Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAMPLE POSITIONING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Comparison of ACHILLES and GENIE Observables for DUNE-PRISM and the SBN Program, with New 2p2h Predictions

The DUNE near detector LAr-TPC can be moved to different off-axis positions to sample different neutrino fluxes, which in turn will yield different cross section distributions for observables. Several DUNE ND off axis locations were simulated using GENIE and ACHILLES, and generator differences and FSI contributions were examined for various observables. Additionally, the predictions were compared with those of existing experiments, and it is shown that the DUNE ND 20m off axis predictions are similar to that of MicroBooNE for various observables. Finally, the 2p2h interaction mode was simulated for ACHILLES for the first time for ICARUS, and a preliminary comparison is made to MicroBooNE data and simulations from different event generators.

Dumont, Daniel [Fermilab]↗

Verifying Mars 2020 Sampling and Caching Robotic Functions with Position Budgeting Process and Tool

The Mars 2020 Perseverance Rover was launched on July 30th, 2020 with one of the most complex robotic systems ever implemented on an interplanetary mission. Much of this robotic complexity resides in the Rover Sampling and Caching Subsystem (SCS) to enable collection of Martian samples for eventual return to earth and preparation of surfaces for close-up surface science observations. Two robotic arms are used by SCS: the large Robotic Arm (RA) positions the coring drill and science instruments mounted to the Turret for surface interactions, and the smaller Sample Handling Assembly (SHA) manipulates Sample Tube Assemblies (STA) within the Adaptive Caching Assembly (ACA) to prepare them for sample collection, processing, and hermetic sealing. The robotic arms interact with the Martian surface and other SCS components in many ways and in a variety of configurations, with positioning accuracy requirements ranging from tens of millimeters for some surface interactions down to sub-millimeter accuracy for some ACA interactions.This paper describes the process and tool used to calculate the SCS robotic interaction positioning budgets and verify the as-built hardware when delivered. To ensure that these robotic systems are able to perform their tasks, each robotic interaction with another element was broken down into its composite functions. To calculate a positioning budget margin for each function, an allowable was defined and then compared to the list of error sources that contribute to misalignment. Across the subsystem, over 250 functions were identified to be assessed, with almost 500 error sources feeding into their budget calculations. In addition to using as-built values in the budgets for SCS Verification and Validation (V&V) after the hardware was complete, these budgets were populated with design data during the design phase to identify areas of concern and guide hardware design to ensure positive position budget margins.Because of the size of the SCS team that had inputs to the positioning budgets and the sheer number of items in the budgets that needed to be created, updated, and verified, having a tool that would allow for simultaneous access and robust data integrity and processing was imperative. To accomplish this, a web-based MySQL database was created that allowed users to create function position budgets, link individual errors and allowables to them, and view function position budget margin reports. Each error and allowable records data for lateral, normal, angular, and clocking errors, with the ability to add as-built data for up to four different hardware builds. Margin reports can be generated for either design values alone or replacing design data with as-built data when available. These as-built reports are used for final verification of the SCS positioning requirements. Ultimately, the SCS positioning budget process and database tool led to successful interactions during test and an SCS robotic system that is ready to perform sample acquisition and caching on the surface of Mars.

Williams, Jeffrey↗

Detection of Apparent Early Rabies Infection by LN34 Pan-Lyssavirus Real-Time RT-PCR Assay in Pennsylvania

The Pennsylvania Department of Health Bureau of Laboratories (PABOL) tested 6855 animal samples for rabies using both the direct fluorescent antibody test (DFA) and LN34 pan-lyssavirus reverse transcriptase quantitative PCR (RT-qPCR) during 2017–2019. Only two samples (0.03%) were initially DFA negative but positive by LN34 RT-qPCR. Both cases were confirmed positive upon re-testing at PABOL and confirmatory testing at the Centers for Disease Control and Prevention by LN34 RT-qPCR and DFA. Rabies virus sequences from one sample were distinct from all positive samples processed at PABOL within two weeks, ruling out cross-contamination. Levels of rabies virus antigen and RNA were low in all brain structures tested, but were higher in brain stem and rostral spinal cord than in cerebellum, hippocampus or cortex. Taken together, the low level of rabies virus combined with higher abundance in more caudal brain structures suggest early infection. These cases highlight the increased sensitivity and ease of interpretation of LN34 RT-qPCR for low positive cases.

