Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Raman Spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

X-ray diffraction analysis and scanning micro-Raman spectroscopy of structural irregularities and strains deep inside the multilayered InGaN/GaN heterostructure

High-resolution X-ray diffraction analysis and scanning confocal Raman spectroscopy are used to study the spatial distribution of strains in the In{sub x}Ga{sub 1-x}N/GaN layers and structural quality of these layers in a multilayered light-emitting diode structure produced by metal-organic chemical vapor deposition onto (0001)-oriented sapphire substrates. It is shown that elastic strains almost completely relax at the heterointerface between the thick GaN buffer layer and In{sub x}Ga{sub 1-x}N/GaN buffer superlattice. It is established that the GaN layers in the superlattice are in a stretched state, whereas the alloy layers are in a compressed state. In magnitude, the stretching strains in the GaN layers are lower than the compressive strains in the InGaN layers. It is shown that, as compared to the buffer layers, the layers of the superlattice contain a smaller number of dislocations and the distribution of dislocations is more randomly disordered. In micro-Raman studies on scanning through the thickness of the multilayered structure, direct evidence is obtained for the asymmetric gradient distributions of strains and crystal imperfections of the epitaxial nitride layers along the direction of growth. It is shown that the emission intensity of the In{sub x}Ga{sub 1-x}N quantum well is considerably (more than 30 times) higher than the emission intensity of the GaN barrier layers, suggesting the high efficiency of trapping of charge carriers by the quantum well.

36 MATERIALS SCIENCE↗

Self-Assembly of Large Gold Nanoparticles for Surface-Enhanced Raman Spectroscopy

Performance of portable technologies from mobile phones to electric vehicles is currently limited by the energy density and lifetime of lithium batteries. Expanding the limits of battery technology requires in situ detection of trace components at electrode–electrolyte interphases. Surface-enhance Raman spectroscopy could satisfy this need if a robust and reproducible substrate were available. Gold nanoparticles (Au NPs) larger than 20 nm diameter are expected to greatly enhance Raman intensity if they can be assembled into ordered monolayers. A three-phase self-assembly method is presented that successfully results in ordered Au NP monolayers for particle diameters ranging from 13 to 90 nm. The monolayer structure and Raman enhancement factors (EFs) are reported for a model analyte, rhodamine, as well as the best performing polymer electrolyte salt, lithium bis(trifluoromethane)sulfonimide. Experimental EFs for the most part correlate with predictions based on monolayer geometry and with numerical simulations that identify local electromagnetic field enhancements. Lastly, the EFs for the best performing Au NP monolayer are between 10 6 and 10 8 and give quantitative signal response when analyte concentration is changed.

36 MATERIALS SCIENCE↗

Coronagraphic Notch Filter for Raman Spectroscopy

A modified coronagraph has been proposed as a prototype of improved notch filters in Raman spectrometers. Coronagraphic notch filters could offer alternatives to both (1) the large and expensive double or triple monochromators in older Raman spectrometers and (2) holographic notch filters, which are less expensive but are subject to environmental degradation as well as to limitations of geometry and spectral range. Measurement of a Raman spectrum is an exercise in measuring and resolving faint spectral lines close to a bright peak: In Raman spectroscopy, a monochromatic beam of light (the pump beam) excites a sample of material that one seeks to analyze. The pump beam generates a small flux of scattered light at wavelengths slightly greater than that of the pump beam. The shift in wavelength of the scattered light from the pump wavelength is known in the art as the Stokes shift. Typically, the flux of scattered light is of the order of 10 7 that of the pump beam and the Stokes shift lies in the wave-number range of 100 to 3,000 cm 1. A notch filter can be used to suppress the pump-beam spectral peak while passing the nearby faint Raman spectral lines. The basic principles of design and operation of a coronagraph offer an opportunity for engineering the spectral transmittance of the optics in a Raman spectrometer. A classical coronagraph may be understood as two imaging systems placed end to end, such that the first system forms an intermediate real image of a nominally infinitely distant object and the second system forms a final real image of the intermediate real image. If the light incident on the first telescope is collimated, then the intermediate image is a point-spread function (PSF). If an appropriately tailored occulting spot (e.g., a Gaussian-apodized spot with maximum absorption on axis) is placed on the intermediate image plane, then the instrument inhibits transmission of light from an on-axis source. However, the PSFs of off-axis light sources are formed off axis - that is, away from the occulting spot - so that they become refocused onto the final image plane.

