Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RO”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Effect of different manufacturing methods on polyamide reverse-osmosis membranes for desalination: Insights from molecular dynamics simulations

Membranes are a key technology platform for a broad application of energy-efficient separations. To best serve the separation demands of industry, the manufacturing processes for these membranes are garnering increasing attention. In particular, for water desalination, the industry leading polyamide (PA) reverse osmosis (RO) membranes can be manufactured via molecular layer-by-layer (mLBL) deposition, interfacial polymerization (IP), and 3D-printing technique. However, the influence of different manufacturing methods on PA membrane’s properties is far from understood. Here, in this study, we present the high-pressure transport behavior of water and salt ions for PA membranes formed with IP, mLBL, and 3D-printing through non-equilibrium molecular dynamics simulations. Studies show that membranes fabricated with 3D-printing have similar performances to those manufactured using mLBL, quantified by water permeability, rejection of salt ions, structural integrity, and porosity features. However, the membranes formed with IP exhibit faster water transport, lower rejection, worse structural integrity, and more inhomogeneous network pores than those constructed using mLBL and 3D-printing. The unconnected water-accessible space governs water transport for PA membranes formed with mLBL and 3D-printing, which offers the impermanent open-closed pores that enable water to jump through PA membranes. In contrast, the permeated water-enterable space plays a prominent role in water movement across the PA membrane formed with IP, providing a continuous transport channel at high pressure. Importantly, we observe the more significant compaction features at high pressure for PA membranes formed with IP than mLBL and 3D printing. In short, these findings provide a comprehensive understanding of existing membrane preparation technologies. It also provides a guide for developing the new membrane preparation process at the molecular level.

3D-printing↗

Cost optimization of low-salt-rejection reverse osmosis

Low-salt-rejection reverse osmosis (LSRRO) is an emerging membrane-based desalination technology for concentrating brines with potentially lower energy consumption and cost than thermally driven processes. We assess the technoeconomic performance of LSRRO by using an optimization model that minimizes the levelized cost of water (LCOW). We develop detailed models for the RO module and other equipment using WaterTAP (Water treatment Technoeconomic Assessment Platform), an open-source simulation and optimization software for water treatment. We improve upon previous LSRRO cost optimization studies by optimizing the salt permeability for each stage, which has significant implications for technoeconomic performance. We present the cost-optimal design, operation, and performance for three cases: 35 g/L TDS feed at 70% recovery, 70 g/L at 55%, and 125 g/L at 35%. The cost-optimal LCOW and specific energy consumption (SEC) for these cases are 0.70, 1.89, and 7.41 $/m 3 and 3.9, 8.4, and 30.4 kWh/m 3 , respectively. For each case, we use sensitivity analyses to provide guidance on key factors that impact economic viability. We also present the cost-optimal LCOW and SEC for feed concentrations between 5 and 220 g/L TDS and recoveries between 30 and 90%. So, we compare LSRRO to other high-salinity desalination technologies and find that it may be cost-competitive below feed concentrations of 125 g/L.

54 ENVIRONMENTAL SCIENCES↗

De-Risking High-Recovery Brackish Water Desalination via Flow Reversal and Feed Flushing Using Techno-Economic Assessment

Novel desalination technologies have demonstrated enhanced performance and improved financial metrics over existing processes adopted by industry. Establishing quantitative performance targets is essential for achieving financial benefits over the current state of the art. Herein, we demonstrate how WaterTAP, a techno-economic assessment (TEA) tool, can be used to identify minimum performance metrics necessary to achieve financial benefit over using existing processes. This study evaluates the feasibility of increasing water recovery at the Chino Desalter I above 90 % through the addition of a third variable configuration reverse osmosis (VCRO) stage. Sensitivity analyses revealed flow reversal frequency, feed flushing volume (used as a cleaning step), and membrane lifespan are key factors influencing the financial viability of the VCRO process. The TEA analysis demonstrated that the system must achieve a recovery of 84 % and a 1-year membrane lifespan to have a breakeven LCOW, while achieving 90 % recovery can ultimately reduce the LCOW by 16 %. Notably, a trade-off between decreasing frictional losses and increased osmotic pressure across the recovery range, resulted in a stable specific energy consumption across the recovery range, enabling meaningful LCOW reductions without an energy penalty, a key finding that contrasts with conventional RO. This work demonstrates how TEA can guide system design by identifying key performance targets and exploring trade-offs, enabling data-driven decisions to de-risk innovative processes. These findings underscore the importance of leveraging TEA to evaluate scaling mitigation strategies and optimize inland desalination systems for sustainable and cost-effective operation.

