Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Predictive Maintenance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Predicting demand for hydrogen station fueling

Full function hydrogen stations are a reality; fuel cell electric vehicle drivers can pull up to commercial fueling stations and receive 3–5 kg in less than 5 min, for an approximately 300-mile range. The demand for hydrogen is increasing, driven by an increase in the fueling of public and private fuel cell vehicles. This study describes the development and value of a model that simulates stochastic future demand at a hydrogen filling station. The predictive hydrogen demand model described in this article is trained from mathematical models constructed from actual hydrogen fill count, amount, and frequency data. Future fill probabilities inform the hour-by-hour demand profile and the station state of either “available, ready to fill” or “available, filling”. For example, a prediction for a station generally dispensing 5,000 kg a week on a Friday afternoon at 4 p.m. is 16 fills, totaling 48.7 kg, with a 0.52 proportion of time spent in “available, filling” state yielding 31 min of filling time. This is a first-of-its kind, published study on predicting future hydrogen demand by the time of day (e.g., hour-by-hour intervals) and day of week. This study can be used for hydrogen station requirements and operation and maintenance strategies and to assess the impact of demand variations and scenarios. Finally, this article presents the current status of hydrogen demand, the model development methods, a set of sample results. Discussion and conclusions concentrate on the value and use of the proposed model.

08 HYDROGEN↗

AI-Enabled Robots for Automated Nondestructive Evaluation and Repair of Power Plant Boilers. Final Report

Boiler failure could cause loss of life and safety issues, cost hundreds of thousands of dollars in equipment repairs, property damage and production losses, and drive up the cost of electric power. Boiler maintenance is challenging and risky for inspectors working on scaffolding in confined hazardous spaces inside of a boiler and sometimes the space is hard to access. The operation is also time-consuming due to the large area of vertical structures for inspection and the tremendous effort needed for scaffolding. Recently, the use of robotics (e.g., drones and crawlers) in power plants for maintenance is growing rapidly. However, the existing robotics solutions show two notable technological gaps: no live repair capability, and no Artificial Intelligence (AI) for smart autonomy. The objective of this project is to develop an integrated autonomous robotic platform that is equipped with compact non-destructive evaluation (NDE) sensors to perform live inspection, operates onboard repair devices to perform live repair, and uses AI for intelligent data fusion and predictive analysis for automated and smart spatiotemporal inspection, analysis and repair of the furnace walls in coal-fired boilers. The approach to achieve the objective includes developing NDE sensors with signal processing techniques, designing and evaluating repair devices for robots based on fusion and solid-state technologies, and an autonomous robotic platform that can attach to and navigate on boiler furnace walls using magnetic drive tracks. The robot is also powered by AI to automate data gathering (e.g., 3D mapping and damage localization) and predictive analysis. This project has advanced the state-of-the-art by providing technological breakthroughs including compact NDE and repair tools for robots, AI capabilities for smart autonomy, and a robotic platform for automated boiler maintenance. This project has great potential to result in significant benefits including limiting or eliminating the need to send operators to assess difficult-to-access or hazardous areas, enabling automated live inspection and repair, avoiding time consuming scaffolding (especially for partial maintenance during unplanned outage), collecting comprehensive and well-organized data smartly, and avoiding or limiting the need for onsite or remote piloting technicians. The impacts can be tremendous in terms of the time and cost savings, reducing the risk for human operators, and increasing boiler reliability, usability, and efficiency. In addition, by developing the new technologies on the autonomous inspection and repair robot, by involving multiple undergraduate and graduate students working together with the faculty members on this project, and by generating knowledge and building up collaborations with industrial partners, this effort will significantly update the education capabilities, support long-term fundamental research, and maintain the leadership of Colorado School of Mines and Michigan State University in energy fields.

20 FOSSIL-FUELED POWER PLANTS↗

A Universal Refrigerant Charge Fault Detection and Diagnostics Method Based on Pump Down Operation

