Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION DISTRIBUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

THE GALACTIC BULGE SURVEY: OUTLINE AND X-RAY OBSERVATIONS

We introduce the Galactic Bulge Survey (GBS) and we provide the Chandra source list for the region that has been observed to date. Among the goals of the GBS are constraining the neutron star (NS) equation of state and the black hole (BH) mass distribution via the identification of eclipsing NS and BH low-mass X-ray binaries (LMXBs). The latter goal will, in addition, be obtained by significantly enlarging the number of BH systems for which a BH mass can be derived. Further goals include constraining X-ray binary formation scenarios, in particular the common envelope phase and the occurrence of kicks, via source-type number counts and an investigation of the spatial distribution of X-ray binaries, respectively. The GBS targets two strips of 6{sup 0} x 1{sup 0} (12 deg{sup 2} in total), one above (1{sup 0} < b < 2{sup 0}) and one below (-2{sup 0} < b < -1{sup 0}) the Galactic plane in the direction of the Galactic center at both X-ray and optical wavelengths. By avoiding the Galactic plane (-1{sup 0} < b < 1{sup 0}) we limit the influence of extinction on the X-ray and optical emission but still sample relatively large number densities of sources. The survey is designed such that a large fraction of the X-ray sources can be identified from their optical spectra. The X-ray survey, by design, covers a large area on the sky while the depth is shallow using 2 ks per Chandra pointing. In this way we maximize the predicted number ratio of (quiescent) LMXBs to cataclysmic variables. The survey is approximately homogeneous in depth to a 0.5-10 keV flux of 7.7 x 10{sup -14} erg cm{sup -2} s{sup -1}. So far, we have covered about two-thirds (8.3 deg{sup 2}) of the projected survey area with Chandra providing over 1200 unique X-ray sources. We discuss the characteristics and the variability of the brightest of these sources.

79 ASTRONOMY AND ASTROPHYSICS↗

Beamed microwave power transmitting and receiving subsystems radiation characteristics

Measured characteristics of the spectrum of typical converters and the distribution of radiated Radio Frequency (RF) energy from the terminals (transmitting antenna and rectenna) of a beamed microwave power subsystem are presented for small transmitting and receiving S-band (2.45 GHz) subarrays. Noise and harmonic levels of tube and solid-state RF power amplifiers are shown. The RF patterns and envelope of a 64 element slotted waveguide antenna are given for the fundamental frequency and harmonics through the fifth. Reflected fundamental and harmonic patterns through the fourth for a 42 element rectenna subarray are presented for various dc load and illumination conditions. Bandwidth measurements for the waveguide antenna and rectenna are shown.

Dickinson, R. M.↗

A new absolute extreme ultraviolet image system designed for studying the radiated power of the Joint Texas Experimental Tokamak discharges

A bolometer imaging system mounted on different toroidal and poloidal locations used for radiation observation has been developed in the Joint Texas Experimental Tokamak (J-TEXT tokamak). Three miniature pinhole AXUV16ELG (16 elements absolute extreme ultraviolet silicon photodiodes) array cameras, which are settled down in the same toroidal position but in three different poloidal places, can provide a broad viewing angle that covers the whole plasma cross-section, and hence can measure the total radiated power and provide the radiated emissive profile, while nine AXUV10EL (10 elements absolute extreme ultraviolet silicon photodiodes) array cameras are divided into three groups and will be mounted on different toroidal locations to observe the toroidal radiated power distribution. Among these detectors, one element of the AXUV16ELG array is absolutely calibrated by the synchrotron radiation source to verify the system reliability. Although there are some discrepancies between the typical responsivity given by IRD Co. and the calibrated results, it is confirmed that the discrepancies have no major effect on the final result after the simulation. The details of the system as well as observations are presented in the paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In Vivo Proton Beam Range Verification Using Spine MRI Changes

