Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Regulating Electronic Structure of Single-Atom Catalysts toward Efficient Bifunctional Oxygen Electrocatalysis

We report electronic structure of single-atom catalysts (SACs) is critical for bifunctional oxygen electrocatalysis by adjusting the binding energy in oxygen-containing intermediates. However, the regulation of electronic structure has always been a challenge to improve catalytic reactivity. Herein, by introducing a heterogenous metal, the electronic structure through a direct bonding interaction to the active center atom is effectively adjusted. Partial charge transfer between the two atoms optimizes the binding energy of intermediates and reducing the energy barrier of the catalytic reaction. Theoretical calculations confirm these effects and the uniform distribution of 3d orbitals, leading to the improvement of bifunctional oxygen electrocatalytic reactivity. Benefiting from these attributes, the as-constructed bifunctional catalyst enables outstanding electrocatalytic performances in both oxygen reduction and hydrogen oxidation in various energy storage systems. The generality and expandability of this strategy is demonstrated by further successful development of other dual-metal catalysts systems with various active metals.

36 MATERIALS SCIENCE↗

Factors Influencing Propensity for Stress Relaxation Cracking in Inconel® Alloy 740H® and Practical Guidance for Applications

Inconel® alloy 740H® (UNS N07740) was the first age-hardenable nickel-based alloy approved by the ASME Boiler & Pressure Vessel Code for use in pressure-boundary applications. In recent years, advanced energy systems such as supercritical CO2 power cycles have utilized alloy 740H in large demonstration projects driven by the requirement for higher fluid temperatures and pressures. Stress relaxation cracking (SRxC) following post-weld heat-treatment (PWHT), also known as strain age cracking (SAC), has been identified in a limited number of weldments during these industrial builds resulting in focused research to further clarify factors influencing this cracking tendency. This paper will summarize some of the findings from shop and field fabrication leading to successful welds and characteristics of observed SRxC. Laboratory experiments supported by microstructural characterization will be presented to highlight the importance of variables such as strain, material starting condition, and PWHT temperatures. Finally, the results will be summarized within the context of practical guidance for industry to successfully weld the material in boiler, heat exchanger, and piping applications.

14 SOLAR ENERGY↗

Customized Tapered Stent-Grafts in the Endovascular Management of Internal Iliac Artery Aneurysms: A Useful Adjunct to Conventional Endovascular Options

The endovascular exclusion of an isolated iliac artery aneurysm is recognized as a safe and favorable alternative to open surgical repair, with low associated morbidity and mortality. It has particular advantages in the treatment of internal iliac artery aneurysm (IIAA) given the technical difficulties associated with open surgical repair deep within the pelvis. We describe the use of customized tapered stent-grafts in the exclusion of wide-necked IIAA in five male patients considered high-risk for conventional surgical repair, in whom the common and external iliac artery morphology precluded the use of standard endovascular devices. In each case, IIAA outflow was selectively embolized and the aneurysm neck excluded by placement of a customized tapered stent-graft across the internal iliac artery origin. This technique was extremely effective, with 100% technical success, no serious associated morbidity, and zero mortality. In all five patients sac size was stable or reduced on computed tomography follow-up of up to 3 years (mean, 24.4 months), with a primary patency rate of 100%. We therefore advocate the use of customized tapered stent-grafts as a further endovascular option in the management of IIAA unsuitable for conventional endovascular repair.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Repair of a Right-Sided Descending Thoracic Aortic Aneurysm Associated with a Right Aortic Arch and a Left Subclavian Artery Arising from a Kommerell's Diverticulum

This case report describes the endovascular repair of a right-sided descending thoracic aortic aneurysm associated with a right aortic arch and an aberrant left subclavian artery. A 76-year-old male with multiple comorbidities was incidentally found to have a right-sided descending thoracic aortic aneurysm with a maximum diameter of 6.2 cm. Additionally, there was a right aortic arch with a retroesophageal segment and separate arch branches arising in the following order: left common carotid artery, right common carotid artery, right subclavian artery, and left subclavian artery that was aberrant, arising from a Kommerrell's diverticulum. The aneurysm was successfully excluded by deployment of a Zenith TX1 36 x 32 x 20-mm stent-graft using wire traction technique via the left femoral and right brachial arteries in order to deal with two severe aortic angulations. At 18-month follow-up the patient was doing well, with aneurysm sac shrinkage to 5.9 cm and no signs of endoleak or migration. Endovascular repair of right-sided descending thoracic aortic aneurysms with a right arch and aberrant left subclavian artery is feasible, safe, and effective. In such rare configurations, which demand considerably increased technical dexterity and center experience, endovascular repair emerges as an attractive therapeutic option.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Treatment of Venous Aortorenal Bypass Graft Aneurysm Using a Stent-Graft