The performance of the heat pump system varies greatly depending on the refrigerant charge amount. Improving the refrigerant charge fault detection and diagnostics (FDD) method of vapor compression systems have the potential for increasing energy efficiency and reducing service cost. Previous studies to predict refrigerant charge amount are mostly empirical methods which require significant amount of experimental data for high accuracy. The primary goal of this research is to develop a universal charge fault detection method which requires only a few experimental data with high prediction accuracy.Currently, pump down operations are typical practices by HVAC technicians when they need to open the refrigerant circuit to make a repairment. In addition, compressors have a built-in low-pressure cut-off protection function, and the compressor performance maps are commonly available from manufacturers. The proposed method innovatively utilizes the typical pump down operation, the compressor low-pressure cut-off protection, and the compressor performance map. It does not require any geometry information of heat exchangers, refrigerant lines, or charge buffers.The new charge prediction method is firstly formulated through theoretical analysis, then verified and calibrated by a quasi-steady-state simulation of the pump down process for a residential heat pump system. The quasi steady-state simulation uses an HVAC system simulation framework driven by DOE/ORNL Heat Pump Design Model (HPDM). Preliminary experiment validations with heat pump refrigerant leakage tests demonstrate the deviation of the proposed charge prediction method compared with measurement is within 8%. This technology makes refrigerant charge amount available at the technician’s fingertips and leads to shorter maintenance time and fewer site visits.

Li, Zhenning↗

Machine Learning–Based Condition Monitoring of a Circulating Water System of a Canadian Nuclear Plant

With the need to maintain long-term reliable energy using nuclear power plants, there is an underlying demand to ensure that the maintenance of plant components and systems is also done in an efficient and cost-effective manner. One way to achieve this is by moving from time-based maintenance to condition-based maintenance. The research presented in this paper focuses on applying statistical and machine-learning-based methods to capture anomalies within data for fault detection to further develop into condition monitoring. This paper focuses on system data for a circulating water system (CWS) of a pressurized heavy-water reactor for detecting anomalies. The different methodologies used for detecting and capturing anomalies in the CWS data are matrix profile, density-based spatial clustering of applications with noise (DBSCAN), and support vector machines (SVMs). Matrix profile and DBSCAN are used to distinguish between normal data and anomalous data. This paper presents a hybrid method using DBSCAN and SVM when a portion of the data is used for DBSCAN to generate clusters. This portion of data is then used to train the SVM along with the clusters generated by DBSCAN as output. SVM is then tested on unseen data as a predictive tool, which can work in real time to categorize data points as either normal or anomalous. This paper presents results that show the high accuracies of DBSCAN and SVM in capturing anomalies within the data for a CWS for fault detection. Thus, the maintenance plan would be focused on component condition rather than a time-based schedule by switching to an automated system to identify and predict faults within a CWS.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SSL and LED life prediction and assessment of CCT shift

Solid-state lighting (SSL) products can have a predicted life of 70% lumen output (L70) from 26,000 to 40,000 hours using the LM-80-08 testing standards. Chromaticity shift, correlated color temperature (CCT) and lumen maintenance (LM) will dramatically reduce the nominal life of SSL luminaires. In this work, an off-the-shelf luminaire from Philips (AmbientLED) has been aged in a standard wet hot temperature operating life (WHTOL) of 85% relative humidity and 85°C (85/85) in order to assess reliability of prolonged exposer in a harsh environment. Failure criterion has been derived using the Arrhenius equation from the LM-80-08 standard, as well as the 60W LED Lamp test report from an isothermal environment of 45°C. This is a similar luminaire to the test vehicle used in this research. Data characterization between the two data sets has been carried out to determine the luminaires reliability and life under the 85/85 test conditions. This characterization allows for the determination of poor quality luminaire products in the market place. The distribution properties of the shifting mean values of CCT and LM were incorporated into the Bayesian Linear Regression (BLR) to determine the degradation pattern, in order to predict the remaining useful life (RUL) of the system due to aging before the end-of-life (EoL).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Saccharomyces cerevisiae Hrq1 requires a long 3 Prime -tailed DNA substrate for helicase activity

Highlights: Black-Right-Pointing-Pointer Hrq1 has intrinsic 3 Prime -5 Prime helicase and DNA strand annealing activities. Black-Right-Pointing-Pointer Hrq1 requires a long 3 Prime -tail for efficient DNA unwinding. Black-Right-Pointing-Pointer Helicase activity of Hrq1 is stimulated by a fork structure. Black-Right-Pointing-Pointer Hrq1 is a moderately processive helicase. -- Abstract: RecQ helicases are well conserved proteins from bacteria to human and function in various DNA metabolism for maintenance of genome stability. Five RecQ helicases are found in humans, whereas only one RecQ helicase has been described in lower eukaryotes. However, recent studies predicted the presence of a second RecQ helicase, Hrq1, in fungal genomes and verified it as a functional gene in fission yeast. Here we show that 3 Prime -5 Prime helicase activity is intrinsically associated with Hrq1 of Saccharomyces cerevisiae. We also determined several biochemical properties of Hrq1 helicase distinguishable from those of other RecQ helicase members. Hrq1 is able to unwind relatively long duplex DNA up to 120-bp and is significantly stimulated by a preexisting fork structure. Further, the most striking feature of Hrq1 is its absolute requirement for a long 3 Prime -tail ( Greater-Than-Or-Slanted-Equal-To 70-nt) for efficient unwinding of duplex DNA. We also found that Hrq1 has potent DNA strand annealing activity. Our results indicate that Hrq1 has vigorous helicase activity that deserves further characterization to expand our understanding of RecQ helicases.

