Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation Protection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Evaluating importance maps for TRIPOLI-4{sup R} using deterministic or on-line methods - 25446

Variance reduction is a key ingredient for solving radiation-protection problems with Monte-Carlo particle-transport codes. Many variance-reduction methods require the definition of an importance map and exhibit optimal performance if the importance map is given by the adjoint flux, the solution of the adjoint Boltzmann equation. This paper presents the implementation of the Consistent Adjoint-Driven Importance Sampling (CADIS) methodology via a coupling between the TRIPOLI-4 R Monte-Carlo particle-transport code and the IDT deterministic solver, Additionally, we describe the implementation of a new TRIPOLI-4 R score that makes it possible to estimate the adjoint flux during a direct Monte-Carlo calculation. These new features are expected to simplify the solution of difficult shielding problems. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

A new tubular ironless linear induction motor using non-interrupted winding method

The ironless linear induction motor device can be used for any application which requires a large motion span or rotation restrictedly by the ironless feature due to the strong magnetic field environment. One of the possible applications is ITER diagnostics shutters. The tokamak reactor systems have a severe radiation issue during the operation. The traditional Kapton-insulated wires have significantly lower radiation resistance than an expected large radiation dose at ITER Motion Stark Effect (MSE) shutter location. Furthermore, the traditional single-sided linear induction motor winds the wire to make the N-turn pitch coils independently and then connect them in series to make a one-phase winding. Therefore, it is a big challenge to make so many radiation-protection connectors in such a limited space as inside the vacuum vessel of fusion reactors. The approved mineral-insulated kinds of cables need a large bend radius for the end turns, so the traditional single-sided linear motor with two-layer three-phase windings need to be upgraded to the tubular linear motors. The new proposed tubular ironless linear induction motor can not only overcome the large bend radius issue with the mineral-insulated cables but also allow the motor coils wound continuously around the tubular-shaped stator, forward and backward N times to make a N-turn winding for each phase, in order to resolve the radiation protection issue with the winding connection. The 3D transient Maxwell electromagnetic model with a tubular three-phase linear induction motor has been analyzed. Furthermore, this paper will present the detailed design and winding method of ironless linear induction motor actuators, and results of the 3D transient numerical simulation of the actuator performance.

Ironless↗

Application of adaptive multilevel splitting on coupled neutron-photon TRIPOLI-4{sup R} Monte Carlo simulations - 25427

In the context of radiation protection simulations, the Adaptive Multilevel Splitting (AMS) algorithm is a challenging variance reduction (VR) technique that has been recently investigated in the field of particle transport simulation. It has been implemented in the forthcoming version 11 of the Monte Carlo code TRIPOLI-4{sup R} and successfully tested in neutron-only and photon-only configurations. This paper addresses the application of the AMS algorithm to coupled simulations, and particularly to neutron-photon Monte Carlo calculations. The branching process occurring during the Monte Carlo coupled transport is taken into account in the new coupled-AMS algorithm and is explained in this paper. Two different neutron-photon configurations are then investigated, leading to a comparison of the coupled-AMS algorithm with the analog simulation on the one hand, and with the Exponential Transform (ET) on the other hand, which is the standard VR technique of TRIPOLI-4. Gains up to 30 are obtained in terms of Figure of Merit relatively to the analog simulation, which is about 4 to 6 times more efficient than the ET method for these configurations. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

A Fission-like Neutron Spectrum Shaping Assembly based on D-T Generator

For nearly five decades, 252 Cf sources have been used for testing and calibration over a wide range of neutron detection devices used for nuclear safety and radiation protection. However, the vastly increased cost of 252 Cf sources, its short half-life, and concerns about future shortage have prompted nuclear facilities and radiological calibration laboratories that rely on high-intensity neutron sources to seek alternatives. While there appear to be no other radionuclide neutron sources that would match the 252 Cf performance characteristics, all of them, including 252 Cf, present similar concerns in terms of hazards, safety, and security. As a possible solution to this issue, the Pacific Northwest National Laboratory (PNNL) developed a low-risk, cost-efficient alternative to produce fission-like spectra based on commercially available deuterium-tritium (D-T) neutron generators. The alternative of producing a fission-like neutron spectrum without any fissionable materials or beryllium would enable the nuclear facilities across the entire complex to eliminate their reliance on high intensity 252 Cf sources for nuclear safety and radiation protection applications, substantially reducing risks and associated costs. This report describes efforts of designing the spectrum shaping assembly, its construction and characterization of the neutron field produced. Performance of this newly developed D-T generator based neutron field is demonstrated via calibration of a criticality detector, neutron survey instruments, and personal dosimeters verified against current standardized fields produced by 252 Cf spontaneous fission sources.

