Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Real-time measurements of temperature, pressure and moisture profiles in High-Performance Concrete exposed to high temperatures during neutron radiography imaging

High-Performance Concrete (HPC) is particularly prone to explosive spalling when exposed to high temperature. Although the exact causes that lead to spalling are still being debated, moisture transport during heating plays an important role in all proposed mechanisms. In this study, slabs made of high-performance, low water-to-binder ratio mortars with addition of superabsorbent polymers (SAP) and polypropylene fibers (PP) were heated from one side on a temperature-controlled plate up to 550 °C. A combination of measurements was performed simultaneously on the same sample: moisture profiles via neutron radiography, temperature profiles with embedded thermocouples and pore pressure evolution with embedded pressure sensors. Spalling occurred in the sample with SAP, where sharp profiles of moisture and temperature were observed. No spalling occurred when PP-fibers were introduced in addition to SAP. The experimental procedure described here is essential for developing and verifying numerical models and studying measures against fire spalling risk in HPC.

42 ENGINEERING↗

Sorption kinetics of superabsorbent polymers (SAPs) in fresh Portland cement-based pastes visualized and quantified by neutron radiography and correlated to the progress of cement hydration

Water sorption of two superabsorbent polymers in cement-based pastes has been characterized by neutron radiography. Cement pastes with W/C of 0.25 and 0.50 and one additionally containing silica fume (W/C = 0.42) were investigated. The SAPs differed in their inherent sorption kinetics in extracted cement pore solution (SAP 1: self-releasing; SAP 2: retentive). Desorption from SAP 1 started very early after paste preparation. Hence, its individual non-retentiveness governs its behavior only. SAP 2 released water into all matrices, but its kinetics were different. In the paste with the highest W/C, some moderate water release was recorded from the beginning. In the other two pastes, SAP 2 retained its stored liquid during the dormant period, i.e., up to the percolation threshold. Intense desorption then set in and continued throughout the acceleration period. These findings explain the pronouncedly higher efficiency of SAP 2 as internal curing admixture as compared to SAP 1.

36 MATERIALS SCIENCE↗

Water penetration through cracks in self-healing cementitious materials with superabsorbent polymers studied by neutron radiography

SuperAbsorbent Polymers (SAPs) are a promising admixture to obtain self-sealing and self-healing cementitious materials. They are able to physically block water penetration through cracks due to their swelling ability. This is very useful in a cementitious material which is prone to cracking leading to a reduced durability. The effectiveness of counteracting water penetration is of concern. Neutron radiography was performed in order to investigate the influence of SAPs on the water permeability through healed cracks with respect to a reference material without SAPs. The gravimetrically measured capillary absorption corresponded with the obtained results after image analysis and a quantitative analysis could be made. SAPs enhance the water impermeability and are able to seal and heal a crack effectively up to 100 μm. The healing was a main factor to impede water movement through cracks. This will lead to less water ingress in building infrastructures and a possible longer service life.

36 MATERIALS SCIENCE↗

Monitoring steel fibre orientation in self-compacting cementitious composite slabs during pouring with dynamic X-ray radiography

This paper presents a new technique based on dynamic X-ray radiography that can be used to assess fibre orientation during pouring of steel fibre reinforced cementitious composites. Synthetic examples were used to assess the suitability and robustness of the technique, which was shown to provide reliable measurements of fibre orientation even when the signal-to-noise ratio is relatively high. A study was then carried out on the effect of formwork aspect ratio, time/duration of pouring, and rebar placement on the fibre orientation while pouring self-compacting cementitious composite slabs. Results demonstrated the ability of the technique in monitoring the movements of fibres while pouring, and the strong effect of the flow in inducing preferential fibre alignment within the slabs. Fibre orientation was found to vary progressively over time and could take about half of the duration of pouring to fully stabilise.

