Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION LENGTH”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

High rate synthesis of crystalline silicon films from SiH{sub 4}+He using high density microwave plasma

By using a high density microwave-induced plasma source, depositions of crystalline silicon films from SiH{sub 4}+He mixture are investigated systematically. Microwave power and SiH{sub 4} flow rate are used as the variable deposition parameters. Results demonstrate that film deposition rate increases with increasing both the microwave power and the SiH{sub 4} flow rate. While film crystallinity promotes with increasing the microwave power but degrades with increasing the SiH{sub 4} flow rate. After optimizing the film deposition conditions, highly crystallized Si films are deposited at a rate higher than 1000 nm/s. Promotion of the dissociation efficiency of source gases and enhancement in the diffusion length of film precursors on growing surface are suggested to be main factors responsible for the simultaneous achievements of the high deposition rate and the high film crystallinity. Mechanisms under these phenomena are discussed in detail.

36 MATERIALS SCIENCE↗

Laser processes in plasmadynamic flows

Radiation emitted from the exhaust flow of a multi-megawatt, quasi-steady magnetoplasmadynamic accelerator has been examined photoelectrically for argon mass flows from 6 to 32 g/sec and arc currents up to 25 kA. Vacuum ultraviolet radiation, indicative of resonance transitions, has been detected photoelectrically at various axial locations downstream of the arc chamber, consistent with a relaxation length calculated using a collisional-radiative recombination model. Photoelectric measurements of particular transitions in the neutral and first ionic state of argon show that populations of excited electronic states of AII are in excess of that which would be expected on the basis of Saha-Boltzmann equilibrium at the local electron temperature and number density. Optical depth measurements indicate that for a current of 4 kA and argon mass flow of 12 g/sec, a population inversion exists between the upper and lower states of the 0.4880 micron argon ion transition.

Campbell, E. M.↗

Mesoscale modeling of solute precipitation and radiation damage

This report summarizes the low length scale effort during FY 2014 in developing mesoscale capabilities for microstructure evolution in reactor pressure vessels. During operation, reactor pressure vessels are subject to hardening and embrittlement caused by irradiation-induced defect accumulation and irradiation-enhanced solute precipitation. Both defect production and solute precipitation start from the atomic scale, and manifest their eventual effects as degradation in engineering-scale properties. To predict the property degradation, multiscale modeling and simulation are needed to deal with the microstructure evolution, and to link the microstructure feature to material properties. In this report, the development of mesoscale capabilities for defect accumulation and solute precipitation are summarized. Atomic-scale efforts that supply information for the mesoscale capabilities are also included.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

RADIATIVE COOLING IN RELATIVISTIC COLLISIONLESS SHOCKS: CAN SIMULATIONS AND EXPERIMENTS PROBE RELEVANT GAMMA-RAY BURST PHYSICS?

We address the question of whether numerical particle-in-cell (PIC) simulations and laboratory laser-plasma experiments can (or will be able to, in the near future) model realistic gamma-ray burst (GRB) shocks. For this, we compare the radiative cooling time, t{sub cool}, of relativistic electrons in the shock magnetic fields to the microscopic dynamical time of collisionless relativistic shocks-the inverse plasma frequency of protons, {omega}{sup -1}{sub pp}. We obtain that for t{sub cool}{omega}{sup -1} {sub pp}{approx}< few hundred, the electrons cool efficiently at or near the shock jump and are capable of emitting away a large fraction of the shock energy. Such shocks are well resolved in existing PIC simulations; therefore, the microscopic structure can be studied in detail. Since most of the emission in such shocks would be coming from the vicinity of the shock, the spectral power of the emitted radiation can be directly obtained from finite-length simulations and compared with observational data. Such shocks have very high radiative efficiency and correspond to the internal baryon-dominated GRB shocks for the conventional range of ejecta parameters. Fermi acceleration of electrons in such shocks is limited by electron cooling, hence the emitted spectrum should be lacking a nonthermal tail, whereas its peak likely falls in the multi-MeV range. For lower radiative efficiency shocks, these constraints are relaxed: the peak energy is smaller and the nonthermal tail can be expected to form. Incidentally, the conditions in internal shocks are almost identical to those in laser-produced plasmas; thus, such GRB-like plasmas can be created and studied in laboratory experiments using the presently available Petawatt-scale laser facilities. An analysis of the external shocks shows that only the highly relativistic shocks, corresponding to the extremely early afterglow phase, can have efficient electron cooling in the shock transition. We emphasize the importance of radiative PIC simulations for further studies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multi-Group Reductions of LTE Air Plasma Radiative Transfer in Cylindrical Geometries

