At least 325 records · Page 18

High-Sensitivity rf Detection Using an Optically Pumped Comagnetometer Based on Natural-Abundance Rubidium with Active Ambient-Field Cancellation

To detect a specific radio-frequency (rf) magnetic field, rf optically pumped magnetometers (OPMs) require a static magnetic field to set the Larmor frequency of the atoms equal to the frequency of interest. However, unshielded and variable magnetic field environments (e.g., an rf OPM on a moving platform) pose a problem for rf OPM operation. Here, we demonstrate the use of a natural-abundance rubidium vapor to make a comagnetometer to address this challenge. Our implementation builds upon the simultaneous application of several OPM techniques within the same vapor cell. First, we use a modified implementation of an OPM variometer based on 87 Rb to detect and actively cancel unwanted external fields at frequencies ≲60 Hz using active feedback to a set of field control coils. In this experiment, we exploit this stabilized field environment to implement a high-sensitivity rf magnetometer using 85 Rb. Using this approach, we demonstrate the ability to measure rf fields with a sensitivity of approximately 9 fT Hz -1/2 inside a magnetic shield in the presence of an applied field of approximately 20 μT along three mutually orthogonal directions. This demonstration opens up a path toward completely unshielded operation of a high-sensitivity rf OPM.

47 OTHER INSTRUMENTATION↗

Construction of a New MgB 2 Coating System for 1.3-GHz Superconducting RF Cavities at LANL

After many years of evaluating MgB 2 films prepared with various techniques for the application to superconducting radio-frequency (SRF) cavities, we have decided to build a system to coat full-size 1.3-GHz elliptical cavities. This paper describes the design and construction of the system. Additionally, we briefly describe experimental results with a small system and first tests with the new large system. In conclusion, we were able to obtain superconducting samples with a T c of up to 38 K with the small system, but we have not been able to get any superconducting samples with the new system yet.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Frontiers in the Application of RF Vacuum Electronics

The application of radio frequency (RF) vacuum electronics for the betterment of the human condition began soon after the invention of the first vacuum tubes in the 1920s and has not stopped since. Today, microwave vacuum devices are powering important applications in health treatment, material and biological science, wireless communication-terrestrial and space, Earth environment remote sensing, and the promise of safe, reliable, and inexhaustible energy. This article highlights some of the exciting application frontiers of vacuum electronics.

42 ENGINEERING↗

Tunable Plasma Linearizer for Compensation of Nonlinear Energy Chirp

The removal of undesired nonlinear time-energy correlation (energy chirp) present in relativistic electron beams is crucial for many accelerator-based scientific applications, such as free-electron lasers, high-energy electron radiography, and MeV ultrafast electron microscopy. Here, we propose and demonstrate that a low-density plasma section can be used as a passive “linearizer” to significantly compensate for the nonlinear energy chirp imprinted on a beam by the curvature of the radio-frequency field in a conventional accelerator. Physically, the passage of the beam through the plasma excites a strong quasi-cosinoidal longitudinal decelerating wakefield that acts to mitigate the beam’s nonlinear energy chirp by superimposing a reverse chirp on the beam. Time-resolved phase-space measurements, combined with high-fidelity three-dimensional particle-in-cell simulations show that the longitudinal phase space of the beam core is almost completely linearized, leading to a fourfold reduction of the beam overall energy spread from 0.148% to 0.036% (FWHM).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Preheating of Cold, High Moisture Particulate Biomaterials to Reduce Drying Time

Forest Concepts led a two-year project to reduce fossil fuel consumption and improve the energy efficiency of dryers through the application of radio frequency (RF) energy impartation to preheat cold-wet bulk particulate biomass materials. A comprehensive biomass heating and drying mathematical model was developed that enables simulation of drying systems for biomass as well as most other bulk porous particulate materials. Experimental and modeling results conclude that energy consumption for both RF preheating and hot-air preheating are essentially equal for cold, high-moisture feedstocks that are above fiber saturation and therefore not economically beneficial for those conditions. Further results suggest that RF heating may have a direct energy consumption benefit in the late stages of drying and in case of preheating biomass that has a moisture content below fiber saturation. This work was funded in part by the US Department of Energy under contact DE-EE0009130.

09 BIOMASS FUELS↗

Calculation of rf-induced temporal jitter in ultrafast electron diffraction

A significant contribution to the temporal resolution of an ultrafast electron diffraction (UED) instrument is arrival time jitter caused by amplitude and phase variation of radio-frequency (rf) cavities. In this paper, we present a semianalytical approach for calculating rf-induced temporal jitter from klystron and rf cavity parameters. Our approach allows fast estimation of temporal jitter for MeV-UED beamlines and can serve as a virtual timing tool when shot-to-shot measurements of rf amplitude and phase jitters are available. A simulation study for the SLAC MeV-UED instrument is presented, and the temporal resolution of several beamline configurations is compared.

