SEARCH · Engineering Papers
Results for “Sample Handling”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
redMaPPer. I. Algorithm and SDSS DR8 catalog
We describe redMaPPer, a new red sequence cluster finder specifically designed to make optimal use of ongoing and near-future large photometric surveys. The algorithm has multiple attractive features: (1) it can iteratively self-train the red sequence model based on a minimal spectroscopic training sample, an important feature for high-redshift surveys. (2) It can handle complex masks with varying depth. (3) It produces cluster-appropriate random points to enable large-scale structure studies. (4) All clusters are assigned a full redshift probability distribution P(z). (5) Similarly, clusters can have multiple candidate central galaxies, each with corresponding centering probabilities. (6) The algorithm is parallel and numerically efficient: it can run a Dark Energy Survey-like catalog in ∼500 CPU hours. (7) The algorithm exhibits excellent photometric redshift performance, the richness estimates are tightly correlated with external mass proxies, and the completeness and purity of the corresponding catalogs are superb. We apply the redMaPPer algorithm to ∼10, 000 deg{sup 2} of SDSS DR8 data and present the resulting catalog of ∼25,000 clusters over the redshift range z in [0.08, 0.55]. The redMaPPer photometric redshifts are nearly Gaussian, with a scatter σ {sub z} ≈ 0.006 at z ≈ 0.1, increasing to σ {sub z} ≈ 0.02 at z ≈ 0.5 due to increased photometric noise near the survey limit. The median value for |Δz|/(1 + z) for the full sample is 0.006. The incidence of projection effects is low (≤5%). Detailed performance comparisons of the redMaPPer DR8 cluster catalog to X-ray and Sunyaev-Zel'dovich catalogs are presented in a companion paper.
HHL algorithm with mapping function and enhanced sampling for model predictive control in microgrids
Here, this paper presents a refined quantum Harrow Hassidim Lloyd (HHL) algorithm for microgrid control. The first novelty of the developed method is that a mapping shift function enables the original HHL algorithm to handle general linear equations with non-singular and indefinite matrix. Second, a method of Matrix Extension for Amplifying Sampling Probabilities of Intended Solution (ME-ASPI) is proposed to design the reformulated linear algebraic equations, allowing for improved sampling efficiency of the quantum tomography in the refined HHL algorithm. Then, we applied the method to solve the model predictive control (MPC) problem in nonlinear dynamical microgrids. Specifically, with the ME-ASPI method, the refined HHL algorithm can effectively obtain the intended partial optimal control inputs for MPC. The optimization of quadratic programming problem in each time step of MPC is transformed into a linear system problem, which is addressed by the proposed quantum solver through using only partial information, with the time complexity improved from $\mathscr{O}(\mathscr{N}^{2.37286})$ classically to $\mathscr{O}(\mathscr{N}^{2} log \mathscr{N}$ x $p$ log $p)$ in quantum. Numerical examples have validated the effectiveness of the refined HHL algorithm with the proposed mapping function and the ME-ASPI method. By leveraging quantum properties, the proposed method provides a hybrid quantum–classical framework for microgrid control. This generic method can also potentially tackle many other challenges in analyzing and controlling general complex engineered systems.
Sputter sample preparation for ion beam delivery of radium-223 at ATLAS
A radium-223 ion beam was delivered to an experiment from the electron cyclotron resonance ion source, ECR2, at the Argonne Tandem Linac Accelerator System (ATLAS). Here, the radium-223 material was in a nitrate salt form within a vial, prior to being converted to a usable sputter sample. The sputter sample was produced using a new sample preparation method, where the radium nitrate was dissolved into a solution and pipetted onto pressed aluminum powder. This sample was then allowed to dry, distributing the radium-223 material throughout the sputter sample. Ion source operation using the radium sputter sample is described with the operating parameters listed. The intensity and energy requirements for this ion beam were 1 × 10 6 particles/s and 1.07 GeV, respectively. Because the intensity is relatively low compared to most experiments at ATLAS, previously developed accelerator mass spectrometry methods were used Scott et al. to avoid the need for tuning of the low-intensity beam of interest. Handling of the radium material, as well as loading and unloading of the sputter sample from ECR2, required collaboration with Health Physics. Procedures were used and dry runs were carried out before, during, and after the experiment to ensure the safety of the workers. The processes used and lessons learned are described within.
