Commissioning report of the MuCool 5 Tesla solenoid coupled with helium refrigerator

MuCool 5T solenoid was successfully cooled down and operated coupled with MTA 'Brown' refrigerator. The system performed as designed with substantial performance margin. All process alarms and interlocks, as well as ODH and fire alarms, were active and performed as designed. The cooldown of the refrigerator started from warm conditions and took 44 hours to accumulate liquid helium level and solenoid temperature below 5K. Average liquid nitrogen consumption for the refrigerator precool and solenoid shield was measured as 20 gal/hr (including boil-off). Helium losses were small (below 30 scfh). The system was stable and with sufficient margin of performance and ran stably without wet expansion engine. Quench response demonstrated proper operation of the relieving devices and pointed to necessity of improving tightness of the relieving manifolds. Boil-off test demonstrated average heat load of 3 Watts for the unpowered solenoid. The solenoid can stay up to 48 hours cold and minimally filled if the nitrogen shield is maintained. A list of improvements includes commencing into operations the second helium compressor and completion of improvements and tune-ups for system efficiency.

43 PARTICLE ACCELERATORS↗

Comparative Performance of Low Global Warming Potential (GWP) Refrigerants as Replacement for R-410A in a Regular 2-Speed Heat Pump for Sustainable Cooling

Heat pumps are currently being developed to reduce the energy footprint for residential and commercial building space conditioning and water heating loads in cold climates. To mitigate the nocuous impact of greenhouse gas emissions on the environment, and to create a carbon-neutral building stock, alternate lower-GWP refrigerants must also replace the predominant use of R-410A, without re-engineering the mechanical hardware. In this paper, we analyze the performance of lower-GWP alternative refrigerants (R-32, R-452B, R-454B, and R-466A) relative to the conventional R-410A and draw conclusions on the relative performances to meet cooling loads. The simulations are accomplished using the heat pump design model, a well-known, public-domain design tool with a free web interface and downloadable desktop version to support public use and the HVAC R&D community. The contributions contain detailed, hardware-based heat exchanger and system analyses to provide a comprehensive assessment. The results of the simulation are scrutinized from the first (capacity and energy efficiency) and second laws (exergy analysis) to identify sources of systemic inefficiency, the root cause of lost work. This rigorous approach provides an exhaustive analysis of alternate lower-GWP refrigerants to replace R-410A using the same hardware. The results have practical value in engineering heat pumps in an economy that is compelled to alter by the consequences and uncertainties of climate change, to reduce its anthropogenic carbon footprint.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Variable Refrigerant Flow Heat Pump Computer Model in EnergyPlus

This paper provides an overview of the variable refrigerant flow heat pump computer model included with the Department of Energy's EnergyPlusTM whole-building energy simulation software. The mathematical model for a variable refrigerant flow heat pump operating in cooling or heating mode, and a detailed model for the variable refrigerant flow direct-expansion (DX) cooling coil are described in detail.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Magnetocaloric Materials Revolutionize Refrigeration Technology

Researchers at Oak Ridge National Laboratory have partnered with General Electric (GE) Appliances on a building technologies project to revolutionize today’s 100-year-old home refrigeration technology. Using magnetocaloric materials (MCM), they’ve eliminated the need for a vapor compression cycle, associated refrigerants, and their negative environmental impacts. The research team is currently working to determine the most effective means to transfer heat from the solid MCM, and using fluid passed through high-resolution microchannels shows promise. This technology has the potential to reduce energy consumption by 25%, and GE hopes to commercialize magnetocaloric refrigerators for use in homes by 2020.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Testing and Modeling of Supermarket Refrigeration Systems as a Demand Response Resource

