Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “R FACTORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Experimental study of boundary layer transition with elevated freestream turbulence on a heated flat plate

A detailed investigation to document momentum and thermal development of boundary layers undergoing natural transition on a heated flat plate was performed. Experimental results of both overall and conditionally sampled characteristics of laminar, transitional, and low Reynolds number turbulent boundary layers are presented. Measurements were acquired in a low-speed, closed-loop wind tunnel with a freestream velocity of 100 ft/s and zero pressure gradient over a range of freestream turbulence intensities (TI) from 0.4 to 6 percent. The distributions of skin friction, heat transfer rate and Reynolds shear stress were all consistent with previously published data. Reynolds analogy factors for R(sub theta) is less than 2300 were found to be well predicted by laminar and turbulent correlations which accounted for an unheated starting length. The measured laminar value of Reynolds analogy factor was as much as 53 percent higher than the Pr(sup -2/3). A small dependence of turbulent results on TI was observed. Conditional sampling performed in the transitional boundary layer indicated the existence of a near-wall drop in intermittency, pronounced at certain low intermittencies, which is consistent with the cross-sectional shape of turbulent spots observed by others. Non-turbulent intervals were observed to possess large magnitudes of near-wall unsteadiness and turbulent intervals had peak values as much as 50 percent higher than were measured at fully turbulent stations. Non-turbulent and turbulent profiles in transitional boundary layers cannot be simply treated as Blasius and fully turbulent profiles, respectively. The boundary layer spectra indicate predicted selective amplification of T-S waves for TI is approximately 0.4 percent. However, for TI is approximately 0.8 and 1.1 percent, T-S waves are localized very near the wall and do not play a dominant role in transition process.

Sohn, Ki-Hyeon↗

Formation of an internal transport barrier and magnetohydrodynamic activity in experiments with the controlled density of rational magnetic surfaces in the T-10 Tokamak

Results are presented from experiments on the formation of an internal electron transport barrier near the q = 1.5 rational surface in the T-10 tokamak. The experiments were carried out in the regime with off-axis electron cyclotron resonance (ECR) heating followed by a fast plasma current ramp-up. After suppressing sawtooth oscillations by off-axis ECR heating, an internal transport barrier began to form near the q = 1.5 rational surface. In the phase of the current ramp-up, the quality of the transport barrier improved; as a result, the plasma energy confinement time increased 2–2.5 times. The intentionally produced flattening of the profile of the safety factor q(r) insignificantly affected magnetohydrodynamic activity in the plasma column in spite of the theoretical possibility of formation of substantial m/n = 3/2 and 2/1 magnetic islands. Conditions are discussed under which the flattening of the profile of the safety factor q near low-order rational surfaces leads to the formation of either an internal transport barrier or the development of an island magnetic structure induced by tearing modes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nucleon distribution amplitudes and their application to nucleon form factors and the N{yields}{delta} transition at intermediate values of Q{sup 2}

We compare a recent lattice determination of the nucleon distribution amplitudes with other approaches and models. We study the nucleon distribution amplitudes up to twist 6 in next-to-leading conformal spin and we also investigate conformal d-wave contributions to the leading-twist distribution amplitude. With the help of light-cone sum rules one can relate the distribution amplitudes to the form factors of the nucleon or the N{yields}{delta} transition at intermediate values of the momentum transfer. We compare our results with experimental data in the range 1 GeV{sup 2}{<=}Q{sup 2}{<=}10 GeV{sup 2}. Keeping in mind that we are working only in leading order QCD and next-to-leading order QCD corrections might be sizeable, we already obtain a surprisingly good agreement for the nucleon form factors G{sub M}{sup n}, G{sub M}{sup p}, G{sub A}{sup p}, and G{sub T}{sup p} and for the N{yields}{delta} transition form factor ratios R{sub EM} and R{sub SM}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Internal structure of the heavy-light mesons

We compute the radial distributions of the vector and axial charge density as well as of the matter density in the heavy-light mesons on the lattice. The results for the lowest lying static heavy-light mesons and their first excited counterparts are obtained with N{sub f}=2 dynamical quarks of Wilson (clover) type and with the various improved static heavy-quark actions. From these distributions we were able to compute the corresponding charges and slopes of the form factors (i.e. <r{sup 2}>). Those results are presented, and briefly discussed too.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Small fields output factors measurements and correction factors determination for several detectors for a CyberKnife{sup Registered-Sign} and linear accelerators equipped with microMLC and circular cones

