Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Raman”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

UV Resonant Raman Spectrometer with Multi-Line Laser Excitation

A Raman spectrometer employs two or more UV (ultraviolet) laser wavel engths to generate UV resonant Raman (UVRR) spectra in organic sampl es. Resonant Raman scattering results when the laser excitation is n ear an electronic transition of a molecule, and the enhancement of R aman signals can be several orders of magnitude. In addition, the Ra man cross-section is inversely proportional to the fourth power of t he wavelength, so the UV Raman emission is increased by another fact or of 16, or greater, over visible Raman emissions. The Raman-scatter ed light is collected using a high-resolution broadband spectrograph . Further suppression of the Rayleigh-scattered laser light is provi ded by custom UV notch filters.

Lambert, James L.↗

Correction Technique for Raman Water Vapor Lidar Signal-Dependent Bias and Suitability for Water Wapor Trend Monitoring in the Upper Troposphere

The MOHAVE-2009 campaign brought together diverse instrumentation for measuring atmospheric water vapor. We report on the participation of the ALVICE (Atmospheric Laboratory for Validation, Interagency Collaboration and Education) mobile laboratory in the MOHAVE-2009 campaign. In appendices we also report on the performance of the corrected Vaisala RS92 radiosonde measurements during the campaign, on a new radiosonde based calibration algorithm that reduces the influence of atmospheric variability on the derived calibration constant, and on other results of the ALVICE deployment. The MOHAVE-2009 campaign permitted the Raman lidar systems participating to discover and address measurement biases in the upper troposphere and lower stratosphere. The ALVICE lidar system was found to possess a wet bias which was attributed to fluorescence of insect material that was deposited on the telescope early in the mission. Other sources of wet biases are discussed and data from other Raman lidar systems are investigated, revealing that wet biases in upper tropospheric (UT) and lower stratospheric (LS) water vapor measurements appear to be quite common in Raman lidar systems. Lower stratospheric climatology of water vapor is investigated both as a means to check for the existence of these wet biases in Raman lidar data and as a source of correction for the bias. A correction technique is derived and applied to the ALVICE lidar water vapor profiles. Good agreement is found between corrected ALVICE lidar measurments and those of RS92, frost point hygrometer and total column water. The correction is offered as a general method to both quality control Raman water vapor lidar data and to correct those data that have signal-dependent bias. The influence of the correction is shown to be small at regions in the upper troposphere where recent work indicates detection of trends in atmospheric water vapor may be most robust. The correction shown here holds promise for permitting useful upper tropospheric water vapor profiles to be consistently measured by Raman lidar within NDACC (Network for the Detection of Atmospheric Composition Change) and elsewhere, despite the prevalence of instrumental and atmospheric effects that can contaminate the very low signal to noise measurements in the UT.

MOHAVE-2009↗

Benefits of using multiple Raman laser wavelengths for characterizing defects in a UO 2 matrix

Abstract Raman spectroscopy is one of the most useful techniques for studying the structure of UO 2 and changes due to specific defects caused by doping, changes in stoichiometry, irradiation, or heating under oxidizing conditions. In this paper, we illustrate several aspects of the application of Raman techniques to the study of UO 2 , including the use of wavelength‐dependent excitation (455, 532, and 785 nm) to assess the effects of doping (Nd, Th, and Zr), ion irradiation, and in situ heating and oxidation (UO 2 to U 3 O 8 ). Additionally, we show examples of how correlative microscopy is possible using electron backscatter diffraction combined with Raman maps of specific vibration bands or of laser‐induced luminescence generated by rare‐earth dopants in the matrix. For each of these applications, we suggest optimal excitation wavelengths that vary depending on the desired data. Blue (455 nm) excitation tends to promote oxidation even at low powers, but because Raman spectra change little with doping, irradiation‐induced changes are easier to observe. Green (532 nm) excitation is optimal for observing electron–phonon resonance effects in UO 2 and offers a good compromise for high‐temperature oxidation experiments, delivering high‐quality spectra for both UO 2 and U 3 O 8 . Infrared (785 nm) excitation is best for observing “defect” bands associated with doping in UO 2 , as changes with irradiation are small. Raman spectroscopy is particularly suited for studying the stability of UO 2 towards oxidation in the presence of dopants simulating fission products, where electron–phonon resonant effects, dopant ion luminescence, and mapping can be used together to investigate structural rearrangement as a function of temperature. These techniques can offer insight into microstructural changes in UO 2 fuels at higher burnups envisioned in future reactors.