36 MATERIALS SCIENCE↗

An experimental investigation of gas fuel injection with X-ray radiography

In this paper, an outward-opening compressed natural gas, direct injection fuel injector has been studied with single-shot x-ray radiography. Three dimensional simulations have also been performed to compliment the x-ray data. Argon was used as a surrogate gas for experimental and safety reasons. This technique allows the acquisition of a quantitative mapping of the ensemble-average and standard deviation of the projected density throughout the injection event. Two dimensional, ensemble average and standard deviation data are presented to investigate the quasi-steady-state behavior of the jet. Upstream of the stagnation zone, minimal shot-to-shot variation is observed. Downstream of the stagnation zone, bulk mixing is observed as the jet transitions to a subsonic turbulent jet. From the time averaged data, individual slices at all downstream locations are extracted and an Abel inversion was performed to compute the radial density distribution, which was interpolated to create three dimensional visualizations. The Abel reconstructions reveal that upstream of the stagnation zone, the gas forms an annulus with high argon density and large density gradients. Inside this annulus, a recirculation region with low argon density exists. Downstream, the jet transitions to a fully turbulent jet with Gaussian argon density distributions. This experimental data is intended to serve as a quantitative benchmark for simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhancement of high energy X-ray radiography using compound parabolic concentrator targets

We report an increase in MeV energy bremsstrahlung x-ray production using compound parabolic concentrators (CPC) compared to flat solid targets during relativistic laser-plasma experiments on a 140 J, 150 fs laser system using an f/40 focusing optic. CPC enhanced targets show a > 3x increase in high energy x-ray production over planar foil targets. Furthermore, this enhancement in x-ray energy spectra shows a direct improvement in the radiography of an image quality indicator (IQI) object with a 20 g/cm 2 areal density.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparison of Combined X-Ray Radiography and Magnetic Resonance (XMR) Imaging-Versus Computed Tomography-Based Dosimetry for the Evaluation of Permanent Prostate Brachytherapy Implants

Purpose: To present a method for the dosimetric analysis of permanent prostate brachytherapy implants using a combination of stereoscopic X-ray radiography and magnetic resonance (MR) imaging (XMR) in an XMR facility, and to compare the clinical results between XMR- and computed tomography (CT)-based dosimetry. Methods and Materials: Patients who had received nonstranded iodine-125 permanent prostate brachytherapy implants underwent XMR and CT imaging 4 weeks later. Four observers outlined the prostate gland on both sets of images. Dose-volume histograms (DVHs) were derived, and agreement was compared among the observers and between the modalities. Results: A total of 30 patients were evaluated. Inherent XMR registration based on prior calibration and optical tracking required a further automatic seed registration step that revealed a median root mean square registration error of 4.2 mm (range, 1.6-11.4). The observers agreed significantly more closely on prostate base and apex positions as well as outlining contours on the MR images than on those from CT. Coefficients of variation were significantly higher for observed prostate volumes, D90, and V100 parameters on CT-based dosimetry as opposed to XMR. The XMR-based dosimetry showed little agreement with that from CT for all observers, with D90 95% limits of agreement ranges of 65, 118, 79, and 73 Gy for Observers 1, 2, 3, and 4, respectively. Conclusions: The study results showed that XMR-based dosimetry offers an alternative to other imaging modalities and registration methods with the advantages of MR-based prostate delineation and confident three-dimensional reconstruction of the implant. The XMR-derived dose-volume histograms differ from the CT-derived values and demonstrate less interobserver variability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessing Transgender-Related Content in Radiography Programs in the United States: A Survey of Educators

Imaging science technologists care for diverse populations of individuals and need to be adequately prepared to provide optimal patient care that reduces any potential disparities among these individuals. In particular, exposure to transgender individuals is increasing in today's society. The purpose of this research study was to examine the extent to which transgender-related content is taught in radiography programs in the United States by surveying educators to assess their knowledge of, experience with, and readiness to teach such content.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Microstructural evolution and growth behavior of intermetallic compounds at the liquid Al/solid Fe interface by synchrotron X-ray radiography

Highlights: • A layered and tongue-like η phase was in-situ observed by synchrotron radiation X-ray radiography. • The coalescence of η phase bottom resulted in dissolution, further increasing the growth rate. • The θ phase growth behavior with different morphologies during cooling was analyzed. - Abstract: The growth of Inter-Metallic Compounds (IMCs) with dissolution was investigated on the liquid Al/solid Fe interconnection by using synchrotron radiation real-time imaging technology. At the initial stage of holding at 850 °C, a layer of the η-Fe{sub 2}Al{sub 5} phase formed at the interface, and tongue-like η grew into α-Fe. The tongue-like η phase had a stronger (001) texture than the layered phase. The coalescence of tongue-like η started at the bottom, followed by the dissolution of IMCs, which leads to a further increase in its growth rate. During solidification stage, the dotted, needle-like and flake θ-FeAl{sub 3} phases were sequentially formed.