Supermarkets offer a substantial demand response (DR) resource because of their high energy intensity and use patterns; however, refrigeration as the largest load has been challenging to access. Previous work has analyzed supermarket DR using heating, ventilating, and air conditioning; lighting; and anti-sweat heaters. This project evaluated and quantified the DR potential inherent in supermarket refrigeration systems in the Bonneville Power Administration service territory. DR events were carried out and results measured in an operational 45,590-ft2 supermarket located in Hillsboro, Oregon. Key results from the project include the rate of temperature increase in freezer reach-in cases and walk-ins when refrigeration is suspended, the load shed amount for DR tests, and the development of calibrated models to quantify available DR resources. Simulations showed that demand savings of 15 to 20 kilowatts (kW) are available for 1.5 hours for a typical store without precooling and for about 2.5 hours with precooling using only the low-temperature, non-ice cream cases. This represents an aggregated potential of 20 megawatts within BPA's service territory. Inability to shed loads for medium-temperature (MT) products because of the tighter temperature requirements is a significant barrier to realizing larger DR for supermarkets. Store owners are reluctant to allow MT case set point changes, and laboratory tests of MT case DR strategies are needed so that owners become comfortable testing, and implementing, MT case DR. The next-largest barrier is the lack of proper controls in most supermarket displays over ancillary equipment, such as anti-sweat heaters, lights, and fans.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Proposed Methodology for LEED Baseline Refrigeration Modeling (Presentation)

This PowerPoint presentation summarizes a proposed methodology for LEED baseline refrigeration modeling. The presentation discusses why refrigeration modeling is important, the inputs of energy models, resources, reference building model cases, baseline model highlights, example savings calculations and results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

LARGE SCALE REFRIGERATION PLANT FOR GROUND TESTING THE JAMES WEBB TELESCOPE AT NASA JOHNSON SPACE CENTER

The James Webb Telescope is the successor to the Hubble Telescope and will be placed in an orbit of 1.5 million km from earth. Before launch in 2014, the telescope will be tested in NASA Johnson Space Center's (JSC) space simulation chamber, Chamber A. The tests will be conducted at deep space conditions. Chamber A's helium cryo-panels are currently cooled down to 20 K by two Linde 3.5 kW helium refrigerators. The new 12.5 kW, 20-K helium coldbox described in this paper is part of the upgrade to the chamber systems for this large test program. The Linde coldbox will provide refrigeration in several operating modes where the temperature of the chamber is being controlled with a high accuracy due to the demanding NASA test requirements. The implementation of two parallel expansion turbine strings and the Ganni cycle—Floating Pressure process results in a highly efficient and flexible process that minimizes the electrical input power. This paper will describe the collaboration and execution of the coldbox project.

42 ENGINEERING↗

Virtual refrigerant charge sensor for variable-speed heat pumps based on feature selection

The refrigerant charge level in heat pump systems significantly impacts their energy efficiency. Virtual refrigerant charge (VRC) sensing technology has been comprehensively investigated and well-established due to its lower cost compared to physical sensors. However, the previous VRC research often relied on expert judgment and physical reasoning for their variable selection, which can potentially select redundant (or highly correlated) or insignificant features, and it is also primarily focused on single-speed systems. To address these challenges, this study proposes a VRC algorithm for variable-speed heat pumps that selects features through a rigorous feature selection method in combination with physical insights. We also propose a piecewise linear model structure segmented by subcooling temperature to accurately predict charge levels, particularly when subcooling temperatures are substantially low. The proposed algorithm was evaluated using experimental data of a residential R410A heat pump, and the performance was compared with two baseline VRC algorithms. The results are: (1) The proposed algorithm outperforms for the case with subcooling temperature less than 1 °C. (2) The proposed algorithm achieves a tested mean absolute percentage error (MAPE) of 4.23%, and improves the overall accuracy for cooling conditions by approximately 60%, compared with the two baseline algorithms. (3) The proposed algorithm uses two fewer features and improves the accuracy for undercharge cooling conditions by 68.0%, compared with baseline algorithm 2. These improvements enhance prediction accuracy and prevent overfitting, providing a more reliable refrigerant charge level prediction and helping improve the heat pump energy efficiency.

