Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION INTENSITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

University of Miami G-band Vapor Radiometer Calibration (UMGVR_CAL) Field Campaign Report

Cold-air outbreak (CAO) clouds in the Arctic are commonly mixed-phase (MP); however, the partitioning of the amount of ice and water in CAO clouds and precipitation is not always well observed. Understanding how cloud phases partition as a function of cloud life cycle is important for predicting snowfall rates, convective life cycle, and intensity at weather timescales. The partitioning into liquid versus ice also has radiative impacts that are consequential for climate. These concerns motivated the incorporation of an airborne G-band vapor radiometer (GVR) into an National Science Foundation-supported aircraft campaign named the Cold Air outbreak Experiment in the Sub-Arctic Region (CAESAR). The GVR is an upward-pointing passive microwave radiometer using four frequencies centered around the 183.31 GHz water vapor absorption line, displaced by +- 1, 3, 7, and 14 GHz. For context, The U.S. Department of Energy (DOE)’s Atmospheric Radiation Measurement (ARM) user facility operates a surface-based GVR at its North Slope of Alaska (NSA) site. The same GVR has been used previously for a field campaign in the southeast Pacific, where an offset was noticed between brightness temperatures (Tbs) measured under clear skies compared to those calculated from a radiative transfer model. To account for any calibration offsets to the Tbs, a request was made to DOE to allow the GVR to operate at ARM’s Southern Great Plains (SGP) observatory and enable comparisons between its measurements and those available at SGP. This request was granted, titled ‘UMGVR_CAL’, short for ‘UMGVR_Calibration’. From October 30 to November 10, 2023, the GVR was deployed to the ARM SGP site to take advantage of their regular, nearby radiosonde launches under clear-sky conditions. The latter were determined using the SGP total sky imagery data. The GVR brightness temperatures in these clear-sky conditions were compared to those calculated by a radiative transfer code (PAMTRA) based on the SGP radiosondes. During the campaign, four suitable clear-sky episodes could be used for the GVR calibration. While few in number, these proved to be enough to satisfy our goal.

54 ENVIRONMENTAL SCIENCES↗

Energy and Carbon Payback Times for Modern U.S. Utility Photovoltaic Systems

Manufacturing and operating a PV system consumes non-renewable energy and produces carbon emissions, as does end-of-life handling when PV systems are eventually decommissioned. To fully account for PV's contribution toward decarbonization, these life cycle impacts must be quantified. A 2023 NREL LCA of utility PV systems in the United States Study show energy payback times between 0.5 and 1.2 years and carbon payback times between 0.8 to 20 years, depending on the system install location. Payback times are affected by the amount of local solar radiation, and carbon payback time is significantly affected by the carbon-intensity of the local grid it offsets, as well as the future projected grid mix for the location it is installed. In an average U.S. location, carbon payback times are less than 2 years.

carbon payback time↗

Modeling Radiation-Induced Epithelial Cell Injury in Murine Three-Dimensional Esophageal Organoids

Esophageal squamous cell carcinoma (ESCC) is a deadly consequence of radiation exposure to the esophagus. ESCC arises from esophageal epithelial cells that undergo malignant transformation and features a perturbed squamous cell differentiation program. Understanding the dose- and radiation quality-dependence of the esophageal epithelium response to radiation may provide insights into the ability of radiation to promote ESCC. We have explored factors that may play a role in esophageal epithelial radiosensitivity and their potential relationship to ESCC risk. We have utilized a murine three-dimensional (3D) organoid model that recapitulates the morphology and functions of the stratified squamous epithelium of the esophagus to study persistent dose- and radiation quality-dependent changes. Interestingly, although high-linear energy transfer (LET) Fe ion exposure induced a more intense and persistent alteration of squamous differentiation and 53BP1 DNA damage foci levels as compared to Cs, the MAPK/SAPK stress pathway signaling showed similar altered levels for most phospho-proteins with both radiation qualities. In addition, the lower dose of high-LET exposure also revealed nearly the same degree of morphological changes, even though only ~36% of the cells were predicted to be hit at the lower 0.1 Gy dose, suggesting that a bystander effect may be induced. Although p38 and ERK/MAPK revealed the highest levels following high-LET exposure, the findings reveal that even a low dose (0.1 Gy) of both radiation qualities can elicit a persistent stress signaling response that may critically impact the differentiation gradient of the esophageal epithelium, providing novel insights into the pathogenesis of radiation-induced esophageal injury and early stage esophageal carcinogenesis.