59 BASIC BIOLOGICAL SCIENCES↗

Combined Falling Drop/Open Port Sampling Interface System for Automated Flow Injection Mass Spectrometry

The aim of this work was to demonstrate and to evaluate the analytical performance of a combined falling drop/open port sampling interface (OPSI) system as a simple noncontact, no-carryover, automated system for flow injection analysis with mass spectrometry. The falling sample drops were introduced into the OPSI using a widely available autosampler platform utilizing low cost disposable pipet tips and conventional disposable microtiter well plates. The volume of the drops that fell onto the OPSI was in the 7–15 μL range with an injected sample volume of several hundred nanoliters. Sample drop height, positioning of the internal capillary on the sampling end of the probe, and carrier solvent flow rate were optimized for maximum signal. Sample throughput, signal reproducibility, matrix effects, and quantitative analysis capability of the system were established using the drug molecule propranolol and its isotope labeled internal standard in water, unprocessed river water and two commercially available buffer matrices. A sample-to-sample throughput of ~45 s with a ~4.5 s base-to-base flow injection peak profile was obtained in these experiments. In addition, quantitation with minimally processed rat plasma samples was demonstrated with three different statin drugs (atorvastatin, rosuvastatin, and fluvastatin). Direct characterization capability of unprocessed samples was demonstrated by the analysis of neat vegetable oils. Employing the autosampler system for spatially resolved liquid extraction surface sampling exemplified by the analysis of propranolol and its hydroxypropranolol glucuronide phase II metabolites from a rat thin tissue section was also illustrated.

47 OTHER INSTRUMENTATION↗

An instrument for in situ coherent x-ray studies of metal-organic vapor phase epitaxy of III-nitrides

Here, we describe an instrument that exploits the ongoing revolution in synchrotron sources, optics, and detectors to enable in situ studies of metal-organic vapor phase epitaxy (MOVPE) growth of III-nitride materials using coherent x-ray methods. The system includes high-resolution positioning of the sample and detector including full rotations, an x-ray transparent chamber wall for incident and diffracted beam access over a wide angular range, and minimal thermal sample motion, giving the sub-micron positional stability and reproducibility needed for coherent x-ray studies. The instrument enables surface x-ray photon correlation spectroscopy, microbeam diffraction, and coherent diffraction imaging of atomic-scale surface and film structure and dynamics during growth, to provide fundamental understanding of MOVPE processes.

36 MATERIALS SCIENCE↗

A new, simple electrostatic-acoustic hybrid levitator

Battelle has developed a hybrid levitator by combining the known single-axis acoustic standing wave levitator with a coaxial DC electric field. The resulting Coulomb forces on the charged liquid or solid sample support its weight and, together with the acoustic force, center the sample. Liquid samples with volumes approximately less than 100 micro-liters are deployed from a syringe reservoir into the acoustic pressure node. The sample is charged using a miniature high voltage power supply (approximately less than 20 kV) connected to the syringe needle. As the electric field, generated by a second miniature power supply, is increased, the acoustic intensity is reduced. The combination of both fields allows stable levitation of samples larger than either single technique could position on the ground. Decreasing the acoustic intensity reduces acoustic convection and sample deformation. Neither the electrostatic nor the acoustic field requires sample position sensing or active control. The levitator, now used for static and dynamic fluid physics investigations on the ground, can be easily modified for space operations.

Lierke, E. G.↗

M558 radioactive tracer diffusion

This experiment was performed in Skylab 3 with two objectives in mind. First, the experimental self-diffusion coefficients for liquid zinc were to be determined in a convection-free environment. Secondly the reduction in convective mixing in earth gravity by going into the zero-gravity environment of space was to be estimated. The experiment was designed to utilize high temperatures and linear thermal gradients provided by the M518 Multipurpose Electric Furnace, and the radioactivity of zinc-65 of 245-day half-life to investigate self-diffusion in liquid zinc. The distribution of zinc-65 tracer, after melting, maintaining at soak temperature for 1 hour of soak time and then resolidifying, was obtained by sample sectioning. The concentration of activity of each section (microcurie-gram) was plotted against positions along the sample axial and radial position. Experimental data and theoretical results from solution of Fick's law of diffusion in one dimensional were compared. Samples tested on earth showed very rapid diffusion. Diffusion coefficient in unit gravity was 50 times the zero-gravity diffusion coefficient of Skylab.