42 ENGINEERING↗

Raman and structural characterization of LuAlO{sub 3}

The structural and vibrational properties of lutetium orthoaluminate perovskite (LuAlO{sub 3}) were investigated by means of Raman spectroscopy and EXAFS measurements. The analysis of Raman spectra taken in four different polarized configurations along the principal axes at 20 K and room temperature conditions permits to assign the principal vibrational modes in LuAP single crystals and to confirm the belonging to the D{sub 2h}{sup 16} space group. EXAFS measurements were performed at room temperature in order to obtain local structural informations on the first and next nearest neighbors around lutetium absorptions sites. Unit cell parameters and bond lengths were determined by the analysis of the EXAFS spectroscopy at the L{sub 3} absorption edge of lutetium. The informations thus gathered on this compound can offer a useful addition in the framework of a full structural characterization of LuAlO{sub 3}. - Graphical abstract: Raman active mode in LuAP crystal. Highlights: > Structural characterization of LuAlO{sub 3} is obtained by Raman and EXAFS spectroscopies. > Vibrational modes, temperature-dependent variations studied by Raman spectroscopy. > Cell parameters and local characterization obtained by EXAFS spectroscopy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simultaneous presence of (Si{sub 3}O{sub 10}){sup 8−} and (Si{sub 2}O{sub 7}){sup 6−} groups in new synthetic mixed sorosilicates: BaY{sub 4}(Si{sub 2}O{sub 7})(Si{sub 3}O{sub 10}) and isotypic compounds, studied by single-crystal X-ray diffraction, Raman spectroscopy and DFT calculations

Three new, isotypic silicate compounds, BaY{sub 4}(Si{sub 2}O{sub 7})(Si{sub 3}O{sub 10}), SrYb{sub 4}(Si{sub 2}O{sub 7})(Si{sub 3}O{sub 10}) and SrSc{sub 4}(Si{sub 2}O{sub 7})(Si{sub 3}O{sub 10}), were synthesized using high-temperature flux growth techniques, and their crystal structures were solved from single-crystal X-ray intensity data: monoclinic, P2{sub 1}/m, with a=5.532(1)/5.469(1)/5.278(1), b=19.734(4)/19.447(4)/19.221(4), c=6.868(1)/6.785(1)/6.562(1) Å, β=106.53(3)/106.20(3)/106.50(3)°, V=718.8(2)/693.0(2)/638.3(2) Å{sup 3}, R(F)=0.0225/0.0204/0.0270, respectively. The topology of the novel structure type contains isolated horseshoe-shaped Si{sub 3}O{sub 10} groups (Si–Si–Si=93.15–95.98°), Si{sub 2}O{sub 7} groups (Si–O{sub bridge}–Si=180°, symmetry-restricted) and edge-sharing M(1)O{sub 6} and M(2)O{sub 6} octahedra. Single-crystal Raman spectra of the title compounds were measured and compared with Raman spectroscopic data of chemically and topologically related disilicates and trisilicates, including BaY{sub 2}(Si{sub 3}O{sub 10}) and SrY{sub 2}(Si{sub 3}O{sub 10}). The band assignments are supported by additional theoretical calculation of Raman vibrations by DFT methods. - Graphical abstract: View of BaY{sub 4}(Si{sub 2}O{sub 7})(Si{sub 3}O{sub 10}) along [100], showing zigzag chains and the tri- and disilicate groups. The unit cell is outlined. Display Omitted - Highlights: • We report a novel interesting crystal structure type for mixed sorosilicates containing Y, Yb, and Sc. • Synthesis of such mixed sorosilicates is possible by a high-temperature flux-growth technique. • Calculation of Raman vibrations by advanced DFT methods allows a considerably improved interpretation of measured Raman spectra.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Relationship between ferroelectric properties and local structure of Pb{sub 1−x}Ba{sub x}Zr{sub 0.40}Ti{sub 0.60}O{sub 3} ceramic materials studied by X-ray absorption and Raman spectroscopies