BEYONDPLANCK II. CMB mapmaking through Gibbs sampling
We present a Gibbs sampling solution to the mapmaking problem for cosmic microwave background (CMB) measurements that builds on existing destriping methodology. Gibbs sampling breaks the computationally heavy destriping problem into two separate steps: noise filtering and map binning. Considered as two separate steps, both are computationally much cheaper than solving the combined problem. This provides a huge performance benefit as compared to traditional methods and it allows us, for the first time, to bring the destriping baseline length to a single sample. Here, we applied the Gibbs procedure to simulated Planck 30 GHz data. We find that gaps in the time-ordered data are handled efficiently by filling them in with simulated noise as part of the Gibbs process. The Gibbs procedure yields a chain of map samples, from which we are able to compute the posterior mean as a best-estimate map. The variation in the chain provides information on the correlated residual noise, without the need to construct a full noise covariance matrix. However, if only a single maximum-likelihood frequency map estimate is required, we find that traditional conjugate gradient solvers converge much faster than a Gibbs sampler in terms of the total number of iterations. The conceptual advantages of the Gibbs sampling approach lies in statistically well-defined error propagation and systematic error correction. This methodology thus forms the conceptual basis for the mapmaking algorithm employed in the BEYONDPLANCK framework, which implements the first end-to-end Bayesian analysis pipeline for CMB observations.
Efficient distributed continual learning for steering experiments in real-time
Deep learning has emerged as a powerful method for extracting valuable information from large volumes of data. However, when new training data arrives continuously (i.e., is not fully available from the beginning), incremental training suffers from catastrophic forgetting (i.e., new patterns are reinforced at the expense of previously acquired knowledge). Training from scratch each time new training data becomes available would result in extremely long training times and massive data accumulation. Rehearsal-based continual learning has shown promise for addressing the catastrophic forgetting challenge, but research to date has not addressed performance and scalability. To fill this gap, we propose an approach based on a distributed rehearsal buffer that efficiently complements data-parallel training on multiple GPUs to achieve high accuracy, short runtime, and scalability. It leverages a set of buffers (local to each GPU) and uses several asynchronous techniques for updating these local buffers in an embarrassingly parallel fashion, all while handling the communication overheads necessary to augment input minibatches using unbiased, global sampling. We further propose a generalization of rehearsal buffers to support both classification and generative learning tasks, as well as more advanced rehearsal strategies (notably Dark Experience Replay, leveraging knowledge distillation). We illustrate this approach with a real-life HPC streaming application from the domain of ptychographic image reconstruction. Furthermore, we run extensive experiments on up to 128 GPUs of the ThetaGPU supercomputer to compare our approach with baselines representative of training-from-scratch (the upper bound in terms of accuracy) and incremental training (the lower bound). Results show that rehearsal-based continual learning achieves a top-5 validation accuracy close to the upper bound, while simultaneously exhibiting a runtime close to the lower bound.