Purpose: The use of small photon fields is now an established practice in stereotactic radiosurgery and radiotherapy. However, due to a lack of lateral electron equilibrium and high dose gradients, it is difficult to accurately measure the dosimetric quantities required for the commissioning of such systems. Moreover, there is still no metrological dosimetric reference for this kind of beam today. In this context, the first objective of this work was to determine and to compare small fields output factors (OF) measured with different types of active detectors and passive dosimeters for three types of facilities: a CyberKnife{sup Registered-Sign} system, a dedicated medical linear accelerator (Novalis) equipped with m3 microMLC and circular cones, and an adaptive medical linear accelerator (Clinac 2100) equipped with an additional m3 microMLC. The second one was to determine the k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors introduced in a recently proposed small field dosimetry formalism for different active detectors.Methods: Small field sizes were defined either by microMLC down to 6 Multiplication-Sign 6 mm{sup 2} or by circular cones down to 4 mm in diameter. OF measurements were performed with several commercially available active detectors dedicated to measurements in small fields (high resolution diodes: IBA SFD, Sun Nuclear EDGE, PTW 60016, PTW 60017; ionizing chambers: PTW 31014 PinPoint chamber, PTW 31018 microLion liquid chamber, and PTW 60003 natural diamond). Two types of passive dosimeters were used: LiF microcubes and EBT2 radiochromic films.Results: Significant differences between the results obtained by several dosimetric systems were observed, particularly for the smallest field size for which the difference in the measured OF reaches more than 20%. For passive dosimeters, an excellent agreement was observed (better than 2%) between EBT2 and LiF microcubes for all OF measurements. Moreover, it has been shown that these passive dosimeters do not require correction factors and can then be used as reference dosimeters. Correction factors for the active detectors have then been determined from the mean experimental OF measured by the passive dosimeters.Conclusions: Four sets of correction factors needed to apply the new small field dosimetry formalism are provided for several active detectors. A protocol for small photon beams OF determination based on passive dosimeters measurements has been recently proposed to French radiotherapy treatment centers.

61 RADIATION PROTECTION AND DOSIMETRY↗

Using the Human Systems Simulation Laboratory at Idaho National Laboratory for Safety Focused Research

Under the United States (U.S.) Department of Energy (DOE) Light Water Reactor Sustainability (LWRS) program, researchers at Idaho National Laboratory (INL) have been using the Human Systems Simulation Laboratory (HSSL) to conduct critical safety focused Human Factors research and development (R&D) for the nuclear industry. The LWRS program has the overall objective to develop the scientific basis to extend existing nuclear power plant (NPP) operating life beyond the current 60-year licensing period and to ensure their long-term reliability, productivity, safety, and security. One focus area for LWRS is the NPP main control room (MCR), because many of the instrumentation and control (I&C) system technologies installed in the MCR, while highly reliable and safe, are now difficult to replace and are therefore limiting the operating life of the NPP. This paper describes how INL researchers use the HSSL to conduct Human Factors R&D on modernizing or upgrading these I&C systems in a step-wise manner, and how the HSSL has addressed a significant gap in how to upgrade systems and technologies that are built to last, and therefore require careful integration of analog and new advanced digital technologies.

99 GENERAL AND MISCELLANEOUS↗

Dependence of Yb-169 absorbed dose energy correction factors on self-attenuation in source material and photon buildup in water

