Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Relays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Bulk Electric System Protection Model Demonstration with 2011 Southwest Blackout in DCAT

Protection equipment modeling is critical to power systems planning and operational studies, it enables more accurate system response when control actions including protection relays and remedial action schemes (RAS) are adequately modeled and assessed. This paper incorporates a generic protection philosophy to the Dynamic Contingency Analysis Tools (DCAT), and demonstrates its effectiveness by modeling 2011 Pacific Southwest Blackout event autonomously.

Bulk Electric System, Protection, Blackout, DCAT↗

A Lunar Farside Low Radio Frequency Array for Dark Ages 21-cm Cosmology

An array of low-frequency dipole antennas on the lunar farside surface will probe a unique, unexplored epoch in the early Universe called the Dark Ages. It begins at Recombination when neutral hydrogen atoms formed, first revealed by the cosmic microwave background. This epoch is free of stars and astrophysics, so it is ideal to investigate high energy particle processes including dark matter, early Dark Energy, neutrinos, and cosmic strings. A NASA-funded study investigated the design of the instrument and the deployment strategy from a lander of 128 pairs of antenna dipoles across a 10 kmx10 km area on the lunar surface. The antenna nodes are tethered to the lander for central data processing, power, and data transmission to a relay satellite. The array, named FARSIDE, would provide the capability to image the entire sky in 1400 channels spanning frequencies from 100 kHz to 40 MHz, extending down two orders of magnitude below bands accessible to ground-based radio astronomy. The lunar farside can simultaneously provide isolation from terrestrial radio frequency interference, the Earth's auroral kilometric radiation, and plasma noise from the solar wind. It is thus the only location within the inner solar system from which sky noise limited observations can be carried out at sub-MHz frequencies. Through precision calibration via an orbiting beacon and exquisite foreground characterization, the farside array would measure the Dark Ages global 21-cm signal at redshifts z~35-200. It will also be a pathfinder for a larger 21-cm power spectrum instrument by carefully measuring the foreground with high dynamic range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Apparatus for real-time size-distributed measurement of aerosol mass concentration

An impactor, system and method for performing real-time measurements of particles in aerosol gases. The impactor comprises a plurality of cascading stages having impaction plates, mass-measurement mechanisms retained on the impaction plates, and a nozzle plate. A signal line associated with each of the plurality of cascading stages is configured to relay signals from the mass-measurement mechanism of the associated stage to a computer-based system configured to receive the transmitted signals from the signal lines, and to correlate changes in the resonant frequencies to particle concentrations in real time.

Chen, Modi↗

Investigation of INL Site Implementation of ARG-US

The Packaging Certification and Life Cycle Management department at Argonne National Laboratory (ANL) developed a suite of monitoring systems collectively referred to here as ARG-US. ARG-US is used to provide necessary data for nuclear facility and system operation and maintenance. ARG-US has been previously demonstrated in hot cells, radioactive material (RAM) storage areas, and RAM shipment trucks. It has also been installed directly on RAM storage and shipment containers. ARG-US offers some unique advantages over other commercially available systems by using wireless data connections, battery power supplies, and customizable monitoring methods. Idaho National Laboratory (INL) has been tasked with investigating applications for ARG-US at INL site facilities, which are operated by several different contractors. The initial investigation scope centered on CPP-603 Wet & Dry Fuel Storage Facility in relation to the upcoming DOE Spent (SNF) Packaging Demonstration. The investigation has been led by the Used Fuel Management Department in the Nuclear Science and Technology Directorate. This investigation is expected to recommend processes or facilities at the INL site at which to implement ARG-US systems. INL has engaged local site technical and oversite representatives, security, nuclear safeguards, and program management to identify good candidates for ARG-US test implementations. INL has identified high-level goals for any INL site implementation of ARG-US: provide unique testing environments, prompt development of new monitoring methods/techniques for the ARG-US suite, and acquire useful monitoring for the user facility. To these ends, INL suggests 3 program areas for further investigation: CPP-603 Fuel Handling Cave (FHC), legacy mixed waste storage systems at Idaho Nuclear Technology & Engineering Center (INTEC) known as the “tank farm”, and periodic and emergency environmental monitoring. This progress report relates activities undertaken in this investigation, describes the preliminary areas of interest for limited scope ARG-US testing or implementation, and relays expected actions needed to complete the task scope. This report offers an opportunity to the program sponsor, technical leads at ANL, and INL site representatives to give feedback on the initial assessment and make recommendations on the forthcoming activities.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Real-Time Hardware-in-the-Loop Testbed to Evaluate FLISR Implemented with OpenFMB

