Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Quantum efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

The future scientific CCD

Since the first introduction of charge-coupled devices (CCDs) in 1970, CCDs have been considered for applications related to memories, logic circuits, and the detection of visible radiation. It is pointed out, however, that the mass market orientation of CCD development has left largely untapped the enormous potential of these devices for advanced scientific instrumentation. The present paper has, therefore, the objective to introduce the CCD characteristics to the scientific community, taking into account prospects for further improvement. Attention is given to evaluation criteria, a summary of current CCDs, CCD performance characteristics, absolute calibration tools, quantum efficiency, aspects of charge collection, charge transfer efficiency, read noise, and predictions regarding the characteristics of the next generation of silicon scientific CCD imagers.

Janesick, J. R.↗

Generalized reciprocity theorem for semiconductor devices

A reciprocity theorem is presented that relates the short-circuit current of a device, induced by a carrier generation source, to the minority-carrier Fermi level in the dark. The basic relation is general under low injection. It holds for three-dimensional devices with position dependent parameters (energy gap, electron affinity, mobility, etc.), and for transient or steady-state conditions. This theorem allows calculation of the internal quantum efficiency of a solar cell by using the analysis of the device in the dark. Other applications could involve measurements of various device parameters, interfacial surface recombination velocity at a polcrystalline silicon emitter contact, for rexample, by using steady-state or transient photon or mass-particle radiation.

Misiakos, K.↗

Charge-coupled device camera for the Galileo Jupiter Orbiter spacecraft

A slow-scan television camera called the solid-state imaging subsystem (SSI), built for the Galileo Jupiter Orbiter, is described. The SSI consists of a 1500-mm focal-length telescope coupled to a camera head housing a 800 x 800-element charge-coupled device (CCD) detector based on 'virtual-phase' charge transfer technology. The CCD detector provides broadband sensitivity over 100 times that of a comparable vidicon-tube camera, while also yielding improved resolution, linearity, geometric fidelity, and spectral range. The system noise floor is 30 electrons, which results in a dynamic range of about 3500. Saturation of the detector with 9000-A light, followed by a high-speed erasure cycle prior to exposing each image, stabilizes the detector quantum efficiency at its maximum level for wavelengths beyond 7000 A. An optical schematic diagram of the SSI is included.

Klaasen, K. P.↗

An imaging proportional counter for a 0.1 to 10 keV X-ray telescope

A xenon multiwire position-sensitive proportional counter (PSPC) with a high degree of long-term stability has been constructed and tested in detail. It is suitable for a 0.1 to 10 keV X-ray telescope such as AXAF, which it would share with detectors having better spatial and spectral resolution. Compared to other detectors, the larger format, higher quantum efficiency, and lower background of the PSPC makes it generally the most useful instrument for observations of diffuse cosmic X-ray sources and associations of sources more extended than a few tenths of a degree in diameter. Given the good spatial linearity, the systematic uncertainty for source locations is finer than an arcsecond. The spatial resolution varies as 0.3 mm/exp 0.5 (keV) over the range 0.2-4 keV, in accordance with theoretical limits determined by the size and the number of electrons in the primary charge cloud.

Gorenstein, P.↗

An intensified photodiode array detector for space applications

The Hopkins Ultraviolet Telescope (HUT) is a general purpose moderate resolution spectrograph which is now being constructed for launch on the Space Shuttle. The instrument contains a Rowland spectrograph, which is located at the prime focus of a 0.9-m f/2 parabola. A description is given of the progress which has been made in the development of a flight detector for HUT. The detector developed is an intensified photodiode array. The image intensifier part of the detector contains two 25-mm 80:1, 12-micron pore microchannel plates (PCPs). A thin layer of CsI deposited on the front surface of the first microchannel plate has the objective to increase the quantum efficiency of the detector below 1850 A. The detector system utilizes a spectrometer processor (SP) which is based upon a bit-sliced microprocessor. The current status of the HUT detector system is discussed, and aspects of performance are evaluated. It is felt that the developed system will meet or exceed the design requirements.

Long, K. S.↗

Effect of low-energy hydrogen ion implantation on dendritic web silicon solar cells

The effect of a low-energy (0.4 keV), short-time (2-min), heavy-dose (10 to the 18th/sq cm) hydrogen ion implant on dendritic web silicon solar cells and material was investigated. Such an implant was observed to improve the cell open-circuit voltage and short-circuit current appreciably for a number of cells. In spite of the low implant energy, measurements of internal quantum efficiency indicate that it is the base of the cell, rather than the emitter, which benefits from the hydrogen implant. This is supported by the observation that the measured minority-carrier diffusion length in the base did not change when the emitter was removed. In some cases, a threefold increase of the base diffusion length was observed after implantation. The effects of the hydrogen implantation were not changed by a thermal stress test at 250 C for 111 h in nitrogen. It is speculated that hydrogen enters the bulk by traveling along dislocations, as proposed recently for edge-defined film-fed growth silicon ribbon.