42 ENGINEERING↗

Angular distribution of neutron production by proton and carbon-ion therapeutic beams

Carbon-ion beams are increasingly used in the clinical practice for external radiotherapy treatments of deep-seated tumors. At therapeutic energies, carbon ions yield significant secondary products, including neutrons, which may be of concern for the radiation protection of the patient and personnel. We simulated the neutron yield produced by proton and carbon-ion pencil beams impinging on a clinical phantom at three different angles: 15°, 45° and 90°, with respect to the beam axis. We validated the simulated results using the measured response of organic scintillation detectors. We compared the results obtained with FLUKA 2011.2 and MCNPX 2.7.0 based on three different physics models: Bertini, Isabel, and CEM. Over the different ions, energies, and angles, the FLUKA simulation results agree better with the measured data, compared to the MCNPX results. Simulations of carbon ions at low angles exhibit both the highest deviation from measured data and inter-model discrepancy, which is probably due to the different treatment of the pre-equilibrium stage. The reported neutron yield results could help in the comparison of carbon-ion and proton treatments in terms of secondary neutron production for radiation protection applications.

60 APPLIED LIFE SCIENCES↗

MARSAME Radiological Release Report for Archaeological Artifacts Excavated from Area L

In 1991 Los Alamos National Laboratory’s (LANL’s) cultural resources team excavated archaeological site LA 4618 located at Technical Area 54, within Material Disposal Area L (MDA L). MDA L received non-radioactive chemical waste from the early 1960s until 1985. Further development of the MDA required excavation of several cultural sites under National Historic Preservation Act requirements; artifacts from these sites have been subsequently stored at LANL. The LANL cultural resources group would now like to release these artifacts to the Museum of Indian Arts and Culture in Santa Fe for curation. The history of disposal at Area L suggests that the artifact pool is unlikely to be chemically contaminated and LANL staff washed each artifact at least once following excavation. Thus, it is unlikely that the artifacts present a chemical hazard. LANL’s Environmental Stewardship group (EPC-ES) has evaluated the radiological survey results for the Area L artifact pool and found that the items described in this report meet the criteria for unrestricted radiological release under Department of Energy (DOE) Order 458.1 Radiation Protection of the Public and the Environment and are candidates for release without restriction from LANL control. This conclusion is based on the known history of MDA L and on radiation survey data.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-E-P-03: The Australian Clinical Dosimetry Service, a Bespoke National Solution

Purpose: The Australian Clinical Dosimetry Service, (ACDS) was a pilot program to enable the Australian Government to determine whether a locally designed audit program was suitable for mitigating dosimetric error risk to radiotherapy patients within Australia. The outcomes from four years of operations will be presented and discussed with a focus why and how the pilot requirements were met. The consequnces of success will be considered, the lessons learnt from the pilot program and how they are impacting the future ACDS design, operation and engagement with stakeholders. Methods: The ACDS was designed over 2010/11 by experts drawn from the three professions in consultation with the national Department of Health. The list of outcomes required over a three year pilot was expressed in a Memorandum of Understanding, (MoU) between Health and the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA) which hosted the ACDS. Results: The ACDS has achieved all the MoU requirements. This paper describes how the staff within the ACDS engaged with the professional clinical workforce and provided a successful and functioning audit service. It identifies the strengths and weaknesses within the MoU and the ACDS structure and how the ACDS resolved a number of conflicting issues. It identifies the successes within the ACDS and how these were achieved. It provides details to assist and advise those seeking to design or modify national or regional auditing programs. Finally the paper reviews potential futures for the ACDS. Conclusion: The raw number of audits and outcomes indicate that the ACDS has met the MoU auditing requirements. The reasons for the ACDS’ success are highly dependent on: attracting quality staff who can respond with agility to changing situations, a high level of communication with the professional community, a high level of engagement by the community and an interested and engaged Federal Department. The Australian Clinical Dosimetry Service is a joint initiative between the Australian Department of Health and the Australian Radiation Protection and Nuclear Safety Agency.

60 APPLIED LIFE SCIENCES↗

Degradation and reuse of radiative thermal protection system materials for the space shuttle

Three silicide coated columbium alloys and two cobalt alloys were subjected to identical simulated reentry profiling exposures in both static (controlled vacuum leak) and dynamic (hypersonic plasma shear) environments. Primary emphasis in the columbium alloy evaluation was on the Cb752 and C129Y alloys with a lesser amount on FS85. Commercial silicide coatings of the R512E and VH109 formulations were used. The coated specimens were intentionally defected to provide the types of coating flaws that are expected in service. Temperatures were profiled up to peak temperatures of either 2350 F or 2500 F for 15 minutes in each cycle.