3D organoid culture↗

Hadron-Induced Radiation Damage in Fast Heavy Inorganic Scintillators

Fast and heavy inorganic scintillators with suitable radiation tolerance are required to face the challenges presented at future hadron colliders of high energy and intensity. Up to 5 GGy and 5 × 1018 neq/cm2 of one-MeV-equivalent neutron fluence is expected by the forward calorimeter at the Future Hadron Circular Collider. This paper reports the results of an investigation of proton- and neutron-induced radiation damage in various fast and heavy inorganic scintillators, such as LYSO:Ce crystals, LuAG:Ce ceramics, and BaF2 crystals. The experiments were carried out at the Blue Room with 800 MeV proton fluence up to 3.0 × 1015 p/cm2 and at the East Port with one MeV equivalent neutron fluence up to 9.2 × 1015 neq/cm2, respectively, at the Los Alamos Neutron Science Center. Experiments were also carried out at the CERN PS-IRRAD proton facility with 24 GeV proton fluence up to 8.2 × 1015 p/cm2. Research and development will continue to develop LuAG:Ce ceramics and BaF2:Y crystals with improved optical quality, F/T ratio, and radiation hardness.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Total absorption spectroscopy measurement on neutron-rich 74,75 Cu isotopes

This paper reports on the first β-decay study of 74,75 Cu isotopes using the technique of total absorption spectroscopy (TAS). The experiment was performed at the National Superconducting Cyclotron Laboratory at Michigan State University using the Summing NaI(Tl) (SuN) detector. The Cu isotopes are good candidates to probe the single-particle structure in the region because they have one proton outside the Z = 28 shell. Comparing the β-decay intensity distributions in the daughter Zn isotopes to the theoretical predictions provides a stringent test of the calculations. The nuclei in this region are also identified as playing an important role in the astrophysical r-process. Furthermore, the measured β-decay intensity distributions provide essential nuclear physics inputs required to better understand heavy element nucleosynthesis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Enhanced radiative and thermal properties from surface encapsulation of InAs nanowires

In this work, photoluminescence (PL), quantum efficiency and carrier dynamics are investigated in indium arsenide (InAs) nanowires (NWs) with various surface treatments, including a molecular beam epitaxy (MBE)-grown semiconductor shell passivation, sulfur-passivation, alumina (Al 2 O 3 ) coating by atomic layer deposition (ALD) and polydimethylsiloxane (PDMS) spin-coating. The ALD-dielectric layer-coated InAs core-shell NWs show a maximum 13-fold increase in PL intensity. In contrast to the previous reports, this enhancement is found to be due to increased radiative rate from an enhanced Purcell factor, better thermal conductance and higher carrier injection within the NWs instead of improved surface quality. Numeric simulations confirm the experimentally observed increased radiative rate. Further improvements are suggested with even thicker capped InAs NWs. Carrier lifetime in surface-treated NWs is extended and shows long-term stability, critical for practical devices.

36 MATERIALS SCIENCE↗

Examination of Radiation Belt Dynamics During Substorm Clusters: Activity Drivers and Dependencies of Trapped Flux Enhancements

