Suitability of markerless EPID tracking for tumor position verification in gated radiotherapy

Purpose: To maximize the benefits of respiratory gated radiotherapy (RGRT) of lung tumors real-time verification of the tumor position is required. This work investigates the feasibility of markerless tracking of lung tumors during beam-on time in electronic portal imaging device (EPID) images of the MV therapeutic beam. Methods: EPID movies were acquired at ∼2 fps for seven lung cancer patients with tumor peak-to-peak motion ranges between 7.8 and 17.9 mm (mean: 13.7 mm) undergoing stereotactic body radiotherapy. The external breathing motion of the abdomen was synchronously measured. Both datasets were retrospectively analyzed inPortalTrack, an in-house developed tracking software. The authors define a three-step procedure to run the simulations: (1) gating window definition, (2) gated-beam delivery simulation, and (3) tumor tracking. First, an amplitude threshold level was set on the external signal, defining the onset of beam-on/-off signals. This information was then mapped onto a sequence of EPID images to generate stamps of beam-on/-hold periods throughout the EPID movies in PortalTrack, by obscuring the frames corresponding to beam-off times. Last, tumor motion in the superior-inferior direction was determined on portal images by the tracking algorithm during beam-on time. The residual motion inside the gating window as well as target coverage (TC) and the marginal target displacement (MTD) were used as measures to quantify tumor position variability. Results: Tumor position monitoring and estimation from beam's-eye-view images during RGRT was possible in 67% of the analyzed beams. For a reference gating window of 5 mm, deviations ranging from 2% to 86% (35% on average) were recorded between the reference and measured residual motion. TC (range: 62%–93%; mean: 77%) losses were correlated with false positives incidence rates resulting mostly from intra-/inter-beam baseline drifts, as well as sudden cycle-to-cycle fluctuations in exhale positions. Both phenomena can lead to considerable deviations (with MTD values up to a maximum of 7.8 mm) from the intended tumor position, and in turn may result in a marginal miss. The difference between tumor traces determined within the gating window against ground truth trajectory maps was 1.1 ± 0.7 mm on average (range: 0.4–2.3 mm). Conclusions: In this retrospective analysis of motion data, it is demonstrated that the system is capable of determining tumor positions in the plane perpendicular to the beam direction without the aid of fiducial markers, and may hence be suitable as an online verification tool in RGRT. It may be possible to use the tracking information to enable on-the-fly corrections to intra-/inter-beam variations by adapting the gating window by means of a robotic couch.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-D-BRD-04: A Logical Organizational Approach to Clinical Information Management

Purpose: To develop a clinical information management system (CIMS) that collects, organizes physician inputs logically and supports analysis functionality. Methods: In a conventional electronic medical record system (EMR), the document manager component stores data in a pool of standalone .docx or .pdf files. The lack of a content-based logical organization makes cross-checking, reference or automatic inheritance of information challenging. We have developed an information-oriented clinical record system that addresses this shortcoming. In CIMS, a parent library predefines a set of available questions along with the data types of their expected answers. The creation of a questionnaire template is achieved by selecting questions from this parent library to form a virtual group. Instances of the same data field in different documents are linked by their question identifier. This design allows for flexible data sharing and inheritance among various forms using a longitudinal lineage of data indexed according to the modification time stamps of the documents. CIMS is designed with a web portal to facilitate querying, data entry and modification, aggregate report generation, and data adjudication. The current implementation addresses diagnostic data, medical history, vital signs, and various quantities in consult note and treatment summaries. Results: CIMS is currently storing treatment summary information of over 1,000 patients who have received treatment at UCLA Radiation Oncology between March 1, 2013 and January 31, 2014. We are in the process of incorporating a DICOM-RT dosimetry parser and patient reporting applications into CIMS, as well as continuing to define document templates to support additional forms. Conclusion: We are able to devise an alternative storage paradigm which results in an improvement in the accuracy and organizational structure of clinical information.

