Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SLICING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

SU-E-J-240: Development of a Novel 4D MRI Sequence for Real-Time Liver Tumor Tracking During Radiotherapy

Purpose: To develop a Novel 4D MRI Technique that is feasible for realtime liver tumor tracking during radiotherapy. Methods: A volunteer underwent an abdominal 2D fast EPI coronal scan on a 3.0T MRI scanner (Siemens Inc., Germany). An optimal set of parameters was determined based on image quality and scan time. A total of 23 slices were scanned to cover the whole liver in the test scan. For each scan position, the 2D images were retrospectively sorted into multiple phases based on breathing signal extracted from the images. Consequently the 2D slices with same phase numbers were stacked to form one 3D image. Multiple phases of 3D images formed the 4D MRI sequence representing one breathing cycle. Results: The optimal set of scan parameters were: TR= 57ms, TE= 19ms, FOV read= 320mm and flip angle= 30°, which resulted in a total scan time of 14s for 200 frames (FMs) per slice and image resolution of (2.5mm,2.5mm,5.0mm) in three directions. Ten phases of 3D images were generated, each of which had 23 slices. Based on our test scan, only 100FMs were necessary for the phase sorting process which may lower the scan time to 7s/100FMs/slice. For example, only 5 slices/35s are necessary for a 4D MRI scan to cover liver tumor size ≤ 2cm leading to the possibility of tumor trajectory tracking every 35s during treatment. Conclusion: The novel 4D MRI technique we developed can reconstruct a 4D liver MRI sequence representing one breathing cycle (7s/ slice) without an external monitor. This technique can potentially be used for real-time liver tumor tracking during radiotherapy.

60 APPLIED LIFE SCIENCES↗

SU-E-T-669: Radiosurgery Failure for Trigeminal Neuralgia: A Study of Radiographic Spatial Fidelity

Purpose: Management of Trigeminal Neuralgia with radiosurgery is well established, but often met with limited success. Recent advancements in imaging afford improvements in target localization for radiosurgery. Methods: A Trigeminal Neuralgia radiosurgery specific protocol was established for MR enhancement of the trigeminal nerve using a CISS scan with slice spacing of 0.7mm. Computed Tomography simulation was performed using axial slices on a 40 slice CT with slice spacing of 0.6mm. These datasets were registered using a mutual information algorithm and localized in a stereotactic coordinate system. Image registration between the MR and CT was evaluated for each patient by a Medical Physicist to ensure accuracy. The dorsal root entry zone target was defined on the CISS MR by a Neurosurgeon and dose calculations performed on the localized CT. Treatment plans were reviewed and approved by a Radiation Oncologist and Neurosurgeon. Image guided radiosurgery was delivered using positioning tolerance of 0.5mm and 1°. Eight patients with Trigeminal Neuralgia were treated with this protocol. Results: Seven patients reported a favorable response to treatment with average Barrow Neurological Index pain score of four before treatment and one following treatment. Only one patient had a BNI>1 following treatment and review of the treatment plan revealed that the CISS MR was registered to the CT via a low resolution (5mm slice spacing) T2 MR. All other patients had CISS MR registered directly with the localized CT. This patient was retreated 6 months later using direct registration between CISS MR and localized CT and subsequently responded to treatment with a BNI of one. Conclusion: Frameless radiosurgery offers an effective solution to Trigeminal Neuralgia management provided appropriate technology and imaging protocols (utilizing submillimeter imaging) are established and maintained.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Super-resolution reconstruction in frequency, image, and wavelet domains to reduce through-plane partial voluming in MRI