This paper reports on the structural characterization of Pb{sub 1−x}Ba{sub x}Zr{sub 0.40}Ti{sub 0.60}O{sub 3} (PBZT) ferroelectric ceramic compositions prepared by the conventional solid state reaction method. X-ray absorption spectroscopy (XAS) and Raman spectroscopy were used in the probing of the local structure of PBZT samples that exhibit a normal or relaxor ferroelectric behavior. They showed a considerable local disorder around Zr and Pb atoms in the samples of tetragonal or cubic long-range order symmetry. The intensity of the E(TO{sub 3}) mode in the Raman spectra of PBZT relaxor samples remains constant at temperatures lower than T{sub m}, which has proven the stabilization of the correlation process between nanodomains. - Graphical abstract: X-ray absorption measurements showed considerable local disorder around Zr and Pb atoms in the samples of tetragonal or cubic long-range order symmetry. The intensity of the E(TO{sub 3}) mode in the Raman spectra of PBZT relaxor samples remains constant at temperatures lower than T{sub m}, which has proven the stabilization of the correlation process between nanodomains. Display Omitted - Highlights: • Structural characterization of Pb{sub 1−x}Ba{sub x}Zr{sub 0.40}Ti{sub 0.60}O{sub 3} (PBZT) ferroelectric ceramic. • X-ray absorption and Raman spectroscopies were used to probe the structure of PBZT. • Dissymmetry of Zr and Pb sites was observed in samples long-range cubic symmetry. • Local disorder in all PBZT samples through the observation of Raman active modes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Bifacial Raman Enhancement on Monolayer Two-Dimensional Materials

Understanding the charge interaction between molecules and two-dimensional (2D) materials is essential for the design of functional devices. Here, we report the bifacial Raman enhancement of molecules on monolayer graphene and hexagonal boron nitride (h-BN). Taking advantage of the atomically thick layered structure, we show that both surfaces of 2D materials can interact with molecules and simultaneously enhance their Raman scattering. Different enhancement features were observed for monolayer graphene and h -BN. The intensity decrease of particular Raman modes of copper phthalocyanine (CuPc) on both surfaces of h -BN suggests that z -dipoles exist and are partially canceled out between the two interfaces, while the twice Raman intensities of the characteristic Raman modes of CuPc on both surfaces of graphene compared to that on one surface evidenced the charge transfer process. Furthermore, these results provide an approach to modify 2D materials by bifacial adsorption of molecules, and the findings can inspire the design of functional 2D material-based devices.

36 MATERIALS SCIENCE↗

Raman Spectroscopy: A New Proposal for the Detection of Leukemia Using Blood Samples

The use of Raman spectroscopy to analyze blood biochemistry and hence distinguish between normal and abnormal blood was investigated. The blood samples were obtained from 6 patients who were clinically diagnosed with leukemia and 6 healthy volunteer. The imprint was put under the microscope and several points were chosen for Raman measurement. All spectra were collected at confocal Raman micro-spectroscopy (Renishaw) with NIR 830 nm laser. It is shown that the serum samples from patients with leukemia and from the control group can be discriminated when the multivariate statistical methods of principal component analysis (PCA) and linear discriminated analysis (LDA) is applied to their Raman spectra. The ratios of some band intensities were analyzed and some band ratios were significant and corresponded to proteins, phospholipids, and polysaccharides. In addition, currently the degree of damage to the bone marrow is estimated through biopsies and therefore it is a very procedure painful. The preliminary results suggest that Raman spectroscopy could be a new technique to study the bone marrow using just blood samples.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Absolute calibration of LIDAR Thomson scattering systems by rotational Raman scattering