14 SOLAR ENERGY↗

Diesel fuel properties of renewable polyoxymethylene ethers with structural diversity

Polyoxymethylene ethers (POMEs) are a class of low-soot and high-cetane oxygenate oligomers of structure RO-(CH 2 O-) $n$ -R, with different chain lengths ($n$) and end-groups (R) that determine their diesel-like fuel properties. Commercial POMEs with methyl end-groups (MM-POME 3-6 ) exhibit undesirably low energy density and high-water solubility. A previous computational assessment indicated that the lower heating value (LHV) and water solubility for MM-POME 3-6 both improve upon end-group exchange with larger butyl, $iso$-butyl and $iso$-pentyl end-groups. Here, we expanded upon our initial trans-acetalization reaction that employed 1-butanol to install butyl end-groups to also include branched, higher carbon-number end-groups using $iso$-butanol and fusel oil as reagents. Additionally, these new products are termed $i$B*POME 1-6 , and FOil*POME 1-5 , respectively, and collectively referred to as R*POMEs. They possess the advantaged properties of the parent MM-POME 3-6 while exhibiting higher LHV (31 MJ kg -1 and 28 MJ kg -1 for $i$B*POME 1-6 , and FOil*POME 1-5 , respectively) and much reduced water solubility (2.7 g L -1 and 1 g L -1 for $i$B*POME 1-6 , and FOil*POME 1-5 , respectively). Additional fuel property analyses were performed using 20 vol% blends of the R*POMEs with a base diesel fuel. Overall, the greater energy density and decreased water solubility of the R*POMEs, as well as their synergistic blending with diesel at moderate blend levels, provide the greatest benefits to consumers and position this group of products as an environmentally friendlier blendstock alternative to the commercially available MM-POME 3-6 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

One possible source of mass-independent fractionation of sulfur isotopes in the Archean atmosphere of Earth

Energy transfer mechanism for recombination of two sulfur atoms into a diatomic molecule, S 2 , is studied theoretically and computationally to determine whether the rate coefficient of this process can be significantly affected by isotopic substitutions, and whether the resultant isotope effect is expected to be mass-dependent or mass-independent. This is one of sulfur polymerization processes thought to be important in the anoxic atmosphere of the Archean Earth and, potentially, relevant to mass-independent fractionation of sulfur isotopes. A simplified theoretical approach is employed, in which all properties of S 2 molecule are characterized rather accurately, whereas the process of stabilization of metastable S 2 * by bath gas collisions is described approximately. Properties of individual scattering resonances in S 2 are studied in detail, and it is found that most important contributions to the recombination process come from ro-vibrational states formed near the top of centrifugal barrier, and that the number of such states is about 50 (in 32 S 32 S). Absolute value of recombination rate coefficient is computed to be 1.22 x 10 -33 cm 6 /s (for 32 S 32 S at room temperature and atmospheric pressure), close to experimental result. Two distinct isotope effects are identified. One is a classical mass-dependent effect due to translational partition function, which leads to a weak, smooth, and negative mass-dependence of rate coefficient (4% decrease when the mass is raised from 32 S 32 S to 34 S 34 S). Second effect, due to quantized resonances, is two orders of magnitude stronger, but is local. In practice, due to presence of multiple individual resonances, this phenomenon leads to irregular mass-independent variations of rate coefficients in the ranges ±5%. It is also demonstrated that in real molecules this irregular behavior is expected to be somewhat smoother, and the isotope effect is somewhat smaller, due to dependence of stabilization cross section on properties of individual resonances (not described by present model). So additional calculations of stabilization cross sections are needed in order to give quantitative prediction of this mass-independent isotope effect, and to determine its relevance to mass-independent fractionation of sulfur isotopes in the Archean rock record.

