Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Robotics Technology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

High Precision In-Pipe Robot Localization with Reciprocal Sensor Fusion - 19516

Manual measurement of U-235 deposits in uranium enrichment piping is a costly, time consuming, and labor-intensive process that is a well-known cost and schedule driver. Autonomous, robotic innovation enabled by this research is revolutionizing the measurement speed, quality and safety of this important operation. The huge advantage is the robot's ability to measure from inside the pipes. The upside is sensing the geometry, appearance and radiometry directly. The downside is the inability to know precise, absolute position of the measurements in very long pipe runs. This paper develops the unprecedented localization required for this purpose. This paper presents the precise localization method designed for in-pipe radiation measurement robots. Unlike other in-pipe localization methods, this approach achieves millimeter-level accuracy in hundred-foot runs and does everything on one robot without relying on tether cable or communicating devices out of pipe, which is an important feature for nuclear in-pipe robot. It overcomes challenges usually encountered by in-pipe localization such as long travelling distance and operation time, narrow view angle, and featureless environment. The robot is equipped with encoders embedded in tracks which can record travelled distance, but encoder odometry drifts unacceptably due to slip and non-linearity. The robot also incorporates a laser range finder measuring the absolute distance, but range finder in long pipes has many misleading false measurements that are difficult to filter. The innovation here is to use one to filter/calibrate the other so that data used from the two sensors improve each other iteratively and reciprocally. The survey measurements accuracy of this localization method is proven by experiments comparing to ground truth and 'Zippering error' experiments that compare measurements to fixed features in pipes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The MegaMapper: A Stage-5 Spectroscopic Instrument Concept for the Study of Inflation and Dark Energy

In this white paper, we present the MegaMapper concept. The MegaMapper is a proposed ground-based experiment to measure Inflation parameters and Dark Energy from galaxy redshifts at $2 < z < 5$. In order to achieve path-breaking results with a mid-scale investment, the MegaMapper combines existing technologies for critical path elements and pushes innovative development in other design areas. To this aim, we envision a 6.5-m Magellan-like telescope, with a newly designed wide field, coupled with DESI spectrographs, and small-pitch robots to achieve multiplexing of at least 26,000. This will match the expected achievable target density in the redshift range of interest and provide a 10x capability over the existing state-of the art, without a 10x increase in project budget.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tele-robotics Requirements for Remote Handling in Nuclear Facilities - 17538

The main constraint in scientific nuclear facilities is the environmental conditions inside the operational areas which imply restrictive equipment requirements to resist high radiation levels and other restrictions related to magnetism, ultra-vacuum, and/or temperature. Robots for remote handling systems are required to perform inspection and maintenance operations since direct human intervention is not allowed, or constrained, under these environmental conditions. Several challenges have to be solved in tele-operation technologies in order to properly perform remote tasks in scientific nuclear radiation facilities. The main solutions described in this paper are based on using multiplexer for the transmission of signals and applying hybrid rate/position control algorithm so as to improve tele-manipulation in these environments. Both developments have been evaluated and discussed. (authors)

42 ENGINEERING↗

Online task-space motion control for positioner-coordinated multi-robot manufacturing systems

Incorporating multiple robotic manipulators into large-scale manufacturing systems enhances production efficiency and expands manufacturing capabilities beyond those of single-robot systems. Workpiece positioners in robotic manufacturing have demonstrated significant benefits for process optimization, but coordination strategies for multi-robot systems with shared positioners have received limited attention. This work presents a task-space coordinated trajectory-tracking control framework for multi-robot manufacturing systems, in which robots coordinate their motions within a shared, dynamic workpiece positioning frame. A workpiece positioner actively adjusts the pose of the manufactured component to enable greater operational concurrency and improve overall production efficiency. The proposed motion-coordination scheme employs a distributed and scalable architecture, supporting coordination across heterogeneous multi-robot systems. Two optimization methodologies are introduced to manage kinematic redundancies and maintain continuous, near-optimal operation throughout the manufacturing process. The first strategy exploits a task-space dimensionality reduction to achieve locally optimal configurations by leveraging symmetry-axis rotations of the tool. The second strategy utilizes the workpiece positioner to drive the coordinated robots toward stable and kinematically favorable configurations. For both optimization strategies, multiple objectives are defined to improve key performance metrics, including manipulability, configuration consistency, proximity to mechanical limits, and motion efficiency. Addressing a key limitation of existing coordination approaches, the framework is designed around online setpoint modification, allowing coordinated robots to respond effectively to in-situ process feedback. The proposed control framework is validated using the Robot Operating System (ROS) middleware on a combination of physical and simulated multi-robot system hardware.

