Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Proton”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Cumulants and correlation functions of net-proton, proton, and antiproton multiplicity distributions in Au+Au collisions at energies available at the BNL Relativistic Heavy Ion Collider

Here, we report a systematic measurement of cumulants, C n , for net-proton, proton, and antiproton multiplicity distributions, and correlation functions, κ n , for proton and antiproton multiplicity distributions up to the fourth order in Au+Au collisions at $\sqrt{s_{NN}}$ = 7.7, 11.5, 14.5, 19.6, 27, 39, 54.4, 62.4, and 200 GeV. The C n and κ n are presented as a function of collision energy, centrality and kinematic acceptance in rapidity, y, and transverse momentum, p T . The data were taken during the first phase of the Beam Energy Scan (BES) program (2010–2017) at the BNL Relativistic Heavy Ion Collider (RHIC) facility. The measurements are carried out at midrapidity (|y| < 0.5) and transverse momentum 0.4 < p T < 2.0 GeV/c, using the STAR detector at RHIC. We observe a nonmonotonic energy dependence ($\sqrt{s_{NN}}$ = 7.7–62.4 GeV) of the net-proton C 4 /C 2 with the significance of 3.1σ for the 0–5% central Au+Au collisions. This is consistent with the expectations of critical fluctuations in a QCD-inspired model. Thermal and transport model calculations show a monotonic variation with $\sqrt{s_{NN}}$. For the multiparticle correlation functions, we observe significant negative values for a two-particle correlation function, κ 2 , of protons and antiprotons, which are mainly due to the effects of baryon number conservation. Furthermore, it is found that the four-particle correlation function, κ 4 , of protons plays a role in determining the energy dependence of proton C 4 /C 1 below 19.6 GeV, which cannot be understood by the effect of baryon number conservation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Absorptive corrections to the electromagnetic form factor in high-energy elastic proton-proton scattering

Recently, it was noted that absorptive corrections to the electromagnetic form factor in high-energy proton-proton scattering are important for the theoretical interpretation of the p ↑ p and p ↑ A analyzing power A N ( t ) measurements with the Hydrogen Jet Target polarimeter (HJET) at RHIC. Here, a concise expression for the absorptive correction was derived within the eikonal approach. The resulting analysis reveals a systematic bias, nearly independent of the beam energy, in the experimental determination of the real-to-imaginary ratio ρ when absorption effects are overlooked in the data analysis. Quantification of this bias, as ρ meas = ρ + ( 0.036 ± 0.016 ) bias , was achieved using a Regge fit applied to available proton-proton measurements of ρ meas ( s ) and σ tot meas ( s ) . Considering the potential impact of such an effect on the experimentally determined A N ( t ) , one may enhance consistency between the HJET and STAR measurements of the hadronic spin-flip amplitude. While the sign of the bias in the value of ρ aligns with the anticipated effective increase in the proton charge radius in p p scattering due to absorption, it amplifies the observed discrepancy between σ tot meas and ρ meas values at s = 13 TeV as measured in the TOTEM experiment. Evaluation (using published TOTEM data) of the measured proton-proton d σ / d t dependence on the absorptive corrections indicated that possible soft photon corrections to the hadronic amplitude slope may be essential for such data analysis. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Electrocatalytic Hydrogen Production by [Ni(7PPh2NH)2]2+: Removing the Distinction Between Endo- and Exo- Protonation Sites

A new Ni(II) complex, [Ni(7PPh2NH)2]2+ (7PPh2NH = 3,6-triphenyl-1-aza-3,6-diphosphacycloheptane) has been synthesized, and its electrochemical properties are reported. The 7PPh2NH ligand features an NH, ensuring properly positioned protonated amine groups (N–H+) for electrocatalysis, regardless of whether protonation occurs exo- or endo- to the metal center. The compound is an electrocatalyst for H2 production in the presence of organic acids (pKa range 10–13 in CH3CN) with turnover frequencies ranging from 160–770 s-1 at overpotentials between 320–470 mV, as measured at the half peak potential of the catalytic wave. In stark contrast to [Ni(PR2NR'2)2]2+ and other [Ni(7PPh2NR')]2+ complexes, catalytic turnover frequencies for H2 production by [Ni(7PPh2NH)2]2+ do not show catalytic rate enhancement upon the addition of H2O. This finding supports the assertion that [Ni(7PPh2NH)2]2+ eliminates the distinction between the endo- and exo-protonation isomers. This research was supported as part of the Center for Molecular Electrocatalysis, an Energy Frontier Research Center funded by the U.S. Department of Energy, Office of Science, Office of Basic Energy Sciences. Pacific Northwest National Laboratory is operated by Battelle for the U.S. Department of Energy.

