Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “READOUT SYSTEMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

A Graphene-Based Terahertz Hot Electron Bolometer with Johnson Noise Readout

In this paper, we present the development of a graphene-based hot electron bolometer with Johnson noise readout. The bolometer is a graphene microbridge connected to a log spiral antenna by Au contact pads. The Fourier transform spectrometer measurement shows the bolometer has high coupling efficiency in the frequency range from 0.3 to 1.6 THz. Using 300/77 K blackbody loads, we measure an optical noise equivalent power of 5.6 × 10{sup −12} W/Hz{sup 0.5} at 3.0 K. To understand the thermal transport inside the graphene microbridge, we measure the bolometers with different microbridge lengths at different bath temperatures. We find that the thermal conductance due to electron diffusion is significant in the bolometers.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Error-Correcting Codes for Code-Division Multiplexed TES Detectors

Transition edge sensors (TESs) have proven to be highly sensitive and versatile X-ray spectrometers. Upcoming missions, including Athena X-IFU, will rely on highly multiplexed focal planes where more than 32 TES pixels are read out using a single SQUID amplifier channel. We have implemented an error correction algorithm for code-division multiplexed TES signals that can compensate for potential failures of individual SQUID readout channels and that is both scalable and easily implemented in hardware. We present this algorithm for error correction and show results of laboratory tests to assess algorithm performance at recovering TES channels after a SQUID failure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of Surface Roughness Effect on Super–Normal Transition of Ti/Au Transition Edge Sensor Calorimeters

We are developing transition edge sensor (TES) X-ray microcalorimeters for the future Japanese mission DIOS. It adopts microstrip readout wiring for low pixel-to-pixel crosstalk. In past samples, TES films composed of Ti and Au have not shown proper super–normal transition when it is deposited on the wiring. Assuming that surface roughness of the substrate can influence the transition, we reduced the surface roughness of the underneath layer before deposition of the TES film by using chemical mechanical polishing. We then found that the substrate becomes much smoother with a roughness of <1 nm rms and the TES film shows a proper transition.

36 MATERIALS SCIENCE↗

A Kinetic Inductance Ammeter with Coplanar Waveguide Input Structure for Magnetic Flux Focusing

We propose a multiplexible kinetic inductance ammeter, which uses a high-quality-factor, superconducting, lumped-element, kinetic inductance resonator as a current sensor, a short, superconducting coplanar waveguide (CPW) for current input, and a CPW transmission line for the sensor readout. The resonator consists of an interdigitated capacitor and a superconducting loop that inductively couples to the input CPW. Current running through the central line of the input CPW generates magnetic fields which are focused into the gaps of the input CPW. These magnetic fields can be measured collectively as the magnetic flux through the superconducting loop. The kinetic inductance of the superconducting loop depends on the screening current for the magnetic flux, so the input current is converted to a change in the frequency of the resonator. We analyze the response and noise of a kinetic inductance ammeter with a high-resistivity NbN loop.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Readout of X-ray Pulses from a Single-pixel TES Microcalorimeter with Microwave Multiplexer Based on SQUIDs Directly Coupled to Resonators

We have first demonstrated the cooperation between an X-ray TES and a directly coupled microwave SQUID multiplexer (D-coup. MW-Mux) in which SQUIDs are directly coupled to resonators. Using D-coup. MW-Mux, we successfully detected the X-ray pulses from a single-pixel TES and evaluated the energy resolution of 11.8 eV FWHM at 5.9 keV. We found this preliminary energy resolution is attributed to non-optimum bias point of the present TES, which can be improved by the future reduction of readout noise.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design of a readout circuit incorporating a 12-bit analog-to-digital converter for cooled infrared focal plane array

The infrared focal plane array (IRFPA) is gradually becoming more systematic. In order to enhance the signal processing capabilities, analog-to-digital converters (ADC) integrated into the readout integrated circuit (ROIC) is an important development trend. However, the cryogenic effects of MOSFET devices will affect the conversion accuracy of the ADC at 77 K. In this paper, the main parameters of MOSFET are extracted at 77 K in 0.18 μm CMOS process, and a cryogenic model is established. Based on this, a digital ROIC is designed, which integrates a 12-bit single-slope integral ADC in pixel unit. By applying continuous integral ramp generator and mixed-voltage comparator, a high-linearity and low-power consumption single-slope ADC is realized for the cooled readout circuit. The measured dynamic effective number of bits of the ADC at 77 K is 10.92 bits, the static no-missing code resolution reaches 11.99 bits, the maximum differential nonlinear |DNL| < 1LSB and maximum integral nonlinear |INL| < 1LSB. This paper realizes the design of a digital ROIC for IRFPA and improves the simulation accuracy at 77 K.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A redox proteomics approach to investigate the mode of action of nanomaterials