Rohatgi, A.↗

Yields of O2(b 1 Sigma g +) from reactions of HO2

The production of O2(b 1 Sigma g +) has been monitored for several reactions of the HO2 radical at 300 K using a discharge-flow apparatus with resonance fluorescence and chemiluminescence detection. In all cases, the resulting quantum efficiencies were found to be less than 0.03. O2(b) was observed when F atoms were added to H2O2 in the gas phase. The signal strengths of O2(b) were proportional to initial concentrations of HO2 formed by the F + H2O2 reaction. Observed /O2(b)/, /HO2/, and /OH/ vs /F/0 were analyzed using a simple three-step mechanism and a more complete computer simulation with 22 reaction steps. The results indicate that the F + HO2 reaction yields O2(b) with an efficiency of (3.6 + or - 1.4) x 10 to the -3rd. Yields from the O + OH2 reaction were less than 0.02, indicating that this reaction cannot be a major source of the O2(b) emission observed in the earth's nightglow.

Keyser, L. F.↗

Detector requirements for space infrared astronomy

Requirements for background-limited (BLIP) detectors are discussed in terms of number of photons falling on each pixel, dark current, high detective quantum efficiencies, large numbers of pixels, and array size.

Wright, E. L.↗

Ge:Be infrared photoconductors

Ge:Be photoconductors were optimized for the 30 to 50 micron wavelength range. Crystal growth of detector quality material requires good control of both the Be and residual impurity doping. Detective quantum efficiencies of n sub d = 46% at 5 A/W were achieved at a photon background of 10 to the 8th power p/s. The responsivity of Ge:Be detectors can be strongly temperature-dependent when the residual shallow levels in the material are closely compensated. Transient responses on the order of approximately 1 second were observed in some materials. The role of residual shallow impurities on the performance of photoconductors doped with semi-deep and deep impurities is discussed.

Haegel, N. M.↗

Low-background InSb array development

Photovoltaic indium antimonide (PV InSb) detector technology has matured over the past several years to enable a wide variety of applications to use this high-performance detector material to advantage. The operating conditions for most of the applications to date for back-side illuminated PV InSb arrays have encompassed focal plane temperatures ranging from 40 to approximately 95 K, with the majority in the narrower range between 60 and 80 K. Background flux conditions have ranged from 10 to the 10th power ph/sq cm/sec to 10 to the 16th power ph/sq cm/sec, most typically between 10 to the 12th power and 10 to the 14th power ph/sq cm/sec. Appropriately, the array parameters were optimized for maximum performance over these temperature and background ranges. The key parameters which were peaked in this process were the resistance-area product of the detectors and their quantum efficiency. The Space Infrared Telescope Facility (SIRTF) Infrared Array Camera requirements, however, present very low temperature and background operating conditions, plus the need for very high signal to noise ratios. Preliminary analysis indicates that back-side illuminated PV InSb arrays can be optimized for operation under these conditions, and some performance projections will be presented.

Thom, R. D.↗

Evaluation of Rockwell HgCdTe arrays for astronomical use

The 32 x 32 HgCdTe array manufactured by Rockwell International was proven to be a highly competitive detector type for use at wavelengths shorter than 2.5 microns. The goal of a K=+16 sky survey using this array attached to the Steward Observatory Transit Telescope is clearly within reach. The detector material exhibits high quantum efficiency and low dark currents indicating that its usefulness may extend beyond its use with a CCD readout on groundbased telescopes.

Lebofsky, M. J.↗

Evaluation and characterization of hybrid arrays

An Infrared Camera was built for astronomical observations and for testing arrays for satellite based work. The detectors are sensitive to mid infrared wavelengths. The camera was tested at the University of Arizona 61 and 90 inch telescopes and the NASA IRTF. These tests have demonstrated a sensitivity consistent with photon shot noise with an approximately 10% quantum efficiency for each pixel when the camera was used with a 1.6% spectral filter or when used with a Fabry-Perot having a resolving power of 2000. Initial measurements of read out noise, dark current, cross talk, and hysteresis were made. The detector chip in current use is a hybrid array manufactured by the Hughes Aircraft Company. Because part of the goal was to develop and advance technology, it was decided to work with a switched MOSFET array. This architecture is very promising, and the detector parameters will be quantified carefully.