Cohen, David↗

Reimagining pH Measurement: Utilizing Raman Spectroscopy for Enhanced Accuracy in Phosphoric Acid Systems

Measurement of pH is an integral component of chemical studies and process control; however traditional pH probes are difficult to utilize in harsh or complex chemical systems. Optical spectroscopy-based on-line monitoring offers a powerful and novel route for characterizing system parameters, such as pH, and is well adapted to deployment in harsh environments or chemically complex systems. Specifically, Raman spectroscopy combined with chemometric analysis can provide an improved method of on-line pH measurement. Therefore, multivariate curve resolution analysis of Raman spectra can be utilized to determine speciation as a function of pH and subsequent chemometric modeling can be used to correlate spectral response to pH. This was demonstrated with phosphoric acid, a chemical system known to challenge traditional pH probes. Raman spectra exhibit clear changes with pH due to changing speciation, and chemometric modeling can be successfully utilized to correlate those fingerprints to pH. Using this approach, true pH of the phosphoric acid system can be measured with greater accuracy than with traditional pH probes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Raman Spectroscopy Based On-Line, Real-Time Monitoring to Reduce Composition Uncertainties: Enhanced sensitivity through optimization of Raman Parameters

Optical spectroscopy-based on-line monitoring of Hanford processing streams can enable real-time characterization of chemical composition of process streams and batches, ultimately enabling and enhancing process control. It can provide immediate feedback on process conditions and has the potential to reduce the needed number of grab sample collections, thereby reducing times and costs associated with laboratory processing. Here we discuss the utilization of Raman spectroscopy to quantify multiple target analytes that are common within Hanford tanks and waste processing streams. Analytes include: nitrate, nitrite, carbonate, chromate, sulfate, phosphate, hydroxide, oxalate, ammonia, and aluminate. Most notably in this work, Raman applications to low-concentration streams are explored and optimized. Raman instrument specifications are compared; specifically, the impact of utilizing three different Raman excitation wavelengths, 405, 532, and 671 nm, is discussed. Also, Raman data collection parameters such as collection time and spectral averaging are measured and discussed. Finally, optical libraries of chemical targets were collected using optimized collection parameters and chemometric models were built to automate quantification of chemical targets. These models were validated through application to simulants and real Hanford process samples. Chemometric models performed well on both training and validation sets, suggesting these approaches can be successfully applied to on-line and real-time monitoring of low concentration Hanford processing streams. The use of the combine Raman wave lengths with the enhanced chemometric models for the low concentration streams significantly improved the chemical detection levels and significantly reduced uncertainties of those measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation into the structure of ceramic Li{sub x}Na{sub 1-x}Ta{sub 0.1}Nb{sub 0.9}O{sub 3} solid solutions by X-ray analysis and Raman spectroscopy

The structure of ceramic solid solutions Li{sub x}Na{sub 1-x}Ta{sub 0.1}Nb{sub 0.9}O{sub 3} has been investigated by full-profile X-ray diffraction analysis and Raman spectroscopy. It is shown that their structure for all x values is similar to the NaNbO{sub 3} structure. The structure of NaTa{sub 0.1}Nb{sub 0.9}O{sub 3} solid solutions (x = 0) is characterized by the sp. gr. Pbcm, and the structure of Li{sub x}Na{sub 1-x}Ta{sub 0.1}Nb{sub 0.9}O{sub 3} solid solutions with x = 0.05, 0.1, and 0.16 is characterized by the sp. gr. P2{sub 1}ma. The unit-cell parameters decrease with an increase in x. At x = 0, doubled values of the parameter c and, correspondingly, the unit-cell volume are observed in the antiferroelectric phase. This fact is confirmed by the form of the vibrational spectrum in the region of stretching modes of oxygen atoms along the polar axis.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Molecular velocimetry using stimulated Raman spectroscopy