Purpose: In proton therapy, uncertainty in the location of the distal dose edge can lead to cautious treatment plans that reduce the dosimetric advantage of protons. After radiation exposure, vertebral bone marrow undergoes fatty replacement that is visible on magnetic resonance imaging (MRI). This presents an exciting opportunity to observe radiation dose distribution in vivo. We used quantitative spine MRI changes to precisely detect the distal dose edge in proton radiation patients. Methods and Materials: We registered follow-up T1-weighted MRI images to planning computed tomography scans from 10 patients who received proton spine irradiation. A radiation dose-MRI signal intensity curve was created using the lateral beam penumbra in the sacrum. This curve was then used to measure range errors in the lumbar spine. Results: In the lateral penumbra, there was an increase in signal intensity with higher dose throughout the full range of 0-37.5 Gy (RBE). In the distal fall-off region, the beam sometimes appeared to penetrate farther than planned. The mean overshoot in 10 patients was 1.9 mm (95% confidence interval, 0.8-3.1 mm), on the order of the uncertainties inherent to our range verification method. Conclusions: We have demonstrated in vivo proton range verification using posttreatment spine MRI changes. Our analysis suggests the presence of a systematic overshoot of a few millimeters in some proton spine treatments, but the range error does not exceed the uncertainty incorporated into the treatment planning margin. It may be possible to extend our technique to MRI sequences that show early bone marrow changes, enabling adaptive treatment modification.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Surface roughness effects on equilibrium temperature.

An analysis is presented for evaluation of equilibrium temperature distribution on radiatively adiabatic, adjoint planes which are uniformly irradiated by a collimated solar flux. The analysis employs a semigrey spectral model. Radiation properties for surface emitted radiation are obtained from the expressions of electromagnetic theory for smooth surfaces. Rough surface properties for solar radiation are given by the Beckmann bidirectional reflectance model. Numerical solutions to the governing equations yield equilibrium temperature distributions for a range of the influencing parameters. Surface roughness has little influence on equilibrium temperature for materials with high values for solar absorptance. However, for low or intermediate values of solar absorptance, roughness effects on the spatial distribution of reflected solar radiation can significantly alter equilibrium temperature particularly at surface elements where radiant interaction is small.

Houchens, A. F.↗

SU-E-J-274: Responses of Medulloblastoma Cells to Radiation Dosimetric Parameters in Intensity-Modulated Radiation Therapy

Purpose: To evaluate radiation responses of the medulloblastoma cell line Daoy in intensity-modulated radiation therapy (IMRT), quantitative variations to variable radiation dosimetic parameters were tracked by bioluminescent images (BLIs). Methods: The luciferase and green fluorescent protein positive Daoy cells were cultured on dishes. The medulloblastoma cells irradiated to different dose rate, interval of fractionated doses, field margin and misalignment, and dose uniformity in IMRT were monitored using bioluminescent images. The cultured cells were placed into a dedicated acrylic phantom to deliver intensity-modulated fluences and calculate accurate predicted dose distribution. The radiation with dose rate from 0.5 Gy/min to 15 Gy/min was irradiated by adjusting monitor unit per minute and source-to-surface distances. The intervals of fractionated dose delivery were changed considering the repair time of double strand breaks (DSB) revealed by straining of gamma-H2AX.The effect of non-uniform doses on the cells were visualized by registering dose distributions and BLIs. The viability according to dosimetric parameters was correlated with bioluminescent intensities for cross-check of radiation responses. Results: The DSB and cell responses due to the first fractionated dose delivery significantly affected final tumor control rather than other parameters. The missing tumor volumes due to the smaller field margin than the tumor periphery or field misalignment caused relapse of cell responses on BLIs. The dose rate and gradient had effect on initial responses but could not bring out the distinguishable killing effect on cancer cells. Conclusion: Visualized and quantified bioluminescent images were useful to correlate the dose distributions with spatial radiation effects on cells. This would derive the effective combination of dose delivery parameters and fractionation. Radiation responses in particular IMRT configuration could be reflected to image based-dose re-optimization.