60 APPLIED LIFE SCIENCES↗

SU-E-J-170: Beyond Single-Cycle 4DCT: Maximum a Posteriori (MAP) Reconstruction-Based Binning-Free Multicycle 4DCT for Lung Radiotherapy

Purpose: Thoracic motion changes from cycle-to-cycle and day-to-day. Conventional 4DCT does not capture these cycle to cycle variations. We present initial results of a novel 4DCT reconstruction technique based on maximum a posteriori (MAP) reconstruction. The technique uses the same acquisition process (and therefore dose) as a conventional 4DCT in order to create a high spatiotemporal resolution cine CT that captures several breathing cycles. Methods: Raw 4DCT data were acquired from a lung cancer patient. The continuous 4DCT was reconstructed using MAP algorithm which uses the raw, time-stamped CT data to reconstruct images while simultaneously estimating deformation in the subject's anatomy. This framework incorporates physical effects such as hysteresis and is robust to detector noise and irregular breathing patterns. The 4D image is described in terms of a 3D reference image defined at one end of the hysteresis loop, and two deformation vector fields (DVFs) corresponding to inhale motion and exhale motion respectively. The MAP method uses all of the CT projection data and maximizes the log posterior in order to iteratively estimate a timevariant deformation vector field that describes the entire moving and deforming volume. Results: The MAP 4DCT yielded CT-quality images for multiple cycles corresponding to the entire duration of CT acquisition, unlike the conventional 4DCT, which only yielded a single cycle. Variations such as amplitude and frequency changes and baseline shifts were clearly captured by the MAP 4DC Conclusion: We have developed a novel, binning-free, parameterized 4DCT reconstruction technique that can capture cycle-to-cycle variations of respiratory motion. This technique provides an invaluable tool for respiratory motion management research. This work was supported by funding from the National Institutes of Health and VisionRT Ltd. Amit Sawant receives research funding from Varian Medical Systems, Vision RT and Elekta.

60 APPLIED LIFE SCIENCES↗

SU-E-T-473: A Patient-Specific QC Paradigm Based On Trajectory Log Files and DICOM Plan Files

Purpose: To evaluate a remote QC tool for monitoring treatment machine parameters and treatment workflow. Methods: The Varian TrueBeamTM linear accelerator is a digital machine that records machine axis parameters and MLC leaf positions as a function of delivered monitor unit or control point. This information is saved to a binary trajectory log file for every treatment or imaging field in the patient treatment session. A MATLAB analysis routine was developed to parse the trajectory log files for a given patient, compare the expected versus actual machine and MLC positions as well as perform a cross-comparison with the DICOM-RT plan file exported from the treatment planning system. The parsing routine sorts the trajectory log files based on the time and date stamp and generates a sequential report file listing treatment parameters and provides a match relative to the DICOM-RT plan file. Results: The trajectory log parsing-routine was compared against a standard record and verify listing for patients undergoing initial IMRT dosimetry verification and weekly and final chart QC. The complete treatment course was independently verified for 10 patients of varying treatment site and a total of 1267 treatment fields were evaluated including pre-treatment imaging fields where applicable. In the context of IMRT plan verification, eight prostate SBRT plans with 4-arcs per plan were evaluated based on expected versus actual machine axis parameters. The average value for the maximum RMS MLC error was 0.067±0.001mm and 0.066±0.002mm for leaf bank A and B respectively. Conclusion: A real-time QC analysis program was tested using trajectory log files and DICOM-RT plan files. The parsing routine is efficient and able to evaluate all relevant machine axis parameters during a patient treatment course including MLC leaf positions and table positions at time of image acquisition and during treatment.