58 GEOSCIENCES↗

Catalytic generation of methane at 60–100 °C and 0.1–300 MPa from source rocks containing kerogen Types I, II, and III

Low temperature (60 and 100 °C) and long-term (6 months to 5 years) heating of pre-evacuated and sterilized shales and coals containing kerogen Types I (Mahogany Shale), II (Mowry Shale and New Albany Shale), and III (Springfield Coal and Wilcox Lignite) with low initial maturities (vitrinite reflectance Ro 0.39–0.62%) demonstrates that catalytically generated hydrocarbons may explain the occurrence of some non-biogenic natural gas accumulations where insufficient thermal maturity contradicts the conventional thermal cracking paradigm. Extrapolation of the observed rate of catalytic methanogenesis in the laboratory suggests that significant amounts of sedimentary organic carbon can be converted to relatively dry natural gas over tens of thousands of years in sedimentary basins at temperatures as low as 60 °C. Here, our laboratory experiments utilized source rock (shale and coal) chips sealed in gold and Pyrex® glass tubes in the presence of hydrogen-isotopically contrasting waters. Parallel heating experiments applied hydrostatic pressures from 0.1 to 300 MPa. Control experiments constrained the influence of pre-existing and residual methane in closed pores of rock chips that was unrelated to newly generated methane. This study’s experimental methane yields at 60 and 100 °C are 5–11 orders of magnitude higher than the theoretically predicted yields from kinetic models of thermogenic methane generation, which strongly suggests a contribution of catalytic methanogenesis. Higher temperature, longer heating time, and lower hydrostatic pressure enhanced catalytic methanogenesis. No clear relationships were observed between kerogen type or total organic carbon content and methane yields via catalysis. Catalytic methanogenesis was strongest in Mowry Shale where methane yields at 60 °C amounted to ~2.5 μmol per gram of organic carbon after one year of hydrous heating at ambient pressure. In stark contrast to the earlier findings of hydrogen isotopic exchange between water and thermogenic methane in hydrous pyrolysis experiments above 300 °C, the hydrogen isotopic composition of added water exerted limited influence on the δ2H value of methane generated catalytically at low temperatures. We hypothesize that the catalytic sites responsible for methanogenesis are located in hydrophobic microenvironments with limited access to water. The δ13CCH4 values of methane generated catalytically at 60–100 °C range from ~–57.6 to –41.4‰ and are thus similar to typical thermogenic methane (δ13CCH4 >–50‰) and microbially generated methane (<–55‰). Future studies need to evaluate the possibility that clumped isotope characteristics of catalytically generated methane can diagnose the low-temperature regime of catalytic methanogenesis. Furthermore, testing of freshly cored anoxic rocks is needed to determine whether the use of archived, oxygen-exposed rocks in geochemical maturation/catalysis studies introduces artifacts in experimental hydrocarbon yields.

58 GEOSCIENCES↗

Analyzing the upscaling potential and geospatial siting of calcination-free calcium hydroxide production in the United States

This study evaluates the techno-economic feasibility and the embodied carbon dioxide intensity (eCI) of a novel process for producing nominally pure (>95 mass %) calcium hydroxide without the need for the thermal calcination of limestone. The process relies on the aqueous extraction of calcium from alkaline industrial wastes following which portlandite (Ca(OH) 2 : CH, a.k.a. slaked lime or hydrated lime) is precipitated by application of a waste-heat based thermal swing. This approach takes advantage of the temperature dependent solubility of CH at ambient pressure. We evaluated the feasibility of implementing this process in the U.S. based on the geospatial availability of waste heat and slags as a Ca-source. For the base case, the cost of production of “Low-Temperature Portlandite (LTP)” is 2-to-3 times that of traditional portlandite (~$180/tonne). The main driver of cost is the electricity demand for reverse osmosis (RO) which is used to concentrate Ca-ions in solution, and the costs of membrane replacement. Our sensitivity analysis showed that parity with the cost of production of traditional portlandite is readily achievable by selecting membranes with better durability (i.e., better pH resistance) and flux (i.e., higher permeability) without sacrificing selectivity. Significantly, LTP features an eCI that is between 40%- and - 80 % lower than its traditional counterpart when electricity is sourced from natural gas combustion or wind power, respectively. Finally, our geospatial analysis reveals that there are three areas in the U.S. with the potential for implementation of industrial-scale facilities that could produce at least 50 tonnes of pure Ca(OH) 2 per day, while achieving a production cost of ~$270 per tonne of Ca(OH) 2 , owing to the proximity between slag feedstocks and waste heat sources.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Target Volume Delineation in Oropharyngeal Cancer: Impact of PET, MRI, and Physical Examination

