphological and Molecular Biomarkers: Implications for Astrobiology

Experience gathered by previous researchers during their hunt for evidence of early Earth life has shown the complexity in interpreting observations of possible microfossils and to establish the evidence to be positive. Similarly, the stillsimmering controversy on the nature of the nano-structures in Martian meteorite ALH84001 described by McKay et al. (1996) emphasizes the difficulties of conclusively identifying those structures as (a) fossilized bacterial cells and (b) establish their indigeneity. A better understanding of biological signatures in rocks is needed in order to identify traces of microbial life, which include morphological, mineralogical and chemical traces. It is thus considered crucial to tackle the problems emerging in the search for evidence of early life on Earth and in exopaleontological research with a multidisciplinary approach. With this is mind we applied surface sensitive Time of Flight-Secondary Ion Mass Spectroscopy (ToF-SIMS) to a previously described 25 m.y. old fossil bacterial biofilm. This technique allows in situ analysis with high mass resolution as well as molecular imaging of micron sized structures. As no extraction or derivatisation of the sample is required for ToF-SIMS analysis, electron microscopical investigation of the same samples subsequent to analysis is possible, thus allowing the combination of molecular and morphological biomarkers. The analysed fossil bacterial biofilms were associated with macrofossils from volcanoclastic lacustrine sediments from the Upper Oligocene Enspel formation (Germany). Preliminary scanning electron microscopy (SEM) studies have shown that a fossil structure interpreted as a coprolite purely consisted of fossilized bacterial biofilm. For ToF-SIMS investigation small particles were taken from the fossil biofilm and mounted onto Au-coated In-foil and analysed in a Phi Evans T-2000 TRIFT system. The ToF-SIMS analysed samples were Au/Pd-sputter coated and imaged using a Philips XL40 Field Emission Gun SEM (FEG-SEM). ToF-SIMS analysis of the organic rich fossil biofilm (TOC 29%) in the 0-100 Dalton (Da) range showed significant amounts of inorganic species, confirming the results obtained previously by EDX analysis, clearly showing the bacterial fossils to be mineralised. ToF-SIMS furthermore revealed the presence of a variety of low- and high-mass organic molecules and fragments thereof. These include peaks indicative of alkenes and alkanes, aromatic organic species and the polycyclic aromatic hydrocarbon naphthalene. More tentatively, peaks indicative of alkyl pyrroles and pyridyl-CH2 were identified. Other peaks of interest include peaks indicative of C(n)H(2n)O2 and C(n)H(2n-2)O2, which according to their general formula would suggest the presence of both saturated and unsaturated fatty acids although further in situ derivatisation experiments and GC-MS (Gas Chromatography MS) need to be applied to verify this beyond doubt. Furthermore, peaks at m/z 370, 384, 398, 412, 426, 440, 454 and 468 were identified, which indicate the potential presence of bacterial hopanes, a class of biomarkers indicative of bacteria. The main diagnostic peak for this group of chemicals is the fragment at m/z 191.18. Our studies conducted on purified hopane standards have shown that in the high-mass resolution mode differentiation of this diagnostic hopane peak and polyethylene at m/z 191.05 is possible. However, the spectra discussed here were collected in the lower resolution mapping mode, therefore this differentiation was not possible. The centroids of the possible hopane peaks obtained on the fossil biofilms are well within the range associated with bacterial hopanes. There is a strong possibility therefore that hopanoids may be associated with the fossil bacterial cells. Due to the non-destructive nature of ToF-SIMS, analysed samples can be studied using SEM, thus allowing the combination of morphological and molecular biomarkers. Subsequent SEM analysis of the ToF-SIMS analysed samples confirmed that the analysed material purely consists of fossil bacterial cells. This is thus the first successful effort to demonstrate the combination of spectral and morphological biomarkers. The advantages of highly sensitive non-destructive in situ analysis techniques for biomarker detection are invaluable, particularly with respect to envisaged Mars sample return missions, as it may allow us to identify remains and traces of former microbial life in both ancient terrestrial and extraterrestrial materials. This technique may prove particularly useful in the quest for extraterrestrial life with respect to precious extraterrestrial materials, as minute quantities are sufficient to conduct analysis.

Toporski, J.↗

Masking of photovoltaic system performance problems by inverter clipping and other design and operational practices

We describe how performance problems can be “masked,” or not readily evident by several causes: by photovoltaic (PV) system configuration (such as the size of the PV array capacity relative to the size of the inverter and the resultant clipped operating mode); by instrumentation design, installation, and maintenance (such as a misaligned or dirty pyranometer); by contract clauses (when operational availability is transformed to contractual availability, which excludes many factors); and by identified management and operational practices (such as reporting on a portfolio of plants rather than individually). A simple method based on a duration curve is introduced to overcome shortcomings of Performance Ratio based on nameplate capacity and Performance Index based on hourly simulation when quantifying masking effects, and inverter clipping and pyranometer soiling are presented as two examples of the new method. With a better understanding of the non-transparency of masking issues, stakeholders can better interpret performance data and deliver improved AC and DC plant conditions through PV system operation and maintenance (O&M) for improved performance, reduced O&M costs, and a more consistently delivered, and reduced, levelized cost of energy (LCOE).

14 SOLAR ENERGY↗

Coupling to rotational manifolds to improve gas-phase pump–probe spectroscopic models

The physical picture of gas-phase optical transitions is normally presented as an isolated two-level system balanced by upward and downward processes. Isolated models assume a phenomenological treatment of collisional dephasing but do not strictly account for collisional population exchange with the rotational baths. While this assumption is valid under low-intensity conditions, where excitation is rate-limiting, isolated models can deviate from Beer’s Law at sufficient pressures and monochromatic intensities when both collisional broadening and power broadening are comparable to (or greater than) lifetime broadening, which are not uncommon conditions for cavity enhanced spectroscopies in the mid-IR spectral range. Although this problem has been addressed by rate-equation models for linear absorption measurements, a general treatment for multi-level quantum mechanical models suitable for non-linear absorption measurements (two-photon/two-color/pump–probe) is lacking. Isolated models require physical parameter inputs that disagree with expected values by at least an order of magnitude. These non-physical models undermine the ability to predict non-linear signal strengths under untested conditions and thereby limit the potential to optimize the sensitivity of non-linear spectroscopies and to expand their analytical applications (e.g., new analytes and/or buffer gases, changes in cavity free-spectral-range, changes in intracavity powers or wavelengths, and accurate investigation of physical phenomena). In this study, we derive bath-coupled models for gaseous pump–probe spectroscopy by application of the quantum Lindblad equation and detailed balance. Bath-coupled models are shown to fit data consistently across variations in intensity and agree with all physically expected values.

Cavity ring-down spectroscopy↗