Arbogast, Alex [ORNL] (ORCID:0000000154740723)↗

Concept and simulation study of a novel localization method for robotic endoscopic capsules using multiple positron emission markers

Purpose: Over the last decade, wireless capsule endoscope has been the tool of choice for noninvasive inspection of the gastrointestinal tract, especially in the small intestine. However, the latest clinical products have not been equipped with a sufficiently accurate localization system which makes it difficult to determine the location of intestinal abnormalities, and to apply follow-up interventions such as biopsy or drug delivery. In this paper, the authors present a novel localization method based on tracking three positron emission markers embedded inside an endoscopic capsule. Methods: Three spherical {sup 22}Na markers with diameters of less than 1 mm are embedded in the cover of the capsule. Gamma ray detectors are arranged around a patient body to detect coincidence gamma rays emitted from the three markers. The position of each marker can then be estimated using the collected data by the authors’ tracking algorithm which consists of four consecutive steps: a method to remove corrupted data, an initialization method, a clustering method based on the Fuzzy C-means clustering algorithm, and a failure prediction method. Results: The tracking algorithm has been implemented inMATLAB utilizing simulation data generated from the Geant4 Application for Emission Tomography toolkit. The results show that this localization method can achieve real-time tracking with an average position error of less than 0.4 mm and an average orientation error of less than 2°. Conclusions: The authors conclude that this study has proven the feasibility and potential of the proposed technique in effectively determining the position and orientation of a robotic endoscopic capsule.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation Hardened Electronics Destined For Severe Nuclear Reactor Environments

Post nuclear accident conditions represent a harsh environment for electronics. The full station blackout experience at Fukushima shows the necessity for emergency sensing capabilities in a radiation-enhanced environment. This NEET (Nuclear Energy Enabling Technologies) research project developed radiation hardened by design (RHBD) electronics using commercially available technology that employs commercial off-the-shelf (COTS) devices and present generation circuit fabrication techniques to improve the total ionizing dose (TID) hardness of electronics. Such technology not only has applicability to severe accident conditions but also to facilities throughout the nuclear fuel cycle in which radiation tolerance is required. For example, with TID tolerance to megarads of dose, electronics could be deployed for long-term monitoring, inspection and decontamination missions. The present work has taken a two-pronged approach, specifically, development of both board and application-specific integrated circuit (ASIC) level RHBD techniques. The former path has focused on TID testing of representative microcontroller ICs with embedded flash (eFlash) memory, as well as standalone flash devices that utilize the same fabrication technologies. The standalone flash devices are less complicated, allowing better understanding of the TID response of the crucial circuits. Our TID experiments utilize biased components that are in-situ tested, and in full operation during irradiation. A potential pitfall in the qualification of memory circuits is the lack of rigorous testing of the possible memory states. For this reason, we employ test patterns that include all ones, all zeros, a checkerboard of zeros and ones, an inverse checkerboard, and random data. With experimental evidence of improved radiation response for unbiased versus biased conditions, a demonstration-level board using the COTS devices was constructed. Through a combination of redundancy and power gating, the demonstration board exhibits radiation resilience to over 200 krad. Furthermore, our ASIC microprocessor using RHBD techniques was shown to be fully functional after an exposure of 2.5 Mrad whereas the COTS microcontroller units failed catastrophically at <100 krad. The methods developed in this work can facilitate the long-term viability of radiation-hard robotic systems, thereby avoiding obsolescence issues. As a case in point, the nuclear industry with its low purchasing power does not drive the semiconductor industry strategic plans, and the rapid advancements in electronics technology can leave legacy systems stranded.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Robotic Inspection Systems for In-situ Characterisation Prior to Decommissioning - 20306