60 APPLIED LIFE SCIENCES↗

Adaptive reduction of constitutive model-form error using a posteriori error estimation techniques

In engineering practice, models are typically kept as simple as possible for ease of setup and use, computational efficiency, maintenance, and overall reduced complexity to achieve robustness. In solid mechanics, a simple and efficient constitutive model may be favored over one that is more predictive, but is difficult to parameterize, is computationally expensive, or is simply not available within a simulation tool. In order to quantify the modeling error due to the choice of a relatively simple and less predictive constitutive model, we adopt the use of a posteriori model-form error-estimation techniques. Based on local error indicators in the energy norm, an algorithm is developed for reducing the modeling error by spatially adapting the material parameters in the simpler constitutive model. The resulting material parameters are not material properties per se , but depend on the given boundary-value problem. As a first step to the more general nonlinear case, we focus here on linear elasticity in which the “complex” constitutive model is general anisotropic elasticity and the chosen simpler model is isotropic elasticity. As a result, the algorithm for adaptive error reduction is demonstrated using two examples: (1) A transversely-isotropic plate with hole subjected to tension, and (2) a transversely-isotropic tube with two side holes subjected to torsion.

42 ENGINEERING↗

Real-time monitoring and prediction of water quality parameters and algae concentrations using microbial potentiometric sensor signals and machine learning tools

We report the overarching hypothesis of this study was that temporal microbial potentiometric sensor (MPS) signal patterns could be used to predict changes in commonly monitored water quality parameters by using artificial intelligence/machine learning tools. To test this hypothesis, the study first examines a proof of concept by correlating between MPS's signals and high algae concentrations in an algal cultivation pond. Then, the study expanded upon these findings and examined if multiple water quality parameters could be predicted in real surface waters, like irrigation canals. Signals generated between the MPS sensors and other water quality sensors maintained by an Arizona utility company, including algae and chlorophyll, were collected in real time at time intervals of 30 min over a period of 9 months. Data from the MPS system and data collected by the utility company were used to train the ML/AI algorithms and compare the predicted with actual water quality parameters and algae concentrations. Based on the composite signal obtained from the MPS, the ML/AI was used to predict the canal surface water's turbidity, conductivity, chlorophyll, and blue-green algae (BGA), dissolved oxygen (DO), and pH, and predicted values were compared to the measured values. Initial testing in the algal cultivation pond revealed a strong linear correlation (R 2 = 0.87) between mixed liquor suspended solids (MLSS) and the MPSs' composite signals. The Normalized Root Mean Square Error (NRMSE) between the predicted values and measured values were <6.5%, except for the DO, which was 10.45%. The results demonstrate the usefulness of MPSs to predict key surface water quality parameters through a single composite signal, when the ML/AI tools are used conjunctively to disaggregate these signal components. The maintenance-free MPS offers a novel and cost-effective approach to monitor numerous water quality parameters at once with relatively high accuracy.

54 ENVIRONMENTAL SCIENCES↗

Opportunities for Automated Demand Response in Wastewater Treatment Facilities in California - Southeast Water Pollution Control Plant Case Study

This report details a study into the demand response potential of a large wastewater treatment facility in San Francisco. Previous research had identified wastewater treatment facilities as good candidates for demand response and automated demand response, and this study was conducted to investigate facility attributes that are conducive to demand response or which hinder its implementation. One years' worth of operational data were collected from the facility's control system, submetered process equipment, utility electricity demand records, and governmental weather stations. These data were analyzed to determine factors which affected facility power demand and demand response capabilities The average baseline demand at the Southeast facility was approximately 4 MW. During the rainy season (October-March) the facility treated 40% more wastewater than the dry season, but demand only increased by 4%. Submetering of the facility's lift pumps and centrifuges predicted load shifts capabilities of 154 kW and 86 kW, respectively, with large lift pump shifts in the rainy season. Analysis of demand data during maintenance events confirmed the magnitude of these possible load shifts, and indicated other areas of the facility with demand response potential. Load sheds were seen to be possible by shutting down a portion of the facility's aeration trains (average shed of 132 kW). Load shifts were seen to be possible by shifting operation of centrifuges, the gravity belt thickener, lift pumps, and external pump stations These load shifts were made possible by the storage capabilities of the facility and of the city's sewer system. Large load reductions (an average of 2,065 kW) were seen from operating the cogeneration unit, but normal practice is continuous operation, precluding its use for demand response. The study also identified potential demand response opportunities that warrant further study: modulating variable-demand aeration loads, shifting operation of sludge-processing equipment besides centrifuges, and utilizing schedulable self-generation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