nickel phosphine, electrocatalyst, proton movement↗

Persistent Subdiffusive Proton Transport in Perfluorosulfonic Acid Membranes

Proton transport (PT) in solutions of small amphiphiles in water has previously been shown to be subdiffusive for long times. The present study analyzes simulations of hydrated perfluorosulfonic acid (PFSA) membranes in order to determine whether PT is also subdiffusive in these important amphiphilic systems. Here, we show that PT is indeed subdiffusive for several hundred picoseconds for all hydration levels examined, and the subdiffusive behavior is highly dependent on water concentration. We also investigate the caging of the excess proton using a recently developed technique and show that the excess proton exhibits caging effects up to at least 1 ns in PFSA systems. In order to fully characterize the long-time behavior of PT in PFSAs, these results demonstrate that multiple nanosecond trajectories are needed, well beyond the current capabilities of ab initio molecular dynamics.

25 ENERGY STORAGE↗

Proton trajectories and electric fields in a laser-accelerated focused proton beam

The focusing properties of a laser generated proton beam have been investigated using hemispherical targets in both freestanding and enclosed cone-shaped geometries. The proton trajectories and focusing were strongly affected by the electric fields in the beam, bending the trajectories near the axis. In the cone targets, a sheath field effectively channels the proton beam through the open cone tip, substantially improving the beam focusing from Almost-Equal-To 90 {mu}m to Almost-Equal-To 55 {mu}m diameter for protons with energies >3 MeV. The proton generation and focusing were modeled using 2D hybrid particle-in-cell simulations, which compared well with the experimental results. Simulations predict further improvement in focusing with more uniform target illumination. These results are of significant interest to proton fast ignition and other high energy density physics applications.

43 PARTICLE ACCELERATORS↗

Qualitative comparison of bremsstrahlung X-rays and 800 MeV protons for tomography of urania fuel pellets

We present an assessment of x-rays and proton tomography as tools for studying the time dependence of the development of damage in fuel rods. We also show data taken with existing facilities at Los Alamos National Laboratory that support this assessment. Data on surrogate fuel rods have been taken using the 800 MeV proton radiography (pRad) facility at the Los Alamos Neutron Science Center (LANSCE), and with a 450 keV bremsstrahlung X-ray tomography facility. The proton radiography pRad facility at LANSCE can provide good position resolution (<70 {mu}m has been demonstrate, 20 {mu}m seems feasible with minor changes) for tomography on activated fuel rods. Bremsstrahlung x-rays may be able to provide better than 100 {mu}m resolution but further development of sources, collimation, and detectors is necessary for x-rays to deal with the background radiation for tomography of activated fuel rods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron transfer activation of a second water channel for proton transport in [FeFe]-hydrogenase

Hydrogenase enzymes are important because they can reversibly catalyze the production of molecular hydrogen. Proton transport mechanisms have been previously studied in residue pathways that lead to the active site of the enzyme via residues Cys299 and Ser319. The importance of this pathway and these residues has been previously exhibited through site-specific mutations, which were shown to interrupt the enzyme activity. It has been shown recently that a separate water channel (WC2) is coupled with electron transport to the active site of the [FeFe]-hydrogenase. The water-mediated proton transport mechanisms of the enzyme in different electronic states have been studied using the multistate empirical valence bond reactive molecular dynamics method, in order to understand any role WC2 may have in facilitating the residue pathway in bringing an additional proton to the enzyme active site. In a single electronic state A{sup 2−}, a water wire was formed through which protons can be transported with a low free energy barrier. The remaining electronic states were shown, however, to be highly unfavorable to proton transport in WC2. A double amino acid substitution is predicted to obstruct proton transport in electronic state A{sup 2-} by closing a cavity that could otherwise fill with water near the proximal Fe of the active site.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement of pulsed-power-driven magnetic fields via proton deflectometry

Measuring magnetic field and current distribution in Z-pinch plasma systems is crucial to the validation of Z-pinch theory. In this letter, the demonstration of proton deflectometry to pulsed-power-driven loads at the mega-amp scale is presented, which is capable of making more detailed field maps in high-density regions of plasmas. In this method, a laser-driven, broad-spectrum, MeV-energy proton beam is directed through a pulsed-power-driven plasma system, and the resulting deflections are measured to examine configuration of magnetic fields and to infer the currents that support them. The technique was first demonstrated on simple short-circuit loads, and the results are in excellent agreement with numerical simulations providing reliable estimates of the field and current configurations. It was then applied to a more complex—radial foil—plasma load. The measurements show unexpected proton deflections that exhibit the complexity of the plasma load and that with further analysis will reveal details about the current and magnetic field topology in this complex configuration.