Liang, Chenjiyu↗

Seasonal performance evaluation of zero-superheat active refrigerant charge control for variable-speed heat pumps

Heat pumps account for a significant portion of electricity consumption in buildings, making their energy efficiency a critical area of research. Control optimization is recognized as an effective approach for enhancing the efficiency of building HVAC systems. Specifically, since the efficiency of heat pumps increases with reduced superheat and the optimal refrigerant charge level varies with operating conditions, zero-superheat active charge control is a promising strategy to maximize the system’s COP. However, due to its complexity, this control strategy remains in the research phase and has only been tested under limited operating conditions. This paper proposes a methodology to evaluate the seasonal performance improvement of zero-superheat active charge control across a full range of heating conditions in buildings. The methodology includes the development of an optimal controller that utilizes an accumulator to store excess refrigerant and manages the active charge level at zero superheat through subcooling control, as well as the creation of a detailed physics-based heat pump model. Targeted a 3-ton variable-speed heat pump with R410A refrigerant, we selected ten U.S. cities representing different climate regions for seasonal performance evaluation. Our simulations indicate that, depending on the climate conditions, the optimal control strategy could achieve energy savings ranging from 5.8 % to 8.0 % over the entire heating season. These results suggest that zero-superheat active charge control, combined with coordinated compressor and fan speeds, could substantially improve the energy efficiency of heat pump systems while maintaining the required heating capacity.

Guo, Fangzhou↗

A comprehensive modeling of falling film evaporators subject to vapor flow, pass arrangements, and refrigerants

Improving the heat transfer performance of falling film evaporators is a crucial step for improving the energy efficiency of the heat pump or refrigeration systems. This study conducts a numerical investigation for the practical-scale falling film evaporator based on the epsilon–NTU method with an updated heat transfer correlation. The algorithm was validated with lab-scale and real-scale falling film evaporator experimental results, and the prediction reaches a mean absolute deviation of 12.5%. Here, the parametric study encompasses eight refrigerants: R-134a, R-410A, R-600a, R-717, R-1270, R-152a, R-1234yf, and R-1234ze(E). The results indicate that vaporization enthalpy of refrigerant is a key property in selecting an appropriate working fluid because it helps minimize severe heat transfer degradation caused by dry-out. Additionally, the vapor-flow–induced heat transfer degradation can be predicted using the critical Weber number. Furthermore, the trade-off between extending the tube length and increasing the number of tubes for heat transfer improvement is discussed. Finally, different two-pass arrangements show deviations of less than 4 %.

Dry-out↗

Parametric Studies of Heat Pump Water Heater Using Low GWP Refrigerants

A storage heat pump water heater (HPWH) comprises a vapor compression system and a hot water tank. It can lead to more than 70% energy saving, compared with electric resistance heating. HPWH usually uses a wrapped-tank coil as the water heater. The wrapped coil has a strong interaction with the water tank and impose a new challenge for the engineering design and simulation study. Based on the US DOE/ORNL Heat Pump Design Model (HPDM), i.e., a public-domain, component-based thermal system modelling platform, a segment-to-segment wrapped-tank coil model coupled with a one-dimensional stratified water tank model were developed, which facilitates modeling and design HPWHs having various configurations and components. Additionally, the hardware-based design model was used to evaluate refrigerants having lower global warming potentials to replace R-134a, including R-1234yf, R-1234ze, R-290, R-513A and R-450A, when effects of compressor size, refrigerant charge on 24-hour uniform energy factor (UEF) and first-hour rating (FHR) were investigated.In the drop-in replacements, R-1234ze achieved the best UEF, and R-290 resulted in the lowest UEF. When downsizing the compressor to maximize the UEFs, the UEFs of R-134a, R-290, R1234yf, R-450A and R-513A ascended to the range of 4.4 to 4.53, with R-513A having the highest UEF. The R-1234ze ended up having the lowest UEF of 4.27. Refrigerants having larger volumetric vaporization heat led to higher FHRs if using the fixed-size compressor, that R-290 resulted in the highest FHR.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Approximation of refrigerant thermophysical properties using neural networks to speed up transient thermofluid simulations