With the increasing complexity of the distribution smart grid architecture, algorithms such as the fault location, isolation, and service restoration (FLISR) scheme rely on robust communications that are resilient to natural and man-made adverse conditions and exhibit robustness. Existing communications infrastructure for information exchange are centralized at the distribution management system, with very little autonomy or intelligence at the grid-edge. As a first step towards achieving grid-edge self-healing, this paper aims to bridge this shortcoming by implementing a centrally coordinated rules-based FLISR scheme and integrating it with Open Field Message Bus (OpenFMB), which is a flexible publish-subscribe architecture with the potential to enable point-to-multipoint communications and is more robust and resilient to natural and man-made adverse conditions. A proof of concept is developed to validate the centrally coordinated FLISR and OpenFMB mounted on an SEL-3360 computer that interacts with a simple feeder network of five SEL-651R relays, an SEL-3530 RTAC, and a hardware-in-the-loop testbed. Results demonstrate the efficacy of this approach in enabling direct, low-latency information exchange. OpenFMB's publish-subscribe data model also opens new ways to enable grid-edge interoperability among devices of different vendors interacting with different protocols.

Sundararajan, Aditya↗

Use of Machine Learning on PMU Data for Transmission System Fault Analysis

Synchrophasor technology has been used for monitoring, control, and protection of bulk power system for over 10 years. Deployment of phasor measurement units (PMUs) in the USA power system has surpassed 3000 units installed in the transmission substations as stand-alone intelligent electronic devices (IEDs) or as a software add-on to other devices such as digital protective relays (DPRs) or digital fault recorders (DFRs). By now, thousands of terabytes of PMU data may have been captured and stored by various transmission system operators (TSOs) and independent system operators (ISOs). This creates an opportunity to deploy advanced machine learning (ML) techniques to detect and classify faults recorded by PMUs automatically to be used by the system operators for rapid, critical decision-making when manual analysis of the past or unfolding events is not feasible. In this paper we offer a brief background on how the automated fault analysis may be done using DPR and/or DFR data, and compare some of the legacy approaches to the new ML approaches in the context of the system-wide PMU recordings. We then offer insights from developing practical ML solutions that have been applied on field recordings captured by close to 450 PMUs from all three US interconnections (Western, Eastern and ERCOT) over two years (2016-2017). We identify and illustrate ML challenges we addressed: inaccurate data, data with scarce and temporally imprecise fault labels, data recorded by PMUs sparsely located at substations resulting in the fault records taken afar from the ends of the faulted lines, data containing only positive sequence values, and data taken at different voltage levels. We then illustrate the ML model results for fault analysis under different application scenarios. The novelty of this study is not only in the design, implementation, and performance analysis of the ML algorithms, but also in the use of advanced fault modelling and simulation approaches to improve the training results when developing supervised ML models for fault detection and classification. Extensive simulations of faults were conducted on a 14-bus power system to create a training dataset with over 1400 accurately labelled faults. This dataset was applied to enhance the accuracy of fault detection and classification of machine learning-based models trained with small number of labelled faults in large datasets recorded in the grid interconnections ranging from 5,000 to 70,000 buses.