Purpose: To compare and evaluate the use of super-resolution reconstruction (SRR), in frequency, image, and wavelet domains, to reduce through-plane partial voluming effects in magnetic resonance imaging. Methods: The reconstruction of an isotropic high-resolution image from multiple thick-slice scans has been investigated through techniques in frequency, image, and wavelet domains. Experiments were carried out with thick-slice T2-weighted fast spin echo sequence on the Academic College of Radiology MRI phantom, where the reconstructed images were compared to a reference high-resolution scan using peak signal-to-noise ratio (PSNR), structural similarity image metric (SSIM), mutual information (MI), and the mean absolute error (MAE) of image intensity profiles. The application of super-resolution reconstruction was then examined in retrospective processing of clinical neuroimages of ten pediatric patients with tuberous sclerosis complex (TSC) to reduce through-plane partial voluming for improved 3D delineation and visualization of thin radial bands of white matter abnormalities. Results: Quantitative evaluation results show improvements in all evaluation metrics through super-resolution reconstruction in the frequency, image, and wavelet domains, with the highest values obtained from SRR in the image domain. The metric values for image-domain SRR versus the original axial, coronal, and sagittal images were PSNR = 32.26 vs 32.22, 32.16, 30.65; SSIM = 0.931 vs 0.922, 0.924, 0.918; MI = 0.871 vs 0.842, 0.844, 0.831; and MAE = 5.38 vs 7.34, 7.06, 6.19. All similarity metrics showed high correlations with expert ranking of image resolution with MI showing the highest correlation at 0.943. Qualitative assessment of the neuroimages of ten TSC patients through in-plane and out-of-plane visualization of structures showed the extent of partial voluming effect in a real clinical scenario and its reduction using SRR. Blinded expert evaluation of image resolution in resampled out-of-plane views consistently showed the superiority of SRR compared to original axial and coronal image acquisitions. Conclusions: Thick-slice 2D T2-weighted MRI scans are part of many routine clinical protocols due to their high signal-to-noise ratio, but are often severely affected by through-plane partial voluming effects. This study shows that while radiologic assessment is performed in 2D on thick-slice scans, super-resolution MRI reconstruction techniques can be used to fuse those scans to generate a high-resolution image with reduced partial voluming for improved postacquisition processing. Qualitative and quantitative evaluation showed the efficacy of all SRR techniques with the best results obtained from SRR in the image domain. The limitations of SRR techniques are uncertainties in modeling the slice profile, density compensation, quantization in resampling, and uncompensated motion between scans.

60 APPLIED LIFE SCIENCES↗

Technical Note: Method to correlate whole-specimen histopathology of radical prostatectomy with diagnostic MR imaging

Purpose: Validation of MRI-guided tumor boundary delineation for targeted prostate cancer therapy is achieved via correlation with gold-standard histopathology of radical prostatectomy specimens. Challenges to accurate correlation include matching the pathology sectioning plane with the in vivo imaging slice plane and correction for the deformation that occurs between in vivo imaging and histology. A methodology is presented for matching of the histological sectioning angle and position to the in vivo imaging slices. Methods: Patients (n = 4) with biochemical failure following external beam radiotherapy underwent diagnostic MRI to confirm localized recurrence of prostate cancer, followed by salvage radical prostatectomy. High-resolution 3-D MRI of the ex vivo specimens was acquired to determine the pathology sectioning angle that best matched the in vivo imaging slice plane, using matching anatomical features and implanted fiducials. A novel sectioning device was developed to guide sectioning at the correct angle, and to assist the insertion of reference dye marks to aid in histopathology reconstruction. Results: The percentage difference in the positioning of the urethra in the ex vivo pathology sections compared to the positioning in in vivo images was reduced from 34% to 7% through slicing at the best match angle. Reference dye marks were generated, which were visible in ex vivo imaging, in the tissue sections before and after processing, and in histology sections. Conclusions: The method achieved an almost fivefold reduction in the slice-matching error and is readily implementable in combination with standard MRI technology. The technique will be employed to generate datasets for correlation of whole-specimen prostate histopathology with in vivo diagnostic MRI using 3-D deformable registration, allowing assessment of the sensitivity and specificity of MRI parameters for prostate cancer. Although developed specifically for prostate, the method is readily adaptable to other types of whole tissue specimen, such as mastectomy or liver resection.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-C-206-03: Metal Artifact Reduction in X-Ray Computed Tomography Based On Local Anatomical Similarity