Absolute calibration of LIDAR Thomson scattering systems on large fusion devices may be achieved using rotational Raman scattering. The choice of calibrating gas molecule presents different options and design trade-offs and is likely to be strongly dependent on the laser wavelength selected. Raman scattering of hydrogenic molecules produces a very broad spectrum, however, with far fewer scattered photons than scattering from nitrogen or oxygen at the same gas pressure. Lower laser wavelengths have the advantage that the Raman cross section increases, {sigma}{sub Raman}{proportional_to}1/{lambda}{sub 0}{sup 4}, but the disadvantage that the spectral width of the scattered spectrum decreases, {Delta}{lambda}{sub Raman}{proportional_to}{lambda}{sub 0}{sup 2}. This narrower spectrum makes measurement closer to the laser wavelength necessary. The design of the calibration technique presents a number of challenges. Some of these challenges are generic to all Thomson scattering systems. These include detecting a sufficient number of photoelectrons and designing filters that measure close to the laser wavelength while simultaneously achieving adequate blocking of the laser wavelength. An issue specific to LIDAR systems arises since the collection optics operates over a wide range of depth of field. This wide depth of field has the effect of changing the angle of light incident on the optical interference filter with plasma major radius. The angular distribution then determines the effective spectral transmission function of the interference filter and hence impacts on the accuracy of the absolute calibration. One method that can be used to increase absolute calibration accuracy is collecting both Stokes and anti-Stokes lines with optical filter transmission bands specifically designed to reduce systematic uncertainty.

43 PARTICLE ACCELERATORS↗

Polarization Raman spectroscopy of GaN nanorod bundles

We performed polarization Raman spectroscopy on single wurtzite GaN nanorod bundles grown by plasma-assisted molecular beam epitaxy. The obtained Raman spectra were compared with those of GaN epilayer. The spectral difference between the GaN nanorod bundles and epilayer reveals the relaxation of Raman selection rules in these GaN nanorod bundles. The deviation of polarization-dependent Raman spectroscopy from the prediction of Raman selection rules is attributed to both the orientation of the crystal axis with respect to the polarization vectors of incident and scattered light and the structural defects in the merging boundary of GaN nanorods. The presence of high defect density induced by local strain at the merging boundary was further confirmed by transmission electron microscopy. The averaged defect interspacing was estimated to be around 3 nm based on the spatial correlation model.

36 MATERIALS SCIENCE↗

Note: Deep ultraviolet Raman spectrograph with the laser excitation line down to 177.3 nm and its application

Deep UV Raman spectrograph with the laser excitation line down to 177.3 nm was developed in this laboratory. An ellipsoidal mirror and a dispersed-subtractive triple monochromator were used to collect and disperse Raman light, respectively. The triple monochromator was arranged in a triangular configuration with only six mirrors used. 177.3 nm laser excited Raman spectrum with cut-off wavenumber down to 200 cm{sup −1} and spectral resolution of 8.0 cm{sup −1} can be obtained under the condition of high purity N{sub 2} purging. With the C–C σ bond in Teflon selectively excited by the 177.3 nm laser, resonance Raman spectrum of Teflon with good quality was recorded on the home-built instrument and the σ-σ{sup *} transition of C–C bond was studied. The result demonstrates that deep UV Raman spectrograph is powerful for studying the systems with electronic transition located in the deep UV region.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determining the crystalline degree of silicon nanoclusters/SiO{sub 2} multilayers by Raman scattering

We use Raman scattering to investigate the size distribution, built-in strains and the crystalline degree of Si-nanoclusters (Si-nc) in high-quality Si-rich oxynitride/SiO{sub 2} multilayered samples obtained by plasma enhanced chemical vapor deposition and subsequent annealing at 1150 °C. An initial structural characterization of the samples was performed by means of energy-filtered transmission electron microscopy (EFTEM) and X-ray diffraction (XRD) to obtain information about the cluster size and the presence of significant amounts of crystalline phase. The contributions to the Raman spectra from crystalline and amorphous Si were analyzed by using a phonon confinement model that includes the Si-nc size distribution, the influence of the matrix compressive stress on the clusters, and the presence of amorphous Si domains. Our lineshape analysis confirms the existence of silicon precipitates in crystalline state, in good agreement with XRD results, and provides also information about the presence of a large compressive stress over the Si-nc induced by the SiO{sub 2} matrix. By using the Raman spectra from low temperature annealed samples (i.e., before the crystallization of the Si-nc), the relative scattering cross-section between crystalline and amorphous Si was evaluated as a function of the crystalline Si size. Taking into account this parameter and the integrated intensities for each phase as extracted from the Raman spectra, we were able to evaluate the degree of crystallization of the precipitated Si-nc. Our data suggest that all samples exhibit high crystalline fractions, with values up to 89% for the biggest Si-nc. The Raman study, supported by the EFTEM characterization, indicates that this system undergoes a practically abrupt phase separation, in which the precipitated Si-nanoclusters are formed by a crystalline inner part surrounded by a thin amorphous shell of approximately 1–2 atomic layers.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Multidimensional resonance raman spectroscopy by six-wave mixing in the deep UV