Synchrophasors, Machine Learning, Fault Analysis, ↗

Fluid level and conductivity sensor for high temperature applications

A fluid level and conductivity sensor having a sensing probe with four electrodes disposed therein particularly suited for high temperature applications. A distal end of the second and third electrodes are positioned a distance from the sensing end that is greater than distal ends of the first and fourth electrodes. The sensor includes an electronics system having a signal relay system for receiving signals from each of the electrodes and switching between different measurement modes by determining a resistance between selected pairs of electrodes based on instructions from the microcontroller. The measurement modes include a conductivity measurement mode in which a resistance between the first and fourth electrodes is determined, and a fluid level measurement mode in which a resistance between the first and third electrodes is determined and compared to a resistance between the second and third electrodes.

Holland, Justin M.↗

A Data-Driven Approach for High-Impedance Fault Localization in Distribution Systems: Preprint

Accurate and quick identification of high-impedance faults (HIFs) is critical for the reliable operation of distribution systems. Unlike other faults in power grids, HIFs are very difficult to detect by conventional overcurrent relays due to the low fault current. Although HIFs can be affected by various factors, the voltage-current characteristics can substantially imply how the system responds to the disturbance and thus provides opportunities to effectively localize HIFs. In this work, we propose a data-driven approach for the identification of HIF events. To tackle the nonlinearity of the voltage-current trajectory, first, we formulate optimization problems to approximate the trajectory with piecewise functions. Then we collect the function features of all segments as inputs and use the support vector machine approach to efficiently identify HIFs at different locations. Numerical studies on the IEEE 123-node test feeder demonstrate the validity and accuracy of the proposed approach for real-time HIF identification.

explainable artificial intelligence↗

High-Throughput Custom Monitoring for the Mu2e TDAQ System

In this project we are studying the application of programmable network hardware to provide a custom monitoring capability for the Mu2e Trigger and Data Acquisition System (TDAQ) system. The goal of the Mu2e experiment is to search for a charged-lepton flavor violating processes where a negative muon converts into an electron in the field of an aluminum nucleus. This experiment is intended to improve by four orders of magnitude the search sensitivity reached so far. We have a working prototype of a system that provides high-throughput, custom monitoring for the Mu2e TDAQ system. The custom Mu2e network packet header format is parsed as it crosses the network switch. Parsing extracts bits that convey information about error states at read-out controllers (ROCs). This information is periodically relayed to the switch controller, which in turn alerts experiment operators.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Warrick Conductivity Level Controllers Series 3H

This is my internship poster. In the poster I talk about the level controllers that I wired together and installed to support electrolysis testing systems in efforts to make the systems more efficient and run based on the communication between devices to ensure a closed loop system that can run on its own in a safe and controlled manner. I included pictures of some of the wiring as well as the level sensor devices and relays. I also included pictures of the tanks that will be filled at different heights with deionized water based on where the level sensors are.

08 HYDROGEN↗

Studying the Impact of IBR Modeling on the Commonly Applied Transmission Line Protective Elements

It is a well-accepted fact that detailed inverter-based resource (IBR) models are needed for electromagnetic transient (EMT) studies, especially for protection studies and protection designs. However, it is not clear which modeling aspects should be included in the EMT model to accurately represent the IBR fault responses. Therefore, this paper addresses this gap by evaluating the impact of key modeling aspects (DC source, inverter model, power control, current/voltage control, and current limiting) on the response of protective relay elements both qualitatively and quantitatively. Both grid-following (GFL) and grid-forming (GFM) IBR models are comprehensively evaluated through a simplified real-world transmission network by varying the IBR modeling aspects, fault locations, and types. The insights and findings from this paper will benefit the power system protection community because this work provides modeling requirements and guidelines for IBR modeling so that correct IBR models will be used for protection scheme settings design.