36 MATERIALS SCIENCE↗

Ultra-high speed burst-mode imager for multi-frame radiography

A 720 x 720 pixel hybrid-CMOS imager was fabricated by Rockwell Scientific (now Teledyne Imaging Sensors). Several cameras have been in operation for 5 years, in a variety of static and dynamic experiments, at the 800MeV proton radiography (pRAD) facility at the LANSCE accelerator. The cameras can operate with a per-pulse adjustable inter-frame time of 250ns to 2s, and with an exposure/integration-time as short as 150 ns. Given the 800 ms total readout time, the imager can be externally synchronized to 0.1-to-5Hz, 50-ns wide proton beam pulses, and record 1000-frame radiographic movies of 5-to-30 minute duration. The effectiveness and dependence of the global electronic shutter on the pixelated Si photo-sensor bias voltage is discussed. The spatial resolution dependence of the full imaging system on various monolithic and structured scintillators is presented. We also present features of a new-generation 10-frame, 1024 x 1024 pixel, 50-ns exposure, 12-bit dynamic range imager, which is now in the design phase.

47 OTHER INSTRUMENTATION↗

In situ measurement of interfacial tension of Fe-S and Fe-P liquids under high pressure using X-ray radiography and tomography techniques

Interfacial tension is one of the most important properties of the liquid iron alloy that controls the core formation process in the early history of the Earth and planets. In this study, we made high-pressure X-ray radiography and micro-tomography measurements to determine the interfacial tension between liquid iron alloys and silicate melt using the sessile drop method. The measured interfacial tension of liquid Fe-S decreased significantly (802-112 mN/m) with increasing sulphur content (0-40 at%) at 1.5 GPa. In contrast, the phosphorus content of Fe had an almost negligible effect on the interfacial tension of liquid iron. These tendencies in the effects of light elements are consistent with those measured at ambient pressure. Our results suggest that the effect of sulphur content on the interfacial tension of liquid Fe-S (690 mN/m reduction with the addition of 40 at% S) is large compared with the effect of temperature (~273 mN/m reduction with an increase of 200 K). The three-dimensional structure of liquid Fe-S was obtained at ~2 GPa and 1373-1873 K with a high-pressure tomography technique. The Fe-S droplet was quite homogeneous when evaluated in a slice of the three-dimensional image.

36 MATERIALS SCIENCE↗

Radiography of Chaotically Moving Objects

Radiography of moving objects is an advanced problem when the dynamic range of acquired radiograms is restricted by a limited exposition time. Exposition time has to be short to avoid image blurring due to object moving. It is possible to increase the dynamic range by summing short time radiograms set when the periodical object movement is presented as in the case of heart beating for instance. On the other hand a non periodical movement can be studied using tools of X-ray Digital Image Correlation technique. Short time radiograms are fitted into corresponding positions and consequently summed for higher data statistics as it is presented in this work.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Imaging and Radiography with Nuclear Resonance Fluorescence and Effective-Z (EZ-3D) Determination; SNM Detection Using Prompt Neutrons from Photon Induced Fission

Four new technologies have been developed for use in non-intrusive inspection systems to detect nuclear materials, explosives and contraband. Nuclear Resonance Fluorescence (NRF) provides a three dimensional image of the isotopic content of a container. NRF determines the isotopic composition of a region and specifies the isotopic structure of the neighboring regions, thus providing the detailed isotopic composition of any threat. In transmission mode, NRF provides a two dimensional projection of the isotopic content of a container, much as standard X-ray radiography provides for density. The effective-Z method (EZ-3D) uses electromagnetic scattering processes to yield a three-dimensional map of the effective-Z and the density in a container. The EZ-3D method allows for a rapid discrimination based on effective Z and mass of materials such as those with high Z, as well as specifying regions of interest for other contraband. The energy spectrum of prompt neutrons from photon induced fission (PNPF) provides a unique identification of the presence of actinides and SNM. These four new technologies can be used independently or together to automatically determine the presence of hazardous materials or contraband. They can also be combined with other technologies to provide added specificity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Note: X-ray radiography for measuring chemical diffusion in metallic melts