Bartlett, E. S.↗

A radiological assessment of space nuclear power operations near Space Station Freedom

In order to accomplish NASA's more ambitious exploration goals, nuclear reactors may be used in the vicinity of Space Station Freedom (SSF) either as power sources for coorbiting platforms or as part of the propulsion system for departing and returning personnel or cargo vehicles. This study identifies ranges of operational parameters, such as parking distances and reactor cooldown times, which would reasonably guarantee that doses to the SSF crew from all radiation sources would be below guidelines recently recommended by the National Council of Radiation Protection and Measurements. The specific scenarios considered include: (1) the launch and return of a nuclear electric propulsion vehicle, (2) the launch and return of a nuclear thermal rocket vehicle, (3) the operation of an SP-100 class reactor on a coorbiting platform, (4) the activation of materials near operating reactors, (5) the storage and handling of radioisotope thermal generator units, and (6) the storage and handling of fresh and previously operated reactors. Portable reactor shield concepts were examined for relaxing the operational constraints imposed by unshielded (for human proximity operations) reactors and that might also be used to provide additional SSF crew protection from natural background radiation.

Stevenson, Steve↗

Sci-Thur PM – Colourful Interactions: Highlights 07: Canadian Computed Tomography Survey: National Diagnostic Reference Levels

Purpose: The Canadian Computed (CT) Tomography Survey sought to collect CT technology and dose index data (CTDI and DLP) at the national level in order to establish national diagnostic reference levels (DRLs) for seven common CT examinations of standard-sized adults and pediatric patients. Methods: A single survey booklet (consisting of four sections) was mailed to and completed for each participating CT scanner. Survey sections collected data on (i) General facility and scanner information, (ii) routine protocols (as available), (iii) individual patient data (as applied) and (iv) manual CTDI measurements. Results: Dose index (CTDIvol and DLP) and associated patient data from 24 280 individual patient exam sequences was analyzed for seven common CT examinations performed in Canada: Adult Head, Chest, Abdomen/Pelvis, and Chest/Abdomen/Pelvis, and Pediatric Head, Chest, and Abdomen. Pediatric examination data was sub-divided into three age ranges: 0–3, 3–7 and 7–13 years. DRLs (75th percentile of dose index distributions) were found for all thirteen groups. Further analysis also permitted segmentation of examination data into 8 sub-groups, whose dose index data was displayed along with group histograms – showing relative contribution of axial vs. helical, contrast use (C+ vs. C-), and application of fixed current vs. dose reduction (DR) – 75th percentiles of DR sub-groups were, in almost all cases, lower than whole group (examination) DRLs. Conclusions: The analysis and summaries presented in the pending survey report can serve to aid local CT imaging optimization efforts within Canada and also contribute further to international efforts in radiation protection of patients.

60 APPLIED LIFE SCIENCES↗

SU-E-T-560: Monte Carlo Simulation of the Neutron Radiation Field Around a Medical 18 MV Linac

Purpose: Today the majority of radiation therapy treatments are performed at medical electron linear accelerators (linacs). The accelerated electrons are used for the generation of bremsstrahlung photons. The use of higher electron respectively photon energies has some advantages over lower energies such as the longer dose build-up. However photons with energies higher than ∼7 MeV can additionally to the interaction with bound electrons undergo inelastic reactions with nuclei. These photonuclear reactions lead to the emission of fast neutrons which contaminate the primary photon field. The neutrons might penetrate through the collimators and deliver out-of-field dose to the patient. Furthermore the materials inside the linac head as well as the air inside the treatment room get activated which might deliver dose to the medical employees even when the linac is not in operation. A detailed knowledge of these effects is essential for adequate radiation protection of the employees and an optimal patient treatment. Methods: It is a common method to study the radiation fields of such linacs by means of Monte Carlo simulations. For the investigation of the effects caused by photonuclear reactions a typical linac in high energy mode (Varian Clinac 18 MV-X) as well as the surrounding bunker were modelled and simulated using the Monte Carlo code FLUKA which includes extensive nuclear reaction and neutron transport models additional to electron-photon transport as well as capabilities for a detailed study of effective dose distributions and activation yields. Results: Neutron spectra as well as neutron effective dose distributions within the bunker were obtained, reaching up to some mSv/Gy in the patient’s plane. The results are normalized per Gy in the depth dose maximum at 10×10 cm{sup 2} field size. Therefore an absolute interpretation is possible. Conclusion: The obtained data gives a better understanding of the photonuclear reaction caused effects.