Here, dynamical variations of radiation belt trapped electron fluxes are examined to better understand the variability of enhancements linked to substorm clusters. Analysis is undertaken using the Substorm Onsets and Phases from Indices of the Electrojet substorm cluster algorithm for event detection. Observations from low earth orbit are complemented by additional measurements from medium earth orbit to allow a major expansion in the energy range considered, from medium energy energetic electrons up to ultra-relativistic electrons. The number of substorms identified inside a cluster does not depend strongly on solar wind drivers or geomagnetic indices either before, during, or after the cluster start time. Clusters of substorms linked to moderate (100 nT < AE ≤ 300 nT) or strong AE (AE ≥ 300 nT) disturbances are associated with radiation belt flux enhancements, including up to ultra-relativistic energies by the strongest substorms (as measured by strong southward Bz and high AE). These clusters reliably occur during times of high speed solar winds streams with associated increased magnetospheric convection. However, substorm clusters associated with quiet AE disturbances (AE ≤ 100 nT) lead to no significant chorus whistler mode intensity enhancements, or increases in energetic, relativistic, or ultra-relativistic electron flux in the outer radiation belts. In these cases the solar wind speed is low, and the geomagnetic Kp index indicates a lack of magnetospheric convection. Our study clearly indicates that clusters of substorms occurring outside of high speed wind streams are not by themselves sufficient to drive acceleration, which may be due to the lack of pre-cluster convection.

79 ASTRONOMY AND ASTROPHYSICS↗

AI-driven neutrino diagnostics and radiation-hard beam instrumentation for next-generation neutrino experiments

The Long Baseline Neutrino Facility (LBNF) at Fermilab will deliver a high-intensity, multi-megawatt neutrino beam to the Deep Underground Neutrino Experiment (DUNE), enabling precision tests of the three-neutrino paradigm, CP violation searches, neutrino mass ordering determination, and supernova neutrino studies. To accelerate DUNE’s physics reach and ensure robust beam operations, we propose an integrated AI-driven framework with real-time diagnostics and radiation-hardened instrumentation. At its core is a Real-Time Beam Integrity Monitor using a physics-informed Digital Twin. By reconstructing pion phase space from muon profiles and exploiting magnetic horn optic linearity, it enables spill-by-spill beam correction and flux stabilization. By using this approach, flux-related systematics could be reduced from 5% to 1%, potentially accelerating the discovery of CP violations by four to six years. Complementing this, a US–Japan R&D effort will deploy a LAPPD-based muon monitor in the NuMI beamline. ToF measurements can be acquired with picosecond precision using this radiation-hard system, enhancing sensitivity to horn chromatic effects. Simulations confirm strong response to these effects. ML models predict beam quality and horn current to sub-percent accuracy from muon data, enhancing anomaly detection and stability. This scalable, AI-enabled strategy improves beam fidelity, reduces systematics, and sets a new standard for high-power accelerator operations.

Ganguly, Sudeshna [Fermilab] (ORCID:00000003163482↗

AI-driven neutrino diagnostics and radiation-hard beam instrumentation for next-generation neutrino experiments

The Long Baseline Neutrino Facility (LBNF) at Fermilab will deliver a high-intensity, multi-megawatt neutrino beam to the Deep Underground Neutrino Experiment (DUNE), enabling precision tests of the three-neutrino paradigm, CP violation searches, neutrino mass ordering determination, and supernova neutrino studies. To accelerate DUNE’s physics reach and ensure robust beam operations, we propose an integrated AI-driven framework with real-time diagnostics and radiation-hardened instrumentation. At its core is a Real-Time Beam Integrity Monitor using a physics-informed Digital Twin. By reconstructing pion phase space from muon profiles and exploiting magnetic horn optic linearity, it enables spill-by-spill beam correction and flux stabilization. By using this approach, flux-related systematics could be reduced from 5% to 1%, potentially accelerating the discovery of CP violations by four to six years. Complementing this, a US–Japan R&D effort will deploy a LAPPD-based muon monitor in the NuMI beamline. ToF measurements can be acquired with picosecond precision using this radiation-hard system, enhancing sensitivity to horn chromatic effects. Simulations confirm strong response to these effects. ML models predict beam quality and horn current to sub-percent accuracy from muon data, enhancing anomaly detection and stability. This scalable, AI-enabled strategy improves beam fidelity, reduces systematics, and sets a new standard for high-power accelerator operations.