Ukanwa, A. O.↗

Insights from a workplace SARS-CoV-2 specimen collection program, with genomes placed into global sequence phylogeny

In 2020, the Department of Energy established the National Virtual Biotechnology Laboratory (NVBL) to address key challenges associated with COVID-19. As part of that effort, Pacific Northwest National Laboratory (PNNL) established a capability to collect and analyze specimens from employees who self-reported symptoms consistent with the disease. During the spring and fall of 2021, 688 specimens were screened for SARS-CoV-2, with 64 (9.3%) testing positive using reverse-transcriptase quantitative PCR (RT-qPCR). Of these, 36 samples were released for research. All 36 positive samples released for research were sequenced and genotyped. Here, the relationship between patient age and viral load as measured by Ct values was measured and determined to be only weakly significant. Consensus sequences for each sample were placed into a global phylogeny and transmission dynamics were investigated, revealing that the closest relative for many samples was from outside of Washington state, indicating mixing of viral pools within geographic regions.

59 BASIC BIOLOGICAL SCIENCES↗

Method for high-throughput micro-sampling analysis of electrochemical process salts

A method and apparatus for analyzing molten salt electrolyte. The method includes extracting a sample of a molten salt electrolyte from an electrorefiner or other process vessel or conduit; generating droplets from the sample, where the droplets are at a first temperature; transporting the droplets to detectors, where during transport, the droplets attain a second temperature that is lower than the first temperature; analyzing the droplets at or below the second temperature; and returning the droplets to the process. The apparatus includes a droplet generator; a sample transport mechanism; and at least one detector positioned above the sample transport mechanism.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Data for Post-Access Report: Tidal Energy Resource Characterization and Model Validation via the Assessment of Cost-effective Spatially Distributed Current Measurements from microFloat Swarms

This project evaluated how high-resolution, spatially distributed field data can be used to refine and validate site-scale hydrodynamic simulations of tidal channels. Use of such spatially-distributed field observations or site-scale hydrodynamic simulations will be needed for producing accurate predictions of tidal energy production over larger arrays of tidal turbines. The data contained in this archive includes field observations of water velocity from a series of short surveys in Agate Pass taken on August 20th, 2020 using station-keeping ADCP (acoustic doppler current profiler) measurements, drifting downward-looking ADCPs, and microFloats, gathered by researchers at APL-UW under a previous project. It also includes high-resolution hydrodynamic model runs for the site during that time generated under TEAMER support. An explanatory file (.pdf format) describes the survey and field data structure. Processed data is stored in .mat format. Survey summary: start time, number of floats, water level. microFloat data: - Cleaned data for each float in survey, - Time series of position (lat., lon.), depth (relative to surface), and horizontal velocity (u, v) Drifting ADCP data: - Cleaned data for each drifting ADCP in survey - Time series of position (lat., lon.), sample depth (relative to surface), and observed water velocity (u,v,w) Stationary ADCP data: - Cleaned data for each station-keeping data set in survey - Time series of position (lat., lon.), sample depth (relative to surface), and observed water velocity (u,v,w) FVCOM (Finite Volume Coastal Ocean Model) model outputs: Water level and velocity, as well as derived variables (e.g., power density) from the final refined model simulations for the Agate Pass subdomain. Contained in NetCDF and ASCII files for the duration of August 18th and 20th 2020 field surveys. Additional scripts for processing the data and generating the figures in the report are included.