grid-following inverter↗

Innovative PLC Design for Optimized Potable Water Managment

My project here at Idaho National Laboratory (INL) was to work on Potable Water PLC Design (Programmable Logic Controllers). I was tasked in making a new panel design for the PLC system that will be moved from TRA BLDG 696 to TRA BLDG 608. This design needed to be updated since the old PLC system being about 20 years old. The manufacturer of the MicroLogix 1200 life expectancy showed it to be 10-20 years, and the system was discontinued in 2017. The new system we implemented was called CompactLogix Controller 5380, along with a new 24 VDC/10 Amp Power Supply. I made a design using Microsoft Visio, with the new material. But we needed to add it onto an Aluminum Panel that the system will be mounted onto, we need Unistrut’s for the aluminum panel to be mounted to. Some of the material we will still be using, like the R1 Alarm Relay, will be moving with the PLC system. The rest of the material will be new supplies that need to be updated systems, which the site is waiting for to complete the PLC system.

47 - OTHER INSTRUMENTATION↗

Evaluation of a Reduced-Order Model for IBR Fault Response Representation via OEM Blackbox Models: Preprint

Driven by the need to capture the electromagnetic transients of transmission lines, inverter switching behavior, and detailed control systems, electromagnetic transient (EMT) studies have become increasingly important in industry, such as IBR interconnection study and fault study. However, original equipment manufacturer (OEM) inverter models typically include extensive parameters and proprietary settings that are unavailable to protection engineers. This paper introduces a data-driven, reduced-order model (ROM) developed as a PSCAD library component for use in EMT-based fault studies. The ROM replicates key OEM model behaviors without requiring detailed knowledge of control design or parameterization. The accompanying Python automation scripts streamline data generation, parameter fitting, and validation. The ROM's performance is demonstrated through comparison with both IEEE 2800-compliant and non-compliant OEM models in a real-world power system. Relay responses show nearly identical results, while simulation runtime is reduced by an average of 32.8\%, highlighting the ROM's practicality for protection engineers.

14 SOLAR ENERGY↗

CONTROL AND DATA ACQUISITION IN A CYBER-PHYSICAL MIDSTREAM TESTBED

This thesis presents the development of a laboratory-scale cyber–physical midstream pipeline testbed designed to address this gap and support research in industrial control systems security. The platform integrates pumps, valves, sensors, programmable logic controllers (PLCs), and a human–machine interface (HMI) to emulate the monitoring and control architecture of real pipeline operations. The physical process is implemented as a closed-loop liquid circulation system designed to replicate flow behavior characteristic of midstream pipeline infrastructure. The testbed enables real-time data acquisition of key process variables, including flow rate and pressure facilitating the generation of datasets representative of normal pipeline operation. A threat model encompassing common ICS attack vectors was developed, including sensor spoofing, command injection, false data injection, denial-of-service attacks, and relay manipulation. Multiple attack scenarios were implemented and evaluated to demonstrate how cyber intrusions targeting sensors, actuators, networks, and software propagate into measurable physical consequences in pipeline flow and pressure. The developed platform serves as a practical, cost-effective environment for experimentation, education, and future cybersecurity research in midstream pipeline systems.

42 ENGINEERING↗

Instrument design for an inertial confinement fusion ion temperature imager

A mix of contaminant mass is a known, performance-limiting factor for laser-driven inertial confinement fusion (ICF). It has also recently been shown that the contaminant mass is not necessarily in thermal equilibrium with the deuterium–tritium plasma. Contaminant mass temperature is one of the dominant uncertainties in contaminant mass estimates. The MixIT diagnostic is a new and potentially transformative diagnostic, capable of spatially resolving ion temperature. The approach combines principles of neutron time-of-flight and neutron imaging diagnostics. The information from the MixIT diagnostic can be used to optimize ICF target and laser drive designs as well as provide key constraints on ICF radiation-hydrodynamic simulations that are critical to contaminant mass estimates. This work details the design and optimization of the major components of the MixIT diagnostic: the neutron aperture, the neutron detector (scintillator), and the recording system.

47 OTHER INSTRUMENTATION↗