Deposition of sulfate aerosols with positive Δ 33 S in the Neoarchean
Anomalous sulfur isotope compositions present in Archean rocks have been intensely scrutinized over the last 20 years because they record key aspects of Earth's atmospheric composition prior to the appearance of free molecular oxygen ca. 2.3 billion years ago. These isotopic compositions can be described as mass anomalous fractionations (MAF) and are produced in the atmosphere as UV light interacts with SO 2 molecules. Most interpretations suggest that atmospheric processes generate a reduced S-phase with a positive ( 33 S-enriched) MAF signature, as measured in pyrites, and an oxidized S-phase with a negative anomaly, as measured in bedded barite deposits. However, recent data for carbonate-associated sulfate (CAS) — a direct proxy for the isotopic composition of sulfur from seawater sulfate — in Neoarchean rocks showed no such negative values, but rather the opposite. To understand if the positive MAF anomalies we measured in Neoarchean CAS reflect secondary processes (diagenetic, metamorphic, handling) instead of original signals of Archean seawater sulfate, we collected additional sample suites with various degrees of preservation and metamorphic alteration across the Campbellrand-Malmani platform in South Africa. Results illustrate that within this comprehensive suite, less-altered samples all contain positive MAF values while secondary processes tend to either remove CAS from the sample and/or decrease the 33 S-enrichment. This positive MAF signal in sulfate is therefore reasonably interpreted as a primary depositional origin, and implies that the assumption that sulfate always carries a negative MAF anomaly throughout the Archean rock record needs to be reconsidered. Our CAS observations suggest that future experiments and calculations should also consider atmospheric and/or sulfur cycling processes that can produce oxidized sulfur with a positive MAF signature.
SU-E-T-400: Evaluation of Shielding and Activation at Two Pencil Beam Scanning Proton Facilities
Purpose: To verify acceptably low dose levels around two newly constructed identical pencil beam scanning proton therapy facilities and to evaluate accuracy of pre-construction shielding calculations. Methods: Dose measurements were taken at select points of interest using a WENDI-2 style wide-energy neutron detector. Measurements were compared to pre-construction shielding calculations. Radiation badges with neutron dose measurement capabilities were worn by personnel and also placed at points throughout the facilities. Seven neutron and gamma detectors were permanently installed throughout the facility, continuously logging data. Potential activation hazards have also been investigated. Dose rates near water tanks immediately after prolonged irradiation have been measured. Equipment inside the treatment room and accelerator vault has been surveyed and/or wipe tested. Air filters from air handling units, sticky mats placed outside of the accelerator vault, and water samples from the magnet cooling water loops have also been tested. Results: All radiation badges have been returned with readings below the reporting minimum. Measurements of mats, air filters, cooling water, wipe tests and surveys of equipment that has not been placed in the beam have all come back at background levels. All survey measurements show the analytical shielding calculations to be conservative by at least a factor of 2. No anomalous events have been identified by the building radiation monitoring system. Measurements of dose rates close to scanning water tanks have shown dose rates of approximately 10 mrem/hr with a half-life less than 5 minutes. Measurements around the accelerator show some areas with dose rates slightly higher than 10 mrem/hr. Conclusion: The shielding design is shown to be adequate. Measured dose rates are below those predicted by shielding calculations. Activation hazards are minimal except in certain very well defined areas within the accelerator vault and for objects placed directly in the path of the beam.
Development of Ultra Small Scale Mechanical Testing and Localized He Implantation for Nuclear Applications
Mechanical properties degradation of components deployed in nuclear applications has been a concern since the deployment of first generation nuclear power plants. Radiation damage along with environmental degradation, elevated temperatures, and long term deployment of nuclear structures pose a challenging environment for all materials in these applications. Traditionally, the mechanical properties are assessed by standardized macroscopic testing methods. While those are providing engineering relevant data these techniques do have limitations, especially on reactor irradiated materials, due to the large size of the samples. Limitations on the amount of radioactivity of large samples must be applied for research applications as they are conducted at universities. In addition it can be difficult to retrieve sufficiently large amounts of material from an operating reactor component. Therefore smaller sample sizes are desirable and reduce the amount of radioactive material which needs to be handled or material which needs to be retrieved. In addition, the number of tests which can be performed on materials irradiated in a test reactor program is limited due to limited space in specific dose and temperature positions. Downsizing of the mechanical test can overcome this issue and perform