60 APPLIED LIFE SCIENCES↗

MO-F-CAMPUS-T-05: SQL Database Queries to Determine Treatment Planning Resource Usage

Purpose: A radiation oncology clinic’s treatment capacity is traditionally thought to be limited by the number of machines in the clinic. As the number of fractions per course decrease and the number of adaptive plans increase, the question of how many treatment plans a clinic can plan becomes increasingly important. This work seeks to lay the ground work for assessing treatment planning resource usage. Methods: Care path templates were created using the Aria 11 care path interface. Care path tasks included key steps in the treatment planning process from the completion of CT simulation through the first radiation treatment. SQL Server Management Studio was used to run SQL queries to extract task completion time stamps along with care path template information and diagnosis codes from the Aria database. 6 months of planning cycles were evaluated. Elapsed time was evaluated in terms of work hours within Monday – Friday, 7am to 5pm. Results: For the 195 validated treatment planning cycles, the average time for planning and MD review was 22.8 hours. Of those cases 33 were categorized as urgent. The average planning time for urgent plans was 5 hours. A strong correlation between diagnosis code and range of elapsed planning time was as well as between elapsed time and select diagnosis codes was observed. It was also observed that tasks were more likely to be completed on the date due than the time that they were due. Follow-up confirmed that most users did not look at the due time. Conclusion: Evaluation of elapsed planning time and other tasks suggest that care paths should be adjusted to allow for different contouring and planning times for certain diagnosis codes and urgent cases. Additional clinic training around task due times vs dates or a structuring of care paths around due dates is also needed.

60 APPLIED LIFE SCIENCES↗

WE-AB-BRB-12: Nanoscintillator Fiber-Optic Detector System for Microbeam Radiation Therapy Dosimetry

Purpose: Microbeam Radiation Therapy (MRT) is an experimental radiation therapy that has demonstrated a higher therapeutic ratio than conventional radiation therapy in animal studies. There are several roadblocks in translating the promising treatment technology to clinical application, one of which is the lack of a real-time, high-resolution dosimeter. Current clinical radiation detectors have poor spatial resolution and, as such, are unsuitable for measuring microbeams with submillimeter-scale widths. Although GafChromic film has high spatial resolution, it lacks the real-time dosimetry capability necessary for MRT preclinical research and potential clinical use. In this work we have demonstrated the feasibility of using a nanoscintillator fiber-optic detector (nanoFOD) system for real-time MRT dosimetry. Methods: A microplanar beam array is generated using a x-ray research irradiator and a custom-made, microbeam-forming collimator. The newest generation nanoFOD has an effective size of 70 µm in the measurement direction and was calibrated against a kV ion chamber (RadCal Accu-Pro) in open field geometry. We have written a computer script that performs automatic data collection with immediate background subtraction. A computer-controlled detector positioning stage is used to precisely measure the microbeam peak dose and beam profile by translating the stage during data collection. We test the new generation nanoFOD system, with increased active scintillation volume, against the previous generation system. Both raw and processed data are time-stamped and recorded to enable future post-processing. Results: The real-time microbeam dosimetry system worked as expected. The new generation dosimeter has approximately double the active volume compared to the previous generation resulting in over 900% increase in signal. The active volume of the dosimeter still provided the spatial resolution that meets the Nyquist criterion for our microbeam widths. Conclusion: We have demonstrated that real-time dosimetry of MRT microbeams is feasible using a nanoscintillator fiber-optic detector with integrated positioning system.

60 APPLIED LIFE SCIENCES↗

WE-G-BRA-06: Application of Systems and Control Theory-Based Hazard Analysis to Radiotherapy

Purpose: The process of delivering radiation occurs in a complex socio-technical system heavily reliant on human operators. Furthermore, both humans and software are notoriously challenging to account for in traditional hazard analysis models. High reliability industries such as aviation have approached this problem through using hazard analysis techniques grounded in systems and control theory. The purpose of this work is to apply the Systems Theoretic Accident Model Processes (STAMP) hazard model to radiotherapy. In particular, the System-Theoretic Process Analysis (STPA) approach is used to perform a hazard analysis of a proposed on-line adaptive cranial radiosurgery procedure that omits the CT Simulation step and uses only CBCT for planning, localization, and treatment. Methods: The STPA procedure first requires the definition of high-level accidents and hazards leading to those accidents. From there, hierarchical control structures were created followed by the identification and description of control actions for each control structure. Utilizing these control structures, unsafe states of each control action were created. Scenarios contributing to unsafe control action states were then identified and translated into system requirements to constrain process behavior within safe boundaries. Results: Ten control structures were created for this new CBCT-only process which covered the areas of hospital and department management, treatment design and delivery, and vendor service. Twenty three control actions were identified that contributed to over 80 unsafe states of those control actions resulting in over 220 failure scenarios. Conclusion: The interaction of people, hardware, and software are highlighted through the STPA approach. STPA provides a hierarchical model for understanding the role of management decisions in impacting system safety so that a process design requirement can be traced back to the hazard and accident that it is intended to mitigate. Varian Medical Systems, Inc.