Molecular flow velocity of N2 was measured in a supersonic wind tunnel using inverse Raman spectroscopy. This technique employs the large Doppler shift exhibited by the molecules when the pump and probe laser beams are counter-propagating (backward scattering). A retrometer system is employed to yield a vibration-free optical configuration which has the additional advantage of obtaining both the forward and backward scattered spectra simultaneously. The linebreadths and their relative Doppler shift can be used to determine the static pressure, translational temperature, and molecular flow velocity. A demonstration of the concept was performed in a supersonic wind tunnel and included: (1) measurements over the Mach number range 2.50 to 4.63; (2) static pressure measurements (at Mach 2.50) corresponding to a Reynolds number per foot range of 1 to 5 x 10 to the 6th power; and (3) measurements behind the shock wave of a flat plate model.

Exton, R. J.↗

Investigation of the High-Pressure Behaviors of Amblygonite by Single-Crystal X-ray Diffraction, Raman Spectroscopy, and DFT Calculations

In the present study, we extensively explored the high-pressure behaviors and vibrational properties of amblygonite LiAlPO 4 F with elevated pressures up to 34.3 GPa based on single-crystal X-ray diffraction measurements, Raman spectroscopy, and DFT calculations. The compressibility and elastic properties of amblygonite were determined first. Specifically, the obtained isothermal bulk modulus of LiAlPO 4 F is 128(4) GPa and the triclinic phase exhibited anisotropic compression with axial compressibility β c > β a > β b with a ratio of 1.11:1.00:1.20. The Raman spectra showed no indication of phase transformation and were used to obtained mode Grüneisen parameters. The average Grüneisen parameter for PO 4 tetrahedral sites was smaller than for the LiO 4 F sites. Our results provide new insights into the phase stability and elastic properties of lithium-fluorite granites at extreme conditions.

36 MATERIALS SCIENCE↗

Raman spectroscopy and cathodoluminescence characteristics of order-disorder Ba(Zn{sub 1/3}Ta{sub 2/3})O{sub 3} ceramics

The order-disorder transition in Ba(Zn{sub 1/3}Ta{sub 2/3})O{sub 3} (BZT) was characterized by using Raman spectroscopy, transmission electron microscopy (TEM), and cathodoluminescence (CL) microscopy. The 1:2 ordered structure of pure BZT ceramics was replaced by a 1:1 ordered structure at 1650 deg. C and the 1:1 ordered structure of BZT sintered at 1650 deg. C exhibited a 1:2 ordered structure when it was reannealed at 1500 deg. C for 12 h. The A{sub 1g} lines in the Raman spectrum of the sintered and reannealed samples were shifted to lower and higher wavenumbers, respectively. From the CL analysis, the 1:1 ordered BZT exhibited mainly three emission bands at around 533.2 (2.32 eV), 599.1 (2.07 eV), and 682.1 nm (1.81 eV), whereas the 1:2 ordered BZT exhibited mainly five bands at 346.4 (3.58 eV), 427.5 (2.90 eV), 520.9 (2.38 eV), 593.0 (2.09 eV), and 678.9 nm (1.82 eV). The strongest band originating from 2.32 to 2.38 eV was broadened, and the band center shifted towards a higher and lower wavelength in the 1:1 and 1:2 ordered BZT, respectively. Additional bands at around 346 and 427 nm in the grain interior of the annealed sample were strongly related to the 1:2 ordering of BZT.