INVESTIGATION OF HUMAN RELIABILITY ANALYSIS METHODS FOR ANALYZING PRE-INITIATORS

As a type of human actions defined in human reliability analysis (HRA), pre-initiator refers to the human actions that may lead to the unavailability of systems, typically committed during maintenance, test, or calibration. This paper investigates representative HRA methods used for analyzing pre-initiators. The HRA methods are Technique for Human Error Rate Prediction (THERP), Korean Standard HRA (K-HRA) and Standard Plant Risk HRA (SPAR-H). In this paper, characteristics of each HRA method are compared for qualitative and quantification aspects. Two pre-initiators, i.e., a calibration task and a valve restoration task, are analyzed using the HRA methods to compare human error probabilities. Then, insights from the analysis and additional research requirements are discussed in this paper.

99 GENERAL AND MISCELLANEOUS↗

INVESTIGATION OF HUMAN RELIABILITY ANALYSIS METHODS FOR ANALYZING PRE-INITIATORS

As a type of human actions defined in human reliability analysis (HRA), pre-initiator refers to the human actions that may lead to the unavailability of systems, typically committed during maintenance, test, or calibration. This paper investigates representative HRA methods used for analyzing pre-initiators. The HRA methods are Technique for Human Error Rate Prediction (THERP), Korean Standard HRA (K-HRA) and Standard Plant Risk HRA (SPAR-H). In this paper, characteristics of each HRA method are compared for qualitative and quantification aspects. Two pre-initiators, i.e., a calibration task and a valve restoration task, are analyzed using the HRA methods to compare human error probabilities. Then, insights from the analysis and additional research requirements are discussed in this paper.

99 GENERAL AND MISCELLANEOUS↗

Comparing the economic performance of ice storage and batteries for buildings with on-site PV through model predictive control and optimal sizing

Integrating renewable energy and energy storage systems provides a way of operating the electrical grid system more energy efficiently and stably. Thermal storage and batteries are the most common devices for integration. However, it is not clear which integrated storage system performs better in terms of overall economics. Ice storage has low initial and maintenance costs, but there is an efficiency penalty for charging of storage and it can only shift electrical loads associated with building cooling requirements. A battery's round-trip efficiency, on the contrary, is quite consistent and batteries can be used to shift both HVAC and non-HVAC loads. However, batteries have greater initial costs and a shorter life. Finally, this research presents a tool, using model predictive control and optimal sizing, and provides a case study for comparing life-cycle economics of battery and ice storage systems for commercial buildings that have chillers for cooling and an on-site photovoltaic system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ActiveBAS: A Low-cost, Scalable Control Solution for Grid-Interactive Small and Medium Sized Commercial Buildings

This project aims to develop and enhance a low-cost, highly scalable control solution for Small and Medium-Sized Commercial Buildings (SMCB), assess the business potential at multiple sites, and perform commercialization efforts. The technology can be applied to any buildings served by multiple units, with the benefits being greatest for open-spaced buildings, such as banks, retail stores, restaurants, and factories. This project aims to develop an affordable control solution for: 1) SMCB grid responsiveness, 2) reduction of GHG by changing unit operations, 3) greater reduction in utility costs, and 4) rapid adoption in the marketplace. The proposed technology will be built on a previously developed and demonstrated MPC solution. The minimal sensor requirement and less need of control expertise are the unique feature of the algorithm that leads to low capital and maintenance costs, and short installation and implementation time. These attributes contribute to low capital and maintenance costs, as well as a short installation and implementation time. However, these advantages come with a trade-off: increased difficulties and unreliability when applying traditional modeling and MPC control approaches due to limited information. This final report describes the modeling approaches developed and tested to overcome these challenges. It begins by outlining the modeling challenge posed by minimal sensor requirements, then delves into the proposed modeling approaches, which primarily involve system identification. Finally, preliminary test results for a simulation case study are presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Control and Service Life Extension of Accelerator's Anode Voltage Regulator