Numbers of engineered nanomaterials (ENMs) are steadily increasing. Therefore, alternative testing approaches with reduced costs and high predictivity suitable for high throughput screening and prioritization are urgently needed to ensure a fast and effective development of safe products. In parallel, extensive research efforts are targeted to understanding modes of action of ENMs, which may also support the development of new predictive assays. Oxidative stress is a widely accepted paradigm associated with different adverse outcomes of ENMs. It has frequently been identified in in vitro and in vivo studies and different assays have been developed for this purpose. Fluorescent dye based read-outs are most frequently used for cell testing in vitro but may be limited due to possible interference of the ENMs. Recently, other assays have been put forward such as acellular determination of ROS production potential using methods like electron spin resonance, antioxidant quantification or the use of specific sensors. In addition, Omics based approaches have gained increasing attention. In particular, redox proteomics can combine the assessment of oxidative stress with the advantage of getting more detailed mechanistic information. Here we propose a comprehensive testing strategy for assessing the oxidative stress potential of ENMs, which combines acellular methods and fast in vitro screening approaches, as well as a more involved detailed redox proteomics approach. This allows for screening and prioritization in a first tier and, if required, also for unraveling mechanistic details down to compromised signaling pathways. - Highlights: • Oxidative stress is a general paradigm for nanomaterial hazard mechanism of action. • Reactive oxygen species generation can be predicted using acellular assays. • Cellular assays based on fluorescence suffer from interference by nanomaterials. • Protein carbonylation is an irreversible and predictive mark of oxidative stress. • Proteomics of carbonylation indicates affected pathways and mechanism of action.

60 APPLIED LIFE SCIENCES↗

Spin wave based parallel logic operations for binary data coded with domain walls

We numerically investigate the feasibility of spin wave (SW) based parallel logic operations, where the phase of SW packet (SWP) is exploited as a state variable and the phase shift caused by the interaction with domain wall (DW) is utilized as a logic inversion functionality. A designed functional element consists of parallel ferromagnetic nanowires (6 nm-thick, 36 nm-width, 5120 nm-length, and 200 nm separation) with the perpendicular magnetization and sub-μm scale overlaid conductors. The logic outputs for binary data, coded with the existence (“1”) or absence (“0”) of the DW, are inductively read out from interferometric aspect of the superposed SWPs, one of them propagating through the stored data area. A practical exclusive-or operation, based on 2π periodicity in the phase logic, is demonstrated for the individual nanowire with an order of different output voltage V{sub out}, depending on the logic output for the stored data. The inductive output from the two nanowires exhibits well defined three different signal levels, corresponding to the information distance (Hamming distance) between 2-bit data stored in the multiple nanowires.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

3 ns single-shot read-out in a quantum dot-based memory structure

Fast read-out of two to six charges per dot from the ground and first excited state in a quantum dot (QD)-based memory is demonstrated using a two-dimensional electron gas. Single-shot measurements on modulation-doped field-effect transistor structures with embedded InAs/GaAs QDs show read-out times as short as 3 ns. At low temperature (T = 4.2 K) this read-out time is still limited by the parasitics of the setup and the device structure. Faster read-out times and a larger read-out signal are expected for an improved setup and device structure.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Current-based detection of nonlocal spin transport in graphene for spin-based logic applications

Graphene has been proposed for novel spintronic devices due to its robust and efficient spin transport properties at room temperature. Some of the most promising proposals require current-based readout for integration purposes, but the current-based detection of spin accumulation has not yet been developed. In this work, we demonstrate current-based detection of spin transport in graphene using a modified nonlocal geometry. By adding a variable shunt resistor in parallel to the nonlocal voltmeter, we are able to systematically cross over from the conventional voltage-based detection to current-based detection. As the shunt resistor is reduced, the output current from the spin accumulation increases as the shunt resistance drops below a characteristic value R*. We analyze this behavior using a one-dimensional drift-diffusion model, which accounts well for the observed behavior. These results provide the experimental and theoretical foundation for current-based detection of nonlocal spin transport.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Frequency multiplexing for readout of spin qubits

We demonstrate a low loss, chip-level frequency multiplexing scheme for readout of scaled-up spin qubit devices. By integrating separate bias tees and resonator circuits on-chip for each readout channel, we realise dispersive gate-sensing in combination with charge detection based on two radio frequency quantum point contacts. We apply this approach to perform multiplexed readout of a double quantum dot in the few-electron regime and further demonstrate operation of a 10-channel multiplexing device. Limitations for scaling spin qubit readout to large numbers of multiplexed channels are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Novel latch for adiabatic quantum-flux-parametron logic