Two-dimensional (2D) resonance Raman spectroscopies hold great potential for uncovering photoinduced relaxation processes in molecules but are not yet widely applied because of technical challenges. Here, we describe a newly developed 2D resonance Raman experiment operational at the third-harmonic of a Titanium-Sapphire laser. High-sensitivity and rapid data acquisition are achieved by combining spectral interferometry with a background-free (six-pulse) laser beam geometry. The third-harmonic laser pulses are generated in a filament produced by the fundamental and second-harmonic pulses in neon gas at pressures up to 35 atm. The capabilities of the setup are demonstrated by probing ground-state wavepacket motions in triiodide. The information provided by the experiment is explored with two different representations of the signal. In one representation, Fourier transforms are carried out with respect to the two experimentally controlled delay times to obtain a 2D Raman spectrum. Further insights are derived in a second representation by dispersing the signal pulse in a spectrometer. It is shown that, as in traditional pump-probe experiments, the six-wave mixing signal spectrum encodes the wavepacket's position by way of the (time-evolving) emission frequency. Anharmonicity additionally induces dynamics in the vibrational resonance frequency. In all cases, the experimental signals are compared to model calculations based on a cumulant expansion approach. This study suggests that multi-dimensional resonance Raman spectroscopies conducted on systems with Franck-Condon active modes are fairly immune to many of the technical issues that challenge off-resonant 2D Raman spectroscopies (e.g., third-order cascades) and photon-echo experiments in the deep UV (e.g., coherence spikes). The development of higher-order nonlinear spectroscopies operational in the deep UV is motivated by studies of biological systems and elementary organic photochemistries.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Anomalous junctions characterized by Raman spectroscopy in Si{sub x}Ge{sub 1−x} nanowires with axially degraded components

The characterization of junctions in nanowires by high-resolution transmission electron microscopy with spherical aberration correction is tricky and tedious. Many disadvantages also exist, including rigorous sample preparation and structural damage inflicted by high-energy electrons. In this work, we present a simple, low-cost, and non-destructive Raman spectroscopy method of characterizing anomalous junctions in nanowires with axially degraded components. The Raman spectra of Si{sub x}Ge{sub 1−x} nanowires with axially degraded components are studied in detail using a confocal micro-Raman spectrometer. Three Raman peaks (ν{sub Si–Si} = 490 cm{sup −1}, ν{sub Si–Ge} = 400 cm{sup −1}, and ν{sub Ge–Ge} = 284 cm{sup −1}) up-shift with increased Si content. This up-shift originates in the bond compression induced by a confined effect on the radial direction of nanowire. The anomalous junctions in Si{sub x}Ge{sub 1−x} nanowires with axially degraded components are then observed by Raman spectroscopy and verified by transmission electron microscopy energy-dispersive X-ray spectroscopy. The anomalous junctions of Si{sub x}Ge{sub 1−x} nanowires with axially degraded components are due to the vortex flow of inlet SiH{sub 4} and GeH{sub 4} gas in their synthesis. The anomalous junctions can be used as raw materials for fabricating devices with special functions.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Contributed Review: Experimental characterization of inverse piezoelectric strain in GaN HEMTs via micro-Raman spectroscopy

