Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Quantum repeaters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Electron spin resonance spectroscopy with femtoliter detection volume

We report electron spin resonance measurements of donors in silicon at millikelvin temperatures using a superconducting LC planar micro-resonator and a Josephson parametric amplifier. The resonator includes a nanowire inductor, defining a femtoliter detection volume. Due to strain in the substrate, the donor resonance lines are heavily broadened. In this work, single-spin to photon coupling strengths up to ~ 3 kHz are observed. The single shot sensitivity is 120 ± 24 spins/Hahn echo, corresponding to ≈ 12 ± 3 spins / Hz for repeated acquisition.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Investigating Wireless Quantum Key Distribution for Advanced Reactor Communications

Remote operation of small modular reactor (SMR) facilities is an appealing prospect for streamlined operation costs, safety concerns, and user convenience. The ability to guarantee security of communication channels between offsite users and nuclear reactor facilities is critical to enabling remote operations, given the sensitive nature of reactor state data. This report proposes a configuration implementing quantum key distribution (QKD) and advanced encryption standard (AES) protocols to establish secure reactor data feeds. The model outlined, which utilizes the Argonne-developed SeQUeNCe software package and custom MATLAB code, determines free-space channel losses for microwave-band communications in a variety of weather conditions and simulates QKD via ground-satellite links. This report demonstrates the feasibility of repeatable, real-time key generation and distribution for this configuration towards enabling secure wireless reactor communications.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

3D Volumetric Structural Hierarchy Induced by Colloidal Polymerization of a Quantum-Dot Ionic Liquid Monomer Conjugate

Hierarchically structured emissive quantum dot (CdS/CdSe) poly(ionic liquid) composites are synthesized through colloidal polymerization within a lyotropic liquid crystal, yielding a solvent-responsive nanoparticle (NP) composite possessing four ordered structural motifs. The composite is prepared by coassembling an amphiphilic ionic liquid (IL) monomer, 3-decyl-1-vinylimidazolium chloride, [C 10 VIm + ][Cl - ], and IL monomer, 3-(10-mercaptodecyl)-1-vinylimidazolium bromide surface-functionalized quantum dots, QD-[SC 10 VIm + ][Br - ], in 30 wt % water. Photo (UV)-initiated free radical polymerization serves to form a colloidal copolymer that collimates pairs of QDs within the core of large cylinders (average diameter = 21 nm and length = 422 nm), as evidenced by ultrasmall-angle X-ray scattering (USAXS). As revealed by continuous wave terahertz multispectral reconstructive 3-D imaging, the subsurface structure along the cylinder axis undergoes dynamic rearrangement between 2D hexagonal and cubic packing. The polymerized ionic liquid sheath surrounding the QDs is composed of concentric hexagonally perforated lamellae (HPL) with an interlamellar repeat distance of 3 nm, as determined by small-angle X-ray scattering (SAXS). The encapsulated QDs retain crystallinity (TEM and WAXS) and emission characteristics (photoluminescence spectroscopy, lambda(EM) = 638 nm). Phenomenological time-dependent Ginzburg-Landau calculations verify the mesoscale cylinders arise from the topological constraints imposed by the in-plane perforations of the polymerized ionic liquid as it wraps around the hard (unmalleable) spherical QDs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanoparticles up-regulate tumor necrosis factor-{alpha} and CXCL8 via reactive oxygen species and mitogen-activated protein kinase activation