Ganguly, Sudeshna [Fermilab] (ORCID:00000003163482↗

Bayesian optimization to design a novel x-ray shaping device

In radiation therapy, x-ray dose must be precisely sculpted to the tumor, while simultaneously avoiding surrounding organs at risk. This requires modulation of x-ray intensity in space and/or time. Typically, this is achieved using a multi leaf collimator (MLC) - a complex mechatronic device comprising over one hundred individually powered tungsten ‘leaves’ that move in or out of the radiation field as required. Here, an all-electronic x-ray collimation concept with no moving parts is presented, termed “SPHINX”: Scanning Pencil-beam High-speed Intensity-modulated X-ray source. SPHINX utilizes a spatially distributed bremsstrahlung target and collimator array in conjunction with magnetic scanning of a high energy electron beam to generate a plurality of small x-ray “beamlets.” A simulation framework was developed in Topas Monte Carlo incorporating a phase space electron source, transport through user defined magnetic fields, bremsstrahlung x-ray production, transport through a SPHINX collimator, and dose in water. This framework was completely parametric, meaning a simulation could be built and run for any supplied geometric parameters. This functionality was coupled with Bayesian optimization to find the best parameter set based on an objective function which included terms to maximize dose rate for a user defined beamlet width while constraining inter-channel cross talk and electron contamination. Designs for beamlet widths of 5, 7, and 10 mm 2 were generated. Each optimization was run for 300 iterations and took approximately 40 h on a 24-core computer. For the optimized 7-mm model, a simulation of all beamlets in water was carried out including a linear scanning magnet calibration simulation. Finally, a back-of-envelope dose rate formalism was developed and used to estimate dose rate under various conditions. The optimized 5–, 7–, and 10-mm models had beamlet widths of 5.1 , 7.2 , and 10.1 mm 2 and dose rates of 3574, 6351, and 10 015 Gy/C, respectively. The reduction in dose rate for smaller beamlet widths is a result of both increased collimation and source occlusion. For the simulation of all beamlets in water, the scanning magnet calibration reduced the offset between the collimator channels and beam centroids from 2.9 ±1.9 mm to 0.01 ±0.03 mm. A slight reduction in dose rate of approximately 2% per degree of scanning angle was observed. Based on a back-of-envelope dose rate formalism, SPHINX in conjunction with next-generation linear accelerators has the potential to achieve substantially higher dose rates than conventional MLC-based delivery, with delivery of an intensity modulated 100 x 100 mm 2 field achievable in 0.9 to 10.6 s depending on the beamlet widths used. Bayesian optimization was coupled with Monte Carlo modeling to generate SPHINX geometries for various beamlet widths. A complete Monte Carlo simulation for one of these designs was developed, including electron beam transport of all beamlets through scanning magnets, x-ray production and collimation, and dose in water. These results demonstrate that SPHINX is a promising candidate for sculpting radiation dose with no moving parts, and has the potential to vastly improve both the speed and robustness of radiotherapy delivery. A multi-beam SPHINX system may be a candidate for delivering magavoltage FLASH RT in humans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of a hardened THz energy meter for use on the kilojoule-scale, short-pulse OMEGA EP laser

A highly adaptable and robust terahertz (THz) energy meter is designed and implemented to detect energetic THz pulses from high-intensity (>10 18 W/cm 2 ) laser–plasma interactions on the OMEGA EP. THz radiation from the laser driven target is detected by a shielded pyrometer. A second identical pyrometer is used for background subtraction. The detector can be configured to detect THz pulses in the 1 mm to 30 μm (0.3- to 10-THz) range and pulse energies from joules to microjoules via changes in filtration, aperture size, and position. Additional polarization selective filtration can also be used to determine the THz pulse polarization. The design incorporates significant radiation and electromagnetic pulse shielding to survive and operate within the OMEGA EP radiation environment. We describe the design, operational principle, calibration, and testing of the THz energy meter. The pyrometers were calibrated using a benchtop laser and show linear sensitivity to up to 1000 nJ of absorbed energy. Furthermore, the initial results from four OMEGA EP THz experiments detected up to ~15 μJ at the detector, which can correspond to hundreds of mJ depending on THz emission and reflection models.