We herein propose the quantum-flux-latch (QFL) as a novel latch for adiabatic quantum-flux-parametron (AQFP) logic. A QFL is very compact and compatible with AQFP logic gates and can be read out in one clock cycle. Simulation results revealed that the QFL operates at 5 GHz with wide parameter margins of more than ±22%. The calculated energy dissipation was only ∼0.1 aJ/bit, which yields a small energy delay product of 20 aJ·ps. We also designed shift registers using QFLs to demonstrate more complex circuits with QFLs. Finally, we experimentally demonstrated correct operations of the QFL and a 1-bit shift register (a D flip-flop)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A microfabricated fringing field capacitive pH sensor with an integrated readout circuit

This work presents a microfabricated fringe-field capacitive pH sensor using interdigitated electrodes and an integrated modulation-based readout circuit. The changes in capacitance of the sensor result from the permittivity changes due to pH variations and are converted to frequency shifts using a crossed-coupled voltage controlled oscillator readout circuit. The shift in resonant frequency of the readout circuit is 30.96 MHz for a change in pH of 1.0–5.0. The sensor can be used for the measurement of low pH levels, such as gastric acid, and can be integrated with electronic pills. The measurement results show high repeatability, low noise, and a stable output.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Experimental determination of the elastic cotunneling rate in a hybrid single-electron box

We report measurements of charge configurations and charge transfer dynamics in a hybrid single-electron box composed of aluminum and copper. We used two single-electron transistors (SETs) to simultaneously read out different parts of the box, enabling us to map out stability diagrams of the box and identify various charge transfer processes in the box. We further characterized the elastic cotunneling in the box, which is an important source of error in electron turnstiles consisting of hybrid SETs, and found that the rate was as low as 1 Hz at degeneracy and compatible with theoretical estimates for electron tunneling via virtual states in the central superconducting island of the box.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Wireless Josephson amplifier

Josephson junction parametric amplifiers are playing a crucial role in the readout chain in superconducting quantum information experiments. However, their integration with current 3D cavity implementations poses the problem of transitioning between waveguide, coax cables, and planar circuits. Moreover, Josephson amplifiers require auxiliary microwave components, like directional couplers and/or hybrids, that are sources of spurious losses and impedance mismatches that limit measurement efficiency and amplifier tunability. We have developed a wireless architecture for these parametric amplifiers that eliminates superfluous microwave components and interconnects. This greatly simplifies their assembly and integration into experiments. We present an experimental realization of such a device operating in the 9–11 GHz band with about 100 MHz of amplitude gain-bandwidth product, on par with devices mounted in conventional sample holders. The simpler impedance environment presented to the amplifier also results in increased amplifier tunability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A high frequency resonance gravity gradiometer

A new setup OGRAN—the large scale opto-acoustical gravitational detector is described. As distinguished from known gravitational bar detectors it uses the optical interferometrical readout for registering weak variations of gravity gradient at the kilohetz frequency region. At room temperature, its sensitivity is limited only by the bar Brownian noise at the bandwidth close to 100 Hz. It is destined for a search for rare events—gravitational pulses coincident with signals of neutrino scintillator (BUST) in the deep underground of Baksan Neutrino Observatory of INR RAS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A diamond based neutron spectrometer for diagnostics of deuterium-tritium fusion plasmas

Single crystal Diamond Detectors (SDD) are being increasingly exploited for neutron diagnostics in high power fusion devices, given their significant radiation hardness and high energy resolution capabilities. The geometrical efficiency of SDDs is limited by the size of commercially available crystals, which is often smaller than the dimension of neutron beams along collimated lines of sight in tokamak devices. In this work, we present the design and fabrication of a 14 MeV neutron spectrometer consisting of 12 diamond pixels arranged in a matrix, so to achieve an improved geometrical efficiency. Each pixel is equipped with an independent high voltage supply and read-out electronics optimized to combine high energy resolution and fast signals (<30 ns), which are essential to enable high counting rate (>1 MHz) spectroscopy. The response function of a prototype SDD to 14 MeV neutrons has been measured at the Frascati Neutron Generator by observation of the 8.3 MeV peak from the {sup 12}C(n, α){sup 9}Be reaction occurring between neutrons and {sup 12}C nuclei in the detector. The measured energy resolution (2.5% FWHM) meets the requirements for neutron spectroscopy applications in deuterium-tritium plasmas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