36 MATERIALS SCIENCE↗

Impact of Surface Enhanced Raman Spectroscopy in Catalysis

Catalysis stands as an indispensable cornerstone of modern society, underpinning the production of over 80% of manufactured goods and driving over 90% of industrial chemical processes. As the demand for more efficient and sustainable processes grows, better catalysts are needed. Understanding the working principles of catalysts is key, and over the last 50 years, surface-enhanced Raman Spectroscopy (SERS) has become essential. Discovered in 1974, SERS has evolved into a mature and powerful analytical tool, transforming the way in which we detect molecules across disciplines. In catalysis, SERS has enabled insights into dynamic surface phenomena, facilitating the monitoring of the catalyst structure, adsorbate interactions, and reaction kinetics at very high spatial and temporal resolutions. This review explores the achievements as well as the future potential of SERS in the field of catalysis and energy conversion, thereby highlighting its role in advancing these critical areas of research.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Raman spectroscopy of reaction fields induced by plasma in supercritical CO{sub 2}

The characteristic microstructures of supercritical fluids, such as density fluctuation near the critical point, in reaction fields induced by low-temperature plasma were investigated by using Raman spectroscopy. It was found that the decrease in the density of CO{sub 2} during plasma generation was less than 0.02 g/cm{sup 3} (critical density of CO{sub 2}:0.467 g/cm{sup 3}), when compared to the decrease in density of pure CO{sub 2} for a wide pressure range from gaseous to supercritical conditions. Moreover, it was experimentally verified that the density fluctuation observed near the critical point persists in the reaction field.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Plume Characterization of a Laboratory Model 22 N GPIM Thruster via High-Frequency Raman Spectroscopy

The Green Propellant Infusion Mission (GPIM) will demonstrate the capability of a green propulsion system, specifically, one using the monopropellant, AF-M315E. One of the risks identified for GPIM is potential contamination of sensitive areas of the spacecraft from the effluents in the plumes of AF-M315E thrusters. Plume characterization of a laboratory-model 22 N thruster via optical diagnostics was conducted at NASA GRC in a space-simulated environment. A high-frequency pulsed laser was coupled with an electron-multiplied ICCD camera to perform Raman spectroscopy in the near-field, low-pressure plume. The Raman data yielded plume constituents and temperatures over a range of thruster chamber pressures and as a function of thruster (catalyst) operating time. Schlieren images of the near-field plume enabled calculation of plume velocities and revealed general plume structure of the otherwise invisible plume. The measured velocities are compared to those predicted by a two-dimensional, kinetic model. Trends in data and numerical results are presented from catalyst mid-life to end-of-life. The results of this investigation were coupled with the Raman and Schlieren data to provide an anchor for plume impingement analysis presented in a companion paper. The results of both analyses will be used to improve understanding of the nature of AF-M315E plumes and their impacts to GPIM and other future missions.

Raman Spectroscopy↗

Surface-Enhanced Raman Spectroscopy Investigation of the Potential-Dependent Acid–Base Chemistry of Silver-Immobilized 2-Mercaptobenzoic Acid

The acid–base chemistry of 2-mercaptobenzoic acid (2-MBA) immobilized on a polycrystalline silver surface was investigated by surface-enhanced Raman spectroscopy under potential control. The COO – bending mode of the benzoate form and the C–COOH stretching mode of the benzoic acid form of 2-MBA were used to determine the relative deprotonated and protonated populations of the bound ligand, respectively. In addition, shifts in the symmetric carboxylate stretching mode of 2-MBA reveal interactions between the benzoate group and the silver surface, interactions which could be displaced by acetate and other buffer anions from solution. It was found that the applied potential has a significant effect on the proton dissociation equilibrium of immobilized 2-MBA. This effect arises from the surface potential governing the activity of protons at the interface, which changes the interfacial pH relative to bulk solution. The results are fit to a Poisson–Boltzmann model, corrected for potential distribution across the monolayer and interactions between adjacent immobilized ligands. Furthermore, the results show a significant increase in the intrinsic pK a of the immobilized ligand compared to 2-MBA in free solution, which is likely due to an increase in electron density on the benzoic acid group that occurs upon binding of the thiol group to the silver surface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-pressure Cr 3+ luminescence and Raman spectroscopy of a natural MgAl 2 O 4 spinel to ∼60 GPa