47 OTHER INSTRUMENTATION↗

Influence of oxygen on the optical and electrical properties of magnetron-sputtered indium tin oxide thin films at ambient temperature

Indium Tin Oxide (ITO) thin films are commonly used as transparent conductive layers in the production of solar cells. ITO films are typically heat-treated at temperatures exceeding 200 °C after magnetron sputtering to optimize the physical, optical, and electrical characteristics for photovoltaic devices. Here, this high temperature heating procedure greatly limits the use of potential substrates, particularly those comprised of low-temperature-rated polymers. Herein, we examine the physical, optical, and electrical transport effects of oxygen:argon plasmas during radio frequency magnetron sputtering of ITO on glass and flexible polymer surfaces without subsequent heat treatment. ITO thin films were characterized via sheet resistance testing, UV-Vis spectroscopy, X-ray diffraction, and scanning electron microscopy imaging. Sheet resistance measurements revealed an increase in surface resistance with increasing oxygen concentration during sputtering. UV-Vis optical transmittance measurements demonstrated an improvement in optical transmittance with an increase in oxygen concentration reaching a maximum transmittance at an oxygen concentration of 1-2 %. Most importantly, it was discovered that producing bilayers of ITO with pure argon sputtered plasmas followed by oxygen:argon plasmas produced ITO thin films with suitable resistance and transmittance without the need for high temperature post annealing. These results highlight a methodology for the deposition of ITO thin films on temperature sensitive substrates for flexible photovoltaics and low-cost module production.

36 MATERIALS SCIENCE↗

Plasma-Induced Tailoring of Graphene Oxide Surfaces for Electrochemical Applications: Functionalization and Etching

This study investigates the use of radio frequency air plasma as an eco-friendly method to rapidly and reversibly tailor the surface properties of graphene oxide (GO) films. We observed a transition from hydrophilic (contact angle ∼55°) to superhydrophilic (<10°) with short plasma exposure, attributed to a synergistic combination of surface modification and etching. Spectroscopic analyses (FTIR, XPS) revealed early stage formation of carbonyl groups and reduction of hydroxyls, while longer treatments induced atomic-level etching (AFM) and structural changes (XRD). This surface engineering enhanced the dielectric properties of GO films but led to reduced aqueous stability. The elucidated interplay between plasma-induced functionalization and etching provides valuable insights for the controlled modification of GO surfaces for various applications, including advanced dielectrics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nb 3 Sn Superconducting Cavities by Bronze Routes for Accelerator Stewardship

This project explored the challenges of making Nb 3 Sn superconducting radio-frequency (SRF) cavities by bronze routes. The SRF research community has prioritized Nb 3 Sn for many reasons, including the possibility to operate linacs for stewardship applications in continuous-wave mode with compact cryogenic systems. Existing Nb 3 Sn approaches use a cavity body made of niobium and apply tin to the polished cavity interior, a starting point that contains the main costs of present niobium cavity technology. Further complexity is then added because a high vacuum and temperature >1100 °C must be used to prevent formation of undesirable Nb-Sn phases, de-gas interstitial contaminants, and maintain the high purity of the Nb body. The project sought a more cost-effective solution for the same performance opportunities by exploiting the Cu-Sn-Nb diffusion reactions used to make Nb 3 Sn superconducting wires for magnets, which can be carried out at ~700 °C and are compatible with much cheaper copper cavity bodies. The project also sought understanding of the materials science and factors that affect superconducting properties. The project has impacted SRF cavity technology by demonstrating feasibility of alternative routes that enable compact, high-power electron accelerators for energy, security, environment, medical, and commercial applications.

43 PARTICLE ACCELERATORS↗

A 0.2–2 GHz Time-Interleaved Multistage Switched-Capacitor Delay Element Achieving 2.55–448.6 ns Programmable Delay Range and 330 ns/mm 2 Area Efficiency

Simulation of radar returns, full-duplex systems, and signal repeaters require hundreds of ns of programmable broadband radio frequency (RF) delay in the signal path to simulate large distances in the case of radar returns, for signal cancellation in full-duplex, and for isolation from reflections in signal repeaters. However, programmable broadband RF delay has been limited to ones of ns due to challenges in miniaturization with low loss and low power consumption. In this work, we present a 0.2–2 GHz digitally programmable RF delay element based on a time-interleaved multistage switched-capacitor (TIMS-SC) approach. The proposed approach enables hundreds of ns of broadband RF delay by employing sample time expansion in multiple stages of switched-capacitor storage elements. Further, the delay element was implemented in a 45 nm SOI CMOS process and achieves a 2.55–448.6 ns programmable delay range with < 0.12% delay variation across 1.8 GHz of bandwidth at maximum delay, 2.42 ns programmable delay steps, and 330 ns/mm 2 area efficiency. Through the proposed approach, the device shows minimal delay change across a -40 °C to 85 °C temperature range and < 0.25 dB gain variation across delay settings. The device achieves 26 dB gain, 7.4 dB noise figure, and consumes 74 mW from a 1 V supply with an active area of 1.36 mm 2 .