60 APPLIED LIFE SCIENCES↗

The Importance of Physical Models for Deriving Dust Masses and Grain Size Distributions in Supernova Ejecta. I. Radiatively Heated Dust in the Crab Nebula

Recent far-infrared (IR) observations of supernova remnants (SNRs) have revealed significantly large amounts of newly condensed dust in their ejecta, comparable to the total mass of available refractory elements. The dust masses derived from these observations assume that all the grains of a given species radiate at the same temperature, regardless of the dust heating mechanism or grain radius. In this paper, we derive the dust mass in the ejecta of the Crab Nebula, using a physical model for the heating and radiation from the dust. We adopt a power-law distribution of grain sizes and two different dust compositions (silicates and amorphous carbon), and calculate the heating rate of each dust grain by the radiation from the pulsar wind nebula. We find that the grains attain a continuous range of temperatures, depending on their size and composition. The total mass derived from the best-fit models to the observed IR spectrum is 0.019-0.13 Solar Mass, depending on the assumed grain composition. We find that the power-law size distribution of dust grains is characterized by a power-law index of 3.5-4.0 and a maximum grain size larger than 0.1 micron. The grain sizes and composition are consistent with what is expected for dust grains formed in a Type IIP supernova (SN). Our derived dust mass is at least a factor of two less than the mass reported in previous studies of the Crab Nebula that assumed more simplified two-temperature models. These models also require a larger mass of refractory elements to be locked up in dust than was likely available in the ejecta. The results of this study show that a physical model resulting in a realistic distribution of dust temperatures can constrain the dust properties and affect the derived dust masses. Our study may also have important implications for deriving grain properties and mass estimates in other SNRs and for the ultimate question of whether SNe are major sources of dust in the Galactic interstellar medium and in external galaxies.

Importance↗

THE IMPORTANCE OF PHYSICAL MODELS FOR DERIVING DUST MASSES AND GRAIN SIZE DISTRIBUTIONS IN SUPERNOVA EJECTA. I. RADIATIVELY HEATED DUST IN THE CRAB NEBULA

Recent far-infrared (IR) observations of supernova remnants (SNRs) have revealed significantly large amounts of newly condensed dust in their ejecta, comparable to the total mass of available refractory elements. The dust masses derived from these observations assume that all the grains of a given species radiate at the same temperature, regardless of the dust heating mechanism or grain radius. In this paper, we derive the dust mass in the ejecta of the Crab Nebula, using a physical model for the heating and radiation from the dust. We adopt a power-law distribution of grain sizes and two different dust compositions (silicates and amorphous carbon), and calculate the heating rate of each dust grain by the radiation from the pulsar wind nebula. We find that the grains attain a continuous range of temperatures, depending on their size and composition. The total mass derived from the best-fit models to the observed IR spectrum is 0.019-0.13 M{sub Sun }, depending on the assumed grain composition. We find that the power-law size distribution of dust grains is characterized by a power-law index of 3.5-4.0 and a maximum grain size larger than 0.1 {mu}m. The grain sizes and composition are consistent with what is expected for dust grains formed in a Type IIP supernova (SN). Our derived dust mass is at least a factor of two less than the mass reported in previous studies of the Crab Nebula that assumed more simplified two-temperature models. These models also require a larger mass of refractory elements to be locked up in dust than was likely available in the ejecta. The results of this study show that a physical model resulting in a realistic distribution of dust temperatures can constrain the dust properties and affect the derived dust masses. Our study may also have important implications for deriving grain properties and mass estimates in other SNRs and for the ultimate question of whether SNe are major sources of dust in the Galactic interstellar medium and in external galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

THE STELLAR AGES AND MASSES OF SHORT GAMMA-RAY BURST HOST GALAXIES: INVESTIGATING THE PROGENITOR DELAY TIME DISTRIBUTION AND THE ROLE OF MASS AND STAR FORMATION IN THE SHORT GAMMA-RAY BURST RATE