more tests on the same amount of irradiated materials, reducing the statistical uncertainties. In addition, smaller scale samples allow access to specific regions of interest in a material or component, be it the zone in front of a crack tip or the sampling of very small components like springs or welded areas. In addition ion beam irradiation has become an integral part of nuclear materials research to enhance the understanding of radiation damage in materials in a time and cost effective fashion. The drawback of ion beam irradiation is the small penetration depth of the ions into the material making localized microstructural characterization as well as small scale mechanical testing necessary. Another more fundamental motivation is the fact that since the beginning of electron microscopy, one has been concerned about imaging and quantifying defects in materials. Multiscale tools to image a large range of radiation induced defects have been established starting from atom probe tomography to transmission electron microscopy, up to scattering techniques. Mechanical testing, however, has always been performed on a large scale, and an attempt to match the same scale where a defect is observed with the materials' mechanical property response has not yet been realized. However, the question of separate effects testing on specific radiation induced defects remains and is an additional driving force for small scale mechanical testing. In this work we present an approach for small scale mechanical testing in irradiated materials and the variety of possible test methods developed today. We also present recent efforts of performing localized ion beam implantation to achieve a number of different doses in the same region of interest enhancing comparability and quantification of observed phenomena. It is the intention to give the reader an overview of the different microscale mechanical testing techniques possible today as well as an introduction of a novel ion beam irradiation method using a newly established capability. In this paper we can't discuss all aspects of all small scale mechanical testing of irradiated materials However, It does give an overview over the techniques enabled due to recent effort and enhanced instrument capability. While indentation or micro compression testing has been performed previously tensile testing and ion beam irradiation using the He ion beam microscope are novel approaches not attempted previously. (authors)
Submersible ROVs pioneer decommissioning of a legacy nuclear fuel storage pond - 15368
Submersible Remote Handling Vehicles (ROVs) are being used in innovative ways at the Sellafield decommissioning, reprocessing and nuclear waste management facility in the UK in a legacy fuel storage pond in support of pond decommissioning. A wide range of sensors and tooling attached to submersible ROVs are being used to characterise the contents of the pond and perform a wide range of maintenance and material retrieval tasks. Visual surveys, sludge and liquor sampling and radiological surveys are just some of the characterisation projects undertaken with the help of the ROVs. The ROVs have also been deployed with tooling including manipulators which can retrieve debris from the pond floor. A variety of mini and work class ROVs are used in the ponds and these can access areas of the pond that the traditional technologies such as long reach tooling and manipulators from overhead cranes cannot reach safely, efficiently and cost effectively. The ROVs are controlled at a distance from the pond to minimise operator exposure to radiation and avoid potential radiological contamination. (authors)
Dynamical mean field theory simulations with the adaptive sampling configuration interaction method
In the pursuit of accurate descriptions of strongly correlated quantum many-body systems, dynamical mean field theory (DMFT) has been an invaluable tool for elucidating the spectral properties and quantum phases of both phenomenological models and ab initio descriptions of real materials. Key to the DMFT process is the self-consistent map of the original system into an Anderson impurity model, the ground state of which is computed using an impurity solver. The power of the method is thus limited by the complexity of the impurity model the solver can handle. Simulating realistic systems generally requires many correlated sites. By adapting the recently proposed adaptive sampling configuration interaction (ASCI) method as an impurity solver, we enable much more efficient zero-temperature DMFT simulations. The key feature of the ASCI method is that it selects only the most relevant Hilbert space degrees of freedom to describe the ground state. This reduces the numerical complexity of the calculation, which will allow us to pursue future DMFT simulations with more correlated impurity sites than in previous works. Here, we present the ASCI-DMFT method and example calculations on the one- and two-dimensional Hubbard models that exemplify its efficient convergence and timing properties. We show that the ASCI approach is several orders of magnitude faster than the current best published ground-state DMFT simulations, which allows us to study the bath discretization error in simulations with small clusters, as well as to address cluster sizes beyond the current state of the art. Finally, our approach can also be adapted for other embedding methods such as density matrix embedding theory and self-energy embedding theory.
