Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Gamma-ray line afterglow from burst environments

We consider photoerosion and direct pair production in a medium surrounding a gamma-ray burst. The resulting secondary gamma-rays may provide diagnostic tools of these environments and, in turn, of the nature of the bursters themselves. In some instances short-lived nuclides are formed; the beta-delayed gamma-rays produced from their decays provide the signatures of the photoerosion. In addition, annihilation radiation produced from positrons resulting from direct pair production is related to the plasma conditions in the medium. We investigate the plausibility of detecting the various radiations. Under extremely favorable conditions, the photoerosion afterglow might be detectable with the present generation of detectors. However, the positron annihilation line should be detectable under a fairly wide range in the conditions of the medium.

Fencl, H. S.↗

Device system and method for miniaturized radiation spectrometer

A device/system for radiation sensing is configured to detect high and low LET radiation. The radiation sensing system may include a high LET detector and a low LET detector coupled to the high LET detector by a CPU, wherein the high LET detector and the low LET detector are assembled within a single unit. The device/system may also include a high LET and low LET detector that may be coupled together without an internal CPU. Overall, the device/system may be a stand-alone system and/or coupled to an external processing device. The device/system may also be approximately 6.times.6.times.2 cm.sup.3 in size, making it hand portable and may weigh less or equal to approximately ninety (90) grams, and operate on less than or approximately 0.25 watts of power.

Stassinopoulos, Epaminondas G.↗

Detection of new celestial objects at far-infrared wavelengths

During a high-altitude balloon flight, sources of far-infrared radiation have been detected with apparent fluxes greater than or about equal to 3 pW/sq cm in the spectral band from 50 to 500 microns. While the sources are not uniquely identifiable with any well-known class of celestial objects, two associations should be noted. Many of the objects lie close to local stars; there is also a tendency to cluster around the ecliptic plane. Alternatively, a new class of celestial objects may have been observed.

Friedlander, M. W.↗

The application of an ultraviolet sensitive fire detector in a manned space vehicle.

Description of a detector which is sensitive to the ultraviolet molecular emissions of flames and has been selected as the basic element of the NASA Skylab fire-detection system. This detector is sensitive to approximately 10 to the minus 12th watts of ultraviolet radiation and will detect small flames at distances in excess of three meters. Its response to a variety of burning spacecraft materials has been investigated both in one-gravity and zero-gravity. The results of experiments conducted in an aircraft flying zero-gravity parabolas in an attempt to simulate the characteristics of a fire which the detector must sense are cited.

Linford, R. M. F.↗

Recent progress in the transition radiation detector techniques

A list of some of the major experimental achievements involving charged particles in the relativistic region are presented. With the emphasis mainly directed to the X-ray region, certain modes of application of the transition radiation for the identification and separation of relativistic charged particles are discussed. Some recent developments in detection techniques and improvements in detector performances are presented. Experiments were also carried out to detect the dynamic radiation, but no evidence of such an effect was observed.

Yuan, L. C. L.↗

Ultraviolet Source For Testing Hydrogen-Fire Detectors

Hand-held portable unit emits ultraviolet light similar to that emitted by hydrogen burning in air. Developed for use in testing optoelectronic hydrogen-fire detectors, which respond to ultraviolet light at wavelengths from 180 to 240 nanometers. Wavelength range unique in that within it, hydrogen fires emit small but detectable amounts of radiation, light from incandescent lamps and Sun almost completely absent, and air sufficiently transmissive to enable detection of hydrogen fire from distance. Consequently, this spectral region favorable for detecting hydrogen fires while minimizing false alarms.

Hall, Gregory A.↗

Growth and photomorphogenesis of pepper plants under red light-emitting diodes with supplemental blue or far-red lighting

Light-emitting diodes (LEDs) are a potential irradiation source for intensive plant culture systems and photobiological research. They have small size, low mass, a long functional life, and narrow spectral output. In this study, we measured the growth and dry matter partitioning of 'Hungarian Wax' pepper (Capsicum annuum L.) plants grown under red LEDs compared with similar plants grown under red LEDs with supplemental blue or far-red radiation or under broad spectrum metal halide (MH) lamps. Additionally, we describe the thermal and spectral characteristics of these sources. The LEDs used in this study had a narrow bandwidth at half peak height (25 nm) and a focused maximum spectral output at 660 nm for the red and 735 nm for the far-red. Near infrared radiation (800 to 3000 nm) was below detection and thermal infrared radiation (3000 to 50,000 nm) was lower in the LEDs compared to the MH source. Although the red to far-red ratio varied considerably, the calculated phytochrome photostationary state (phi) was only slightly different between the radiation sources. Plant biomass was reduced when peppers were grown under red LEDs in the absence of blue wavelengths compared to plants grown under supplemental blue fluorescent lamps or MH lamps. The addition of far-red radiation resulted in taller plants with greater stem mass than red LEDs alone. There were fewer leaves under red or red plus far-red radiation than with lamps producing blue wavelengths. These results indicate that red LEDs may be suitable, in proper combination with other wavelengths of light, for the culture of plants in tightly controlled environments such as space-based plant culture systems.