42 ENGINEERING↗

Stereoscopic detection of hot spots in superfluid 4 He (He II) for accelerator-cavity diagnosis

Superconducting radio-frequency (SRF) cavities cooled by superfluid 4He (He II) are building blocks of many modern particle accelerators due to their high quality factor. However, Joule heating from sub-millimeter surface defects on cavities can lead to cavity quenching, which limits the maximum acceleration gradient of the accelerators. Developing a non-contacting detection technology to accurately locate these surface hot spots is the key to improve the performance of SRF cavities and hence the accelerators. In a recent proof-of-concept experiment, we demonstrated that a molecular tagging velocimetry (MTV) technique based on the tracking of a He molecular tracer line created nearby a surface hot spot in He II can be utilized to locate the hot spot. In order to make this technique practically useful, here we describe our further development of a stereoscopic MTV setup for tracking the tracer line’s motion in three-dimensional (3D) space. We simulate a quench spot by applying a transient voltage pulse to a small heater mounted on a substrate plate. Images of the drifted tracer line, taken with two cameras from orthogonal directions, are used to reconstruct the line profile in 3D space. Here, a new algorithm for analyzing the 3D line profile is developed, which incorporates the finite size effect of the heater. We show that the center location of the heater can be reproduced on the substrate surface with an uncertainty of only a few hundred microns, thereby proving the practicability of this method.

43 PARTICLE ACCELERATORS↗

Coincident learning for beam-based rf station fault identification using phase information at the SLAC linac coherent light source

Anomalies in radio-frequency (rf) stations can result in unplanned downtime and performance degradation in linear accelerators such as SLAC’s Linac Coherent Light Source (LCLS). Detecting these anomalies is challenging due to the complexity of accelerator systems, high data volume, and scarcity of labeled fault data. Prior work identified faults using beam-based detection, combining rf amplitude and beam position monitor data. Due to the simplicity of the rf amplitude data, classical methods are sufficient to identify faults, but the recall is constrained by the low-frequency and asynchronous characteristics of the data. In this work, we leverage high-frequency, time-synchronous rf phase data to enhance anomaly detection in the LCLS accelerator. Due to the complexity of phase data, classical methods fail, and we instead train deep neural networks within the Coincident Anomaly Detection (CoAD) framework. We find that applying CoAD to phase data detects nearly 3 times as many anomalies as when applied to amplitude data, while achieving broader coverage across rf stations. Furthermore, the rich structure of phase data enables us to cluster anomalies into distinct physical categories. Through the integration of auxiliary system status bits, we link clusters to specific fault signatures, providing additional granularity for uncovering the root cause of faults. We also investigate interpretability via Shapley values, confirming that the learned models focus on the most informative regions of the data and providing insight for cases where the model makes mistakes. This work demonstrates that phase-based anomaly detection for rf stations improves both diagnostic coverage and root cause analysis in accelerator systems and that deep neural networks are essential for effective analysis.

Accelerator Physics (physics.acc-ph)↗

Off-line commissioning of the St. Benedict radiofrequency quadrupole cooler-buncher

The St. Benedict ion trapping system, which aims to measure the β - v angular correlation parameter in superallowed-mixed mirror transitions, is under construction at the University of Notre Dame. These measurements will provide much-needed data to improve the accuracy of the V ud element of the CKM matrix. One of the major components of this system is the radio frequency quadrupole cooler-buncher, which is necessary to create low-emittance ion bunches for injection into the measurement Paul trap. The off-line commissioning of the cooler-buncher, using a potassium ion source, determined that the device could produce cooled ion bunches characterized by a 50-ns full-width-half-maximum time width at its exit. The commissioning results also determined the trapping efficiency to be 93(1)% and the trapping half-life to be 20.0(5) s.