Introduction: Sole utilization of computed tomography (CT) scans in gross tumor volume (GTV) delineation for head-and-neck cancers is subject to inaccuracies. This study aims to evaluate contributions of magnetic resonance imaging (MRI), positron emission tomography (PET), and physical examination (PE) to GTV delineation in oropharyngeal cancer (OPC). Methods: Forty-one patients with OPC were studied. All underwent contrast-enhanced CT simulation scans (CECTs) that were registered with pretreatment PETs and MRIs. For each patient, three sets of primary and nodal GTV were contoured. First, reference GTVs (GTVref) were contoured by the treating radiation oncologist (RO) using CT, MRI, PET, and PE findings. Additional GTVs were created using fused CT/PET scans (GTVctpet) and CT/MRI scans (GTVctmr) by two other ROs blinded to GTVref. To compare GTVs, concordance indices (CI) were calculated by dividing the respective overlap volumes by overall volumes. To evaluate the contribution of PE, composite GTVs derived from CT, MRI, and PET (GTVctpetmr) were compared with GTVref. Results: For primary tumors, GTVref was significantly larger than GTVctpet and GTVctmr (p < 0.001). Although no significant difference in size was noted between GTVctpet and GTVctmr (p = 0.39), there was poor concordance between them (CI = 0.62). In addition, although CI (ctpetmr vs. ref) was low, it was significantly higher than CI (ctpet vs. ref) and CI (ctmr vs. ref) (p < 0.001), suggesting that neither modality should be used alone. Qualitative analyses to explain the low CI (ctpetmr vs. ref) revealed underestimation of mucosal disease when GTV was contoured without knowledge of PE findings. Similar trends were observed for nodal GTVs. However, CI (ctpet vs. ref), CI (ctmr vs. ref), and CI (ctpetmr vs. ref) were high (>0.75), indicating that although the modalities were complementary, the added benefit was small in the context of CECTs. In addition, PE did not aid greatly in nodal GTV delineation. Conclusion: PET and MRI are complementary and combined use is ideal. However, the low CI (ctpetmr vs. ref) particularly for primary tumors underscores the limitations of defining GTVs using imaging alone. PE is invaluable and must be incorporated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Standardizing Naming Conventions in Radiation Oncology

Purpose: The aim of this study was to report on the development of a standardized target and organ-at-risk naming convention for use in radiation therapy and to present the nomenclature for structure naming for interinstitutional data sharing, clinical trial repositories, integrated multi-institutional collaborative databases, and quality control centers. This taxonomy should also enable improved plan benchmarking between clinical institutions and vendors and facilitation of automated treatment plan quality control. Materials and Methods: The Advanced Technology Consortium, Washington University in St. Louis, Radiation Therapy Oncology Group, Dutch Radiation Oncology Society, and the Clinical Trials RT QA Harmonization Group collaborated in creating this new naming convention. The International Commission on Radiation Units and Measurements guidelines have been used to create standardized nomenclature for target volumes (clinical target volume, internal target volume, planning target volume, etc.), organs at risk, and planning organ-at-risk volumes in radiation therapy. The nomenclature also includes rules for specifying laterality and margins for various structures. The naming rules distinguish tumor and nodal planning target volumes, with correspondence to their respective tumor/nodal clinical target volumes. It also provides rules for basic structure naming, as well as an option for more detailed names. Names of nonstandard structures used mainly for plan optimization or evaluation (rings, islands of dose avoidance, islands where additional dose is needed [dose painting]) are identified separately. Results: In addition to its use in 16 ongoing Radiation Therapy Oncology Group advanced technology clinical trial protocols and several new European Organization for Research and Treatment of Cancer protocols, a pilot version of this naming convention has been evaluated using patient data sets with varying treatment sites. All structures in these data sets were satisfactorily identified using this nomenclature. Conclusions: Use of standardized naming conventions is important to facilitate comparison of dosimetry across patient datasets. The guidelines presented here will facilitate international acceptance across a wide range of efforts, including groups organizing clinical trials, Radiation Oncology Institute, Dutch Radiation Oncology Society, Integrating the Healthcare Enterprise, Radiation Oncology domain (IHE-RO), and Digital Imaging and Communication in Medicine (DICOM).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Agreement Among RTOG Sarcoma Radiation Oncologists in Contouring Suspicious Peritumoral Edema for Preoperative Radiation Therapy of Soft Tissue Sarcoma of the Extremity