16 TIDAL AND WAVE POWER↗

Magnetic hysterysis evolution of Ni-Al alloy with Fe and Mn substitution by vacuum arc melting to produce the room temperature magnetocaloric effect material

The development of magnetocaloric effect (MCE) material is done in order to reduce the damage of the ozone layer caused by the chlorofluorocarbons (CFCs) emitted into the air. The research dealing with synthesis of magnetocaloric materials based of Ni-Al Heusler Alloy structure and by varying substitution some atoms of Ni with Fe and Al with Mn on Ni-Al Heusler Alloy structure to become Ni{sub 44}Fe{sub 6}Mn{sub 32}Al{sub 18}. Vacuum Arc Melting (VAM) equipment is used to form the alloys on vacuum condition and by flowing argon gas atmosphere and then followed by annealing process for 72 hours. X-Ray Diffraction (XRD) reveals that crystallite structure of material is observed. We define that Ni{sub 44}Fe{sub 6} as X{sub 2}, Mn{sub 25} as Y, and Al{sub 18}Mn{sub 7} as Z. Based on the XRD result, we observed that the general formula X{sub 2}YZ is not changed. The PERMAGRAF measurement revealed that there exists of magnetic hysterysis. The hysterysis show that the magnetic structures of the system undego evolution from diamagnetic to soft ferromagnetic material which all of the compound have the same crystallite structure. This evolution indicated that the change in the composition has led to changes the magnetic composition. Mn is the major element that gives strong magnetic properties to the sample. When Mn partially replaced position of Al, the sample became dominant to be influenced to improve their magnetic properties. In addition, substitution a part of Ni by Fe in the composition reveals a pinning of the domain walls in the sample.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Velocity reconstruction in the era of DESI and Rubin/LSST. I. Exploring spectroscopic, photometric, and hybrid samples

Peculiar velocities of galaxies and halos can be reconstructed from their spatial distribution alone. This technique is analogous to the baryon acoustic oscillations reconstruction, using the continuity equation to connect density and velocity fields. The resulting reconstructed velocities can be used to measure imprints of galaxy velocities on the cosmic microwave background like the kinematic Sunyaev-Zel’dovich effect or the moving lens effect. As the precision of these measurements increases, characterizing the performance of the velocity reconstruction becomes crucial to allow unbiased and statistically optimal inference. In this paper, we quantify the relevant performance metrics: the variance of the reconstructed velocities and their correlation coefficient with the true velocities. We show that the relevant velocities to reconstruct for kSZ and moving lens are actually the halo—rather than galaxy—velocities. We quantify the impact of redshift-space distortions, photometric redshift errors, satellite galaxy fraction, incorrect cosmological parameter assumptions and smoothing scale on the reconstruction performance. Here, we also investigate hybrid reconstruction methods, where velocities inferred from spectroscopic samples are evaluated at the positions of denser photometric samples. We find that using exclusively the photometric sample is better than performing a hybrid analysis. The 2 Gpc/ℎ length simulations from abacussummit with realistic galaxy samples for DESI and Rubin LSST allow us to perform this analysis in a controlled setting. In the companion paper [B. Hadzhiyska, S. Ferraro, B. Ried Guachalla, and E. Schaan, companion paper, Phys. Rev. D 109, 103534 (2024).], we further include the effects of evolution along the light cone and give realistic performance estimates for DESI luminous red galaxies, emission line galaxies, and Rubin LSST-like samples.

79 ASTRONOMY AND ASTROPHYSICS↗

Non-destructive, in-situ evaluation of water presence using thermal contrast and cooled detector

Exemplary systems for detecting water include: a light source positioned to transmit thermal radiation through a sample; a lens assembly positioned to: receive the thermal radiation transmitted through the sample; and focus the transmitted thermal radiation onto a filter positioned between the lens assembly and a detector; and a cooling subsystem for cooling the filter and the detector to a temperature below that of the sample. The filter (1) selectively transmits first portions of the thermal radiation received from the lens assembly and characterized by a wavelength at least partially overlapping a predefined water absorption band and/or a predefined water absorption line; and (2) selectively blocks second portions of the thermal radiation received from the lens assembly and characterized by a wavelength outside the predefined water absorption band and/or the predefined water absorption line. Methods for detecting presence of water in a sample are also disclosed.