Purpose: Metal implants such as orthopedic hardware and dental fillings cause severe bright and dark streaking in reconstructed CT images. These artifacts decrease image contrast and degrade HU accuracy, leading to inaccuracies in target delineation and dose calculation. Additionally, such artifacts negatively impact patient set-up in image guided radiation therapy (IGRT). In this work, we propose a novel method for metal artifact reduction which utilizes the anatomical similarity between neighboring CT slices. Methods: Neighboring CT slices show similar anatomy. Based on this anatomical similarity, the proposed method replaces corrupted CT pixels with pixels from adjacent, artifact-free slices. A gamma map, which is the weighted summation of relative HU error and distance error, is calculated for each pixel in the artifact-corrupted CT image. The minimum value in each pixel’s gamma map is used to identify a pixel from the adjacent CT slice to replace the corresponding artifact-corrupted pixel. This replacement only occurs if the minimum value in a particular pixel’s gamma map is larger than a threshold. The proposed method was evaluated with clinical images. Results: Highly attenuating dental fillings and hip implants cause severe streaking artifacts on CT images. The proposed method eliminates the dark and bright streaking and improves the implant delineation and visibility. In particular, the image non-uniformity in the central region of interest was reduced from 1.88 and 1.01 to 0.28 and 0.35, respectively. Further, the mean CT HU error was reduced from 328 HU and 460 HU to 60 HU and 36 HU, respectively. Conclusions: The proposed metal artifact reduction method replaces corrupted image pixels with pixels from neighboring slices that are free of metal artifacts. This method proved capable of suppressing streaking artifacts, improving HU accuracy and image detectability.

60 APPLIED LIFE SCIENCES↗

SU-F-J-102: Lower Esophagus Margin Implications Based On Rapid Computational Algorithm for SBRT

Purpose: To quantify inter-fraction esophagus-variation. Methods: Computed tomography and daily on-treatment 0.3-T MRI data sets for 7 patients were analyzed using a novel Matlab-based (Mathworks, Natick, MA) rapid computational method. Rigid registration was performed from the cricoid to the gastro-esophageal junction. CT and MR-based contours were compared at slice intervals of 3mm. Variation was quantified by “expansion,” defined as additional length in any radial direction from CT contour to MR contour. Expansion computations were performed with 360° of freedom in each axial slice. We partitioned expansions into left anterior, right anterior, right posterior, and left posterior quadrants (LA, RA, RP, and LP, respectively). Sample means were compared by analysis of variance (ANOVA) and Fisher’s Protected Least Significant Difference test. Results: Fifteen fractions and 1121 axial slices from 7 patients undergoing SBRT for primary lung cancer (3) and metastatic lung disease (4) were analyzed, generating 41,970 measurements. Mean LA, RA, RP, and LP expansions were 4.30±0.05 mm, 3.71±0.05mm, 3.17±0.07, and 3.98±0.06mm, respectively. 50.13% of all axial slices showed variation > 5 mm in one or more directions. Variation was greatest in lower esophagus with mean LA, RA, RP, and LP expansion (5.98±0.09 mm, 4.59±0.09 mm, 4.04±0.16 mm, and 5.41±0.16 mm, respectively). The difference was significant compared to mid and upper esophagus (p<.0001). The 95th percentiles of expansion for LA, RA, RP, LP were 13.36 mm, 9.97 mm, 11.29 mm, and 12.19 mm, respectively. Conclusion: Analysis of on-treatment MR imaging of the lower esophagus during thoracic SBRT suggests margin expansions of 13.36 mm LA, 9.97 mm RA, 11.29 mm RP, 12.19 mm LP would account for 95% of measurements. Our novel algorithm for rapid assessment of margin expansion for critical structures with 360° of freedom in each axial slice enables continuously adaptive patient-specific margins which may reduce overlap with high-dose regions.

60 APPLIED LIFE SCIENCES↗

Utilizing remote sensing data for land use decisions for Indian lands in South Dakota.

Evaluation of photographic and thermal infrared imagery acquired at an altitude of 11,500 ft above ground level (in southwestern South Dakota) on Oct. 15, 1970, June 30, 1971, and Aug. 2, 1971, for use in mapping range sites and soils. A density slicing system was used to enhance film optical density differences associated with range sites and soils. The range site boundaries in native rangeland areas were found to be delineated best by a density slicing analysis of color infrared film obtained in August 1971. The range site maps produced by density slicing were superior to existing range inventory maps. The density slicing analysis of color infrared film from the August 1971 flight was best for locating soil boundaries in rangeland areas. To adequately map soils in rangeland areas, data based on density slicing used in conjunction with slope gradient information derived from stereoscopic analyses provided more detailed and accurate information than is presently available from range site and soil maps of the area.