We present the case of a 77-year-old male patient who had undergone a bilateral venous aortorenal bypass graft 30 years previously. Thirteen years previously, the patient was shown to have a decrease in renal function, with mild shrinking of both kidneys; additionally, a stenosis was found in the left proximal anastomosis. At the most recent follow-up visit (1 year previously), ultrasound revealed an aneurysm (42 mm in diameter) of the left renal bypass graft; the finding was confirmed by CT angiography. A significant ostial stenosis of the left renal bypass graft was also confirmed. It was decided to place a self-expandable stent-graft into the aneurysm while also attempting to dilate the stenosis. Proximal endoleak after stent-graft placement necessitated the implantation of another, balloon-expandable stent-graft into the bypass graft ostium. Postprocedural angiography and follow-up by CT angiography at 3 months confirmed good patency of the stent-grafts and complete thrombosis of the aneurysmal sac, with preserved kidney perfusion. Renal function remained unaltered, while the hypertension is better controlled.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Treatment of Ruptured Abdominal Aortic Aneurysm with Aortocaval Fistula

Aortocaval fistula (ACF) is a rare complication of abdominal aortic aneurysm (AAA). We report the endovascular repair of an AAA rupture into the inferior vena cava. A 78-year-old woman was admitted to our hospital for acute hypotension. She presented with a pulsatile abdominal mass and became rapidly anuric. Abdominal computed tomography (CT) showed an AAA rupture into the inferior vena cava. The features of the AAA made it suitable for endovascular repair. To prevent pulmonary embolism caused by the presence of sac thrombosis near the vena cava lumen, a temporary vena cava filter was deployed before the procedure. A bifurcated stent-graft was placed with the patient under local anaesthesia, and the AAA was successfully treated. A transient type II endoleak was detected on CT 3 days after endograft placement. At routine follow-up 6 and 12 months after the procedure, the patient was in good clinical condition, and the type II endoleak had sealed completely. Endovascular treatment offers an attractive therapeutic alternative to open repair in case of ACF; however, only small numbers of patients have been treated, and long-term follow-up interval is lacking.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Type II Endoleak After Endovascular Repair of Abdominal Aortic Aneurysm: Effectiveness of Embolization

The purpose of this study was to report our experience in treating type II endoleaks after endovascular aneurysm repair (EVAR) of abdominal aortic aneurysms. Two hundred eighteen patients underwent EVAR with a Zenith stent-graft from January 2000 to December 2005. During a follow-up period of 4.5 {+-} 2.3 years, solely type II endoleak was detected in 47 patients (22%), and 14 of them underwent secondary interventions to correct this condition. Ten patients had transarterial embolization, and four patients had translumbar/transabdominal embolization. The embolization materials used were coils, thrombin, gelatin, Onyx (ethylene-vinyl alcohol copolymer), and glue. Disappearance of the endoleak without enlargement of the aneurysm sac after the first secondary intervention was achieved in only five of these patients (5/13). One patient without surveillance imaging was excluded from analyses of clinical success. After additional interventions in four patients and the spontaneous disappearance of type II endoleak in two patients, overall clinical success was achieved in eight patients (8/12). One patient did not have surveillance imaging after the second secondary intervention. Clinical success after the first secondary intervention was achieved in two patients (2/9) in the transarterial embolization group and three patients (3/4) in the translumbar embolization group. The results of secondary interventions for type II endoleak are unsatisfactory. Although the small number of patients included in this study prevents reliable comparisons between groups, the results seem to favor direct translumbar embolization in comparison to transarterial embolization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Management of Complex Renal Artery Aneurysms Using the Multilayer Stent

Since its approval as an innovative stent system for peripheral aneurysm management in May 2009, the Cardiatis Multilayer Stent (Cardiatis, Isnes, Belgium) has been applied in several clinical cases. The unique design of this multilayer stent decreases mean velocity and vorticity within the aneurysm sac immediate and causes thrombus to form, resulting in physiological exclusion of the aneurysm from the circulation, whereas branches and collaterals sprouting from the aneurysm remain patent. Here we present a case of a complex renal artery aneurysm successfully treated with a 6 Multiplication-Sign 30-mm Cardiatis Multilayer Stent.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Detection of Type II Endoleak After Endovascular Aortic Repair: Comparison Between Magnetic Resonance Angiography and Blood-Pool Contrast Agent and Dual-Phase Computed Tomography Angiography