Observation of second harmonic generation in doped polymeric carbon monoxide
Abstract not provided
Interpreting T-History Data on Supercooling and Phase Change Enthalpy of a Salt-Hydrogel Complex for Building Thermal Management
Phase change materials (PCMs) are promising materials for storing and discharging latent heat in buildings to regulate the thermal environment. Measurement of salt hydrate PCM thermal performance is often challenging because of supercooling and phase segregation. Though differential scanning calorimetry (DSC) has been widely used to measure thermal properties of various phase change materials, DSC uses milligrams of sample and is unrealistic for predicting large-scale materials performance. The T-history method [1], in contrast, handles higher volumes but the analysis typically requires a lumped capacitance assumption. Here, we report and analyze T-History data on a novel salt-hydrogel complex with high viscosity, that renders low Biot number sample preparation extremely challenging. We re-examine the standard T-history method and compared against DSC data in this complex material. We report details of an experimental setup, built with necessary additions to a controlled environmental chamber. We carefully examine the validity of the lumped capacitance assumption and suggest a modified analysis using a computational approach for reliable data. Experimental parameters such as ramp rate and temperature range of the environmental chamber are considered via computational modeling to understand the effect of ramp rate on supercooling [2]. Finally, we report thermal cycling experiments on the salt-hydrogel complex. Our modified approach to measuring supercooling and enthalpy of fusion at large scales is important in better understanding the performance of phase-change materials at scale for building thermal storage. References: [1] Marin, Jose M, Belen Zalba, Luisa F Cabeza, and Harald Mehling. “Determination of Enthalpy Temperature Curves of Phase Change Materials with the Temperature-History Method: Improvement to Temperature Dependent Properties.” Measurement Science and Technology 14, no. 2 (February 1, 2003): 184–89. https://doi.org/10.1088/0957-0233/14/2/305. [2] Safari, A., R. Saidur, F.A. Sulaiman, Yan Xu, and Joe Dong. “A Review on Supercooling of Phase Change Materials in Thermal Energy Storage Systems.” Renewable and Sustainable Energy Reviews 70 (April 2017): 905–19. https://doi.org/10.1016/j.rser.2016.11.272
Constant-pH Molecular Dynamics Simulations for Large Biomolecular Systems
We report that an increasingly important endeavor is to develop computational strategies that enable molecular dynamics (MD) simulations of biomolecular systems with spontaneous changes in protonation states under conditions of constant pH. The present work describes our efforts to implement the powerful constant-pH MD simulation method, based on a hybrid nonequilibrium MD/Monte Carlo (neMD/MC) technique within the highly scalable program NAMD. The constant-pH hybrid neMD/MC method has several appealing features; it samples the correct semigrand canonical ensemble rigorously, the computational cost increases linearly with the number of titratable sites, and it is applicable to explicit solvent simulations. The present implementation of the constant-pH hybrid neMD/MC in NAMD is designed to handle a wide range of biomolecular systems with no constraints on the choice of force field. Furthermore, the sampling efficiency can be adaptively improved on-the-fly by adjusting algorithmic parameters during the simulation. Finally, illustrative examples emphasizing medium- and large-scale applications on next-generation supercomputing architectures are provided.
The Art of Automation: Translating Electron Microscopy Workflows Into Automated Processes
Acquiring data using a scanning transmission electron microscope (STEM) is a complex, multi-step process. The intricacy of the process depends on the type of sample, composition of the material, desired results of the experiment, resolution requirement and other experimental factors. Each experiment presents unique complications, such as sample drift and contamination, that the microscopist must consider when acquiring data. All these challenges are handled fluidly and expertly by experienced microscopists, but to reach new levels of innovation in material development, including greater reproducibility, throughput, and precision, the automation of these workflows is essential. The initial phase of this work involved translating intuition-based workflows into discrete, programmable steps. Some common key stages in STEM workflows are the initial tuning, scanning the sample for areas of interest, and then acquiring the data. Each stage can be broken further into specific parameter adjustments, such as aberration correction and dwell time optimization, depending on the experiment. When deconstructing various experiments each step was assessed for automation feasibility based on the amount of real time operator decisions. There are steps that lend themselves to automation more readily than others, such as course focusing and sample screening, but there is potential for full automation of all stages with time. As an initial step, an automated montage routine was developed, allowing for the efficient acquisition of large portions of the sample without requiring continuous intervention from the operator. The automation of this small process of the procedure demonstrates the value of this capability. A major challenge in automation arises from discrepancies between commanded, reported and actual stage movements. Using systematic tests, stage movement was quantified. This error can be corrected algorithmically for more accurate workflows in the future. Expanding automation capabilities would result in larger, more efficient data acquisition which allows for more robust statistical analysis. Additionally, this work lays the groundwork for a closed loop system where machine learning algorithms would intake automatically acquired data and make real time decisions. By progressively automating this instrument, this work establishes the foundation for fully automated experimentation in transmission electron microscopy.