Accurate and efficient evaluations of refrigerant thermophysical properties and their partial derivatives are essential for transient simulations of thermofluid systems, where several computations need to be executed at each integration time step. Since the utilization of an Equation of State for retrieving properties based on a pair of independent inputs typically involves numerical iterations in solution procedures, when the input variables differ from the refrigerant state variables employed in dynamic models, a variety of approaches including lookup table interpolation and curve fitting have been developed to explicitly approximate these properties based on the state variables, and consequently eliminate internal iterations. This paper presents an alternative method that exploits derivative-informed neural networks to model refrigerant properties explicitly from inputs of pressure and enthalpy, while ensuring consistent partial derivatives generated by differentiating the neural networks. Computational speed and accuracy of the proposed approach are demonstrated via transient simulations of a discretized heat exchanger model in Modelica, and comparisons against other property evaluation routines. Simulation results indicate that the proposed approach can realize a significant speedup with negligible discrepancies in predicted transients. The method is implemented in an open-source Modelica library.

Ma, Jiacheng↗

Design, Project Execution, and Commissioning of the 1.8 K Superfluid Helium Refrigeration System for SRF Cryomodule Testing

The Fermilab Cryomodule Test Facility (CMTF) provides a test bed to measure the performance of superconducting radiofrequency (SRF) cryomodules (CM). These SRF components form the basic building blocks of future high intensity accelerators such as the International Linear Collider (ILC) and a Muon Collider. Linde Kryotechnik AG and Linde Cryogenics have designed, constructed and commissioned the superfluid helium refrigerator needed to support SRF component testing at the CMTF Facility. The hybrid refrigerator is designed to operate in a variety of modes and under a wide range of boundary conditions down to 1.8 Kelvin set by CM design. Special features of the refrigerator include the use of warm and cold compression and high efficiency turbo expanders.This paper gives an overview on the wide range of the challenging cooling requirements, the design, fabrication and the commissioning of the installed cryogenic system.

43 PARTICLE ACCELERATORS↗

Hydrothermal Synthesis and Solid-State Laser Refrigeration of Ytterbium-Doped Potassium-Lutetium-Fluoride (KLF) Microcrystals

Hydrothermal methods are used for the first time to synthesize distinct crystallographic stoichiometries within the potassium-lutetium-fluoride phase diagram for applications in solid-state laser refrigeration. Four crystalline phases were synthesized hydrothermally and doped with 10% Yb(III) ions, namely, orthorhombic K 2 LuF 5 (space group Pnma), trigonal KLuF 4 (space group P3 1 21), orthorhombic KLu 2 F 7 (space group Pna2 1 ), and cubic KLu 3 F 10 (space group $Fm\bar{3m}$), with each phase exhibiting unique microcrystalline morphologies. Among the four phases, the most significant cooling was observed for the KLuF 4 phase, which showed an overall refrigeration of 8.6 ± 2.1 K below room temperature. Laser refrigeration for KLuF4 was measured by observing both the eigenfrequencies of optomechanical cantilevers in vacuum and also the Brownian dynamics of optically trapped microcrystals in water. Cooling was also observed for the first time for the K 2 LuF 5 phase in vacuum based on measurements of the mean luminescence wavelength of Yb(III) ions. Finally, cooling was not observed with the other two phases.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Limited options for low-global-warming-potential refrigerants