Accelerator's beam quality is highly affected by the anode voltage's stability. The accelerator examined in this study is an ion implantation accelerator which anode voltage is regulated by an electromechanical system shown in Fig 1. The system works by stepping down the input grid voltage to generate a high anode voltage of up to 2.5 kV through a motor generator. It was desired that the system be able to correct for disturbances and instabilities in the input voltage swiftly while minimizing overshoots and steady state errors. Moreover, it should maintain such capability satisfactorily despite of degradations. It was predicted that this adaptive capability would be limited to a certain extent where if degradations become too severe, system's performance would deteriorate considerably such that maintenance actions or component replacements are required. The mechanism to control anode voltage, estimate and extend the system's Remaining Useful Life (RUL) in an integrated manner is explored in this paper. (authors)

43 PARTICLE ACCELERATORS↗

Measurement of free chlorine levels in water using potentiometric responses of biofilms and applications for monitoring and managing the quality of potable water

We report residual free chlorine is not monitored continuously at scale in drinking water distribution systems because existing real-time sensor technologies require frequent maintenance, cleaning, and calibration, which makes these products too costly to be used throughout a distribution system. As a result, current measurement approaches require manual sampling, which is not feasible for the consistent monitoring of free chlorine because chlorine concentrations vary significantly throughout pipeline distribution and over time and space. This research presents an alternative and cost-effective method of predicting free chlorine levels in drinking water using graphite electrodes coated with naturally grown microbial biofilms. This Microbial Potentiometric Sensor (MPS) array was installed in a Continuously Mixed Batch Reactor (CMBR), and drinking water containing variable free chlorine concentrations. The chlorine concentrations were introduced in a controlled manner, and the MPS signals were monitored over time. MPS signals were measured from the change in Open Circuit Potential (OCP) across the MPS array in real-time. An empirically derived relationship between the normalized change in OCP and free chlorine was established by fitting individual and average MPS data to a decaying exponential growth function in order to predict free chlorine levels. The results show that free chlorine can be predicted with reasonable accuracy, with model validation showing an average absolute error of ±0.09 ppm below 1.1 ppm and ±0.30 ppm between 1.1 and 2.7 ppm. However, the accuracy of predictions was reduced at higher free chlorine levels. The researchers conclude that MPS systems may benefit drinking water distribution systems by measuring free chlorine. These advantages of the MPS are especially pronounced in the developing world because this system is inexpensive and does not require routine maintenance or cleaning. The system relies on a naturally forming and regenerating biofilm and an inexpensive potentiometric meter to produce stable measurements.

54 ENVIRONMENTAL SCIENCES↗

Metering Best Practices Applied in the National Renewable Energy Laboratory's Research Support Facility: A Primer to the 2011 Measured and Modeled Energy Consumption Datasets

Modern buildings are complex energy systems that must be controlled for energy efficiency. The Research Support Facility (RSF) at the National Renewable Energy Laboratory (NREL) has hundreds of controllers -- computers that communicate with the building's various control systems -- to control the building based on tens of thousands of variables and sensor points. These control strategies were designed for the RSF's systems to efficiently support research activities. Many events that affect energy use cannot be reliably predicted, but certain decisions (such as control strategies) must be made ahead of time. NREL researchers modeled the RSF systems to predict how they might perform. They then monitor these systems to understand how they are actually performing and reacting to the dynamic conditions of weather, occupancy, and maintenance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Preparation of Simulated LBL Defects for Round Robin Experiment

A critical characteristic of the TRISO fuel design is its ability to retain fission products. During reactor operation, the TRISO layers act as barriers to release of fission products not stabilized in the kernel. Each component of the TRISO particle and compact construction plays a unique role in retaining select fission products, and layer performance is often interrelated. The IPyC, SiC, and OPyC layers are barriers to the release of fission product gases such as Kr and Xe. The SiC layer provides the primary barrier to release of metallic fission products not retained in the kernel, as transport across the SiC layer is rate limiting due to the greater permeability of the IPyC and OPyC layers to many metallic fission products. These attributes allow intact TRISO coatings to successfully retain most fission products released from the kernel, with the majority of released fission products during operation being due to defective, damaged, or failed coatings. This dominant release of fission products from compromised particles contributes to the overall source term in reactor; causing safety and maintenance concerns and limiting the lifetime of the fuel. Under these considerations, an understanding of the nature and frequency of compromised particles is an important part of predicting the expected fission product release and ensuring safe and efficient operation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