The University of Bristol's South West Nuclear Hub is part of two large UK academic research collaborations aiming to reduce the costs of nuclear power by trialing innovative solutions to major decommissioning challenges. Robotics and Artificial Intelligence in Nuclear (RAIN) and the National Centre for Nuclear Robotics (NCNR) are the two collaborations tasked by the UK research councils to coordinate this activity, for the benefit of the nuclear industry. This paper presents a summary of Bristol's research aimed at generating and demonstrating a series of technologies ready for commercialization. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Automatic sample Dewar for MX beam-line

It is very common for crystals of large biological macromolecules to show considerable variation in quality of their diffraction. In order to increase the number of samples that are tested for diffraction quality before any full data collections at the ESRF*, an automatic sample Dewar has been implemented. Conception and performances of the Dewar are reported in this paper. The automatic sample Dewar has 240 samples capability with automatic loading/unloading ports. The storing Dewar is capable to work with robots and it can be integrated in a full automatic MX** beam-line. The samples are positioned in the front of the loading/unloading ports with and automatic rotating plate. A view port has been implemented for data matrix camera reading on each sample loaded in the Dewar. At last, the Dewar is insulated with polyurethane foam that keeps the liquid nitrogen consumption below 1.6 L/h. At last, the static insulation also makes vacuum equipment and maintenance unnecessary. This Dewar will be useful for increasing the number of samples tested in synchrotrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Robotic Measurement of Holdup Deposit Volume in Gaseous Diffusion Piping to Quantify U-235 Content - 18375

During D and D of old gaseous diffusion uranium enrichment facilities, radiometric assay of U-235 holdup in pipes is a costly, time consuming, and labor-intensive process. Subject to human interpretation using approximate modeling, radiometric assay introduces significant challenges. Taking advantage of routine demolition activities in which D and D cuts pipes open, robotic in-pipe assay is explored. The novel method introduced here generates models of the internal pipe and deposit surface geometries that are used to derive volumetric quantities. The pipe surface is sensed using a non-contact inductive proximity sensor and the deposit surface is sensed using an optical laser triangulation sensor. These sensors are mounted on a spinning disk and driven down the pipe to construct a helical point cloud of discrete measurements. Surfaces are fit to each of the two point clouds to create a watertight volume that represents the holdup. This provides the location and volume per foot of pipe that is used to compare against criticality incredible (CI) thresholds during evaluation. The robotic system collects data autonomously, deploying and returning to the same pipe opening from which it is launched. This provides redundant measurements of the pipe and deposit surfaces as well as odometry used in localization. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Robotic NDA of Holdup Deposits in Gaseous Diffusion Piping by Gamma Assay of Uranium-235 - 18331

This research exploits in-pipe access to develop robotically deployed, high-cadence, accurate, certain, paperless assay of U-235 in holdup deposits within process piping. Prior radiometric assay from outside the pipes suffered from manual deployment challenges, attenuation of detection through pipe walls, long counting times, approximate modeling, and shortfalls associated with transcription and human interpretation. These downsides limited the speed, quality, and economy of assay resulting in vast cost and budget consequences to D and D. D and D of outdated facilities cuts into these pipes as part of the demolition process, creating the unique, previously unexploited possibility of robotic in-pipe assay. The assay collimates radiation emanating from all but a short segment of pipe wall from reaching a gamma detector. Hence, the detector only views and measures source from a short segment of pipe at a given time. This is achieved by an innovative pair of collimating discs that are coaxial with the pipe and positioned fore and aft of the detector. The detector assembly is translated through pipes by an autonomous mobile robot. Beyond radiometric assay of U-235, the robot images and geometrically models the pipe interior and deposit appearance. The robot is recovered from the same pipe opening from which it is launched, hence it drives the same distance out and back, measuring the same deposits twice. This achieves redundant radiometric and odometric measurements which adds further to statistical significance of the method. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Universal folding pathways of polyhedron nets