A x-ray radioscopy technique for measuring in situ chemical diffusion coefficients in metallic melts is presented. The long-capillary diffusion measurement method is combined with imaging techniques using microfocus tubes and flat panel detectors in order to visualize and quantitatively analyze diffusive mixing of two melts of different chemical composition. The interdiffusion coefficient as function of temperature and time is obtained by applying Fick's diffusion laws. Tracking the time dependence of the mean square penetration depth of the mixing process allows to detect changes in the mass transport caused by convective flow. The possibility to sort out convective mass transport contributions from analysis enhances significantly the accuracy compared to the conventional long-capillary diffusion measurement method with postmortem analysis. The performance of this novel diffusion measurement method with x-ray radiography technique is demonstrated by a diffusion experiment in an Al-Ni melt.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An evaluation of high energy bremsstrahlung background in point-projection x-ray radiography experiments

Backlit pinhole x-ray radiography has provided high-resolution images in many recent high-energy-density laser experiments. Its aim is to image the object of interest with a roughly monochromatic K{alpha} source. However, despite the high intrinsic brightness achieved by the technique, data on x-ray film have shown a signal to background ratio near one, with data on image plates producing a higher background. This has been attributed, without direct evidence, to the interaction of suprathermal electrons with the (high Z) pinhole substrate. We present here the first direct measurement of the hard x-rays produced by such a backlighter target and a test of an approach to reducing the background. Specifically, a thick, low-Z layer was added on the side of the substrate toward the detector, intended to stop the energetic electrons and produce smaller emissions. Results from the Omega-60 laser experiment showed that the oft-seen background signal is in the range of 60-80 keV, a plausible energy range for energetic electrons produced in the laser-irradiated plasma. It also showed a comparable level of background signal in both types of targets. The work presented here includes target design and motivating theory, as well as the unexpected findings about x-ray background production.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of an automatic system for detection and positioning of small pore defects using digital radiography

A recently developed algorithm for positioning of small defects within metal bodies using digital radiography has been experimentally validated. The algorithm has been validated in the high contrast to noise limit. A calibration method has also been developed and validated. The average error in defect interspacings are found to be approximately 0.03mm with a maximum at 0.2 mm, this is at the same order as the errors predicted by simulations. The relative error in interspacings are all less than 2% which is comparable to simulated ideal case at 0.25%.

42 ENGINEERING↗

Characterization of pulsed (plasma focus) neutron source with image plate and application to neutron radiography

Plasma focus device of Mather type developed in house has been used first time for neutron radiography of different objects. The device gives (1.2{+-}0.3) Multiplication-Sign 10{sup 9} neutrons per pulse produced by D-D fusion reaction with a pulse width of 50{+-}5 ns. The method involves exposing sample to be radiographed to thermalized D-D neutrons and recording the image on Fuji-film BAS-ND image plates. The thermal neutron component of the moderated beam was estimated using two image plates: a conventional IP for X-rays and gamma rays, and an IP doped with Gd for detecting neutrons.

07 ISOTOPE AND RADIATION SOURCES↗

Evaluating the presence of porosity in Brazilian archaeological pottery associating x-radiography and PIXE

X-Radiography technique has been used effectively for decades to evaluate and identify differences in homogeneities in samples. It is a simple, fast and non-destructive technique that provides a view of internal structure helping investigating manufacturing details of archaeological ceramics. Characteristics of the paste used in the matrix composition can be derived using PIXE technique through the determination of the major elemental composition allowing the calculation of its expected density. Combining this information with x-ray images is possible to check for differences in the average density of material indicating the presence of homogeneously distributed porosity or temper. The present work evaluates the porosity in a set of native Brazilian pottery sherds that were collected in the Aldeia Lalima archaeological site, located at Mato Grosso do Sul State.

36 MATERIALS SCIENCE↗