Air plasma radiation in Local Thermodynamic Equilibrium (LTE) within cylindrical geometries is studied with an application towards modeling the radiative transfer inside arc-constrictors, a central component of constricted-arc arc jets. A detailed database of spectral absorption coefficients for LTE air is formulated using the NEQAIR code developed at NASA Ames Research Center. The database stores calculated absorption coefficients for 1,051,755 wavelengths between 0.04 μm and 200 μm over a wide temperature (500K to 15 000K) and pressure (0.1 atm to 10.0 atm) range. The multi-group method for spectral reduction is studied by generating a range of reductions including pure binning and banding reductions from the detailed absorption coefficient database. The accuracy of each reduction is compared to line-by-line calculations for cylindrical temperature profiles resembling typical profiles found in arc-constrictors. It is found that a reduction of only 1000 groups is sufficient to accurately model the LTE air radiation over a large temperature and pressure range. In addition to the reduction comparison, the cylindrical-slab formulation is compared with the finite-volume method for the numerical integration of the radiative flux inside cylinders with varying length. It is determined that cylindrical-slabs can be used to accurately model most arc-constrictors due to their high length to radius ratios.

Reductions↗

Advanced properties of extended plasmas for efficient high-order harmonic generation

We demonstrate the advanced properties of extended plasma plumes (5 mm) for efficient harmonic generation of laser radiation compared with the short lengths of plasmas (∼0.3–0.5 mm) used in previous studies. The harmonic conversion efficiency quadratically increased with the growth of plasma length. The studies of this process along the whole extreme ultraviolet range using the long plasma jets produced on various metal surfaces, particularly including the resonance-enhanced laser frequency conversion and two-color pump, are presented. Such plasmas could be used for the quasi-phase matching experiments by proper modulation of the spatial characteristics of extended ablating area and formation of separated plasma jets.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Generation of Soft X-Ray Radiation in a Compact Free-Electron Laser with Harmonic Multiplication

Single-pass free-electron lasers (FELs) with harmonic multiplication in the X-ray range are studied theoretically with the objective of producing intense radiation with the minimum possible FEL length, beam energy, and seed laser frequency. A cascade FEL with a two-frequency undulator for electron bunching at wavelengths of higher harmonics is proposed. The dynamics of radiation power in a FEL with harmonic multiplication cascades is investigated based on a well-proven phenomenological FEL model that covers all major losses for each harmonic in each FEL cascade. The effect of the beam quality on X-ray generation in a FEL is examined. It is demonstrated that electron beams with energy spread σ{sub e} ≤ 0.0002 are required for efficient use of harmonics in a cascade X-ray FEL. The evolution of power of harmonics in several cascade FELs at wavelengths of ~2–3 nm with multiplication of seed harmonics at a wavelength of 13.51 nm (Mo/Si reflection peak) and 11.43 nm (MoRu/Be reflection peak) is studied. It is demonstrated that the power increases to ~1 GW at a FEL length up to 40 m. In addition, the operation of multicascade FELs with a seed F{sub 2} excimer 157-nm UV laser and harmonics of lasers with CO{sub 2} and C{sub 2}H{sub 2} at 30 nm with a beam of electrons with an energy of ~0.6 GeV and a current of ~1 kА is studied. The power of the modeled X-ray radiation of these FELs at λ = 2.5 and 3.3 nm increases to ~0.5 GW at ~30 m.

43 PARTICLE ACCELERATORS↗

Novel Bunch Length Diagnostic, Phase I. Interim report

We Report Progress to date in the development of a Novel Bunch Length Diagnostic which uniquely uses the spatial profile of coherent transition radiation or coherent diffraction radiation to measure the root mean square average bunch length of an electron beam produced by an accelerator. This new technique can potentially be applied to a wide variety of accelerators and is simple and straightforward to use.