Purpose: Peritumoral edema may harbor sarcoma cells. The extent of suspicious edema (SE) included in the treatment volume is subject to clinical judgment, balancing the risk of missing tumor cells with excess toxicity. Our goal was to determine variability in SE delineation by sarcoma radiation oncologists (RO). Methods and Materials: Twelve expert ROs were provided with T1 gadolinium and T2-weighted MR images of 10 patients with high-grade extremity soft-tissue sarcoma. Gross tumor volume, clinical target volume (CTV)3cm (3 cm longitudinal and 1.5 cm radial margin), and CTV2cm (2 cm longitudinal and 1 cm radial margin) were contoured by a single observer. Suspicious peritumoral edema, defined as abnormal signal on T2 images, was independently delineated by all 12 ROs. Contouring agreement was analyzed using the simultaneous truth and performance level estimation (STAPLE) algorithm and kappa statistics. Results: The mean volumes of GTV, CTV2cm, and CTV3cm were, respectively, 130 cm{sup 3} (7-413 cm{sup 3}), 280 cm{sup 3} and 360 cm{sup 3}. The mean consensus volume computed using the STAPLE algorithm at 95% confidence interval was 188 cm{sup 3} (24-565 cm{sup 3}) with a substantial overall agreement corrected for chance (mean kappa = 0.71; range: 0.32-0.87). The minimum, maximum, and mean volume of SE (excluding the GTV) were 4, 182, and 58 cm{sup 3} (representing a median of 29% of the GTV volume). The median volume of SE not included in the CTV2cm and in the CTV3cm was 5 and 0.3 cm{sup 3}, respectively. There were 3 large tumors with >30 cm{sup 3} of SE not included in the CTV3cm volume. Conclusion: Despite the fact that SE would empirically seem to be a more subjective volume, a substantial or near-perfect interobserver agreement was observed in SE delineation in most cases with high-grade soft-tissue sarcomas of the extremity. A median of 97% of the consensus SE is within the CTV2cm (99.8% within the CTV3cm). In a minority of cases, however, significant expansion of the CTVs is required to cover SE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Late Toxicity and Patient Self-Assessment of Breast Appearance/Satisfaction on RTOG 0319: A Phase 2 Trial of 3-Dimensional Conformal Radiation Therapy-Accelerated Partial Breast Irradiation Following Lumpectomy for Stages I and II Breast Cancer

Purpose: Late toxicities and cosmetic analyses of patients treated with accelerated partial breast irradiation (APBI) on RTOG 0319 are presented. Methods and Materials: Patients with stages I to II breast cancer ≤3 cm, negative margins, and ≤3 positive nodes were eligible. Patients received three-dimensional conformal external beam radiation therapy (3D-CRT; 38.5 Gy in 10 fractions twice daily over 5 days). Toxicity and cosmesis were assessed by the patient (P), the radiation oncologist (RO), and the surgical oncologist (SO) at 3, 6, and 12 months from the completion of treatment and then annually. National Cancer Institute Common Terminology Criteria for Adverse Events, version 3.0, was used to grade toxicity. Results: Fifty-two patients were evaluable. Median follow-up was 5.3 years (range, 1.7-6.4 years). Eighty-two percent of patients rated their cosmesis as good/excellent at 1 year, with rates of 64% at 3 years. At 3 years, 31 patients were satisfied with the treatment, 5 were not satisfied but would choose 3D-CRT again, and none would choose standard radiation therapy. The worst adverse event (AE) per patient reported as definitely, probably, or possibly related to radiation therapy was 36.5% grade 1, 50% grade 2, and 5.8% grade 3 events. Grade 3 AEs were all skin or musculoskeletal-related. Treatment-related factors were evaluated to potentially establish an association with observed toxicity. Surgical bed volume, target volume, the number of beams used, and the use of bolus were not associated with late cosmesis. Conclusions: Most patients enrolled in RTOG 0319 were satisfied with their treatment, and all would choose to have the 3D-CRT APBI again.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

American Society for Radiation Oncology (ASTRO) 2012 Workforce Study: The Radiation Oncologists' and Residents' Perspectives