47 OTHER INSTRUMENTATION↗

Study of Stark broadening of krypton helium-$\beta$ lines and estimation of electron density and temperature in NIF compressed capsules

Here the National Ignition Facility (NIF) diagnostic instrument manipulator (DIM) - based high resolution (dHIRES) x-ray spectrometer was used to measure the time evolution of the electron density (n e ) and temperature (T e ) in the hot spot of four NIF compressed capsules with 25 ps time resolution during the 'stagnation' phase. The electron density was inferred by comparing the measured Stark broadening of the krypton (Kr) Heβ spectral complex with theoretical calculations that include ion dynamic effects, and the electron temperature was inferred by comparing the measured ratio of the intensity of a dielectronically excited Li-like Kr line to the intensity of the Kr Heβ resonance line with calculations using the spectroscopic collisional radiative atomic model (SCRAM) and CRETIN collisional-radiative models. The inferred, time averaged n e values mainly agree with n e values from neutron diagnostics within uncertainties, but the neutron time-of-flight values of T ion are consistently higher than dHIRES T e values by 200–700 eV. The dHIRES measurements and measurement techniques, method of uncertainty analysis, and discussion of comparisons with measurements from neutron diagnostics are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Aerosol Optical Properties as Part of the Long-Term Aerosol Measurements in Puerto Rico (AOP-LAMP) Field Campaign Report

The University of Puerto Rico-Rio Piedras Campus (UPR-RP) has been measuring aerosol optical, chemical, and microphysical properties at Cape San Juan (CSJ, also known as CPR) since 2004. This site has also hosted several intensive field campaigns, with context provided by the long-term measurements. Hurricane Maria largely destroyed the station on September 20, 2017, forcing a cessation of the measurements. The scientific focus of this intensive operational period was to use a U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Mobile Facility (AMF) aerosol shelter to enable the resumption of long-term aerosol measurements. This AMF shelter is now the main aerosol shelter for CSJ operations.

54 ENVIRONMENTAL SCIENCES↗

Retrieval of temperature and humidity profiles from ground-based high-resolution infrared observations using an adaptive fast iterative algorithm

Various retrieval algorithms have been developed for retrieving temperature and water vapor profiles from Atmospheric Emitted Radiance Interferometer (AERI) observations. The physical retrieval algorithm, named AERI Optimal Estimation (AERIoe), outperforms other retrieval algorithms in many aspects except the retrieval time, which is significantly increased due to the complex radiative transfer process. The calculation of the Jacobian matrix is the most computationally intensive step of the physical retrieval algorithm. Interestingly, an analysis of the change in AERI observations' information content with respect to Jacobians revealed that the AERIoe algorithm's performance presents negligible dependence on these metrics. Thus, the Jacobian matrix could remain unchanged when the variation in the atmospheric state is small in the retrieval process to reduce the most time-consuming computation. On the basis of the above findings, a fast physical–iterative retrieval algorithm was proposed by adaptively recalculating Jacobians in keeping with the changes in the atmospheric state. Experiments with synthetic observations demonstrate that the proposed method experiences an average reduction in retrieval time by an impressive 59 % compared to the original AERIoe algorithm while achieving maximum root-mean-square errors of less than 0.95 K and 0.22 log(ppmv) for heights below 3 km for the temperature and water vapor profile, respectively. Further analyses revealed that the fast-retrieval algorithm reached an acceptable convergence rate of 98.7 %, marginally lower than AERIoe's 99.9 % convergence rate for the 826 cases used in this study.