Bora, Mihail↗

Non-destructive, in-situ evaluation of water presence using thermal contrast and cooled detector

Exemplary systems for detecting water include: a light source positioned to transmit thermal radiation through a sample; a lens assembly positioned to: receive the thermal radiation transmitted through the sample; and focus the transmitted thermal radiation onto a filter positioned between the lens assembly and a detector; and a cooling subsystem for cooling the filter and the detector to a temperature below that of the sample. Methods for detecting presence of water in a sample are also disclosed.

47 OTHER INSTRUMENTATION↗

Stepwise crystallization and the layered distribution in crystallization kinetics of ultra-thin poly(ethylene terephthalate) film

Crystallization is an important property of polymeric materials. In conventional viewpoint, the transformation of disordered chains into crystals is usually a spatially homogeneous process (i.e., it occurs simultaneously throughout the sample), that is, the crystallization rate at each local position within the sample is almost the same. Here, we show that crystallization of ultra-thin poly(ethylene terephthalate) (PET) films can occur in the heterogeneous way, exhibiting a stepwise crystallization process. We found that the layered distribution of glass transition dynamics of thin film modifies the corresponding crystallization behavior, giving rise to the layered distribution of the crystallization kinetics of PET films, with an 11-nm-thick surface layer having faster crystallization rate and the underlying layer showing bulk-like behavior. The layered distribution in crystallization kinetics results in a particular stepwise crystallization behavior during heating the sample, with the two cold-crystallization temperatures separated by up to 20 K. Meanwhile, interfacial interaction is crucial for the occurrence of the heterogeneous crystallization, as the thin film crystallizes simultaneously if the interfacial interaction is relatively strong. We anticipate that this mechanism of stepwise crystallization of thin polymeric films will allow new insight into the chain organization in confined environments and permit independent manipulation of localized properties of nanomaterials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

From local to global measurements of nonclassical nonlinear elastic effects in geomaterials

Here, the equivalence between local and global measures of nonclassical nonlinear elasticity is established in a slender resonant bar. Nonlinear effects are first measured globally using nonlinear resonance ultrasound spectroscopy (NRUS), which monitors the relative shift of the resonance frequency as a function of the maximum dynamic strain in the sample. Subsequently, nonlinear effects are measured locally at various positions along the sample using dynamic acousto elasticity testing (DAET). Finally, after correcting analytically the DAET data for three-dimensional strain effects and integrating numerically these corrected data along the length of the sample, the NRUS global measures are retrieved almost exactly.

36 MATERIALS SCIENCE↗

Computer-Controlled, Motorized Positioning System

Computer-controlled, motorized positioning system developed for use in robotic manipulation of samples in custom-built secondary-ion mass spectrometry (SIMS) system. Positions sample repeatably and accurately, even during analysis in three linear orthogonal coordinates and one angular coordinate under manual local control, or microprocessor-based local control or remote control by computer via general-purpose interface bus (GPIB).

Vargas-Aburto, Carlos↗

Nanocalorimeter platform for in situ specific heat measurements and x-ray diffraction at low temperature

Recent advances in electronics and nanofabrication have enabled membrane-based nanocalorimetry for measurements of the specific heat of microgram-sized samples. We have integrated a nanocalorimeter platform into a 4.5 T split-pair vertical-field magnet to allow for the simultaneous measurement of the specific heat and x-ray scattering in magnetic fields and at temperatures as low as 4 K. This multi-modal approach empowers researchers to directly correlate scattering experiments with insights from thermodynamic properties including structural, electronic, orbital, and magnetic phase transitions. The use of a nanocalorimeter sample platform enables numerous technical advantages: precise measurement and control of the sample temperature, quantification of beam heating effects, fast and precise positioning of the sample in the x-ray beam, and fast acquisition of x-ray scans over a wide temperature range without the need for time-consuming re-centering and re-alignment. Furthermore, on an YBa 2 Cu 3 O 7-δ crystal and a copper foil, we demonstrate a novel approach to x-ray absorption spectroscopy by monitoring the change in sample temperature as a function of incident photon energy. Lastly, we illustrate the new insights that can be gained from in situ structural and thermodynamic measurements by investigating the superheated state occurring at the first-order magneto-elastic phase transition of Fe 2 P, a material that is of interest for magnetocaloric applications.

47 OTHER INSTRUMENTATION↗