Arens, J. F.↗

Direct solar-pumped iodine laser amplifier

In order to evaluate the feasibility of the solar pumped dye laser, the parametric study of a dye laser amplifier pumped by a solar simulator and flashlamp was carried out, and the amplifier gains were measured at various pump beam irradiances on the dye cell. Rhodamine 6G was considered as a candidate for the solar pumped laser because of its good utilization of the solar spectrum and high quantum efficiency. The measurement shows that a solar concentration of 20,000 is required to reach the threshold of the dye. The work to construct a kinetic model algorithm which predicts the output parameter of laser was progressed. The kinetic model was improved such that there is good agreement between the theoretical model and experimental data for the systems defined previously as flashlamp pumped laser oscillator, and the long path length solar pumped laser.

Han, Kwang S.↗

The GSFC/Wisconsin X-ray spectroscopy investigation for AXAF

A novel device is described which combines the high quantum efficiency of a photoelectric detector with the high energy resolution of a dispersive spectrometer in a system that operates simultaneously over the whole AXAF bandpass. It is basically an X-ray calorimeter, in which the temperature rise of an X-ray absorber following the deposition of energy from a single X-ray photon can be measured to an accuracy expected to be of order one part in 1000 at 6 keV.

Holt, S. S.↗

Microchannel plates and image detection at soft X-ray wavelengths

Detector systems based on the high-gain microchannel plate (MCP) electron multiplier have been used extensively for imaging at soft X-ray wavelengths both on the ground and in space. The latest pulse-counting electronic readout systems provide zero readout-noise, spatial resolutions (FWM) of 25 microns or better and can determine the arrival times of detected photons to an accuracy of the order of 100 ns. These systems can br developed to produce detectors with active areas of 100 mm in diameter or greater. The use of CsI photocathodes produces very high detective quantum efficiencies to wavelengths between about 100 and 1A (0.1 to 10 keV) with moderate energy resolution. The operating characteristics of the different types of soft X-ray MCP detector systems are described, and the prospects for future developments are discussed.

Timothy, J. G.↗

CCD advances for X-ray scientific measurements in 1985

A theoretical model is presented which predicts the output response of a CCD to soft X-ray spectra. The model simulates the four fundamental parameters that ultimately limit CCD performance: quantum efficiency, charge collection efficiency, charge transfer efficiency, and read noise. Simulated results are presented for a wide variety of CCD structures, and general conclusions are presented about achieving a practical balance of sensitivity, energy, and spatial resolution for an AXAF instrument. The results of the analysis are compared to an existing state-of-the art CCD and improvements which will be made in the near future are projected.

Janesick, James↗

The Extreme Ultraviolet Explorer and the local interstellar medium

The EUV Explorer (EUVE) mission is described, with emphasis on the overall capabilities of the instrumentation and the relevance of the mission to determining parameters of the local interstellar medium. The primary purpose of the mission is to search the celestial sphere for astronomical sources of EUV radiation (100-1000 A). The search will be accomplished with the use of three EUV telescopes, sensitive to different segments of the EUV band. A fourth telescope will perform a high-sensitivity search of a limited sample of the sky in the shortest-wavelength bands. The all-sky survey will be carried out in the first six months of the mission. The second six months of the mission, conducted entirely by Guest Investigators selected by NASA, will be devoted to spectroscopic observations of selected EUV sources. The instrumentation is now well developed. The best mirror has full-width/half-energy spread of 8 arcsec and a surface finish of 20 A. Prototype thin-film bandpass filters have been flown on the Space Shuttle and their performance optimized. Prototype detectors have been developed which have 600 by 600-pixel imaging capability and up to 80-percent quantum efficiency in parts of the EUV band.

Bowyer, Stuart↗

Thinning and mounting a Texas Instruments 3-phase CCD

Thin CCDs with precise control of thickness and surface quality allow astronomers to optimize chips for specific applications. A means of mechanically thinning a TI 800 x 800 CCD with an abrasive slurry of aluminum oxide is presented. Using the same techniques, the abrasives can be replaced with a chemical solution to eliminate subsurface damage. A technique of mounting the CCD which retains the high quality surface generated during thinning is also demonstrated. This requires the backside of the chip to be bonded to a glass window which closely matches silicon's thermal expansion properties. Thinned CCDs require backside treatment to enhance blue and UV quantum efficiency. Two methods are discussed which may be effective with this mounting system.

Lesser, M. P.↗