Evaluating the toxicity of nanoparticles is an integral aspect of basic and applied sciences, because imaging applications using traditional organic fluorophores are limited by properties such as photobleaching, spectral overlaps, and operational difficulties. This study investigated the toxicity of nanoparticles and their biological mechanisms. We found that nanoparticles, quantum dots (QDs), considerably activated the production of tumor necrosis factor (TNF)-{alpha} and CXC-chemokine ligand (CXCL) 8 through reactive oxygen species (ROS)- and mitogen-activated protein kinases (MAPKs)-dependent mechanisms in human primary monocytes. Nanoparticles elicited a robust activation of intracellular ROS, phosphorylation of p47phox, and nicotinamide adenine dinucleotide phosphate oxidase activities. Blockade of ROS generation with antioxidants significantly abrogated the QD-mediated TNF-{alpha} and CXCL8 expression in monocytes. The induced ROS generation subsequently led to the activation of MAPKs, which were crucial for mRNA and protein expression of TNF-{alpha} and CXCL8. Furthermore, confocal and electron microscopy analyses showed that internalized QDs were trapped in cytoplasmic vesicles and compartmentalized inside lysosomes. Finally, several repeated intravenous injections of QDs caused an increase in neutrophil infiltration in the lung tissues in vivo. These results provide novel insights into the QD-mediated chemokine induction and inflammatory toxic responses in vitro and in vivo.

60 APPLIED LIFE SCIENCES↗

Incorporation model of N into GaInNAs alloys grown by radio-frequency plasma-assisted molecular beam epitaxy

We present a Maxwell-Boltzmann electron energy distribution based model for the incorporation rate of nitrogen into GaInNAs grown by molecular beam epitaxy (MBE) using a radio frequency plasma source. Nitrogen concentration is predicted as a function of radio-frequency system primary resistance, N flow, and RF power, and group III growth rate. The semi-empirical model is shown to be repeatable with a maximum error of 6%. The model was validated for two different MBE systems by growing GaInNAs on GaAs(100) with variable nitrogen composition of 0%–6%.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SMWDs as SGRs/AXPs and the lepton number violation

Possible nature of strongly magnetized white dwarfs (SMWDs) is studied. It is shown that for relatively low values of the equatorial surface magnetic field B ∼ 10{sup 9} − 10{sup 11} G they can be good candidates for soft gamma-ray repeaters and anomalous X-ray pulsars (SGRs/AXPs). For the case of iron SMWDs the influence of a neutrinoless electron to positron conversion on the SGRs/AXPs luminosity is estimated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Heterogeneous metasurface for high temperature selective emission

We demonstrate selective emission from a heterogeneous metasurface that can survive repeated temperature cycling at 1300 K. Simulations, fabrication, and characterization were performed for a cross-over-a-backplane metasurface consisting of platinum and alumina layers on a sapphire substrate. The structure was stabilized for high temperature operation by an encapsulating alumina layer. The geometry was optimized for integration into a thermophotovoltaic (TPV) system, and was designed to have its emissivity matched to the external quantum efficiency spectrum of 0.6 eV InGaAs TPV material. We present spectral measurements of the metasurface that result in a predicted 22% optical-to-electrical power conversion efficiency in a simplified model at 1300 K. Furthermore, this broadly adaptable selective emitter design can be easily integrated into full-scale TPV systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Plasma Doping - Enabling Technology for High Dose Logic and Memory Applications

As logic and memory device dimensions shrink with each generation, there are more high dose implants at lower energies. Examples include dual poly gate (also referred to as counter-doped poly), elevated source drain and contact plug implants. Plasma Doping technology throughput and dopant profile benefits at these ultra high dose and lower energy conditions have been well established [1,2,3]. For the first time a production-worthy plasma doping implanter, the VIISta PLAD tool, has been developed with unique architecture suited for precise and repeatable dopant placement. Critical elements of the architecture include pulsed DC wafer bias, closed-loop dosimetry and a uniform low energy, high density plasma source. In this paper key performance metrics such as dose uniformity, dose repeatability and dopant profile control will be presented that demonstrate the production-worthiness of the VIISta PLAD tool for several high dose applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical re-injection in cavity-enhanced absorption spectroscopy