Frazee, C. J.↗

TEXCAD: Textile Composite Analysis for Design. Version 1.0: User's manual

The Textile Composite Analysis for Design (TEXCAD) code provides the materials/design engineer with a user-friendly desktop computer (IBM PC compatible or Apple Macintosh) tool for the analysis of a wide variety of fabric reinforced woven and braided composites. It can be used to calculate overall thermal and mechanical properties along with engineering estimates of damage progression and strength. TEXCAD also calculates laminate properties for stacked, oriented fabric constructions. It discretely models the yarn centerline paths within the textile repeating unit cell (RUC) by assuming sinusoidal undulations at yarn cross-over points and uses a yarn discretization scheme (which subdivides each yarn not smaller, piecewise straight yarn slices) together with a 3-D stress averaging procedure to compute overall stiffness properties. In the calculations for strength, it uses a curved beam-on-elastic foundation model for yarn undulating regions together with an incremental approach in which stiffness properties for the failed yarn slices are reduced based on the predicted yarn slice failure mode. Nonlinear shear effects and nonlinear geometric effects can be simulated. Input to TEXCAD consists of: (1) materials parameters like impregnated yarn and resin properties such moduli, Poisson's ratios, coefficients of thermal expansion, nonlinear parameters, axial failure strains and in-plane failure stresses; and (2) fabric parameters like yarn sizes, braid angle, yarn packing density, filament diameter and overall fiber volume fraction. Output consists of overall thermoelastic constants, yarn slice strains/stresses, yarn slice failure history, in-plane stress-strain response and ultimate failure strength. Strength can be computed under the combined action of thermal and mechanical loading (tension, compression and shear).

Naik, Rajiv A.↗

TEXCAD: TEXile Composite Analysis for Design

The Textile Composite Analysis for Design (TEXCAD) code provides the materials/design engineer with a user-friendly, desktop computer based tool for the analysis of a wide variety of fabric reinforced woven and braided composites. It can be used to calculate overall thermal and mechanical properties along with engineering estimates of damage progression and strength. TEXCAD also calculates laminate properties for stacked, oriented fabric constructions. It discretely models the yarn centerline paths within the textile repeating unit cell (RUC) by assuming sinusoidal undulations at yarn cross-over points and uses a year discretization scheme (which subdivides each yarn into smaller, piecewise straight yarn slices) together with a 3-D stress averaging procedure to compute overall stiffness properties. In the calculations for strength, it uses a curved beam-on-elastic foundation model for yarn undulating regions together with incremental approach in which stiffness properties for the failed yarn slices are reduced based on the predicted yarn slice failure mode. Nonlinear shear effects and nonlinear geometric effects can be stimulated. Input to TEXCAD consists of: (1) material parameters like impregnated yarn and resin properties such as moduli, Poisson's ratios, coefficients of thermal expansion, nonlinear shear parameters, axial failure strains, and in-plane failure stresses; and (2) fabric parameters like yarn sizes, braid angle, yarn packing density, filament diameter, and overall fiber volume fraction. Output consists of overall thermoelastic constants, yarn slice strains/stresses, yarn slice failure history, in-plane strain response, and ultimate failure strength. Strength can be computed under the combined action of thermal and mechanical loading (tension, compression, and shear). A brief overview of the analytical capabilities, program organization, and modules, input and output parameters, computer platforms, distribution, and modifications/extensions of the TEXCAD code are presented here.

Naik, Rajiv A.↗

N-methyl-D-aspartate increases acetylcholine release from rat striatum and cortex: its effect is augmented by choline

We examined the effects of N-methyl-D-aspartate (NMDA), a glutamate agonist, and of glutamate itself, on acetylcholine (ACh) release from superfused rat striatal slices. In a Mg(++)-free medium, NMDA (32-1000 microM) as well as glutamate (1 mM) increased basal ACh release by 35 to 100% (all indicated differences, P less than .05), without altering tissue ACh or choline contents. This augmentation was blocked by Mg++ (1.2 mM) or by MK-801 (10 microM). Electrical stimulation (15 Hz, 75 mA) increased ACh release 9-fold (from 400 to 3660 pmol/mg of protein): this was enhanced (to 4850 pmol/mg of protein) by NMDA (100 microM). ACh levels in stimulated slices fell by 50 or 65% depending on the absence or presence of NMDA. The addition of choline (40 microM) increased ACh release both basally (570 pmol/mg of protein) and with electrical stimulation (6900 pmol/mg of protein). In stimulated slices choline acted synergistically with NMDA, raising ACh release to 10,520 pmol/mg of protein. The presence of choline also blocked the fall in tissue ACh. No treatment affected tissue phospholipid or protein levels. NMDA (32-320 microM) also augmented basal ACh release from cortical but not hippocampal slices. Choline efflux from striatal and cortical (but not hippocampal) slices decreased by 34 to 50% in Mg(++)-free medium. These data indicate that NMDA-like drugs may be useful, particularly in combination with choline, to enhance striatal and cortical cholinergic activity. ACh release from rat hippocampus apparently is not affected by NMDA receptors.