Mariscal, D.↗

Impact of x-ray dose on track formation and data analysis for CR-39-based proton diagnostics

The nuclear track detector CR-39 is used extensively for charged particle diagnosis, in particular proton spectroscopy, at inertial confinement fusion facilities. These detectors can absorb x-ray doses from the experiments in the order of 1–100 Gy, the effects of which are not accounted for in the previous detector calibrations. X-ray dose absorbed in the CR-39 has previously been shown to affect the track size of alpha particles in the detector, primarily due to a measured reduction in the material bulk etch rate [Rojas-Herrera et al., Rev. Sci. Instrum. 86, 033501 (2015)]. Similar to the previous findings for alpha particles, protons with energies in the range 0.5–9.1 MeV are shown to produce tracks that are systematically smaller as a function of the absorbed x-ray dose in the CR-39. The reduction of track size due to x-ray dose is found to diminish with time between exposure and etching if the CR-39 is stored at ambient temperature, and complete recovery is observed after two weeks. Lastly, the impact of this effect on the analysis of data from existing CR-39-based proton diagnostics on OMEGA and the National Ignition Facility is evaluated and best practices are proposed for cases in which the effect of x rays is significant.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nuclear structure relevant to neutrinoless double {beta} decay: The valence protons in {sup 76}Ge and {sup 76}Se

The possibility of observing neutrinoless double {beta} decay offers the opportunity of determining the effective neutrino mass if the nuclear matrix element were known. Theoretical calculations are uncertain, and the occupation of valence orbits by nucleons active in the decay is likely to be important. The occupation of valence proton orbits in the ground states of {sup 76}Ge, a candidate for such decay, and {sup 76}Se, the corresponding daughter nucleus, is determined by precisely measuring cross sections for proton-removing transfer reactions. As in previous work on neutron occupation, we find that the Fermi surface for protons is much more diffuse than previously thought, and the occupancies of at least three orbits change significantly between the two 0{sup +} ground states.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Commissioning of the discrete spot scanning proton beam delivery system at University of Texas M.D. Anderson Cancer Center, Proton Therapy Center, Houston

Purpose: To describe a summary of the clinical commissioning of the discrete spot scanning proton beam at the Proton Therapy Center, Houston (PTC-H). Methods: Discrete spot scanning system is composed of a delivery system (Hitachi ProBeat), an electronic medical record (Mosaiq V 1.5), and a treatment planning system (TPS) (Eclipse V 8.1). Discrete proton pencil beams (spots) are used to deposit dose spot by spot and layer by layer for the proton distal ranges spanning from 4.0 to 30.6 g/cm{sup 2} and over a maximum scan area at the isocenter of 30x30 cm{sup 2}. An arbitrarily chosen reference calibration condition has been selected to define the monitor units (MUs). Using radiochromic film and ion chambers, the authors have measured spot positions, the spot sizes in air, depth dose curves, and profiles for proton beams with various energies in water, and studied the linearity of the dose monitors. In addition to dosimetric measurements and TPS modeling, significant efforts were spent in testing information flow and recovery of the delivery system from treatment interruptions. Results: The main dose monitors have been adjusted such that a specific amount of charge is collected in the monitor chamber corresponding to a single MU, following the IAEA TRS 398 protocol under a specific reference condition. The dose monitor calibration method is based on the absolute dose per MU, which is equivalent to the absolute dose per particle, the approach used by other scanning beam institutions. The full width at half maximum for the spot size in air varies from approximately 1.2 cm for 221.8 MeV to 3.4 cm for 72.5 MeV. The measured versus requested 90% depth dose in water agrees to within 1 mm over ranges of 4.0-30.6 cm. The beam delivery interlocks perform as expected, guarantying the safe and accurate delivery of the planned dose. Conclusions: The dosimetric parameters of the discrete spot scanning proton beam have been measured as part of the clinical commissioning program, and the machine is found to function in a safe manner, making it suitable for patient treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measurements of neutron dose equivalent for a proton therapy center using uniform scanning proton beams