61 RADIATION PROTECTION AND DOSIMETRY↗

NCRP Program Area Committee 5: Environmental Radiation and Radioactive Waste Issues

Program Area Committee 5 of the National Council on Radiation Protection and Measurements (NCRP) focuses its activities on environmental radiation and radioactive waste issues. Historically this Committee addressed emerging issues of the nation pertaining to radioactivity or radiation in the environment or radioactive waste issues due either to natural origins or to manmade activities. The Committee continues to identify such issues in the future.

environmental impact↗

Radiological Protection Studies for NGLS XTOD

The X-ray transport, optics and diagnostic system (XTOD) starts from the end of bending magnets sending electrons to the main dump and ends at the end wall separating the accelerator tunnel from the user experimental hall (hereafter referred as EH wall), as shown in Figure 1. Figure 1.a shows the general schematic and Figure 1.b shows the initial layout with possible shielding components. This document summarizes the extensive studies on the shielding and collimator system design necessary to meet the radiation protection requirements.

61 RADIATION PROTECTION AND DOSIMETRY↗

A brief overview of compartmental modeling for intake of plutonium via wounds

Here, the aim of this study is to present several approaches that have been used to model the behavior of radioactive materials (specifically Pu) in contaminated wounds. We also review some attempts by the health physics community to validate and revise the National Council on Radiation Protection and Measurements (NCRP) 156 biokinetic model for wounds, and present some general recommendations based on the review. Modeling of intake via the wound pathway is complicated because of a large array of wound characteristics (e.g. solubility and chemistry of the material, type and depth of the tissue injury, anatomical location of injury). Moreover, because a majority of the documented wound cases in humans are medically treated (excised or treated with chelation), the data to develop biokinetic models for unperturbed wound exposures are limited. Since the NCRP wound model was largely developed from animal data, it is important to continue to validate and improve the model using human data whenever plausible.

61 RADIATION PROTECTION AND DOSIMETRY↗

Improving the Success Rate of Delivering Annual Occupational Dosimetry Reports to Persons Issued Temporary External Dosimeters

Workers who are not routinely monitored for occupational radiation exposure at LANL may be issued temporary dosimeters in the field. Per 10CFR835 and DOE O 231.1A, the Laboratory's radiation protection program is responsible for reporting these results to the worker at the end of the year. To do so, the identity of the worker and their mailing address must be recorded by the delegated person at the time the dosimeter is issued. Historically, this data has not been consistently captured. A new online application was developed to record the issue of temporary dosimeters. The process flow of the application was structured such that: 1) the worker must be uniquely identified in the Lab's HR database, and 2) the mailing address of record is verified live time via a commercial web service, for the transaction to be completed. A COPQ savings (Type B1) of $96K/year is demonstrated for the new application.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-200: IBA ProteusOne Compact Proton Therapy System Radiation Survey Results

Purpose: This study summarizes the results of an initial radiation survey of the Willis-Knighton Cancer Center in Shreveport, Louisiana. The facility houses an IBA ProteusOne compact single room proton therapy unit coupled with a C230 cyclotron that operates at a maximum energy of 230 MeV. Methods: A calibrated survey meter was used for the photon measurements to obtain reliable results. A neutron detector was used as the measuring instrument for neutrons. The locations of the survey and measurements were planned carefully in order to get a proper evaluation of the facility shielding configuration. The walls, ceiling, vault entrance, and the adjacent environment were each surveyed with suitable measurement instruments. A total of 22 locations were chosen for radiation survey. Dose equivalent values were calculated for both the photon and the neutron radiation using measured data. Results: All measured dose values are presented in millisievert per year. The highest dose measured at the vault entrance is 0.34 mSv/year. A dedicated shielding door was not present at the time of the measurement. The vault entrance area is considered as a controlled area. The shielding design goals are not to exceed 5 mSv/year for the controlled area and 1 mSv/year the uncontrolled area. The total combined neutron and photon dose equivalent values were found to be compliant with the Louisiana Department of Environmental Quality radiation protection regulatory codes. Conclusion: In our efforts to evaluate the radiation levels at the Willis-Knighton Cancer Center proton treatment facility, we have found that all the measured values of the radiation shielding are below the critical radiation limits per year. Since the total dose measured at the vault entrance is below the shielding design goal, a shielding door is not required at this proton treatment vault.

60 APPLIED LIFE SCIENCES↗