Non-NASA Center↗

Investigation of Vapor Cooling Enhancements for Applications on Large Cryogenic Systems

The need to demonstrate and evaluate the effectiveness of heat interception methods for use on a relevant cryogenic propulsion stage at a system level has been identified. Evolvable Cryogenics (eCryo) Structural Heat Intercept, Insulation and Vibration Evaluation Rig (SHIIVER) will be designed with vehicle specific geometries (SLS Exploration Upper Stage (EUS) as guidance) and will be subjected to simulated space environments. One method of reducing structure-born heat leak being investigated utilizes vapor-based heat interception. Vapor-based heat interception could potentially reduce heat leak into liquid hydrogen propulsion tanks, increasing potential mission length or payload capability. Due to the high number of unknowns associated with the heat transfer mechanism and integration of vapor-based heat interception on a realistic large-scale skirt design, a sub-scale investigation was developed. The sub-project effort is known as the Small-scale Laboratory Investigation of Cooling Enhancements (SLICE). The SLICE aims to study, design, and test sub-scale multiple attachments and flow configuration concepts for vapor-based heat interception of structural skirts. SLICE will focus on understanding the efficiency of the heat transfer mechanism to the boil-off hydrogen vapor by varying the fluid network designs and configurations. Various analyses were completed in MATLAB, Excel VBA, and COMSOL Multiphysics to understand the optimum flow pattern for heat transfer and fluid dynamics. Results from these analyses were used to design and fabricate test article subsections of a large forward skirt with vapor cooling applied. The SLICE testing is currently being performed to collect thermal mechanical performance data on multiple skirt heat removal designs while varying inlet vapor conditions necessary to intercept a specified amount of heat for a given system. Initial results suggest that applying vapor-cooling provides a 50 heat reduction in conductive heat transmission along the skirt to the tank. The information obtained by SLICE will be used by the SHIIVER engineering team to design and implement vapor-based heat removal technology into the SHIIVER forward skirt hardware design.

small scale testing↗

Concurrent Runtime Verification of Data Rich Events

This paper presents the open source runtime verification tool MESA (MEssage-based System Analysis), implemented in Scala, which supports concurrent monitors using the Actor model. Furthermore, the tool supports indexing (slicing) on the data values occurring in data-carrying events, for each individual monitor. The tool is generic in the sense that any monitoring system can be used for creating monitors. In this paper, we use the internal Scala DSL Daut for programming such in data parameterized state machines and temporal logic. To illustrate MESA/Daut, we present a case study that monitors flights from live U.S. airspace data streams, verifying that they conform to planned routes. With base in the case study, we then perform an extensive empirical study of the potential benefits from monitoring slices of a single property in concurrently executing actors. Due to the overhead of scheduling “small” actors (one for each slice or a small number of slices), it is not obvious that concurrent execution of such is beneficial. However, as a main result, we demonstrate that concurrent monitoring of slices to handle data-carrying events can provide considerable speed gains.

finite state machines↗

Micrometer to Atomic Scale Characterisation of Primitive Astromaterials Using A Novel Method, Metis-Fa: A Coordinated Atom Probe Tomography, Transmission Electron Microscopy and NanoSIMS Approach