Non-mode-matched cavity-enhanced absorption spectrometry (e.g., cavity ringdown spectroscopy and integrated cavity output spectroscopy) is commonly used for the ultrasensitive detection of trace gases. These techniques are attractive for their simplicity and robustness, but their performance may be limited by the reflection of light from the front mirror and the resulting low optical transmission. Although this low transmitted power can sometimes be overcome with higher power lasers and lower noise detectors (e.g., in the near-infrared), many regimes exist where the available light intensity or photodetector sensitivity limits instrument performance (e.g., in the mid-infrared). In this article, we describe a method of repeatedly re-injecting light reflected off the front mirror of the optical cavity to boost the cavity's circulating power and deliver more light to the photodetector and thus increase the signal-to-noise ratio of the absorption measurement. We model and experimentally demonstrate the method's performance using off-axis cavity ringdown spectroscopy (OA-CRDS) with a broadly tunable external cavity quantum cascade laser. The power coupled through the cavity to the detector is increased by a factor of 22.5. The cavity loss is measured with a precision of 2 × 10{sup −10} cm{sup −1}/√(Hz;) an increase of 12 times over the standard off-axis configuration without reinjection and comparable to the best reported sensitivities in the mid-infrared. Finally, the re-injected CRDS system is used to measure the spectrum of several volatile organic compounds, demonstrating the improved ability to resolve weakly absorbing spectroscopic features.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The climate of HD 189733b from fourteen transits and eclipses measured by Spitzer

We present observations of six transits and six eclipses of the transiting planet system HD 189733 taken with the Spitzer Space Telescope IRAC camera at 8 microns, as well as a re-analysis of previously published data. We use several novel techniques in our data analysis, the most important of which is a new correction for the detector 'ramp' variation with a double-exponential function which performs better and is a better physical model for this detector variation. Our main scientific findings are: (1) an upper limit on the variability of the day-side planet flux of 2.7% (68% confidence); (2) the most precise set of transit times measured for a transiting planet, with an average accuracy of 3 seconds; (3) a lack of transit-timing variations, excluding the presence of second planets in this system above 20% of the mass of Mars in low-order mean-motion resonance at 95% confidence; (4) a confirmation of the planet's phase variation, finding the night side is 64% as bright as the day side, as well as an upper limit on the night-side variability of 17% (68% confidence); (5) a better correction for stellar variability at 8 micron causing the phase function to peak 3.5 hours before secondary eclipse, confirming that the advection and radiation timescales are comparable at the 8 micron photosphere; (6) variation in the depth of transit, which possibly implies variations in the surface brightness of the portion of the star occulted by the planet, posing a fundamental limit on non-simultaneous multi-wavelength transit absorption measurements of planet atmospheres; (7) a measurement of the infrared limb-darkening of the star, which is in good agreement with stellar atmosphere models; (8) an offset in the times of secondary eclipse of 69 seconds, which is mostly accounted for by a 31 second light travel time delay and 33 second delay due to the shift of ingress and egress by the planet hot spot; this confirms that the phase variation is due to an offset hot spot on the planet; (9) a retraction of the claimed eccentricity of this system due to the offset of secondary eclipse, which is now just an upper limit; and (10) high precision measurements of the parameters of this system. These results were enabled by the exquisite photometric precision of the Spitzer IRAC camera; for repeat observations the scatter is less than 0.35 mmag over the 590 day time scale of our observations after decorrelating with detector parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Annual Report for the QCL Calibration Project

Under the Quantum Cascade Laser (QCL) Calibrations project, Pacific Northwest National Laboratory (PNNL) is collaborating with Utah State University and Space Dynamics Laboratory to design, build, and test a QCL calibration source system suitable for insertion into remote sensing platforms. In FY14, the second year of this project, PNNL completed the radiation testing of QCLs using radiation levels that are typical for a space environment. These tests involved both 64-MeV protons, and 1.17-MeV and 1.33-MeV gamma rays. No changes were observed above the measurement uncertainty indicating that QCLs are viable sources for space-based missions. High-level testing was also carried out with gamma rays to determine if QCLs are sensitive to high doses of gamma radiation. After an accumulated dose of 1.5 Mrad(Si), the QCLs continue to demonstrate high performance although a small increase in threshold current, 0.11 ± 0.14% and 0.51 ± 0.15% for M1244D and M664M, respectively, was observed. At this stage, it is unclear if this small increase is from the radiation exposure, because generally it is within the observed experimental uncertainty, which is most likely because of mechanical changes through repeated mounting cycles. There was also some accidental damage to the laser chips and their front facets from the extensive but necessary handling of the devices during these tests. Regardless, the QCLs are robust and should not be susceptible to degradation for most missions.