Purpose: Absorbed dose energy correction factors, used to convert the absorbed dose deposited in a LiF thermoluminescent dosimeter (TLD) into the clinically relevant absorbed dose to water, were obtained for both spherical volumetric sources and for the model 4140 HDR Yb-169 source. These correction factors have a strong energy dependence below 200 keV; therefore, spectral changes were quantified as Yb-169 photons traveled through both source material (Yb{sub 2}O{sub 3}) and water with the corresponding absorbed dose energy correction factors, f(r,{theta}), calculated as a function of location in a phantom. Methods: Using the MCNP5 Monte Carlo radiation transport simulation program, the Yb-169 spectrum emerging from spherical Yb{sub 2}O{sub 3} sources (density 6.9 g/cm{sup 3}) with radii between 0.2 and 0.9 mm were analyzed and their behavior compared against those for a point-source. The absorbed dose deposited to both LiF and H{sub 2}O materials was analyzed at phantom depths of 0.1-10 cm for each source radius and the absorbed dose energy correction factor calculated as the ratio of the absorbed dose to water to that of LiF. Absorbed dose energy correction factors for the Model 4140 Yb-169 HDR brachytherapy source similarly were obtained and compared against those calculated for the Model M-19 Ir-192 HDR source. Results: The Yb-169 average spectral energy, emerging from Yb{sub 2}O{sub 3} spherical sources 0.2-0.9 mm in radius, was observed to harden from 7% to 29%; as these photons traveled through the water phantom, the photon average energy softened by as much as 28% at a depth of 10 cm. Spectral softening was dependent on the measurement depth in the phantom. Energy correction factors were found to vary both as a function of source radius and phantom depth by as much as 10% for spherical Yb{sub 2}O{sub 3} sources. The Model 4140 Yb-169 energy correction factors depended on both phantom depth and reference angle and were found to vary by more than 10% between depths of 1 and 10 cm and angles of 0 deg. and 180 deg. This was in contrast to that of the Model M-19 Ir-192 source which exhibited approximately 3.5%-4.4% variation in its energy correction factors from phantom depths of 0.5-10 cm. The absorbed dose energy correction factor for the Ir-192 source, on the other hand, was independent of angle to within 1%. Conclusions: The application of a single energy correction factor for Yb-169 TLD based dosimetry would introduce a high degree of measurement uncertainty that may not be reasonable for the clinical characterization of a brachytherapy source; rather, an absorbed dose energy correction function will need to be developed for these sources. This correction function should be specific to each source model, type of TLD used, and to the experimental setup to obtain accurate and precise dosimetric measurements.

61 RADIATION PROTECTION AND DOSIMETRY↗

Beyond the effectiveness factor: Multi-step reactions with intraparticle diffusion limitations

Though common in many industrial chemical processes, multi-step reactions occurring within porous catalyst particles provide significant challenges to previously established modeling frameworks. In this work, a system of reaction-diffusion equations is solved analytically via eigenanalysis. The intraparticle concentration profiles are integrated over the particle volume to obtain effectiveness factors for each reacting species, referred to herein as a multi-step effectiveness vector (MEV). The MEV solution is tested for the case of uniform flow past a stationary catalyst particle with a state-of-the-art, multi-step reaction scheme for fluid catalytic cracking (FCC). Outputs from particle-resolved direct numerical simulation (DNS) are compared to outputs from ordinary differentials with effective reaction closures coming from the MEV solution, the classic single-step effectiveness factor (SEF) (R. Aris, 'The mathematical theory of diffusion and reaction in permeable catalysts: The theory of the steady state,' Oxford University Press, 1975), and utilizing the intrinsic rates as-is. When compared to DNS, the MEV solution shows excellent agreement for the formation of all species and quantitatively captures the intraparticle concentration profiles. By contrast, the intrinsic treatment shows an over-prediction for product formation and the SEF treatment shows mixed levels of accuracy that depend upon the reaction coupling. Specifically, the SEF treatment accurately characterizes product formation if the kinetic scheme is weakly coupled but shows significant departure if stronger coupling is present. The computational cost associated with the MEV solution is associated with eigendecomposition of the Thiele matrix, an N x N matrix where N is the number of reacting components. Overall, the method is shown to be relatively easy to implement and may significantly enhance the fidelity of chemical reactor simulations that employ multi-step reaction schemes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

On the interplay between magnetic field and anisotropy in holographic QCD

We investigate the combined effects of anisotropy and a magnetic field in strongly interacting gauge theories by the gauge/gravity correspondence. Our main motivation is the quark-gluon plasma produced in off-central heavy-ion collisions which exhibits large anisotropy in pressure gradients as well as large external magnetic fields. We explore two different configurations, with the anisotropy either parallel or perpendicular to the magnetic field, focusing on the competition and interplay between the two. A detailed study of the RG flow in the ground state reveals a rich structure where depending on which of the two, anisotropy or magnetic field, is stronger, intermediate geometries with approximate AdS 4 × $\mathbb{R}$ and AdS 3 × $\mathbb{R}$ 2 factors arise. This competition is also manifest in the phase structure at finite temperature, specifically in the dependence of the chiral transition temperature on anisotropy and magnetic field, from which we infer the presence of inverse magnetic and anisotropic catalyses of the chiral condensate. Finally, we consider other salient observables in the theory, including the quark-antiquark potential, shear viscosity, entanglement entropy and the butterfly velocity. We demonstrate that they serve as good probes of the theory, in particular, distinguishing between the effects of the magnetic field and anisotropy in the ground and plasma states. We also find that the butterfly velocity, which codifies how fast information propagates in the plasma, exhibits a rich structure as a function of temperature, anisotropy and magnetic field, exceeding the conformal value in certain regimes.