Final Report: Sampling-Based Algorithms for Estimating Structure in Big Data.
The purpose of this project was to develop sampling-based algorithms to discover hidden struc- ture in massive data sets. Inferring structure in large data sets is an increasingly common task in many critical national security applications. These data sets come from myriad sources, such as network traffic, sensor data, and data generated by large-scale simulations. They are often so large that traditional data mining techniques are time consuming or even infeasible. To address this problem, we focus on a class of algorithms that do not compute an exact answer, but instead use sampling to compute an approximate answer using fewer resources. The particular class of algorithms that we focus on are streaming algorithms , so called because they are designed to handle high-throughput streams of data. Streaming algorithms have only a small amount of working storage - much less than the size of the full data stream - so they must necessarily use sampling to approximate the correct answer. We present two results: * A streaming algorithm called HyperHeadTail , that estimates the degree distribution of a graph (i.e., the distribution of the number of connections for each node in a network). The degree distribution is a fundamental graph property, but prior work on estimating the degree distribution in a streaming setting was impractical for many real-world application. We improve upon prior work by developing an algorithm that can handle streams with repeated edges, and graph structures that evolve over time. * An algorithm for the task of maintaining a weighted subsample of items in a stream, when the items must be sampled according to their weight, and the weights are dynamically changing. To our knowledge, this is the first such algorithm designed for dynamically evolving weights. We expect it may be useful as a building block for other streaming algorithms on dynamic data sets.
Stochastic projective splitting
Here, we present a new, stochastic variant of the projective splitting (PS) family of algorithms for inclusion problems involving the sum of any finite number of maximal monotone operators. This new variant uses a stochastic oracle to evaluate one of the operators, which is assumed to be Lipschitz continuous, and (deterministic) resolvents to process the remaining operators. Our proposal is the first version of PS with such stochastic capabilities. We envision the primary application being machine learning (ML) problems, with the method’s stochastic features facilitating “mini-batch” sampling of datasets. Since it uses a monotone operator formulation, the method can handle not only Lipschitz-smooth loss minimization, but also min–max and noncooperative game formulations, with better convergence properties than the gradient descent-ascent methods commonly applied in such settings. The proposed method can handle any number of constraints and nonsmooth regularizers via projection and proximal operators. We prove almost-sure convergence of the iterates to a solution and a convergence rate result for the expected residual, and close with numerical experiments on a distributionally robust sparse logistic regression problem.
GPU-advanced 3D electromagnetic simulations of superconductors in the Ginzburg–Landau formalism
Ginzburg–Landau theory is one of the most powerful phenomenological theories in physics, with particular predictive value in superconductivity. The formalism solves coupled nonlinear differential equations for both the electronic and magnetic responsiveness of a given superconductor to external electromagnetic excitations. With order parameter varying on the short scale of the coherence length, and the magnetic field being long-range, the numerical handling of 3D simulations becomes extremely challenging and time-consuming for realistic samples. Here we show precisely how one can employ graphics-processing units (GPUs) for this type of calculations, and obtain physics answers of interest in a reasonable time-frame – with speedup of over 100× compared to best available CPU implementations of the theory on a 256{sup 3} grid.