We present multi-band optical and near-infrared observations of 19 short {gamma}-ray burst (GRB) host galaxies, aimed at measuring their stellar masses and population ages. The goals of this study are to evaluate whether short GRBs track the stellar mass distribution of galaxies, to investigate the progenitor delay time distribution, and to explore any connection between long and short GRB progenitors. Using single stellar population models we infer masses of log(M{sub *}/M{sub sun}) {approx} 8.8-11.6, with a median of (log(M{sub *}/M{sub sun})) {approx} 10.1, and population ages of {tau}{sub *} {approx} 0.03-4.4 Gyr with a median of ({tau}{sub *}) {approx} 0.3 Gyr. We further infer maximal masses of log(M{sub *}/M{sub sun}) {approx} 9.7-11.9 by assuming stellar population ages equal to the age of the universe at each host's redshift. Comparing the distribution of stellar masses to the general galaxy mass function, we find that short GRBs track the cosmic stellar mass distribution only if the late-type hosts generally have maximal masses. However, there is an apparent dearth of early-type hosts compared to the equal contribution of early- and late-type galaxies to the cosmic stellar mass budget. Similarly, the short GRB rate per unit old stellar mass appears to be elevated in the late-type hosts. These results suggest that stellar mass may not be the sole parameter controlling the short GRB rate, and raise the possibility of a two-component model with both mass and star formation playing a role (reminiscent of the case for Type Ia supernovae). If short GRBs in late-type galaxies indeed track the star formation activity, the resulting typical delay time is {approx}0.2 Gyr, while those in early-type hosts have a typical delay of {approx}3 Gyr. Using the same stellar population models, we fit the broadband photometry for 22 long GRB host galaxies in a similar redshift range and find that they have significantly lower masses and younger population ages, with (log(M{sub *}/M{sub sun})) {approx} 9.1 and ({tau}{sub *}) {approx} 0.06 Gyr, respectively; their maximal masses are similarly lower, (log(M{sub *}/M{sub sun})) {approx} 9.6, and as expected do not track the galaxy mass function. Most importantly, the two GRB host populations remain distinct even if we consider only the star-forming hosts of short GRBs, supporting our previous findings (based on star formation rates and metallicities) that the progenitors of long and short GRBs in late-type galaxies are distinct. Given the much younger stellar populations of long GRB hosts (and hence of long GRB progenitors), and the substantial differences in host properties, we caution against the use of Type I and II designations for GRBs since this may erroneously imply that all GRBs which track star formation activity share the same massive star progenitors.

79 ASTRONOMY AND ASTROPHYSICS↗

Clinical Research Ethics: Considerations for the Radiation Oncologist

Consideration of clinical research ethics in radiation oncology is underexplored relative to other areas of oncology. A number of ethical challenges related to informed consent, randomization, conflicts of interest, and scientific validity and social value are shared with other areas of medicine, although their exact inflections are specific to radiation oncology. In addition, there are unique concerns in radiation oncology arising from the rapid evolution and uneven distribution of radiation technologies; the greater unfamiliarity of the general public and research oversight committees in regard to radiation oncology clinical practice; and the high complexity of managing most radiation oncology research, much of which is carried out in high-acuity multidisciplinary oncologic settings. To produce the best research, adherence to the highest ethical standards should be pursued as an integral component of all radiation oncology research.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Empirical Model of Radiation Belt Electron Pitch Angle Distributions Based On Van Allen Probes Measurements

Based on over 4 years of Van Allen Probes measurements, an empirical model of radiation belt electron equatorial pitch angle distribution (PAD) is constructed. The model, developed by fitting electron PADs with Legendre polynomials, provides the statistical PADs as a function of L-shell (L = 1-6), magnetic local time, electron energy (~30 keV to 5.2 MeV), and geomagnetic activity (represented by the Dst index) and is also the first empirical PAD model in the inner belt and slot region. For megaelectron volt electrons, model results show more significant day-night PAD asymmetry of electrons with higher energies and during disturbed times, which is caused by geomagnetic field configuration and flux radial gradient changes. Steeper PADs with higher fluxes around 90° pitch angle and lower fluxes at lower pitch angles for higher energy electrons and during active times are also present, which could be due to electromagnetic ion cyclotron wave scattering. For hundreds of kiloelectron volt electrons, cap PADs are generally present in the slot region during quiet times and their energy-dependent features are consistent with hiss wave scattering, while during active times, cap PADs are less significant especially at outer part of slot region, which could be due to the complex energizing and transport processes. The 90°-minimum PADs are persistently present in the inner belt and appear in the slot region during active times, and minima at 90° pitch angle are more significant for electrons with higher energies, which could be a critical evidence in identifying the underlying physical processes responsible for the formation of 90°-minimum PADs.