79 ASTRONOMY AND ASTROPHYSICS↗

The iron potassium diarsenate KFeAs{sub 2}O{sub 7} structural, electric and magnetic behaviors

Crystals of a new potassium iron (III) diarsenate (KFeAs{sub 2}O{sub 7}) have been grown and characterized by single crystal X-ray diffraction. It crystallizes in the triclinic space group P1-bar, with a=7.662(1) A, b=8.402(2) A, c=10.100(3) A, {alpha}=90.42(3){sup o}, {beta}=89.74(2){sup o}, {gamma}=106.39(2){sup o}, V=623.8(3) A{sup 3} and Z=4. The final agreement factors are R=0.0342, wR=0.0889, S(F{sup 2})=1.01; the structural model is validated by bond valence sum (BVS) and charge distribution (CD) methods. The structure consists of corner-sharing FeO{sub 6} octahedra and As{sub 2}O{sub 7} diarsenate groups, the three-dimensional framework delimits tunnels running along [0 1 0] direction where the potassium ions reside. The crystal structure of the title compound is different from that of the monoclinic KAlP{sub 2}O{sub 7} type but structural relationships exist between the frameworks. Impedance measurements (frequency/temperature ranges: 5-13,000 Hz/526-668 K) show KFeAs{sub 2}O{sub 7} an ionic conductor being the conductivity 2.76x10{sup -7} S cm{sup -1} at 568 K and E{sub a} is 0.47 eV. The BVS model suggests that the most probable potassium conduction pathway is along b-direction. Magnetic measurements reveal the Curie-Weiss type paramagnetic behavior over the range 30-300 K and ferromagnetic below 29.3 K. - Graphical abstract: Optimized trajectory for K1-K2-K1 jump as determined by BVS analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ab initio structure determination and Rietveld refinement of Bi{sub 10}Mo{sub 3}O{sub 24} the member n=3 of the Bi{sub 2n+4}Mo{sub n}O{sub 6(n+1)} series

Bi{sub 2}O{sub 3}-MoO{sub 3} system shows a large panoply of phases depending on Bi/Mo ratio, among them, the low temperature phases of the homologous series Bi{sub 2(n+2)}Mo{sub n}O{sub 6(n+1)} with n=3, 4, 5 and 6. They exhibit, alike most of the phases of this system, strong fluorite sub-network. Nevertheless, a multitechnique approach has been followed in order to solve the crystal structure of the n=3 member, i.e. Bi{sub 10}Mo{sub 3}O{sub 24}. From ab initio indexing X-ray powder pattern cell parameters were derived. It belongs to the monoclinic system, space group C2, with cell parameters: a=23.7282(2) A, b=5.64906(6) A, c=8.68173(9) A, beta=95.8668(7){sup o} with Z=2. The matrix relating this cell with the fluorite one is 4 0 1/0 1 0/-1/2 0 3/2 and a cationic localization was derived. HRTEM allowed the cationic Bi and Mo order to be modified and specified, as well as to build up a full structural ab initio model on the basis of crystal chemistry considerations. Simultaneous Rietveld refinement of multipattern X-ray and neutron powder diffraction data taking advantage of the neutron scattering length for O location have been performed. The goodness of the model was ascertained by low reliability factors, weighted R{sub b}=4.97% and R{sub f}=3.21%. This complex Bi{sub 10}Mo{sub 3}O{sub 24} structure, with 5Bi, 2Mo and 13O in different crystallographic positions of the asymmetric unit, shows good agreement between observed and calculated patterns within the data resolution. Moreover, the determination of this structure sets the basis for the crystallographic characterization of the complete family Bi{sub 2(n+2)}Mo{sub n}O{sub 6(n+1)}, whose guidelines are also evidenced in this paper. - Graphical abstract: This work reports on the ab initio determination of Bi{sub 10}Mo{sub 3}O{sub 24} structure, as well as its refinement by using the Rietveld method, from the combination of X-ray and neutron diffraction powder data. It belongs to the monoclinic system, space group C2, with cell parameters: a=23.7282(2) A, b=5.64906(6) A, c=8.68173(9) A, beta=95.8668(7){sup o} with Z=2.