Cr 3+ luminescence and Raman spectroscopy of a natural spinel were collected up to ∼60 GPa at ambient temperature using a Ne or a 4:1 methanol-ethanol mixture as the pressure transmitting media. Here, in the Ne experiments above ∼40 GPa, and in the 4:1 methanol–ethanol experiments above ∼20 GPa, all luminescence emission lines shift non-linearly, and by 59 GPa the spectra are broadened and are significantly changed. The Raman modes shift smoothly to higher frequencies with pressure, with a slight change in slope above 40 GPa, with no kinks or discontinuities. By ∼60 GPa, only the most intense Eg mode remains resolvable, appearing broadened and reduced in intensity. The change in slope in the Raman modes and luminescence bands may be due to a change in the compression mechanism of spinel. When spinel was decompressed from 40 GPa all changes were fully reversible; however, when the samples were decompressed from 54 to 60 GPa in Ne and 59 GPa in 4:1 methanol-ethanol the spectra were irreversibly changed. The change in the luminescence spectra and the Raman spectra are likely due to a pressure induced disorder of the anions or partial amorphization between 40 and 60 GPa.

Cr3+↗

LIGHT INDUCED TELLURIUM ENRICHMENT ON CDZNTE CRYSTALSURFACES DETECTED BY RAMAN SPECTROSCOPY

Synthetic CdZnTe or 'CZT' crystals can be grown under controlled conditions to produce high quality crystals to be used as room temperature radiation detectors. Even the best crystal growth methods result in defects, such as tellurium secondary phases, that affect the crystal's performance. In this study, CZT crystals were analyzed by micro Raman spectroscopy. The growth of Te rich areas on the surface was induced by low powered lasers. The growth was observed versus time with low power Raman scattering and was observed immediately under higher power conditions. The detector response was also measured after induced Te enrichment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In situ high-temperature Raman spectroscopy for online EAF slag analysis

Real-time monitoring of slag chemistry is critical for optimizing Electric Arc Furnace (EAF) steelmaking operations, where dynamic variations in slag composition directly influence slag foaming, refractory degradation, and thermal efficiency. Conventional techniques such as X-ray fluorescence (XRF), Fourier-transform infrared (FTIR), and scanning electron microscopy coupled with energy-dispersive X-ray spectroscopy (SEM-EDS) are commonly used to analyze slag composition, but their offline nature and equipment constraints limit their applicability for online monitoring in harsh industrial environments. To address this challenge, we present an in situ, high-temperature analytical approach that integrates Raman spectroscopy with a custom designed fiber-optic probe for real-time slag characterization at 1550 °C. The system enables non destructive spectral acquisition from molten slags, providing molecular-level insights into silicate polymerization and iron oxidation states. Eight synthetic slag samples were evaluated, and key Raman features—such as Q n silicate units and FeO₄/FeO₆ coordination environments—were identified and quantitatively correlated with slag basicity and Fe₂O₃ content. The results demonstrate agreement between Raman spectral ratios and bulk slag chemistry, validating the method’s capability to track compositional and structural changes under molten temperature. This work establishes the feasibility of deploying fiber-optic Raman probe for online EAF slag monitoring and highlights their potential to support closed-loop control strategies, thereby enhancing process stability, refractory protection, and steel quality in industrial steelmaking applications.

47 OTHER INSTRUMENTATION↗

On the Combined Application of Raman Spectroscopy and Photoluminescence Spectroscopy for the Diagnostics of Multilayer Heterostructures

The results of studying GaInAs/GaInP/GaAs photodiode structures grown by metal–organic vapor-phase epitaxy are reported. A procedure for the diagnostics of such multilayer structures is developed. The procedure is based on the application of Raman spectroscopy in combination with photoluminescence spectroscopy in the mode of the lateral scanning of transverse cleavages. The compositions of the GaInAs and GaInP solid solutions are determined.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Light-Induced Tellurium Enrichment on CdZnTe Crystal Surfaces Detected by Raman Spectroscopy

CdZnTe (CZT) crystals can be grown under controlled conditions to produce high-quality crystals to be used as room-temperature radiation detectors. Even the best crystal growth methods result in defects, such as tellurium secondary phases, that affect the crystal's performance. In this study, CZT crystals were analyzed by micro-Raman spectroscopy. The growth of Te rich areas on the surface was induced by low-power lasers. The growth was observed versus time with low-power Raman scattering and was observed immediately under higher-power conditions. The detector response was also measured after induced Te enrichment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