Zhao, H.↗

Dry cask radiation shielding validation and estimation of cask surface dose rate with MAVRIC during long-term storage

The dry storage cask became a semi-permanent solution for spent nuclear fuel since no permanent solution has been finalized over the past three decades. Considering the difficulty of deep geological repository projects in many aspects, prolonging the service life of dry casks longer than a few decades has become an option for spent nuclear fuel storage. It must be ensured that dry cask safety objectives, including radiation shielding, criticality safety, structure health, decay heat removal, and containment be fulfilled during the prolonged service life. This paper presents numerical modeling results of the radiation dose rate distribution on a TN-32 cask surface aged up to 300 years. The numerical modeling method was validated with measurement data, and the difference between the calculated results and measurement data in the total dose rate is 7%. The detailed radiation distribution variations over cask surfaces along the axial and radial directions for 300 years of storage were obtained, and their azimuthal angular dependence was established. The maximum total dose rate over the cask surfaces is less than 10 mrem/hour (9.258 ± 0.212 mrem/hour) after 40 years, and this outcome fulfills all dose rate requirements from 10 CFR 71.47(b). After 300 years of storage, the average total dose rates on the side surface and top surface are 0.150 ± 0.007mremmrem/hour and 0.057 ± 0.003mremmrem/hour, respectively, while the maxima are 0.601 ± 0.014 mrem/hour and 0.112 ± 0.006 mrem/hour, respectively. The variations in the fuel gamma ray, structure gamma ray, neutron and secondary gamma-ray contributions to the total dose rate are presented and analyzed in this work. The neutron and gamma-ray dose rate contributions by energy group are presented and analyzed at the cask top, mid-plane, and bottom at the selected storage times.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-D-201-07: Exploring the Utility of 4D FDG-PET/CT Scans in Design of Radiation Therapy Planning Compared with 3D PET/CT: A Prospective Study

Purpose: A method using four-dimensional(4D) PET/CT in design of radiation treatment planning was proposed and the target volume and radiation dose distribution changes relative to standard three-dimensional (3D) PET/CT were examined. Methods: A target deformable registration method was used by which the whole patient’s respiration process was considered and the effect of respiration motion was minimized when designing radiotherapy planning. The gross tumor volume of a non-small-cell lung cancer was contoured on the 4D FDG-PET/CT and 3D PET/CT scans by use of two different techniques: manual contouring by an experienced radiation oncologist using a predetermined protocol; another technique using a constant threshold of standardized uptake value (SUV) greater than 2.5. The target volume and radiotherapy dose distribution between VOL3D and VOL4D were analyzed. Results: For all phases, the average automatic and manually GTV volume was 18.61 cm3 (range, 16.39–22.03 cm3) and 31.29 cm3 (range, 30.11–35.55 cm3), respectively. The automatic and manually volume of merged IGTV were 27.82 cm3 and 49.37 cm3, respectively. For the manual contour, compared to 3D plan the mean dose for the left, right, and total lung of 4D plan have an average decrease 21.55%, 15.17% and 15.86%, respectively. The maximum dose of spinal cord has an average decrease 2.35%. For the automatic contour, the mean dose for the left, right, and total lung have an average decrease 23.48%, 16.84% and 17.44%, respectively. The maximum dose of spinal cord has an average decrease 1.68%. Conclusion: In comparison to 3D PET/CT, 4D PET/CT may better define the extent of moving tumors and reduce the contouring tumor volume thereby optimize radiation treatment planning for lung tumors.