NASA Discipline Life Support Systems↗

Monolithic Isolated Single-Mode Ring Laser

MISER uses four-sided ring to lase nonreciprocally. Laser concept provides very-compact, efficient, and stable source of coherent radiation. Lasers of single, very-stable frequency desirable for number of purposes. Frequency stability makes possible coherent detection of laser radiation with low-bandwidth detector, useful for communications. Allows very-high-resolution spectroscopy. Any application where desired to use laser in way microwaves used traditionally enhanced if frequency very stable.

Kane, T. J.↗

Interpreting The Unresolved Intensity Of Cosmologically Redshifted Line Radiation

Intensity mapping experiments survey the spectrum of diffuse line radiation rather than detect individual objects at high signal-to-noise ratio. Spectral maps of unresolved atomic and molecular line radiation contain three-dimensional information about the density and environments of emitting gas and efficiently probe cosmological volumes out to high redshift. Intensity mapping survey volumes also contain all other sources of radiation at the frequencies of interest. Continuum foregrounds are typically approximately 10(sup 2)-10(Sup 3) times brighter than the cosmological signal. The instrumental response to bright foregrounds will produce new spectral degrees of freedom that are not known in advance, nor necessarily spectrally smooth. The intrinsic spectra of fore-grounds may also not be well known in advance. We describe a general class of quadratic estimators to analyze data from single-dish intensity mapping experiments and determine contaminated spectral modes from the data themselves. The key attribute of foregrounds is not that they are spectrally smooth, but instead that they have fewer bright spectral degrees of freedom than the cosmological signal. Spurious correlations between the signal and foregrounds produce additional bias. Compensation for signal attenuation must estimate and correct this bias. A successful intensity mapping experiment will control instrumental systematics that spread variance into new modes, and it must observe a large enough volume that contaminant modes can be determined independently from the signal on scales of interest.

INTERPRETING↗

Coaxial anode wire for gas radiation counters

The design and characteristics of a gas radiation counter are discussed. The coaxial anode consists of an elongated central wire covered with an electrically insulating sleeve. Several longitudinally discontinuous segments of an electrically conductive coating are disposed about the insulating sleeve in a coaxial pattern along the length of the central wire. The conductive coating segments form a veto or rejection anode at each end of the central wire and a main or primary charge detecting anode between the ends. The segments are coupled together so that the primary charge detecting anode is connected to detection circuitry in anti-coincidence with the veto anodes. Background radiation detected by either of the veto anodes and the primary charge detecting anode is rejected and the sensitivity of the radiation counter device is increased.

Kraushaar, W. L.↗

Pseudomaster equation for the no-count process in a continuous photodetection

The detection of cavity radiation with the detector placed outside the cavity is studied. Each leaked photon has a certain probability of propagating away without being detected. It is viewed as a continuous quantum measurement in which the density matrix is continuously revised according to the readout of the detector. The concept of pseudomaster equation for the no-count process is introduced; its solution leads to the discovery of the superoperator for the same process. It has the potential to become the key equation for continuous measurement process.

Lee, Ching-Tsung↗

New Neural Network Cloud Mask Algorithm Based on Radiative Transfer Simulations

Cloud detection and screening constitute critically important first steps required to derive many satellite data products. Traditional threshold-based cloud mask algorithms require a complicated design process and fine tuning for each sensor, and they have difficulties over areas partially covered with snow/ice. Exploiting advances in machine learning techniques and radiative transfer modeling of coupled environmental systems, we have developed a new, threshold-free cloud mask algorithm based on a neural network classifier driven by extensive radiative transfer simulations. Statistical validation results obtained by using collocated CALIOP and MODIS data show that its performance is consistent over different ecosystems and significantly better than the MODIS Cloud Mask (MOD35 C6) during the winter seasons over snow-covered areas in the mid-latitudes. Simulations using a reduced number of satellite channels also show satisfactory results, indicating its flexibility to be configured for different sensors. Comparedto threshold-based methods and previous machine-learning approaches, this new cloud mask (i) does not rely on thresholds, (ii) needs fewer satellite channels, (iii) has superior performance during winter seasons in mid-latitude areas, and (iv) can easily be applied to different sensors.

cloud mask algorithms↗

Method and Apparatus for Polaradiometric Pyrometer

A radiation pyrometer for measuring the true temperature of a body is provided by detecting and measuring thermal radiation from the body based on the principle that the effects of angular emission I(sub 1) and reflection I(sub 2) on the polarization states p and s of radiation are complementary such that upon detecting the combined partial polarization state components I(sub p) = I(sub 1p) + I(sub 2p) and I(sub s) = I(sub 1s) + I(sub 2s) and adjusting the intensity of the variable radiation source of the reflected radiation I(sub 2) until the combined partial radiation components I(sub p) and I(sub s) are equal, the effects of emissivity as well as diffusivity of the surface of the body are eliminated, thus obviating the need for any post processing of brightness temperature data.