60 APPLIED LIFE SCIENCES↗

SU-F-T-11: Scintillator Based Quality Assurance Device for HDR Brachytherapy

Purpose: To build a test device for HDR afterloaders capable of checking source positions, times at positions and estimate the activity of the source. Methods: A catheter is taped on a plastic scintillation sheet. When a source travels through the catheter, the scintillator sheet lights up around the source. The sheet is monitored with a video camera, and records the movement of the light spot. The center of the spot on each image on the video provides the source location, and the time stamps of the images can provide the dwell time the source spend in each location. Finally, the brightness of the light spot is related to the activity of the source. A code was developed for noise removal, calibrate the scale of the image to centimeters, eliminate the distortion caused by the oblique view angle, identifying the boundaries of the light spot, transforming the image into binary and detect and calculate the source motion, positions and times. The images are much less noisy if the camera is shielded. That requires that the light spot is monitored in a mirror, rather than directly. The whole assembly is covered from external light and has a size of approximately 17×35×25cm (H×L×W) Results: A cheap camera in BW mode proved to be sufficient with a plastic scintillator sheet. The best images were resulted by a 3mm thick sheet with ZnS:Ag surface coating. The shielding of the camera decreased the noise, but could not eliminate it. A test run even in noisy condition resulted in approximately 1 mm and 1 sec difference from the planned positions and dwell times. Activity tests are in progress. Conclusion: The proposed method is feasible. It might simplify the monthly QA process of HDR Brachytherapy units.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-T-99: Data Visualization From a Treatment Planning Tracking System for Radiation Oncology

Purpose: A treatment planning process tracker database with input forms and a TV-viewable display webpage was developed and implemented in our clinic to collect time data points throughout the process. Tracking plan times is important because it directly affects the patient quality of care. Simply, the longer a patient waits after their initial simulation CT for treatment to begin, the more time the cancer has to progress. The tracker helps to drive workflow through the clinic, while the data collected can be used to understand and manage the process to find and eliminate inefficiencies. Methods: The overall process steps tracked are CT-simulation, mark patient, draw normal contours, draw target volumes, create plan, and review/approve plan. Time stamps for task completion were extracted and used to generate a set of clinic metrics, among which include average time for each step in the process split apart by type of treatment, average time to completion for plans started in a given week, and individual overall completion time per plan. Results: Trends have been tracked for fourteen weeks of clinical data (196 plans). On average, drawing normal contours and target volumes is taking 2–5 times as long as creating the plan itself. This is potentially an issue because it could mean the process is taking too long initially, and it could be forcing the planning step to be done in a short amount of time. We also saw from our graphs that there appears to be no clear trend on the average amount of time per plan week-to-week. Conclusion: A tracker of this type has the potential to provide insight into how time is utilized in our clinic. By equipping our dosimetrists, radiation oncologists, and physicists with individualized metric sets, the tracker can help provide visibility and drive workflow. Funded in part by CPRIT (RP140105).