60 APPLIED LIFE SCIENCES↗

Fast, high-resolution 3D dosimetry utilizing a novel optical-CT scanner incorporating tertiary telecentric collimation

This study introduces a charge coupled device (CCD) area detector based optical-computed tomography (optical-CT) scanner for comprehensive verification of radiation dose distributions recorded in nonscattering radiochromic dosimeters. Defining characteristics include: (i) a very fast scanning time of {approx}5 min to acquire a complete three-dimensional (3D) dataset, (ii) improved image formation through the use of custom telecentric optics, which ensures accurate projection images and minimizes artifacts from scattered and stray-light sources, and (iii) high resolution (potentially 50 {mu}m) isotropic 3D dose readout. The performance of the CCD scanner for 3D dose readout was evaluated by comparison with independent 3D readout from the single laser beam OCTOPUS-scanner for the same PRESAGE dosimeters. The OCTOPUS scanner was considered the 'gold standard' technique in light of prior studies demonstrating its accuracy. Additional comparisons were made against calculated dose distributions from the ECLIPSE treatment-planning system. Dose readout for the following treatments were investigated: (i) a single rectangular beam irradiation to investigate small field and very steep dose gradient dosimetry away from edge effects, (ii) a 2-field open beam parallel-opposed irradiation to investigate dosimetry along steep dose gradients, and (iii) a 7-field intensity modulated radiation therapy (IMRT) irradiation to investigate dosimetry for complex treatment delivery involving modulation of fluence and for dosimetry along moderate dose gradients. Dose profiles, dose-difference plots, and gamma maps were employed to evaluate quantitative estimates of agreement between independently measured and calculated dose distributions. Results indicated that dose readout from the CCD scanner was in agreement with independent gold-standard readout from the OCTOPUS-scanner as well as the calculated ECLIPSE dose distribution for all treatments, except in regions within a few millimeters of the edge of the dosimeter, where edge artifact is predominant. Agreement of line profiles was observed, even along steep dose gradients. Dose difference plots indicated that the CCD scanner dose readout differed from the OCTOPUSscanner readout and ECLIPSE calculations by {approx}10% along steep dose gradients and by {approx}5% along moderate dose gradients. Gamma maps (3% dose-difference and 3 mm distance-to-agreement acceptance criteria) revealed agreement, except for regions within 5 mm of the edge of the dosimeter where the edge artifact occurs. In summary, the data demonstrate feasibility of using the fast, high-resolution CCD scanner for comprehensive 3D dosimetry in all applications, except where dose readout is required close to the edges of the dosimeter. Further work is ongoing to reduce this artifact.

61 RADIATION PROTECTION AND DOSIMETRY↗

Kalman-like estimation for static distributed systems Antenna shape from radiation measurements

This paper advances an approach to the determination of shape of static distributed systems. It also illustrates the application of the approach to the problems of surface diagnosis of large parabolic reflectors. The estimation methods developed combine in an optimal sense the information from an elliptic model of the structure and from measurements of the structural deflection and of the far-field pattern changes due to the structural deformation. The estimators have a predictor-corrector structure, quite similar to that of a Kalman filter. The system model is first used to obtain a predicted estimate. A correction term is then added to the prediction to obtain the final state estimate. The relative weighting between prediction and correction terms is determined by an estimator gain. As in a Kalman filter, the estimator gain can be expressed in terms of the state estimation error covariance.

Rodriguez, G.↗

Using Complementary Methods of Synchrotron Radiation Powder Diffraction and Pair Distribution Function to Refine Crystal Structures with High Quality Parameters—A Review

Determination of the atomic-scale structures of certain fine-grained minerals using single-crystal X-ray diffraction (XRD) has been challenging because they commonly occur as submicron and nanocrystals in the geological environment. Synchrotron powder diffraction and scattering techniques are useful complementary methods for studying this type of minerals. In this review, we discussed three example studies investigated by combined methods of synchrotron radiation XRD and pair distribution function (PDF) techniques: (1) low-temperature cristobalite; (2) kaolinite; and (3) vernadite. Powder XRD is useful to determine the average structure including unit-cell parameters, fractional atomic coordinates, occupancies and isotropic atomic displacement parameters. X-ray/Neutron PDF methods are sensitive to study the local structure with anisotropic atomic displacement parameters (ADP). The results and case studies suggest that the crystal structure and high-quality ADP values can be obtained using the combined methods. The method can be useful to characterize crystals and minerals that are not suitable for single-crystal XRD.

58 GEOSCIENCES↗