43 PARTICLE ACCELERATORS↗

Charge Carrier Diffusion Length Determination in 4H-SiC Schottky Alpha Detectors

When developing semiconductor radiation detectors detailed characterization of the detector behavior is required. The ability of a semiconductor radiation detector to collect the charge liberated by incident ionizing radiation is a critical characteristic. Several factors influence the charge collection efficiency of a semiconductor radiation detector, including electron-hole trapping, applied electric field strength, and dopant concentrations and dimensions of low doped regions. Applying a reverse bias electric potential to a low doped semiconductor region creates a free charge carrier depleted region and establishes an electric field which can remove subsequently freed charge in the form of an electrical signal. When ionizing radiation is incident upon a semiconductor electron-hole pairs are generated. These charge carriers are created along the path of the ionizing radiation regardless of the doping concentration. However, only the charge freed in the low doped epitaxial region of a detector will be collected as a result of the applied electric field. When the electric field is insufficient to develop a depleted region equal to or larger than the range of the ionizing radiation in the detector material some charge freed by the ionizing radiation outside of the sensitive region will be lost, thus potentially resulting in less than complete charge collection. The incomplete collection of charge complicates the analysis of the incident particle energy spectrum. Charge freed in the highly doped bulk region beyond the low doped epitaxial region may diffuse back into the low doped depleted region and be subsequently included in the integral pulse. The amount of charge collected as a result of this diffusion mechanism is dependent upon the diffusion length of the charge carriers in the material. The diffusion length is subsequently dependent on the material properties of the detector including the number of defects, trapping centers, and temperature. In order to fully characterize the properties of 4H-SiC as a radiation detector the diffusion length was calculated by adjusting the theoretical diffusion length value used in the calculation of the charge collection efficiency to agree with empirically observed charge collection efficiencies. The discrepancy between the observed and theoretical charge collection efficiency at 50 to 150 volts applied bias indicates an unexplained charge collection phenomenon which is contributing to the larger than predicted charge collection efficiency of the detectors. This voltage range corresponds to an intermediate applied bias, indicating that either the theoretical depletion width is too short, the diffusion length varies with the composition of the region that the charge carriers are diffusing through, or some other phenomenon is involved. If the charge carrier diffusion length varies depending on whether or not the diffusing charge is freed in unbiased epitaxy or bulk layer, then a function describing the variation of the diffusion layer could be determined by measuring the diffusion length at the applied voltages used previously, but over a range of epitaxial layer thicknesses. Future work includes the characterization of the effects of high temperature operation on the diffusion length of 4H-SiC in addition to measuring the effects of varying energy alpha emitter electrodeposition on the observed diffusion length. Additional Schottky barrier contacts, namely those with a nickel-platinum contact, will be tested in various sizes which have been developed in order to eliminate certain failure mechanisms and explore the potential effects of Schottky contact size on charge collection efficiency. (authors)

36 MATERIALS SCIENCE↗

Characteristics of concrete reflection of {sup 235}U systems

Water reflection is considered in nuclear criticality safety evaluations because it is readily available and easily forms a close-fitting reflector around fissile material. Concrete is commonly encountered in industrial environments and can be a more effective reflector than water. A comprehensive study using 32 concrete compositions derived from an extensive literature survey was done for the three basic one-dimensional geometries used in radiation transport codes (spherical, infinite length cylindrical, and infinite extent slab) using a {sup 235}U metal/water fissile mixture. The concentration/moderation range over which criticality is possible was spanned, and the change in k{sub eff} per unit change in element atomic number density for various concrete composition elements was computed to determine the relative effect of each element on neutron multiplication. The results show that: -1) the most effective reflector is not the same for each geometry; -2) in general, for each geometry, Δk{sub eff}/ΔN has similar values for {sup 235}U concentrations >0.200 g/cm{sup 3}; and -3) for {sup 235}U concentrations < 0.200 g/cm{sup 3}, the value of Δk{sub eff}/ΔN diminishes toward zero.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Collective-Interaction Control and Reduction of Optical Frequency Shot Noise in Charged-Particle Beams

We present a theoretical model for longitudinal collective Coulomb interactions in a charged-particle beam. It suggests a possibility to control and reduce optical frequency shot-noise current in accelerated electron beams. For short interaction lengths, the model describes well coherent optical transition radiation effects observed in SLAC LCLS and in other laboratories. For longer interaction lengths (quarter plasma oscillation period) the model predicts the possibility to reduce the beam current noise below the classical shot-noise level, an effect not yet observed experimentally at optical frequencies.