60 APPLIED LIFE SCIENCES↗

SU-F-T-101: Insight into Dosimetry Workload and Planning Timelines: A 6 Year Review at One Institution

Purpose: To elucidate realistic clinical treatment planning workload and timelines to improve understanding for patients, payers, and other institutions involved in radiotherapy processes. Methods: A web based tool was developed using Oracle Express (Oracle Corp, Redwood City, CA) which allowed communication between the physicians and staff about the current state of the patient plan. For 6 years, all patient courses were logged and time-stamped in 22 discreet steps which detailed start and stop times for simulation, contouring, and treatment planning tasks. This data was combined with the treatment planning database (TPDB) using the Eclipse Scripting API (Varian Medical Systems, Palo Alto, CA) to cross-identify plans between the two systems. This time data was analyzed across our dosimetry staff and treatment modality. Results: In 6 years, 110,477 patient statuses were time-logged for 9683 courses of treatment using our internal software. The courses contained 8305 unique patients who were binned into one of 11 diagnosis site categories. 8253 courses could be reconciled against the TPDB using timestamp data from patient statuses. The average planning volume per dosimetrist was 375.8 ± 142.4 plans per year with the average number of planning revisions per dosimetrist of 71.0 ± 27.1 plans per year. The median treatment planning times by modality ranged from to 48.3 hours for IMRT plans 5 fields or less to 119.6 hours for IMRT with 8 or more fields. Two arc VMAT, three arc VMAT, and 3D plans median times were 89.1 hours, 113.8 hours, and 50.9 hours respectively. Conclusion: Using our web based tool, we have demonstrated the ability to quantify treatment planning timelines and workloads which could help in setting appropriate expectations for patients, payers, and hospital administration. COI: Author received monies from Varian Medical Systems for research and teaching honorarium.

60 APPLIED LIFE SCIENCES↗

Time-of-flight measurements of heavy ions using Si PIN diodes

A new off-line timing method for PIN diode signals is presented which allows the plasma delay effect to be suppressed. Velocities of heavy ions measured by the new method are in good agreement within a wide range of masses and energies with velocities measured by time stamp detectors based on microchannel plates.

74 ATOMIC AND MOLECULAR PHYSICS↗

An Efficient Format for Nearly Constant-Time Access to Arbitrary Time Intervals in Large Trace Files

A powerful method to aid in understanding the performance of parallel applications uses log or trace files containing time-stamped events and states (pairs of events). These trace files can be very large, often hundreds or even thousands of megabytes. Because of the cost of accessing and displaying such files, other methods are often used that reduce the size of the tracefiles at the cost of sacrificing detail or other information. This paper describes a hierarchical trace file format that provides for display of an arbitrary time window in a time independent of the total size of the file and roughly proportional to the number of events within the time window. This format eliminates the need to sacrifice data to achieve a smaller trace file size (since storage is inexpensive, it is necessary only to make efficient use of bandwidth to that storage). The format can be used to organize a trace file or to create a separate file of annotations that may be used with conventional trace files. We present an analysis of the time to access all of the events relevant to an interval of time and we describe experiments demonstrating the performance of this file format.

Chan, Anthony↗

DAQMAN - A flexible configurable data acquisition system

DAQMAN is a flexible configurable interface that allows the user to build and operate a VME-based data acquisition system on a Linux workstation. It consists of two parts: a Java-based Graphical User Interface to configure the system, and a C-based utility that reads out the data and creates the output ASCII data file, with two levels of diagnostic tools. The data acquisition system requires a CAEN CONET-VME Bridge to communicate between the hardware in the VME crate and the Linux workstation. Data acquisition modules, such as ADCs, TDC, Scalers, can be loaded into the system, or removed easily. The GUI allows users to activate modules, and channels within modules by clicking on icons. Running configurations are stored; data are collected and can be viewed either as raw numbers, or by charts and histograms that update as the data are accumulated. Data files are written to disk in ASCII format, with a date and time stamp.

Sivertz, Michael↗

solar-data-tools

Tools for performing common tasks on solar PV data signals. These tasks include finding clear days in a data set, common data transforms, and fixing time stamp issues. These tools are designed to be automatic and require little if any input from the user. Libraries are included to help with data IO and plotting as well.