Introduction: Presolar grains preserve isotopic, chemical and microstructural records of physical and chemical processing, and formation mechanisms within a vast range of evolved stellar systems, the interstellar medium, solar nebula and their parent bodies. These evolutionary records are preserved at the micrometric to atomic scale, requiring coordinated studies to expand our understanding of evolutionary processes occurringthroughout ours and external stellar systems [1]. NanoSIMS enabled rapid in situ identification and isotopic characterisation of presolar grains and their stellar origins using 17O/16O and 18O/16O, and 13C/12C isotopic ratios [1]. Coordination with transmission electron microscopy (TEM) revealed crystallographic and localised contextual relationships and quantitively constrained their major and minor compositions [1]. However, trace elements cannot be quantified, the most sensitive geochemical tracers of environmental conditions, essential to unravelling the chemical record of their evolutionary pathway and parent stellar systems [2-3] . Furthermore, owing to the combination of technical limitations (only 5 – 7 isotopes can be measured per NanoSIMS run) and their small grain sizes of 100 nm < 3 μm (with rare exceptions in nanodiamonds (2 nm ≤) and SiC (< 40 μm)), the number of measurable isotopes per grain volume is limited [1,3] . Through more comprehensive isotopic studies of presolar grains, NanoSIMS studies have shown the importance of the latter, identifying Fe and Mg as important indicators of nuclear synthetic processing and their stellar origins, respectively [4- 5]. Coordination of NanoSIMS and Atom Probe Tomography (APT) revealed morphological signatures, and isotopic and chemical signatures at major to trace levels without requirements for preselection of elements [6]. However, crystallographic signatures in localized contextual relationships cannot be measured. Consequently, coordination of NanoSIMS, TEM and APT is essential to gain access to almost all contextual, structural and geochemical signatures within each presolar grain.Transmission electron microscopy requires a 100 nm thin lamella which is unstable in APT and would not produce any viable data. Atom probe tomography requires a needle-shaped specimen which when measured in TEM removes the local context, impacts the quality of the TEM diffraction images due to the shank angle of the needle, and can alter the chemistry of beam sensitive materials from the higher degree of surface exposure at the tip. To address these issues, we developed METIS-Fa (Multi-technical measurements of Electron Transparent materials using an Indium Sandwich - a FIB approach). A novel method which enables coordination of NanoSIMS, TEM and APT for generalized and targeted studies of individual grains, including beam sensitive materials, without compromising sample preparation requirements for TEM and APT. This method requires only indium and a Focus Ion Beam (FIB), minimizing the movement of fragile materials while still enabling preparation of TEM lamella into APT needles. Samples: Initial experimental development and testing of the method occurred at Astromaterials Research and Exploration Science (ARES), Johnson Space Centre (JSC), NASA and APT measurements and needle preparation occurred at JdLC, Curtin University. Synthetic silicate samples were used as analogs for presolar silicates when performing a trial run of the method. Samples were extracted from a polished thin section created at JSC, NASA, comprised of 38 wt.% Si, 17 wt.% FeO, 13 wt.% MgO, 12 wt.% Al, 11 wt.% Ca based on electron microprobe analysis (EMPA) [8] . Experimental details, pressure and temperature conditions were presented in [8] and references therein. Testing of the capability to target individual grains in mineral matrices using this method for acquisition in APT, measured matrix regions in meteoritic thin sections of primitive meteorites. These meteorites and their identified presolar grains for future targeted studies are detailed in [9]. Techniques: The TEM-FIB lamella were prepared using a FIB. An e-beam assisted pt deposition was used as a protective coating for the synthetic and meteoritic samples. When targeting individual grains, a secondary e-beam assisted pt deposition button is placed over the desired grain before the protective coating to denote its location. A JEOL 2500SE field-emission TEM was used for high-resolution imaging, energy-dispersive X-ray (EDX) and electron diffraction data.TheMETIS-Fa method was experimentally designed, tested and executed using a FIB at ARES, JSCNASA. Needles for APT were prepared using the Tescan Lyra3 GM Dual Beam Focus Ion Beam (FIB) Field Emission SEM (FE-SEM) at the JdLC, Curtin University. Atom probe tomography measurements were conducted using a CAMECA Local Electrode Atom Probe, LEAP 4000X HR. Two pure indium needles were analyzed initially to constraining acquisition parameters and stability under the beam. Manual acquisition was required to maintain evaporation of specimen’s at the apex and monitor interactions with measurement parameters. Experimental Design: Indium foil is pressed onto an Al stub with a pneumatic press and mounted into the FIB adjacent to the TEM-FIB lamella of interest. Using a FIB, two indium slices (5 μm x ~300 nm x 3 μm) are extracted from indium foil and aligned with the TEM-FIB lamella before touching the TEM-FIB lamella. Each slice is then attached through cold welding to the FIB-TEM lamella. This approach eliminates the need for chemical treatments and proved effective for aligning the Indium within the region of interest for APT, holding it in place for up to 4 days during testing.Once both indium slices are attached within their pre-determined region per grain targeting requirements, they are gradually melted onto the FIB-TEM lamella.When targeting a specific grain, measurements should be taken of the pt button and its distance from edge to edge of the lamella before and after sandwiching. A secondary button should be placed over the same region after the Indium slices have been attached to improve precision when preparing APT needles. Results: Figure 1 shows two indium slices melted onto a FIB-TEM lamella, adding additional bulk for preparation into APT needles as shown in Figure 2 [7] . The latter was essential so samples could be measured in TEM and APT without compromising sample preparation requirements and consequently data quality and acquisition stability. METIS-Fa proved effective forimproving geometry. Figure 3 shows a successful APTrun of the synthetic silicate. EMPA, TEM and APTshowed no chemical alterations. During targetingtesting, a solar silicate grain was successfully identifiedand measured in TEM, and prepared into an APTneedle. However, the indium was melted too long during sample preparation, causing expansion andformation of internal porosity leading to sample loss.Conclusion: METIS-Fa greatly expands the number of isotopic and chemical signatures measured per grain volume, and enables measurements of contextual, structural, crystallographic, isotopic and geochemical signatures within individual grains. Gaining access to such a vast range of evolutionary signatures required for expanding our understanding of external stellar and planetary systems and the evolution of our solar system. This method was designed for application to a vast range of phases including being sensitive materials and thus provides a way for coordination of NanoSIMS, TEM and APT not just for the study of presolar grains and by extension primitive astromaterials, but studies in a vast range of other fields including the geosciences and material sciences.Acknowledgments: Thankyou to ARES, JSC, NASA; JdLC Curtin University and Space Science Technology Centre for the use of laboratory facilities and funding [confirm].