Purpose: Neutron exposure is of concern in proton therapy, and varies with beam delivery technique, nozzle design, and treatment conditions. Uniform scanning is an emerging treatment technique in proton therapy, but neutron exposure for this technique has not been fully studied. The purpose of this study is to investigate the neutron dose equivalent per therapeutic dose, H/D, under various treatment conditions for uniform scanning beams employed at our proton therapy center. Methods: Using a wide energy neutron dose equivalent detector (SWENDI-II, ThermoScientific, MA), the authors measured H/D at 50 cm lateral to the isocenter as a function of proton range, modulation width, beam scanning area, collimated field size, and snout position. They also studied the influence of other factors on neutron dose equivalent, such as aperture material, the presence of a compensator, and measurement locations. They measured H/D for various treatment sites using patient-specific treatment parameters. Finally, they compared H/D values for various beam delivery techniques at various facilities under similar conditions. Results: H/D increased rapidly with proton range and modulation width, varying from about 0.2 mSv/Gy for a 5 cm range and 2 cm modulation width beam to 2.7 mSv/Gy for a 30 cm range and 30 cm modulation width beam when 18 Multiplication-Sign 18 cm{sup 2} uniform scanning beams were used. H/D increased linearly with the beam scanning area, and decreased slowly with aperture size and snout retraction. The presence of a compensator reduced the H/D slightly compared with that without a compensator present. Aperture material and compensator material also have an influence on neutron dose equivalent, but the influence is relatively small. H/D varied from about 0.5 mSv/Gy for a brain tumor treatment to about 3.5 mSv/Gy for a pelvic case. Conclusions: This study presents H/D as a function of various treatment parameters for uniform scanning proton beams. For similar treatment conditions, the H/D value per uncollimated beam size for uniform scanning beams was slightly lower than that from a passive scattering beam and higher than that from a pencil beam scanning beam, within a factor of 2. Minimizing beam scanning area could effectively reduce neutron dose equivalent for uniform scanning beams, down to the level close to pencil beam scanning.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-C-204-02: Improved Patient-Specific Optimization of the Stopping Power Calibration for Proton Therapy Planning Using a Single Proton Radiography

Purpose: We present an improved method to calculate patient-specific calibration curves to convert X-ray computed tomography (CT) Hounsfield Unit (HU) to relative stopping powers (RSP) for proton therapy treatment planning. Methods: By optimizing the HU-RSP calibration curve, the difference between a proton radiographic image and a digitally reconstructed X-ray radiography (DRR) is minimized. The feasibility of this approach has previously been demonstrated. This scenario assumes that all discrepancies between proton radiography and DRR originate from uncertainties in the HU-RSP curve. In reality, external factors cause imperfections in the proton radiography, such as misalignment compared to the DRR and unfaithful representation of geometric structures (“blurring”). We analyze these effects based on synthetic datasets of anthropomorphic phantoms and suggest an extended optimization scheme which explicitly accounts for these effects. Performance of the method is been tested for various simulated irradiation parameters. The ultimate purpose of the optimization is to minimize uncertainties in the HU-RSP calibration curve. We therefore suggest and perform a thorough statistical treatment to quantify the accuracy of the optimized HU-RSP curve. Results: We demonstrate that without extending the optimization scheme, spatial blurring (equivalent to FWHM=3mm convolution) in the proton radiographies can cause up to 10% deviation between the optimized and the ground truth HU-RSP calibration curve. Instead, results obtained with our extended method reach 1% or better correspondence. We have further calculated gamma index maps for different acceptance levels. With DTA=0.5mm and RD=0.5%, a passing ratio of 100% is obtained with the extended method, while an optimization neglecting effects of spatial blurring only reach ∼90%. Conclusion: Our contribution underlines the potential of a single proton radiography to generate a patient-specific calibration curve and to improve dose delivery by optimizing the HU-RSP calibration curve as long as all sources of systematic incongruence are properly modeled.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP2-13: Patient-Specific Reduction of Range Uncertainties in Proton Therapy by Proton Radiography with a Multi-Layer Ionization Chamber

Purpose: The conversion from Hounsfield units (HU) to stopping powers is a major source of range uncertainty in proton therapy (PT). Our contribution shows how proton radiographs (PR) acquired with a multi-layer ionization chamber in a PT center can be used for accurate patient positioning and subsequently for patient-specific optimization of the conversion from HU to stopping powers. Methods: A multi-layer ionization chamber was used to measure the integral depth-dose (IDD) of 220 MeV pencil beam spots passing through several anthropomorphic phantoms. The whole area of interest was imaged by repositioning the couch and by acquiring a 45×45 mm{sup 2} frame for each position. A rigid registration algorithm was implemented to correct the positioning error between the proton radiographs and the planning CT. After registration, the stopping power map obtained from the planning CT with the calibration curve of the treatment planning system was used together with the water equivalent thickness gained from two proton radiographs to generate a phantom-specific stopping power map. Results: Our results show that it is possible to make a registration with submillimeter accuracy from proton radiography obtained by sending beamlets separated by more than 1 mm. This was made possible by the complex shape of the IDD due to the presence of lateral heterogeneities along the path of the beam. Submillimeter positioning was still possible with a 5 mm spot spacing. Phantom specific stopping power maps obtained by minimizing the range error were cross-verified by the acquisition of an additional proton radiography where the phantom was positioned in a random but known manner. Conclusion: Our results indicate that a CT-PR registration algorithm together with range-error based optimization can be used to produce a patient-specific stopping power map. Sylvain Deffet reports financial funding of its PhD thesis by Ion Beam Applications (IBA) during the confines of the study and outside the submitted work. Francois Vander Stappen reports being employed by Ion Beam Applications (IBA) during the confines of the study and outside the submitted work.