Significance What makes an object successful at thermal folding? Protein scientists study how sequence affects the pathways by which chained amino acids fold and the structures into which they fold. Here we investigate the inverse problem: Starting with a 3D object as a polyhedron we ask, which ones, among the many choices of 2D unfoldings, are able to fold most consistently? We find that these “nets” follow a universal balance between entropy loss and potential energy gain, allowing us to explain why some of their geometrical attributes (such as compactness) represent a good predictor for the folding propensity of a given shape. Our results can be used to guide the stochastic folding of nanoscale objects into drug-delivery devices and thermally folded robots.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

spot_bt_ros v.0.1.0

SAND2024-08478O The spot_bt_ros tool allows users to easily construct complex autonomous behaviors for Boston Dynamic's Spot robot without having to overly rely on the Spot software development kit (SDK). This package specifically allows a user to run the Robot Operating System 2 alongside the SDK. Using a form-of-state machine called a "behavior tree,” the software develops different "leaves" or actions that the robot undergoes. Attaching multiple actions in sequence creates a "branch" and several of these make up the "tree." Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Kakish, Zahi↗

RoboCount{sup TM} 2020 - A Robotic Non-Destructive Waste Assay System - 19331

A robotic system for non-destructive assay of radioactive waste - RoboCount{sup TM} 2020ab - has been designed, manufactured, and a prototype delivered to a customer. RoboCount{sup TM} 2020 is based on an industrial 6-axis articulating robot platform, combined with a dedicated waste package platform and a high-resolution HPGe gamma spectrometer. The system enables measurement of waste packages including drums (100-l, 200-l, 400-l), crates (up to 1200 x 800 x 800 mm), 1 m{sup 3} flexible intermediate bulk containers (FIBC), and others. Assay type can be freely defined, ranging from currently accepted protocols such as segmented gamma scan (SGS) or integral gamma scan (IGS) to new protocols developed for specific non-cylindrical waste packages, e.g., measurement of FIBCs from all four sides and the top. As a result of the robotic hardware flexibility, reconfiguration of the system for a new task is a matter of software changes only. In addition, while primarily geared towards waste characterization, the system can be configured for free release (clearance) by installing a second detector and field-of-view shielding. The prototype is currently in operation at a NPP site in Europe where it is used for D and D waste characterization in crates and FIBCs. Additional features beyond the basic functionality have been implemented such as an automatic lead collimator change based on measured HPGe detector dead time and an automatic liquid nitrogen refill, performed by the robot via a docking station at predefined time intervals. (Use of electrically cooled HPGe detectors is also possible). (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Latent Effects of Radiation on Li-ion Batteries in Robots

The rapid development of Li-ion batteries (LIBs) is due to their high energy-density storage capability, which makes them suitable for application in both vehicles (e.g., electrified car) and electronic devices (e.g., cell phone, laptop, etc.), which are currently ubiquitous. Another less common but important application of LIBs is the powering of equipment in extreme environments such as robots operating in a nuclear rescue mission, unmanned vehicles surveying environments exposed to radiation, or vehicles and probes for outer space exploration. In our previous study, coin cells with lithium metal serving as the reference and counter electrode were assembled with either an irradiated cathode or irradiated electrolyte. We have observed an increase in premature battery failure and degradation of capacity of the battery made from irradiated cathodes and battery made from the irradiated electrolyte. For the group with cathodes irradiated to a 9.8 Mrad cumulative dose, the resistance was 2-3 times higher than the control group. On the other hand, cells with irradiated electrolyte showed increased resistance even at very low dose levels. Most importantly, a significant color change to the irradiated electrolyte after a long-term storage in a glove box has been observed. However, the electrolyte did not show any noticeable change immediately after irradiation. We name this phenomenon latent effects, which is more significant than the damage received by batteries due to initial dose. Also, electrolyte irradiated to a medium dose (1.6 Mrad) showed a poorer performance (higher failure rate, higher resistance) than those cells which received high dose (5 Mrad). We attribute this to the latent effect because this group battery was unintentionally assembled 3 days after initial electrolyte irradiation. The existence of latent effects implies that in space missions or post-accident events, instruments equipped with LIBs may fail unpredictably at post-irradiation stages, even if they survive the initial dose or the performance tests conducted after the initial dose. These instruments may fail several days or even weeks after irradiation, depending on the initial cumulative dose and dosage rate. For comprehending the influence of latent effects on the entire battery instead of on the individual components, we performed an in-situ cycling of coin cells made in-house, where the batteries were cycled under irradiation and then cycled again to evaluate their overall capacity fade, cyclability, and cell resistance. Additionally we investigated the effects of battery fading due to radiation on the performance of a drone.