36 MATERIALS SCIENCE↗

Synthesis, crystal structure and electrical proprieties of new phosphate KCoP{sub 3}O{sub 9}

Crystals of new tricyclophosphate KCoP{sub 3}O{sub 9} have been grown from solid state reaction and characterized by single crystal X-ray diffraction. KCoP{sub 3}O{sub 9} crystallizes in the hexagonal system, space group P6{sup ¯}c2, with a=6.616 (7) Å; c=9.788 (3) Å; V=371.06 (13) Å{sup 3}, Z=2. The final agreement factors are R=0.014, ωR=0.038, S(F{sup 2})=1.231. The structure of the title compound can be described as a three-dimensional framework built up of corner sharing CoO{sub 6} and PO{sub 4} polyhedra containing wide tunnels oriented along [001] direction and others, less broad, along [100] and [010] directions. The structural model was validated by bond valence sum (BVS) and charge distribution (CD) methods. Ball milling was used to reduce the particles sizes of the synthesized powder. At the optimal sintering temperature of 800 °C, a relative density of 85% was obtained. The microstructure was characterized by scanning electron microscopy. The electrical conductivity was 8.4×10{sup −7} S cm{sup −1} and 1.7×10{sup −4} S cm{sup −1} at 480 °C and 680 °C respectively. The activation energy deduced from the slope is 2.2 eV at low temperature region and 1.2 eV at high temperature region. The BVS model is extended to simulate the ionic migration pathways of alkali cations in the anionic framework. The BVS calculation shows one-dimensional pathways migration along c-axis. - Graphical abstract: 1D pathways link K atoms along c-axis with bond valence mismatch |ΔV(K)|=0.8 v.u. - Highlights: • A new single crystal KCoP{sub 3}O{sub 9} was grown by solid state reaction and its structure determined by single-crystal X-ray diffraction. • The purity polycrystalline of KCoP{sub 3}O{sub 9} sample was verified by Rietveld refinement. • The CIS measurements were optimized and the obtained spectra were fitted by electrical equivalent circuits. • The conduction pathways for the K{sup +} cations are simulated by means of the bond valence sum model.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A multifrequency study of sub-parsec jets with the Event Horizon Telescope

Context. The 2017 observing campaign of the Event Horizon Telescope (EHT) delivered the first very long baseline interferometry (VLBI) images at the observing frequency of 230 GHz, leading to a number of unique studies on black holes and relativistic jets from active galactic nuclei (AGN). In total, eighteen sources were observed, including the main science targets, Sgr A* and M 87, and various calibrators. Sixteen sources were AGN.Aims. We investigated the morphology of the sixteen AGN in the EHT 2017 data set, focusing on the properties of the VLBI cores: size, flux density, and brightness temperature. We studied their dependence on the observing frequency in order to compare it with the Blandford-Königl (BK) jet model. In particular, we aimed to study the signatures of jet acceleration and magnetic energy conversion.Methods. We modeled the source structure of seven AGN in the EHT 2017 data set using linearly polarized circular Gaussian components (1749+096, 1055+018, BL Lac, J0132–1654, J0006–0623, CTA 102, and 3C 454.3) and collected results for the other nine AGN from dedicated EHT publications, complemented by lower frequency data in the 2–86 GHz range. Combining these data into a multifrequency EHT+ data set, we studied the dependences of the VLBI core component flux density, size, and brightness temperature on the frequency measured in the AGN host frame (and hence on the distance from the central black hole), characterizing them with power law fits. We compared the observations with the BK jet model and estimated the magnetic field strength dependence on the distance from the central black hole.Results. Our observations spanning event horizon to parsec scales indicate a deviation from the standard BK model, particularly in the decrease of the brightness temperature with the observing frequency. Only some of the discrepancies may be alleviated by tweaking the model parameters or the jet collimation profile. Either bulk acceleration of the jet material, energy transfer from the magnetic field to the particles, or both are required to explain the observations. For our sample, we estimate a general radial dependence of the Doppler factor δ ∝ r≤0.5. This interpretation is consistent with a magnetically accelerated sub-parsec jet. We also estimate a steep decrease of the magnetic field strength with radius B ∝ r−3, hinting at jet acceleration or efficient magnetic energy dissipation.Key words: techniques: interferometric / galaxies: active / galaxies: jets / galaxies: nuclei / quasars: general / quasars: supermassive black holes⋆⋆ Deceased.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electrostatically driven helical plasma state