36 MATERIALS SCIENCE↗

A novel hardmask-to-substrate pattern transfer method for creating 3D, multi-level, hierarchical, high aspect-ratio structures for applications in microfluidics and cooling technologies

Abstract This letter solves a major hurdle that mars photolithography-based fabrication of micro-mesoscale structures in silicon. Conventional photolithography is usually performed on smooth, flat wafer surfaces to lay a 2D design and subsequently etch it to create single-level features. It is, however, unable to process non-flat surfaces or already etched wafers and create more than one level in the structure. In this study, we have described a novel cleanroom-based process flow that allows for easy creation of such multi-level, hierarchical 3D structures in a substrate. This is achieved by introducing an ultra-thin sacrificial silicon dioxide hardmask layer on the substrate which is first 3D patterned via multiple rounds of lithography. This 3D pattern is then scaled vertically by a factor of 200–300 and transferred to the substrate underneath via a single shot deep etching step. The proposed method is also easily characterizable—using features of different topographies and dimensions, the etch rates and selectivities were quantified; this characterization information was later used while fabricating specific target structures. Furthermore, this study comprehensively compares the novel pattern transfer technique to already existing methods of creating multi-level structures, like grayscale lithography and chip stacking. The proposed process was found to be cheaper, faster, and easier to standardize compared to other methods—this made the overall process more reliable and repeatable. We hope it will encourage more research into hybrid structures that hold the key to dramatic performance improvements in several micro-mesoscale devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantum noise properties of CT images with anatomical textured backgrounds across reconstruction algorithms: FBP and SAFIRE

Purpose: Quantum noise properties of CT images are generally assessed using simple geometric phantoms with uniform backgrounds. Such phantoms may be inadequate when assessing nonlinear reconstruction or postprocessing algorithms. The purpose of this study was to design anatomically informed textured phantoms and use the phantoms to assess quantum noise properties across two clinically available reconstruction algorithms, filtered back projection (FBP) and sinogram affirmed iterative reconstruction (SAFIRE). Methods: Two phantoms were designed to represent lung and soft-tissue textures. The lung phantom included intricate vessel-like structures along with embedded nodules (spherical, lobulated, and spiculated). The soft tissue phantom was designed based on a three-dimensional clustered lumpy background with included low-contrast lesions (spherical and anthropomorphic). The phantoms were built using rapid prototyping (3D printing) technology and, along with a uniform phantom of similar size, were imaged on a Siemens SOMATOM Definition Flash CT scanner and reconstructed with FBP and SAFIRE. Fifty repeated acquisitions were acquired for each background type and noise was assessed by estimating pixel-value statistics, such as standard deviation (i.e., noise magnitude), autocorrelation, and noise power spectrum. Noise stationarity was also assessed by examining the spatial distribution of noise magnitude. The noise properties were compared across background types and between the two reconstruction algorithms. Results: In FBP and SAFIRE images, noise was globally nonstationary for all phantoms. In FBP images of all phantoms, and in SAFIRE images of the uniform phantom, noise appeared to be locally stationary (within a reasonably small region of interest). Noise was locally nonstationary in SAFIRE images of the textured phantoms with edge pixels showing higher noise magnitude compared to pixels in more homogenous regions. For pixels in uniform regions, noise magnitude was reduced by an average of 60% in SAFIRE images compared to FBP. However, for edge pixels, noise magnitude ranged from 20% higher to 40% lower in SAFIRE images compared to FBP. SAFIRE images of the lung phantom exhibited distinct regions with varying noise texture (i.e., noise autocorrelation/power spectra). Conclusions: Quantum noise properties observed in uniform phantoms may not be representative of those in actual patients for nonlinear reconstruction algorithms. Anatomical texture should be considered when evaluating the performance of CT systems that use such nonlinear algorithms.