Paul trap↗

Experimental investigation of PDI bifurcation of lower hybrid waves during electron density ramp-up in EAST

Abstract The effect of parametric decay instability (PDI) on the current drive efficiency of 4.6 GHz lower hybrid (LH) waves in EAST is investigated experimentally, showing the PDI channel bifurcation of LH waves for the first time in EAST. First, experiments with three platforms of LH power were performed, achieving the LH power required for the PDI occurrence. Second, PDI bifurcation experiments were further carried out by ramping up the plasma electron density. The loop voltage increases with an increase in density, implying a decrease in the current driven by the LH wave. PDI bifurcation during electron density ramp-up was studied by analyzing the parallel refractive index ( n ∥ ) and the frequency spectrum broadening, which is measured with a radio frequency magnetic probe array recently installed close to the LH antenna. It is observed for the first time that they both first increase with density, then there is not much variation and a clear sideband in the frequency spectrum is also observed when the density is up to 4 × 10 19 m − 3 , suggesting a change in the PDI channel. Calculation of the mode growth rate driven by PDI shows that when the edge electron density is up to 1.9 × 10 18 m − 3 , the growth rate of the ion cyclotron quasi-mode (ICQM) will exceed that of the ion sound quasi-mode (ISQM), quantitively explaining that with an increase in density, the PDI channel partly transits from the ISQM to the ICQM channel. Studies provide a possible way to reduce the power deposition in the edge region and improve drive capability by means of mitigating PDI behavior.

Physics↗

High-performance silicon photonic single-sideband modulators for cold-atom interferometry

The laser system is the most complex component of a light-pulse atom interferometer (LPAI), controlling frequencies and intensities of multiple laser beams to configure quantum gravity and inertial sensors. Its main functions include cold-atom generation, state preparation, state-selective detection, and generating a coherent two-photon process for the light-pulse sequence. To achieve substantial miniaturization and ruggedization, we integrate key laser system functions onto a photonic integrated circuit. Our study focuses on a high-performance silicon photonic suppressed-carrier single-sideband (SC-SSB) modulator at 1560 nanometers, capable of dynamic frequency shifting within the LPAI. By independently controlling radio frequency (RF) channels, we achieve 30-decibel carrier suppression and unprecedented 47.8-decibel sideband suppression at peak conversion efficiency of –6.846 decibels (20.7%). We investigate imbalances in both amplitudes and phases between the RF signals. Using this modulator, we demonstrate cold-atom generation, state-selective detection, and atom interferometer fringes to estimate gravitational acceleration, g ≈ 9.77 ± 0.01 meters per second squared, in a rubidium ( 87 Rb) atom system.

47 OTHER INSTRUMENTATION↗

The Frequency Shift and $Q$ of Disordered Superconducting RF Cavities

Niobium superconducting radio-frequency (SRF) cavities for high-energy accelerator applications have been greatly improved in terms of the quality factor $Q$ by techniques such as Nitrogen doping. However, the mechanisms leading to improvement in $Q$ are still not fully understood. Quite recently the SRF group at Fermilab measured anomalies in the frequency shift of N-doped SRF Niobium cavities near the transition temperature. Here we report our theoretical analysis of these results based on the microscopic theory of superconductivity that incorporates anisotropy of the superconducting gap and inhomogeneous disorder in the screening region of the SRF cavities. We are able to account for frequency shift anomalies very close to $T_c$ on the order of fractions of 1 kHz. Our results for the frequency shift and Q are in good agreement with the experimental data reported for all four N-doped Nb SRF cavities by Bafia et al. We also compare our theory with an earlier report on a Nb sample measured at 60 GHz. In addition, we show that the quality factor calculated theoretically has a peak of upper convexity with the largest $Q$ at intermediate levels of disorder. For strong disorder, i.e. the dirty limit, pair breaking in the presence of disorder and screening currents limits the $Q$.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Parallel high-frequency magnetic sensing with an array of flux transformers and multi-channel optically pumped magnetometer for hand MRI application

Here, we investigate an approach for parallel high-frequency magnetic sensing based on a multi-channel radio frequency (RF) optically pumped magnetometer (OPM) coupled to multiple flux transformers (FTs) with a focus on hand magnetic resonance imaging (MRI) application at ultra-low field (ULF). Multiple RF OPM sensing channels are realized by using a single large-area alkali-metal vapor cell and two laser beams for pumping and probing, shared for all the channels. This design leads to significant cost reduction when multi-channel sensing is desirable, as in the case of ULF MRI. The FT, composed of two connected coils, serves as a transmitter of a target magnetic field to the OPM, while decoupling the OPM from untargeted magnetic fields in the sensing area that can limit the OPM performance. For hand MRI application, theoretical and numerical analysis is performed to determine an optimal geometry for the FT array that could improve signal-to-noise ratio (SNR) and sufficiently reduce crosstalk between FTs. We estimate that the optimized multi-channel FT-OPM sensor can achieve a magnetic field sensitivity of the order of 1 fT / Hz 1 / 2 above 100 kHz, which would be sufficient for 1 mm resolution MRI. In general, the multi-channel capability enables simultaneous magnetic measurements, thus reducing the sensing time and improving the SNR, and we anticipate many applications of the multi-channel FT-OPM sensor beyond the targeted here hand MRI: anatomical parallel ULF MRI of the human brain and other parts of the body, airport security screening, magnetic material imaging, and many others.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