Abtahi, Ali A.↗

Polaradiometric pyrometer in which the parallel and perpendicular components of radiation reflected from an unpolarized light source are equalized with the thermal radiation emitted from a measured object to determine its true temperature

A radiation pyrometer for measuring the true temperature of a body is provided by detecting and measuring thermal radiation from the body based on the principle that the effects of angular emission I(sub 1) and reflection I(sub 2) on the polarization states p and s of radiation are complementary such that upon detecting the combined partial polarization state components I(sub p) =I(sub 1p) + I(sub 2p) and I(sub s)=I(sub 1s) + I(sub 2s) and adjusting the intensity of the variable radiation source of the reflected radiation I(sub 2) until the combined partial radiation components I(sub p) and I(sub s) are equal, the effects of emissivity as well as diffusivity of the surface of the body are eliminated, thus obviating the need for any post processing of brightness temperature data.

Abtahi, Ali A.↗

Harmonic auroral kilometric radiation of natural origin

When the ISIS 1 satellite passes through the auroral kilometric radiation (AKR) source region the sounder receiver often detects harmonic bands of radiation associated with the fundamental AKR band. These harmonic components were earlier attributed to a nonlinear instrumental response to the strong wide-band bursty AKR fundamental signal. Evidence is here presented that indicates that these harmonics are of natural origin, namely: (1) all the harmonic signals are sometimes observed to have nearly the same bandwidth, (2) when the fundamental signal has two components the harmonic signal sometimes corresponds to the weaker rather than the stronger component, (3) a weak harmonic can be observed to be associated with a weak fundamental, and (4) a 'harmonic' signal can be observed when there is no fundamental.

Benson, R. F.↗

Simultaneous IUE and VLA observations of YZ Canis Minoris, Ad Leonis and Lambda Andromedae

The IUE and VLA simultaneously observed the dwarf M flare stars YZ Canis Minoris and AD Leonis, and the RS CVn star Lambda Andromedae. Narrow-band, slowly varying radiation near 20cm wavelength was detected from YZ Canis Minoris. The radiation cannot be attributed to conventional emission processes, but may be explained by a coherent emission mechanism. The Mg II h and k line intensities also underwent changes in intensity, although the connection between the microwave and ultraviolet variations is unclear. Impulsive microwave bursts were detected from AD Leonis, but there were no significant variations in the Mg II line intensities. Enhancements in several ultraviolet emission lines were detected on timescales of 1 hr from Lambda Andromedae without accompanying variations at 6cm or 20cm wavelength.

Willson, Robert F.↗

Fast, Large Area, Wide Band GAP UV Photodetector for Cherenkov Light Detection

A solid-state radiation detector includes a pattern of conductive metal on a zinc oxide substrate. The pattern provides an arrangement of interdigitated electrode fingers. The wide band gap substrate is sensitive to UV light, which can cause a conductivity change in the substrate. The electrode fingers are configured to sense a difference in substrate conductivity resulting from UV light. The detector has a fast response time, which enables it to detect Cherenkov light. The compact detector provides savings on size, weight, and required power. Thus, the solid-state detector can be used to replace photomultiplier tubes in Cherenkov detectors. The features of the novel detector allow for an improved system to detect and monitor UV radiation, especially during deep space missions.

Wrbanek, John D.↗

High-energy gamma-ray results from the second small astronomy satellite

Data are reported which were obtained with a high-energy (exceeding 35 Mev) gamma-ray telescope flown on the second Small Astronomy Satellite (SAS-2). The high-energy galactic gamma radiation is observed to dominate over the general diffuse radiation along the entire galactic plane, and its longitudinal and latitudinal distributions appear to be generally correlated with galactic structural features, particularly with arm segments. Principally on the basis of its angular distribution and magnitude, it is suggested that this radiation results primarily from cosmic-ray interactions with interstellar matter. A uniform celestial gamma radiation appears to have been detected; the form of its differential spectrum over the energy range from about 35 to 170 MeV is obtained, and a cosmological origin is suggested for this radiation. In addition to the general galactic emission, high-energy gamma radiation was detected from the Crab Nebula, Vela X, a general region toward the galactic center, and a region located a few degrees north of the galactic plane. Upper limits to the high-energy gamma ray fluxes are set for a number of localized sources.

Fichtel, C. E.↗