60 APPLIED LIFE SCIENCES↗

Simple non-galvanic flip-chip integration method for hybrid quantum systems

A challenge faced by experimenters exploring hybrid quantum systems is how to integrate and interconnect different materials and different substrates in a quantum-coherent fashion. Here, we present a simple and inexpensive flip-chip bonding process, suitable for integrating hybrid quantum devices on chips from different substrates. The process only requires equipment and materials used routinely for contact photolithography, and it is possible to undo the bonding and reuse the chips. The technique requires minimal compressive force, so it is compatible with a wide range of different substrates. Unlike indium-based bonding, this process does not establish a galvanic connection between the two chips, but as we show, in some situations this is not necessary. We demonstrate the technique using lithographically patterned quarter-wave coplanar waveguide resonators, fabricated on one chip, and couple these inductively to a transmission line patterned lithographically on a separate chip. The two chips have a vertical interchip gap of about 7 μm, and we can repeatedly achieve lateral alignments of better than 2μm. We measure electromagnetic resonances with low-power (similar to ~1 photon) internal quality factors Q i around 5 x 10 5 , comparable to single-chip performances, with as-designed coupling quality factors Q c ranging from 2 x 10 2 to 5 x 10 5 .

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Translating Non-Trivial Algorithms from the Circuit Model to the Measurement

We provide a set of prescriptions for implementing a circuit model algorithm as measurement based quantum computing via a large discrete cluster state constructed sequentially, from qubits implemented as single photons. We describe a large optical discrete graph state capable of searching logical 4 and 8 element lists as an example. To do so we have developed several prescriptions based on analytic evaluation of the evolution of discrete cluster states and graph state equations. We describe the cluster state as a sequence of repeated entanglement and measurement steps using a small number of single photons for each step. These prescriptions can be generalized to implement any logical circuit model operation with appropriate single photon measurements and feed forward error corrections. Such a cluster state is not guaranteed to be optimal (i.e. minimum number of photons, measurements, run time).

Smith, IV, Amos M↗

Enhancement of humidity sensitivity of graphene through functionalization with polyethylenimine

In this work, we show that the sensing performance of graphene based humidity sensors can be largely improved through polymer functionalization. Chemical vapor deposited graphene is functionalized with amine rich polymer, leading to electron transfer from amine groups in the polymer to graphene. The functionalized graphene humidity sensor has demonstrated good sensitivity, recovery, and repeatability. Charge transfer between the functionalized graphene and water molecules and the sensing mechanism are studied systemically using field effect transistor geometry and scanning Kelvin probe microscopy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-accuracy measurements of the normal specular reflectance

The French Laser Megajoule (LMJ) is designed and constructed by the French Commissariata l'Energie Atomique (CEA). Its amplifying section needs highly reflective multilayer mirrors for the flash lamps. To monitor and improve the coating process, the reflectors have to be characterized to high accuracy. The described spectrophotometer is designed to measure normal specular reflectance with high repeatability by using a small spot size of 100 {mu}m. Results are compared with ellipsometric measurements. The instrument can also perform spatial characterization to detect coating nonuniformity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Polymeric electrochemical element for adaptive networks: Pulse mode

An electrochemically controlled polymeric heterojunction working as a memristor, i.e., having memory properties, was investigated in pulse mode, mimicking synaptic behavior of signal transmission in biological systems. Influence of parameters such as pulse duration, interval between pulses, and value of potential base level was analyzed. Learning capabilities were shown to be reversible and repeatable for both potentiation and inhibition of signal transmission. The adaptive behavior of the element was investigated and was shown to be more efficient than the dc mode.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