Nicole D Nevill↗

A novel approach for adaptive skeleton toolpath generation

Industry 4.0 is revolutionizing manufacturing through the integration of automation and real-time data sharing in cyber-physical systems. At the forefront of this revolution is large-format additive manufacturing. In large-format printing, parts are often designed to be an even number of beads wide to produce a completely dense part. However, voids can still arise. This is often due to the part not being an even number of bead widths wide in some areas, or in geometry containing acute angles, as the process of generating closed contours cannot completely fill the space. Voids can be tolerated in smaller models, but in large-format additive manufacturing they may cause mechanical defects. To fill these voids, open loop paths called skeletons are often used, but they are typically limited by the physical constraints defined in the slicing software. To address this, researchers at Oak Ridge National Laboratory have extended skeleton toolpaths via an adaptive methodology. These adaptive skeletons were found to better fill void spaces through manipulation of physical parameters of the build process and were calculated as part of the slicing process.

42 ENGINEERING↗

Schrödinger evolution of two-dimensional black holes

This paper systematically treats the evolving quantum state for two-dimensional black holes, with particular focus on the CGHS model, but also elucidating features generalizing to higher dimensions. This is done in Schrödinger picture(s), to exhibit the dynamic evolution of the state at intermediate times. After a review of classical solutions, also connecting to descriptions of higher-dimensional black holes, it overviews the canonical quantum treatment of the full evolution, including gravitational dynamics. Derived in an approximation to this, following conversion to “perturbation picture”, is the evolution of the quantum matter on the background geometry. Features of the evolving matter state are described, based on choice of a time slicing to put the evolution into ADM form. The choices of slicing as well as coordinates on the slices result in different quantum “pictures” for treating the evolution. If such a description is based on smooth trans-horizon slices, that avoids explicit reference to ultra-planckian modes familiar from traditional treatments, and exhibits the Hawking excitations as emerging from a “quantum atmosphere” with thickness comparable to the inverse temperature. Detailed study of the state exhibits the entanglement structure between Hawking quanta and the partner excitations inside the black hole, and the corresponding “missing information”. This explicit description also allows direct study of the evolution and features, e.g. as seen by infalling observers, of these partner excitations, helping to address various puzzles with them. Explicit treatment of the evolving state, and its extension to higher dimensions, provides further connections to information theory and a starting point for study of corrections that can unitarize evolution, arising from new quantum gravity effects — whether wormholes or something entirely different.