25 ENERGY STORAGE↗

A high-throughput experimentation platform for data-driven discovery in electrochemistry

Automating electrochemical analyses combined with artificial intelligence is poised to accelerate discoveries in renewable energy sciences and technologies. This study presents an automated high-throughput electrochemical characterization (AHTech) platform as a cost-effective and versatile tool for rapidly assessing liquid analytes. The Python-controlled platform combines a liquid handling robot, potentiostat, and customizable microelectrode bundles for diverse, reproducible electrochemical measurements in microtiter plates, minimizing chemical consumption and manual effort. To showcase the capability of AHTech, we screened a library of 180 small molecules as electrolyte additives for aqueous zinc metal batteries, generating data for training machine learning models to predict Coulombic efficiencies. Key molecular features governing additive performance were elucidated using Shapley Additive exPlanations and Spearman’s correlation, pinpointing high-performance candidates like cis-4-hydroxy-d-proline, which achieved an average Coulombic efficiency of 99.52% over 200 cycles. The workflow established herein is highly adaptable, offering a powerful framework for accelerating the exploration and optimization of extensive chemical spaces across diverse energy storage and conversion fields.

Lin, Dian-Zhao [Johns Hopkins University, Baltimor↗

Radioactive Source Localization via Bayesian Particle Filter

In the event of a misplaced radioactive source or other emergency situation, measuring a radiation field, mapping its distribution, and determining a source location are essential tasks to ameliorating the situation. However, radiation fields may be extremely hazardous to human surveyors and minimizing received radiation doses is just as essential. Robots appear to be a potential solution to these problems. Beyond simply measuring radiation, the robot's computer processing capabilities offer a way to apply complex data analysis methods to radiation measurements in real-time. Methods which predict likely source locations can then feed this information into other processes, potentially improving path planning and enabling more efficient measurements. Given a robot mounted with a gamma-ray detector, can we: develop a methodology to account for detector performance across a wide range of source angles, distances, and photon energies? operate an autonomously navigating robot to effectively survey and characterize an area of interest? implement a data analysis method, conventionally used in measurements of motion, for source localization purposes? An open-source TurtleBot 3 robot, running Robot Operating System (ROS) on Ubuntu 16.04 LTS, was fitted with a Kromek GR1{sup R} Cadmium Zinc Telluride (CZT) solid-state gamma-ray detector. As a part of ROS, the packages OpenSlam, gmapping, and amcl were used to perform Simultaneous Localization and Mapping (SLAM), determining the robot's position and mapping the surrounding area. Data was acquired via Lidar mounted on top the TurtleBot 3. Detector Calibration Fit: The equation was fit to 365 counts of various energies, distances, and angles. A MATLAB{sup R} program was written to simulate measurements taken a robot on a random walk, with count data and positions discretized into finite element pixels. Using this program, a sample of 100 runs was performed on a map with a simulated source at the center, with a total of 200 of 2 pixels each. Similarly, multiple runs of the filter were performed on recorded robot measurement data. In both simulation and real tests, when corrected for errors (particles placed outside of bounds or on the robot, and simulation-specific errors), corresponding t-tests of predicted x and y-coordinates were within a 95% confidence interval of the actual position. For the real trial, these positions are slightly skewed right in the x-axis as the robot remained mainly to the left side of the source within the sample area. These simulations demonstrate potential validity for the usage of a particle filter as method of radioactive source localization. In the future, true real-time implementation and data fusion may further augment the performance of the robot to localize lost sources. Additionally, identification of multiple sources, determination of source types, and usage of a collimator are areas to potentially be explored.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