54 ENVIRONMENTAL SCIENCES↗

Photoionization of the I 4d and valence orbitals of methyl iodide

Here, the photoabsorption and photoionization dynamics of the I 4d and valence orbitals in methyl iodide have been studied both experimentally and theoretically. Synchrotron radiation has been employed to measure the total ion yield in the vicinity of the I 4d ionization thresholds. The observed structure, due to excitations into Rydberg or valence states, has been assigned using transition energies and relative intensities computed with time-dependent density functional theory within the Tamm–Dancoff approximation. Photoelectron spectra, recorded with plane polarized radiation in two polarization geometries, have allowed the effect of autoionization on the valence electron angular distributions to be investigated. The spectra obtained at photon energies of 50.62 and 52.34 eV, coinciding respectively with the I 4d 5/2 → σ* and 4d 3/2 → σ* transitions, reveal, in addition to valence shell photoelectron bands, features not associated with simple photoionization of the parent molecule. High resolution photoelectron spectra of the I 4d main-lines display structure resulting from spin–orbit coupling and molecular field splitting. The binding energies of the five states contributing to the (I 4d) -1 ionization have been determined. The iodine (in CH 3 I) N 45 VV Auger spectrum has been measured and the observed structure has been assigned using the core hole binding energies derived in the present work together with established ionization energies of the doubly charged ion. The experimentally determined Auger electron angular distributions have been discussed in relation to the theoretical angular distribution parameter characterizing the spatial alignment of molecular axes in the (I 4d) -1 state.

74 ATOMIC AND MOLECULAR PHYSICS↗

Evaluation of radiation hardness of semiconductor materials against alpha particles for an API detector

An Associated Particle Imaging (API) system consists of a high vacuum chamber where deuterium ions are accelerated on a tritium-loaded target, resulting in alpha particles and neutrons emitted back-to-back, the latter escaping the chamber and used, for example, for tomography of a high-Z sample. An accurate determination of the alpha position is crucial to determine the trajectory of the neutron. Existing API systems have several limitations which a semiconductor-based API detector placed inside the vacuum chamber should not present. The semiconductor material can be either silicon or diamond. In particular, large and fast signals are generated by the alpha interactions in these materials. A pixelated API detector will measure the time and hit position of the alphas produced in the reaction. However, during the lifetime of the generator, the semiconductor detector will be exposed to an intense flux of alpha particles that will degrade its performance over time. To assess the radiation hardness of silicon and diamond against the alpha particles, we exposed single diodes made of either of the two materials to a 5 MeV alpha flux generated by an 241Am radioactive source. During irradiation, the diodes were biased and mounted on current-sensitive preamplifier boards. We have therefore been able to measure insitu the evolution of the waveforms as the damage was accumulating in their substrates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Theoretical level energies, radiative lifetimes and transitions in W IX

The atomic states of the W IX (W{sup 8+}) tungsten ion lying below the W{sup 9+} ionisation threshold have been studied theoretically, employing the multiconfiguration Dirac–Hartree–Fock method with configuration interaction. The level electronic structures and their energies are presented. The electric dipole (E1), magnetic dipole (M1), electric quadrupole (E2), and magnetic quadrupole (M2) radiative transitions have been computed in order to calculate the radiative lifetimes of given states. Transition wavelengths, energies, and decay rates are also presented for selected high-intensity E1 transitions. The configuration interaction method was applied to estimate electron correlation effects. The aim of the present research was to fill a lack of atomic data for low-charged tungsten ions, which may be useful in low-temperature plasma diagnostics and may form the base for collisional–radiative modelling of spectra for low-charged tungsten ions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A development of wide dynamic-range halo monitor for 8 GeV proton beams at FNAL

The FNAL accelerator complex has been upgrading in increasing beam intensity and beam quality. A new beam halo diagnostic device is required in the beam transport line between booster and Recycler. For this purpose, it was decided to introduce the wide dynamic range monitor technique that was developed in 2012 and has been in operation at the J-PARC beam transport line. The device is a two-dimensional beam profile monitor, and it has a dynamic range of approximately six digits of magnitude by using of Optical Transition Radiation and fluorescence screens. Eliminating harmful beam halos is the most important technique for high-intensity proton accelerators. Therefore, beam halo diagnosis is indispensable and becomes more and more important. New FNAL device has been manufactured in a collaboration between J-PARC and FNAL as a part of U.S.-Japan Science and Technology Cooperation Program in High Energy Physics. The equipment will be manufactured at J-PARC and will be shipped to FNAL in 2025.We designed the device to satisfy FNAL specifications: the beam energy, intensity, and size. Currently, most of the equipments are under construction. The large-aperture optical system has been completed and its optical characteristics are being evaluated at J-PARC. We have been also investigating measurement methods corresponding to FNAL bunch trains. This paper reports on the current status of these developments.

43 PARTICLE ACCELERATORS↗