43 PARTICLE ACCELERATORS↗

TURBULENT DYNAMICS IN SOLAR FLARE SHEET STRUCTURES MEASURED WITH LOCAL CORRELATION TRACKING

High-resolution observations of the Sun's corona in extreme ultraviolet and soft X-rays have revealed a new world of complexity in the sheet-like structures connecting coronal mass ejections (CMEs) to the post-eruption flare arcades. This article presents initial findings from an exploration of dynamic flows in two flares observed with Hinode/XRT and SDO/AIA. The flows are observed in the hot ({approx}> 10 MK) plasma above the post-eruption arcades and measured with local correlation tracking. The observations demonstrate significant shears in velocity, giving the appearance of vortices and stagnations. Plasma diagnostics indicate that the plasma {beta} exceeds unity in at least one of the studied events, suggesting that the coronal magnetic fields may be significantly affected by the turbulent flows. Although reconnection models of eruptive flares tend to predict a macroscopic current sheet in the region between the CME and the flare arcade, it is not yet clear whether the observed sheet-like structures are identifiable as the current sheets or 'thermal halos' surrounding the current sheets. Regardless, the relationship between the turbulent motions and the embedded magnetic field is likely to be complicated, involving dynamic fluid processes that produce small length scales in the current sheet. Such processes may be crucial for triggering, accelerating, and/or prolonging reconnection in the corona.

79 ASTRONOMY AND ASTROPHYSICS↗

Bone Fractures Following External Beam Radiotherapy and Limb-Preservation Surgery for Lower Extremity Soft Tissue Sarcoma: Relationship to Irradiated Bone Length, Volume, Tumor Location and Dose

Purpose: To examine the relationship between tumor location, bone dose, and irradiated bone length on the development of radiation-induced fractures for lower extremity soft tissue sarcoma (LE-STS) patients treated with limb-sparing surgery and radiotherapy (RT). Methods and Materials: Of 691 LE-STS patients treated from 1989 to 2005, 31 patients developed radiation-induced fractures. Analysis was limited to 21 fracture patients (24 fractures) who were matched based on tumor size and location, age, beam arrangement, and mean total cumulative RT dose to a random sample of 53 nonfracture patients and compared for fracture risk factors. Mean dose to bone, RT field size (FS), maximum dose to a 2-cc volume of bone, and volume of bone irradiated to >=40 Gy (V40) were compared. Fracture site dose was determined by comparing radiographic images and surgical reports to fracture location on the dose distribution. Results: For fracture patients, mean dose to bone was 45 +- 8 Gy (mean dose at fracture site 59 +- 7 Gy), mean FS was 37 +- 8 cm, maximum dose was 64 +- 7 Gy, and V40 was 76 +- 17%, compared with 37 +- 11 Gy, 32 +- 9 cm, 59 +- 8 Gy, and 64 +- 22% for nonfracture patients. Differences in mean, maximum dose, and V40 were statistically significant (p = 0.01, p = 0.02, p = 0.01). Leg fractures were more common above the knee joint. Conclusions: The risk of radiation-induced fracture appears to be reduced if V40 <64%. Fracture incidence was lower when the mean dose to bone was <37 Gy or maximum dose anywhere along the length of bone was <59 Gy. There was a trend toward lower mean FS for nonfracture patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Oncentra brachytherapy planning system

In modern cancer management, treatment planning has progressed as a contemporary tool with all the advances in computing power in recent years. One of the advanced planning tools uses 3-dimensional (3D) data sets for accurate dose distributions in patient prescription. Among these planning processes, brachytherapy has been a very important part of a successful cancer management program, offering clinical benefits with specific or combined treatments with external beam therapy. In this chapter, we mainly discussed the Elekta Oncentra planning system, which is the main treatment planning tool for high-dose rate (HDR) modality in our facility and in many other facilities in the United States. HDR is a technically advanced form of brachytherapy; a high-intensity radiation source (3.6 mm in length) is delivered with step motor in submillimeter precision under computer guidance directly into the tumor areas while minimizing injury to surrounding normal healthy tissue. Oncentra planning is the key component to generate a deliverable brachytherapy procedure, which is executed on the microSelectron V3 remote afterloader treatment system. Creating a highly conformal plan can be a time-consuming task. The development of Oncentra software (version 4.5.3) offers a variety of useful tools that facilitate many of the clinical challenging tasks for planning, such as contouring and image reconstruction, as well as rapid planning calculations with dose and dose volume histogram analysis. Oncentra Brachy module creates workflow and optimizes the planning accuracy for wide varieties of clinical HDR treatments, such as skin, gynecologic (GYN), breast, prostate, and many other applications. The treatment file can also be transferred to the afterloader control station for speedy delivery. The design concept, calculation algorithms, and optimization modules presented some key characteristics to plan and treat the patients effectively and accurately. The dose distribution and accuracy of several clinical sample cases were discussed to illustrate the effectiveness and clinical efficacy. The American Association of Physicists in Medicine brachytherapy reports of TG-43 and TG-186 were also described and compared in evaluations of fundamental calculation methodologies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optical radiation from regions downstream of mercury bombardment thrusters