PurposeThis prospective study was designed to assess the diagnostic value of magnetic resonance angiography (MRA) with blood-pool contrast agent (gadofosveset) in the detection of type-II endoleak after endovascular aortic repair (EVAR).MethodsThirty-two patients with aortic aneurysms who had undergone EVAR were included in this study. All patients were examined by dual-phase computed tomography angiography (CTA) as well as MRA with gadofosveset in the first-pass and steady-state phases. Two independent readers evaluated the images of CTA and MRA in terms of endoleak type II, feeding vessel, and image quality.ResultsMedian follow-up-time after EVAR was 22 months (range 4 to 59). Endoleak type II was detected by CTA in 12 of 32 patients (37.5%); MRA detected endoleak in all of these patients as well as in another 9 patients (n = 21, 65.6%), of whom the endoleaks in 6 patients showed an increasing diameter. Most endoleaks were detected in the steady-state phase (n = 14). The decrease in diameter of the aneurysmal sac was significantly greater in the patients without a visible endoleak that was visible on MRA (P = 0.004). In the overall estimation of diagnostic accuracy, MRA was judged superior to CTA in 66% of all examinations.ConclusionMRA with gadofosveset appeared superior to CTA, and has higher diagnostic accuracy, in the detection of endoleak after EVAR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Epithelioid Angiosarcoma With Metastatic Disease After Endovascular Therapy of Abdominal Aortic Aneurysm

Malignancies of the aortic wall represent a rare condition, and only a few reports have covered cases of sarcomas arising at the site of a prosthesis made of Dacron. A coincidence with endovascular repair has only been reported in one case to date. We report a patient with epithelioid angiosarcoma and metastatic disease, which was found in an aneurysmal sac after endovascular aortic repair for abdominal aortic aneurysm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Treatment of Multiple HIV-related Aneurysms Using Multilayer Stents

Complex peripheral aneurysm anatomy with major artery branches in the immediate vicinity and mycotic aneurysm often impede endovascular management using covered stent grafts. The Cardiatis Multilayer Stent (Cardiatis, Isnes, Belgium) is a recently approved innovative stent system for peripheral aneurysm management. Its multilayer design aims at decreasing mean velocity and vorticity within the aneurysm sac to cause thrombus formation while maintaining patency of branching vessels due to laminar flow. We present a case of bilateral subclavian artery aneurysms and perivisceral aortic aneurysms in an AIDS patient successfully treated with the Cardiatis Multilayer Stent at 18 months' follow-up.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quality Improvement Guidelines for Imaging Detection and Treatment of Endoleaks following Endovascular Aneurysm Repair (EVAR)

Major concerns after aortic aneurysm repair are caused by the presence of endoleaks, which are defined as persistent perigraft flow within the aortic aneurysm sac. Diagnosis of endoleaks can be performed with various imaging modalities, and indications for treatment are based on further subclassifications. Early detection and correct classification of endoleaks are crucial for planning patient management. The vast majority of endoleaks can be treated successfully by interventional means. Guidelines for Imaging Detection and Treatment of endoleaks are described in this article.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Treatment of a Symptomatic Thoracoabdominal Aortic Aneurysm by Chimney and Periscope Techniques for Total Visceral and Renal Artery Revascularization

Conventional endovascular therapy of thoracoabdominal aortic aneurysm with involving visceral and renal arteries is limited by the absence of a landing zone for the aortic endograft. Solutions have been proposed to overcome the problem of no landing zone; however, most of them are not feasible in urgent and high-risk patients. We describe a case that was successfully treated by total endovascular technique with a two-by-two chimney-and-periscope approach in a patient with acute symptomatic type IV thoracoabdominal aortic aneurysm with supra-anastomotic aneurysm formation involving the renal and visceral arteries and a pseduaneurismatic sac localized in the left ileopsoas muscle.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transretroperitoneal CT-guided Embolization of Growing Internal Iliac Artery Aneurysm after Repair of Abdominal Aortic Aneurysm: A Transretroperitoneal Approach with Intramuscular Lidocaine Injection Technique

This study was designed to evaluate the efficacy and safety of CT-guided embolization of internal iliac artery aneurysm (IIAA) after repair of abdominal aortic aneurysm by transretroperitoneal approach using the lidocaine injection technique to iliacus muscle, making window for safe needle path for three patients for whom CT-guided embolization of IIAA was performed by transretroperitoneal approach with intramuscular lidocaine injection technique. Transretroperitoneal access to the IIAA was successful in all three patients. In all three patients, the IIAA was first embolized using microcoils. The aneurysmal sac was then embolized with glue and coils without complication. With a mean follow-up of 7 months, the volume of the IIAAs remained stable without residual endoleaks. Transretroperitoneal CT-guided embolization of IIAA using intramuscular lidocaine injection technique is effective, safe, and results in good outcome.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Perigraft Plug Embolization of the Internal Iliac Artery and Implantation of a Bifurcated Stentgraft: One Treatment Option for Insufficient Tubular Stentgraft Repair of a Common Iliac Artery Aneurysm