Purpose: The American Society for Radiation Oncology (ASTRO) conducted the 2012 Radiation Oncology Workforce Survey to obtain an up-to-date picture of the workforce, assess its needs and concerns, and identify quality and safety improvement opportunities. The results pertaining to radiation oncologists (ROs) and residents (RORs) are presented here. Methods: The ASTRO Workforce Subcommittee, in collaboration with allied radiation oncology professional societies, conducted a survey study in early 2012. An online survey questionnaire was sent to all segments of the radiation oncology workforce. Respondents who were actively working were included in the analysis. This manuscript describes the data for ROs and RORs. Results: A total of 3618 ROs and 568 RORs were surveyed. The response rate for both groups was 29%, with 1047 RO and 165 ROR responses. Among ROs, the 2 most common racial groups were white (80%) and Asian (15%), and the male-to-female ratio was 2.85 (74% male). The median age of ROs was 51. ROs averaged 253.4 new patient consults in a year and 22.9 on-treatment patients. More than 86% of ROs reported being satisfied or very satisfied overall with their career. Close to half of ROs reported having burnout feelings. There was a trend toward more frequent burnout feelings with increasing numbers of new patient consults. ROs' top concerns were related to documentation, reimbursement, and patients' health insurance coverage. Ninety-five percent of ROs felt confident when implementing new technology. Fifty-one percent of ROs thought that the supply of ROs was balanced with demand, and 33% perceived an oversupply. Conclusions: This study provides a current snapshot of the 2012 radiation oncology physician workforce. There was a predominance of whites and men. Job satisfaction level was high. However a substantial fraction of ROs reported burnout feelings. Perceptions about supply and demand balance were mixed. ROs top concerns reflect areas of attention for the healthcare sector as a whole.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Prospective Study of {sup 18}FDG-PET With CT Coregistration for Radiation Treatment Planning of Lymphomas and Other Hematologic Malignancies

Purpose: This prospective single-institution study examined the impact of positron emission tomography (PET) with the use of 2-[{sup 18}F] fluoro-2-deoxyglucose and computed tomography (CT) scan radiation treatment planning (TP) on target volume definition in lymphoma. Methods and Materials: 118 patients underwent PET/CT TP during June 2007 to May 2009. Gross tumor volume (GTV) was contoured on CT-only and PET/CT studies by radiation oncologists (ROs) and nuclear medicine physicians (NMPs) for 95 patients with positive PET scans. Treatment plans and dose-volume histograms were generated for CT-only and PET/CT for 95 evaluable sites. Paired t test statistics and Pearson correlation coefficients were used for analysis. Results: 70 (74%) patients had non-Hodgkin lymphoma, 10 (11%) had Hodgkin lymphoma, 12 (10%) had plasma-cell neoplasm, and 3 (3%) had other hematologic malignancies. Forty-three (45%) presented with relapsed/refractory disease. Forty-five (47%) received no prior chemotherapy. The addition of PET increased GTV as defined by ROs in 38 patients (median, 27%; range, 5%-70%) and decreased GTV in 41 (median, 39.5%; range, 5%-80%). The addition of PET increased GTV as defined by NMPs in 27 patients (median, 26.5%; range, 5%-95%) and decreased GTV in 52 (median, 70%; range, 5%-99%). The intraobserver correlation between CT-GTV and PET-GTV was higher for ROs than for NMPs (0.94, P<.01 vs 0.89, P<.01). On the basis of Bland-Altman plots, the PET-GTVs defined by ROs were larger than those defined by NMPs. On evaluation of clinical TPs, only 4 (4%) patients had inadequate target coverage (D95 <95%) of the PET-GTV defined by NMPs. Conclusions: Significant differences between the RO and NMP volumes were identified when PET was coregistered to CT for radiation planning. Despite this, the PET-GTV defined by ROs and NMPs received acceptable prescription dose in nearly all patients. However, given the potential for a marginal miss, consultation with an experienced PET reader is highly encouraged when PET/CT volumes are delineated, particularly for questionable lesions and to assure complete and accurate target volume coverage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Funding Support and Principal Investigator Leadership of Oncology Clinical Trials Using Radiation Therapy

Sources of funding and principal investigator (PI) leadership for clinical trials using radiation therapy (RT) are not well characterized but are important mediators of innovation, particularly because funding for trials from the National Institutes of Health (NIH) has decreased and industry funding has increased. We sought to determine characteristics of trials using RT that are associated with industry funding, NIH funding, and radiation oncologist (RO) PI leadership.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Trends in Financial Relationships Between Industry and Radiation Oncologists Versus Other Physicians in the United States from 2014 to 2018

The Open Payments transparency program publishes data on industry-physician payments, in part to discourage relationships considered inappropriate including gifts, meals, and speaker’s bureau fees. We evaluated trends in physician-level payments to test whether implementation of Open Payments resulted in fewer industry–radiation oncologist (RO) interactions or shifted interactions toward those considered more appropriate compared with medical oncologists (MOs) and other hospital-based physicians (HBPs).

62 RADIOLOGY AND NUCLEAR MEDICINE↗