2D Gravity↗

The g-code file

The slicing process for additive manufacturing (AM) involves many steps, including slicing the object to be printed and fitting toolpaths to each resulting layer. The toolpaths define the trajectories that the machine must follow during printing to construct the object. Once the slicing is complete and all toolpaths have been found and properly planned, this data must be transferred to the 3D printer in a way the printer can use to construct the object. This is achieved by exporting a file, usually a g-code file, from the slicing software. The g-code file is a text-based file that contains instructions for the machine, controlling the system and defining the motions for each toolpath. The file, which often contains thousands of lines of code, is mostly composed of numbers that command positions for axis motions. This chapter will outline the contents of a g-code file, discuss various commands and their implementation, then provide example codes and files for object construction.

Roschli, Alex↗

Comparison of automated chemical-guided segmentation and human annotation of soil organic matter in X-ray microcomputed tomography imaging in contrasted soil types

Soil organic matter (OM) formation and persistence is strongly influenced by the spatial distribution of organic substrates and microscale soil heterogeneity by dictating OM accessibility to microorganisms. However, traditional size and/or density fractionation techniques disrupt aggregate architecture, eliminating spatial information needed to fully understand intra-aggregate OM distribution. To quantify three-dimensional OM spatial distribution and automate segmentation in X-ray microcomputed tomography (µCT) imaging without human annotation bias, we developed an iodine gas vapor (I2) based staining workflow that eliminates labor-intensive manual annotation while maintaining segmentation accuracy, using aggregates from four taxonomically diverse soils (Xerofluvent, Haploxeroll Sphagnofibrist, Palehumult) with an 8-fold range of soil organic carbon. Human annotation of 10 µCT slices by the experienced and inexperienced annotators resulted in variations up to 3% in the Dice similarity coefficient (DSC), reflecting a degree of inherent subjectivity of manual labeling. Such inconsistencies are expected to compound as the number of manually annotated slices increases. Dual-energy µCT imaging at 33.1 keV (below the iodine (I) K-edge) and 33.2 keV (above the I K-edge) was used to resolve aggregate microstructure following I2 staining. The automated image subtraction pipeline identified OM regions by the I Kedge induced brightness increases, achieving DSC values of 0.58–0.83 relative to an experienced annotator. Sensitivity analyses revealed that the reconstruction alpha value—optimized via the open-source tool TomocuPy—and the 3D registration slice count were the primary determinants of accuracy, providing a novel benchmark for dual-energy soil imaging. The pipeline without GPU acceleration achieved 9.6 to 43.2 times faster than manual annotation. Using GPU-accelerated image post-processing and affine transformation matrices, the pipeline successfully segmented OM elements for large-scale datasets (3232×3232 pixel, 2048 slices) within ~5200 s from raw file acquisition to segmented output. The high-throughput approach enables the quantification of OM spatial distribution across diverse and heterogeneous soil.

Soil microbial biomass↗

MRI-Based Computed Tomography Metal Artifact Correction Method for Improving Proton Range Calculation Accuracy

Purpose: Computed tomography (CT) artifacts can severely degrade dose calculation accuracy in proton therapy. Prompted by the recently increased popularity of magnetic resonance imaging (MRI) in the radiation therapy clinic, we developed an MRI-based CT artifact correction method for improving the accuracy of proton range calculations. Methods and Materials: The proposed method replaces corrupted CT data by mapping CT Hounsfield units (HU number) from a nearby artifact-free slice, using a coregistered MRI. MRI and CT volumetric images were registered with use of 3-dimensional (3D) deformable image registration (DIR). The registration was fine-tuned on a slice-by-slice basis by using 2D DIR. Based on the intensity of paired MRI pixel values and HU from an artifact-free slice, we performed a comprehensive analysis to predict the correct HU for the corrupted region. For a proof-of-concept validation, metal artifacts were simulated on a reference data set. Proton range was calculated using reference, artifactual, and corrected images to quantify the reduction in proton range error. The correction method was applied to 4 unique clinical cases. Results: The correction method resulted in substantial artifact reduction, both quantitatively and qualitatively. On respective simulated brain and head and neck CT images, the mean error was reduced from 495 and 370 HU to 108 and 92 HU after correction. Correspondingly, the absolute mean proton range errors of 2.4 cm and 1.7 cm were reduced to less than 2 mm in both cases. Conclusions: Our MRI-based CT artifact correction method can improve CT image quality and proton range calculation accuracy for patients with severe CT artifacts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