Micro-Raman thermography is one of the most popular techniques for measuring local temperature rise in gallium nitride (GaN) high electron mobility transistors with high spatial and temporal resolution. However, accurate temperature measurements based on changes in the Stokes peak positions of the GaN epitaxial layers require properly accounting for the stress and/or strain induced by the inverse piezoelectric effect. It is common practice to use the pinched OFF state as the unpowered reference for temperature measurements because the vertical electric field in the GaN buffer that induces inverse piezoelectric stress/strain is relatively independent of the gate bias. Although this approach has yielded temperature measurements that agree with those derived from the Stokes/anti-Stokes ratio and thermal models, there has been significant difficulty in quantifying the mechanical state of the GaN buffer in the pinched OFF state from changes in the Raman spectra. In this paper, we review the experimental technique of micro-Raman thermography and derive expressions for the detailed dependence of the Raman peak positions on strain, stress, and electric field components in wurtzite GaN. We also use a combination of semiconductor device modeling and electro-mechanical modeling to predict the stress and strain induced by the inverse piezoelectric effect. Based on the insights gained from our electro-mechanical model and the best values of material properties in the literature, we analyze changes in the E{sub 2} high and A{sub 1} (LO) Raman peaks and demonstrate that there are major quantitative discrepancies between measured and modeled values of inverse piezoelectric stress and strain. We examine many of the hypotheses offered in the literature for these discrepancies but conclude that none of them satisfactorily resolves these discrepancies. Further research is needed to determine whether the electric field components could be affecting the phonon frequencies apart from the inverse piezoelectric effect in wurtzite GaN, which has been predicted theoretically in zinc blende gallium arsenide (GaAs).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spin transitions in La{sub 0.7} Ba{sub 0.3}CoO{sub 3} thin films revealed by combining Raman spectroscopy and X-ray diffraction

In cobaltite, the spin states transitions of Co{sup 3+/4+} ions govern the magnetic and electronic conduction properties. These transitions are strain-sensitive and can be varied using external parameters, including temperature, hydrostatic pressure, or chemical stresses through ionic substitutions. In this work, using temperature dependent Raman spectroscopy and X-ray diffraction, the epitaxial strain effects on both structural and vibrational properties of La{sub 0.7} Ba{sub 0.3} CoO{sub 3} (LBCO) cobaltite thin films are investigated. All Raman active phonon modes as well as the structure are found to be strongly affected. Both Raman modes and lattice parameter evolutions show temperature changes correlated with magnetic and electronic transitions properties. Combining Raman spectroscopy and X-ray diffraction appears as a powerful approach to probe the spin transition in thin film cobaltite. Our results provide insight into strong spin-charge-phonon coupling in LBCO thin film. This coupling manifests as vibrational transition with temperature in the Raman spectra near the ferromagnetic spin ordered transition at 220 K.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Raman spectroscopy of CaIrO[subscript 3] postperovskite up to 30 GPa

We have measured Raman spectra of the postperovskite (PPv) phase in CaIrO{sub 3} up to 30 GPa to constrain the Grueneisen parameter ({gamma}). We identified a total of 4 strong modes between 200 and 650 cm{sup -1}, which is in contrast with the Raman spectra of Mn{sub 2}O{sub 3} and MgGeO{sub 3}-PPv where at least nine different modes have been detected. We found no sign of a phase transition in the Raman spectra of PPv CaIrO{sub 3}, which supports the stability of the PPv phase up to 30 GPa and room temperature in CaIrO{sub 3}. the spectroscopic Grueneisen parameter, {gamma}{sub sp,0} = 1.66--1.72, constrained from our Raman data, is in excellent agreement with the thermodynamic Grueneisen parameter, {gamma}{sub th,0} = 1.75 {+-} 0.05, calculated from recent XRD measurements (Martin et al. 2007) on CaIrO{sub 3}-PPv synthesized at high pressure and temperature similar to our starting material. Our result suggests that {gamma}{sub sp} constrained by Raman measurements provides a reasonable estimate on the {gamma}{sub th} of the PPv phase in CaIrO{sub 3}.

58 GEOSCIENCES↗

Enhanced Uranium Ore Concentrate Analysis by Handheld Raman Sensor: FY15 Status Report

High-purity uranium ore concentrates (UOC) represent a potential proliferation concern. A cost-effective, “point and shoot” in-field analysis capability to identify ore types, phases of materials present, and impurities, as well as estimate the overall purity would be prudent. Handheld, Raman-based sensor systems are capable of identifying chemical properties of liquid and solid materials. While handheld Raman systems have been extensively applied to many other applications, they have not been broadly studied for application to UOC, nor have they been optimized for this class of chemical compounds. PNNL was tasked in Fiscal Year 2015 by the Office of International Safeguards (NA-241) to explore the use of Raman for UOC analysis and characterization. This report summarizes the activities in FY15 related to this project. The following tasks were included: creation of an expanded library of Raman spectra of a UOC sample set, creation of optimal chemometric analysis methods to classify UOC samples by their type and level of impurities, and exploration of the various Raman wavelengths to identify the ideal instrument settings for UOC sample interrogation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