A 0.5 meter focal length, plane grating monochromator was used to measure the radiance of spectral radiation emanating from regions downstream of a mercury bombardment thruster. The wavelength range investigated was 2800 A. This radiation was due primarily to the radiative decay of excited mercury atoms exhausted from the thruster. Radiance values ranged from 10 to the minus 11th power to 10 to the minus 9th power W/sq cm sr, varying with wavelength. For resonant radiation, the spectral radiance may exceed 10 to the minus 8th power W/sq cm sr. From such radiance measurements, it was concluded that the thruster background radiation should not interfere with the control functions of a star tracker viewing through the thruster exhaust, provided that the tracker is designed to operate with a sufficiently small field of view.

Milder, N. L.↗

Optical radiation from regions downstream of mercury bombardment thrusters.

Use of a 0.5-m focal length, plane grating monochromator to measure the radiance of spectral radiation emanating from regions downstream of a mercury bombardment thrustor in the wavelength range investigated was 2800 to 6000 A. This radiation was due primarily to the radiative decay of excited mercury atoms exhausted from the thrustor. Radiance values ranged from 10 to the minus 11th to 10 to the min scm/ster varying with wavelength. For resonant radiation, the spectral radiance may exceed 10 to the minus 8th W/sq cm/ster. From such radiance measurements, it was concluded that the thrustor background radiation should not interfere with the control functions of a star tracker viewing through the thrustor exhaust, provided that the tracker is designed to operate with a sufficiently small field of view. Problems may be encountered, however, during the spacecraft acquisition phase where a larger field of view may be required. Here the thrustor exhaust radiation may be comparable to the star light flux. This problem may be circumvented by locating the tracker view axis so as not to view downstream of the thrustor.

Milder, N. L.↗

Evaluation of radiation dose and image quality of CT scan for whole-body pediatric PET/CT: A phantom study

Purpose: This study aimed to tailor the CT imaging protocols for pediatric patients undergoing whole-body PET/CT examinations with appropriate attention to radiation exposure while maintaining adequate image quality for anatomic delineation of PET findings and attenuation correction of PET emission data. Methods: The measurements were made by using three anthropomorphic phantoms representative of 1-, 5-, and 10-year-old children with tube voltages of 80, 100, and 120 kVp, tube currents of 10, 40, 80, and 120 mA, and exposure time of 0.5 s at 1.75:1 pitch. Radiation dose estimates were derived from the dose-length product and were used to calculate risk estimates for radiation-induced cancer. The influence of image noise on image contrast and attenuation map for CT scans were evaluated based on Pearson's correlation coefficient and covariance, respectively. Multiple linear regression methods were used to investigate the effects of patient age, tube voltage, and tube current on radiation-induced cancer risk and image noise for CT scans. Results: The effective dose obtained using three anthropomorphic phantoms and 12 combinations of kVp and mA ranged from 0.09 to 4.08 mSv. Based on our results, CT scans acquired with 80 kVp/60 mA, 80 kVp/80 mA, and 100 kVp/60 mA could be performed on 1-, 5-, and 10-year-old children, respectively, to minimize cancer risk due to CT scans while maintaining the accuracy of attenuation map and CT image contrast. The effective doses of the proposed protocols for 1-, 5- and 10-year-old children were 0.65, 0.86, and 1.065 mSv, respectively. Conclusions: Low-dose pediatric CT protocols were proposed to balance the tradeoff between radiation-induced cancer risk and image quality for patients ranging in age from 1 to 10 years old undergoing whole-body PET/CT examinations.

60 APPLIED LIFE SCIENCES↗