Meyers, Bennet↗

EQ_phase_detection

The EQ_phase_detection software is designed to scan continuous daily waveforms to detect earthquake phase arrivals from local to regional (150 km) events. The detections are made with a deep learning encoder-decoder model. When the model detects an earthquake in the waveforms, a second model is implemented to classify the first arriving motions. Both deep learning models are trained with the Tensorflow package using publicly available benchmark data sets. The software input is a path to a directory that contains waveforms in mseed format and the associated response files in xml format. The output is a data table of time stamped detections, signal amplitude, signal-to-noise ratio, and softmax probability of the detection in a generic format applicable to post-processing association algorithms for event locations. Additionally, the p-wave and s-wave waveforms are saved in a data table for rapid access when producing improved locations using correlation-based techniques. The software is designed for multiprocessing with multiple GPU’s for rapid processing of large data sets. The configuration file provides flexibility in the trained models implemented and allows access to multiple models trained for different sampling rates or input dimensions. This is particularly useful for regions with multiple networks that do not have the same data parameters.

Johnson, Christopher↗

TListSpectrum

TListSpectrum is a C++ class developed inside the CERN high-energy physics analysis C++ framework ROOT. This class structure was developed to assist in the processing, visualization, and analysis of list-mode or time-stamped radiation spectroscopy data. The class structure currently contains parsing and functionality to synthesize list-mode data from CAEN and Mirion Lynx radiation spectroscopy digital acquisition systems along with feature functionality to post-process data sets and build coincident data sets from the instrument.

Pierson, Bruce↗

SPADES (Scalable Parallel Discrete Events Simulation) [SWR-24-99]

SPADES (Solver for PArallel Discrete Event Simulation) is an open-source parallel discrete event simulation (PDES) package built on the AMReX library. Targeted at solving discrete event systems in parallel, this software package aims to be performance portable and scalable on heterogeneous computing architectures, e.g., graphic processing units (GPU). SPADES implements optimistic synchronization with rollback through an implementation of the Time Warp algorithm. An alternative conservative synchronization approach is also implemented using the Lower Bound on Incoming Time Stamp. In our implementation, logical processes are represented as cells in a grid and event messages are represented as particles. SPADES supports various parallel decomposition strategies, including the use of the Message Passing Interface (MPI) and OpenMP threading. All major GPU architectures (e.g., Intel, AMD, NVIDIA) are supported through the use of performance portability functionalities implemented in AMReX. The SPADES software is released in NREL Software Record SWR-24-99 “SPADES (Scalable Parallel Discrete Events Simulation)”.

Henry de Frahan, Marc [National Renewable Energy L↗

ESTPiper – a web-based analysis pipeline for expressed sequence tags

Background: EST sequencing projects are increasing in scale and scope as the genome sequencing technologies migrate from core sequencing centers to individual research laboratories. Effectively, generating EST data is no longer a bottleneck for investigators. However, processing large amounts of EST data remains a non-trivial challenge for many. Web-based EST analysis tools are proving to be the most convenient option for biologists when performing their analysis, so these tools must continuously improve on their utility to keep in step with the growing needs of research communities. We have developed a web-based EST analysis pipeline called ESTPiper, which streamlines typical large-scale EST analysis components. Results: The intuitive web interface guides users through each step of base calling, data cleaning, assembly, genome alignment, annotation, analysis of gene ontology (GO), and microarray oligonucleotide probe design. Each step is modularized. Therefore, a user can execute them separately or together in batch mode. In addition, the user has control over the parameters used by the underlying programs. Extensive documentation of ESTPiper's functionality is embedded throughout the web site to facilitate understanding of the required input and interpretation of the computational results. The user can also download intermediate results and port files to separate programs for further analysis. In addition, our server provides a time-stamped description of the run history for reproducibility. The pipeline can also be installed locally, allowing researchers to modify ESTPiper to suit their own needs. Conclusion: ESTPiper streamlines the typical process of EST analysis. The pipeline was initially designed in part to support the Daphnia pulex cDNA sequencing project. A web server hosting ESTPiper is provided at http://estpiper.cgb.indiana.edu/ to now support projects of all size. The software is also freely available from the authors for local installations.