Hydrofluorocarbons, currently used as refrigerants in air-conditioning systems, are potent greenhouse gases, and their contribution to climate change is projected to increase. Future use of the hydrofluorocarbons will be phased down and, thus replacement fluids must be found. Here we show that only a few pure fluids possess the combination of chemical, environmental, thermodynamic, and safety properties necessary for a refrigerant and that these fluids are at least slightly flammable.We search for replacements by applying screening criteria to a comprehensive chemical database. For the fluids passing the thermodynamic and environmental screens (critical temperature and global warming potential), we simulate performance in small air-conditioning systems, including optimization of the heat exchangers. We show that the efficiency-versus-capacity trade-off that exists in an ideal analysis disappears when a more realistic system is considered. Furthermore, the maximum efficiency occurs at a relatively high volumetric refrigeration capacity, but there are few fluids in this range.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Hall D solenoid helium refrigeration system at JLab

Hall D, the new Jefferson Lab experimental facility built for the 12GeV upgrade, features a LASS 1.85 m bore solenoid magnet supported by a 4.5 K helium refrigerator system. This system consists of a CTI 2800 4.5 K refrigerator cold box, three 150 hp screw compressors, helium gas management and storage, and liquid helium and nitrogen storage for stand-alone operation. The magnet interfaces with the cryo refrigeration system through an LN2-shielded distribution box and transfer line system, both designed and fabricated by JLab. The distribution box uses a thermo siphon design to respectively cool four magnet coils and shields with liquid helium and nitrogen. We describe the salient design features of the cryo system and discuss our recent commissioning experience.

42 ENGINEERING↗

Electroluminescent refrigeration by ultra-efficient GaAs light-emitting diodes

Electroluminescence—the conversion of electrons to photons in a light-emitting diode (LED)—can be used as a mechanism for refrigeration, provided that the LED has an exceptionally high quantum efficiency. We investigate the practical limits of present optoelectronic technology for cooling applications by optimizing a GaAs/GaInP double heterostructure LED. We develop a model of the design based on the physics of detailed balance and the methods of statistical ray optics, and predict an external luminescence efficiency of η ext = 97.7% at 263 K. To enhance the cooling coefficient of performance, we pair the refrigerated LED with a photovoltaic cell, which partially recovers the emitted optical energy as electricity. For applications near room temperature and moderate power densities (1.0–10 mW/cm 2 ), we project that an electroluminescent refrigerator can operate with up to 1.7× the coefficient of performance of thermoelectric coolers with ZT = 1, using the material quality in existing GaAs devices. We also predict superior cooling efficiency for cryogenic applications relative to both thermoelectric and laser cooling. Large improvements to these results are possible with optoelectronic devices that asymptotically approach unity luminescence efficiency.

36 MATERIALS SCIENCE↗

Compact, portable, automatic sample changer stick for cryostats and closed-cycle refrigerators

Beamlines are facilities that produce and deliver highly focused and intense beams of radiation, typically x rays, synchrotron radiation, or neutrons, for scientific research purposes. Millions of dollars are spent annually to maintain and operate these scientific beamlines, oftentimes running continuously between cycles. To reduce human intervention and improve productivity, mechanical sample changers are often commissioned for use. Designing sample changers is difficult because mechanical parts can be bulky, expensive, and challenging to design for instruments with low volume access, high radiation, and cryogenic environments. We present a portable and inexpensive sample changer stick that can hold and manipulate up to four samples, specifically designed for use with cryogenic closed-cycle refrigerators. The sample changer stick enables rapid and efficient exchange of samples without manual intervention, and is compatible with standard sample mounts such as vanadium cans. The sample changer stick includes a motorized rotation and lancing mechanism, which enables the precise positioning of each sample in the neutron beam, while ensuring compatibility with the operating temperatures and vacuum conditions required for closed-cycle refrigerators. The design has been successfully tested at the VISION beamline at the Spallation Neutron Source. The mechanical action and software controls are detailed. Furthermore, the sample changer stick is a valuable tool for scientists working with cryogenic closed-cycle refrigerators.

36 MATERIALS SCIENCE↗