60 APPLIED LIFE SCIENCES↗

Experimental Studies Of An Exotic Decay Mode At The Proton Drip-Line: The Two-Proton Radioactivity

Two-proton radioactivity is an exotic decay mode for very proton-rich nuclei. It was observed experimentally for the first time in 2002 for the nucleus {sup 45}Fe but the two protons could not be directly detected. So a new detector has been developed, a Time Projection Chamber, to individually observe the two protons emitted. It was used successfully during two experiments for the study of {sup 45}Fe and {sup 54}Zn. Energy correlations have been studied and the relative angle between the two protons is calculated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Note: A monoenergetic proton backlighter for the National Ignition Facility

A monoenergetic, isotropic proton source suitable for proton radiography applications has been demonstrated at the National Ignition Facility (NIF). A deuterium and helium-3 gas-filled glass capsule was imploded with 39 kJ of laser energy from 24 of NIF’s 192 beams. Spectral, spatial, and temporal measurements of the 15-MeV proton product of the {sup 3}He(d,p){sup 4}He nuclear reaction reveal a bright (10{sup 10} protons/sphere), monoenergetic (ΔE/E = 4%) spectrum with a compact size (80 μm) and isotropic emission (∼13% proton fluence variation and <0.4% mean energy variation). Simultaneous measurements of products produced by the D(d,p)T and D(d,n){sup 3}He reactions also show 2 × 10{sup 10} isotropically distributed 3-MeV protons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A New Class of Proton Conductors with Dramatically Enhanced Stability and High Conductivity for Reversible Solid Oxide Cells

Reversible solid oxide cells based on proton conductors (P-ReSOCs) have potential to be the most efficient and low-cost option for large-scale energy storage and power generation, holding promise as an enabler for the implementation of intermittent renewable energy technologies and the widespread utilization of hydrogen. Here, the rational design of a new class of hexavalent Mo/W-doped proton-conducting electrolytes with excellent durability while maintaining high conductivity is reported. Specifically, BaMo(W) 0.03 Ce 0.71 Yb 0.26 O 3-δ exhibits dramatically enhanced chemical stability against high concentrations of steam and carbon dioxide than the state-of-the-art electrolyte materials while retaining similar ionic conductivity. In addition, P-ReSOCs based on BaW 0.03 Ce 0.71 Yb 0.26 O 3-δ demonstrate high peak power densities of 1.54, 1.03, 0.72, and 0.48 W cm –2 at 650, 600, 550, and 500 °C, respectively, in the fuel cell mode. During steam electrolysis, a high current density of 2.28 A cm –2 is achieved at a cell voltage of 1.3 V at 600 °C, and the electrolysis cell can operate stably with no noticeable degradation when exposed to high humidity of 30% H 2 O at –0.5 A cm –2 and 600 °C for over 300 h. Altogether, this work demonstrates the promise of donor doping for obtaining proton conductors with both high conductivity and chemical stability for P-ReSOCs.

25 ENERGY STORAGE↗

Effects of proton irradiation on nanocluster precipitation in ferritic steel containing fcc alloying additions

Newly-developed precipitate-strengthened ferritic steels with and without pre-existing nanoscale precipitates were irradiated with 4 MeV protons to a dose of ~5 mdpa at 50 C and subsequently examined by nanoindentation and atom probe tomography (APT). Irradiation-enhanced precipitation and coarsening of pre-existing nanoscale precipitates were observed. Copper partitions to the precipitate core along with a segregation of Ni, Al and Mn to the precipitate/matrix interface after both thermal aging and proton irradiation. Proton irradiation induces the precipitation reaction and coarsening of pre-existing nanoscale precipitates, and these results are similar to a thermal aging process. The precipitation and coarsening of nanoscale precipitates are responsible for the changes in hardness. The observation of the radiation-induced softening is essentially due to the coarsening of the pre-existing Cu-rich nanoscale precipitates. The implication of the precipitation on the embrittlement of reactor-pressure-vessel steels after irradiation is discussed.

Zhang, Zhongwu↗