A novel plasma state has been found in the presence of a uniformly applied axial magnetic field in periodic cylindrical geometry. This state is driven electrostatically by helical electrodes, providing a driving field that depends on the radius and mθ−nζ, where θ is the poloidal angle and ζ=z/R is the toroidal angle. We focus on m=n=1. The radial magnetic field at the wall is taken to be zero. With weak driving, the resulting distortion is very small, but for stronger driving, the mean field of the state has field line safety factor q0(r) just above the pitch of the electrodes m∕n = 1 except near the edge, where q0 increases monotonically. This state is characterized as a single helicity Ohmic equilibrium with the helical symmetry of the applied field. The plasma appears to be close to force-free in the interior, but current density crosses the magnetic flux surfaces near the edge, where current must enter and exit through the helical electrodes. This perpendicular current density drives large helical plasma flows. The sensitivity of this state to flow boundary conditions, plasma resistivity profile, the strength of electrostatic driving, and parameters such as the loop voltage and the Lundquist number is explored. The magnetic helicity is calculated for both the transient period and time-asymptotic state. Possible applications to current drive in toroidal confinement devices and to electrical transformers are discussed.

Akçay, Cihan↗

On the role of shear in cosmological averaging

Using the spherically symmetric inhomogeneous Lemaitre-Tolman-Bondi dust solution, we study how the shear and the backreaction depend on the sharpness of the spatial transition between voids and walls and on the size of the voids. The voids considered here are regions with matter density Ω{sub 0} ≅ 0 and expansion rate H{sub 0}t{sub 0} ≅ 1, while the walls are regions with matter density Ω{sub 0} ≅ 1 and expansion rate H{sub 0}t{sub 0} ≅ 2/3. The results indicate that both the volume-average shear and the variance of the expansion rate grow proportional to the sharpness of the transition and diverge in the limit of a step function, but, for realistic-sized voids, are virtually independent of the size of the void. However, the backreaction, given by the difference of the variance and the shear, has a finite value in the step-function limit. By comparing the exact result for the backreaction to the case where the shear is neglected by treating the voids and walls as separate Friedmann-Robertson-Walker models, we find that the shear suppresses the backreaction by a factor of (r{sub 0}/t{sub 0}){sup 2}, the squared ratio of the void size to the horizon size. This exemplifies the importance of using the exact solution for the interface between the regions of different expansion rates and densities. The suppression is justified to hold also for a network of compensated voids, but may not hold if the universe is dominated by uncompensated voids.

79 ASTRONOMY AND ASTROPHYSICS↗

An Empirical Method for deriving RBE values associated with Electrons, Photons and Radionuclides

There is substantial evidence to justify using relative biological effectiveness (RBE) values greater than one for low-energy electrons and photons. But, in the field of radiation protection, radiation associated with low linear energy transfer (LET) has been assigned a radiation weighting factor w R of one. This value may be suitable for radiation protection but, for risk considerations, it is important to evaluate the potential elevated biological effectiveness of radiation to improve the quality of risk estimates. RBE values between 2 and 3 for tritium are implied by several experimental measurements. Additionally, elevated RBE values have been found for other similar low-energy radiation sources. In this work, RBE values are derived for electrons based upon the fractional deposition of absorbed dose of energies less than a few keV. Using this empirical method, RBE values were also derived for monoenergetic photons and 1070 radionuclides from ICRP Publication 107 for which photons and electrons are the primary emissions.

59 BASIC BIOLOGICAL SCIENCES↗

Flow-plane decorrelations in heavy-ion collisions with multiple-plane cumulants

The azimuthal correlations between local flow planes at different (pseudo)rapidities (η) may reveal important details of the initial nuclear matter density distributions in heavy-ion collisions. Extensive experimental measurements of a factorization ratio (r 2 ) and its derivative (F 2 ) have shown evidence of the longitudinal flow-plane decorrelation. However, nonflow effects also affect this observable and prevent a quantitative understanding of the phenomenon. In this paper, to distinguish decorrelation and nonflow effects, we propose a new cumulant observable, T 2 , which largely suppresses nonflow. Here, the technique sensitivity to different initial-state scenarios and nonflow effects are tested with a simple Monte Carlo model, and in the end, the method is applied to events simulated by a multiphase transport model (AMPT) for Au+Au collisions at $\sqrt{s_{NN}}$ = 200 GeV. We also emphasize that a distinct decorrelation signal requires not only the right sign of an observable but also its proper dependence on the η window of the reference flow plane to be consistent with the pertinent decorrelation picture.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