We report an endovascular technique for the treatment of type Ia endoleak after a plain tubular stentgraft had been implanted for a large common iliac artery aneurysm with an insufficient proximal landing zone and without occlusion of the hypogastric in another hospital. CT follow-up showed an endoleak with continuous sac expansion over 12 months. This was classified as type Ia by means of dynamic contrast-enhanced MRI. Before a bifurcated stentgraft was implanted to relocate the landing zone more proximally, the still perfused ipsilateral hypogastric artery was embolized to prevent a type II endoleak. A guidewire was manipulated alongside the indwelling stentgraft. The internal iliac artery could then be selectively intubated followed by successful plug embolization of the vessel’s orifice despite the stentgraft being in place.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Aneurysm Neck Angle Change After Endovascular Aneurysm Repair Clinical Investigations

PurposeTo evaluate the aneurysm neck angle changes and post-endovascular aneurysm repair (EVAR) complications.MethodsWe retrospectively analyzed 72 cases of elective EVAR for abdominal aortic aneurysm among 109 consecutive cases from December 2005 to April 2014. Patients were divided into angulated and non-angulated groups. The angulated group was defined as neck angulation ≥60°. Neck angle was evaluated pre- and post-EVAR during short- (within 1 month), mid- (3–6 months), and long-term (>1 year) follow-up. Aneurysm sac diameter change, aneurysm neck morphology other than angulation, endoleaks, and other post-procedural complications were also documented.ResultsA total of 34 patients were enrolled in the angulated group. There were no statistical differences in age, sex, follow-up duration, and aneurysm neck profile between the two groups (p > 0.05). Both groups showed statistically significant and consistent decreases in angulation during the follow-up period (p < 0.01). The angulated group revealed 22.45 % more straightening than the non-angulated group. Recoil of the Endurant device occurred in the angulated group. No statistically significant intergroup differences were observed in any endoleaks, complications, or re-intervention rates (p > 0.05). Pre-EVAR angle was the only predictor for post-procedural angle change (p < 0.001).ConclusionEVAR is applicable for patients with highly angulated aneurysm neck and provides consistent neck straightening over long-term follow-up. Recoil was evident in the angulated group using the Endurant device.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Custom-Made Endograft for Endovascular Repair of Thoraco-Abdominal Aneurysm and Type B Dissection: Single-Centre Experience

AimsTo report a series of patients treated with the Jotec custom-made endograft for thoraco-abdominal aneurysms and dissections and identify predictive factors for re-intervention.MethodsWe retrospectively analysed 49 patients unsuitable for surgery, treated between 2011 and 2017 (71.3 ± 9.5 years; 15 females). Indications included Crawford type 4 aneurysm in 25 patients, type 3 in 13, type 2 in 4, type 1 in 2 and chronic aneurysmal dilatation of the false lumen following dissection in 5 cases. Mean aneurysm diameter was 58.7 ± 8.4 mm. The study aims were to assess procedural success, complications rate, mortality and long-term follow-up. We also analysed factors that predicted the need for re-intervention.ResultsThe endograft was successfully deployed in all patients, catheterization of the fenestration and/or branches was achieved in 152/156 (97.4%) vessels. Early complications occurred in 10 patients (3 paraplegia, 3 haemorrhages, pancreatitis, aortic rupture, iliac artery rupture, 2 strokes). Thirty-day mortality was 10.2% and 180-day mortality 14.3%; two non procedure related deaths occurred. Mean follow-up was 23.6 ± 29.9 months [range 1–80]. No patients needed surgical explantation or developed significant renal impairment. Endoleak rate was 34.6% and re-intervention rate 9.7%. The aneurysm sac reduced or was stable in 36/49, and enlarged in 9/49 patients prompting re-intervention. Primary, primary-assisted and secondary patency of fenestrations/branches at 80 months was 90, 96 and 100%. Re-intervention was required more frequently in braches than in fenestrations, most commonly the external type branches.ConclusionsThe results of the Jotec endograft are comparable to other devices, with acceptable complication and re-intervention rates. Fenestration and inner-branch should be preferred due to lower re-intervention rates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